0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
WS10-1250-10V

WS10-1250-10V

  • 厂商:

    ASM-SENSOR

  • 封装:

  • 描述:

    WS10-1250-10V - analog or SSI output - ASM GmbH

  • 数据手册
  • 价格&库存
WS10-1250-10V 数据手册
Model WS10 with analog or SSI output Compact sensor for industrial applications · Protection class IP65 · Measurement ranges: 0 ... 100 mm to 0 ... 1250 mm · Analog output 0 … 10 V, 4 … 20 mA, potentiometer or A/D converted synchronous serial output (SSI) Outputs Specifications Resolution Material Sensing Device Connector Linearity Protection Class Weight Environmental EMC Temperature Potentiometer: 1 kW Voltage: 0...10 V Current: 4...20 mA, 2 or 3 wire Voltage and current output, adjustable A/D converted synchronous serial 16 bit max. (SSI) Essentially infinite / ADSI16: max. 16 bit full scale Aluminium and stainless steel. Cable: stainless steel Precision potentiometer Male socket 8 pin (M12 or DIN 45326) Up to ±0.05 % full scale IP65 (only when the electrical plug is correctly assembled and connected) 800 g approx. Refer to output specification Refer to output specification Order Code WS10 Analog or SSI WS10 Model Name Measurement Range (in mm) 100 / 125 / 375 / 500 / 750 / 1000 / 1250 Outputs (see pages 57 ff.) R1K = Potentiometer 1 kW (other values on request) 10V = With 0 ... 10 V signal conditioner 420A = With 4 ... 20 mA signal conditioner (2 wire) 420T = With 4 ... 20 mA signal conditioner (3 wire) PMU = With 0...10 V/4...20 mA signal conditioner, adjustable ADSI16 = With A/D converted synchronous serial output 16 bit (option: 12, 14 bit) Linearity L10 = ±0.10 % option: L05 = ±0,05 % L25 = ±0.25 % Cable fixing M4 = M4 cable fixing SB0 = Cable clip Connection M12 = 8 pin socket M12 D8 = 8 pin socket DIN 45326 Order Code Mating Connector (see accessories p. 82) D8: CONN-DIN-8F-W M12: CONN-M12-8F-G Order Example: WS10 - 1250 - 10V - L10 - M4 - M12 8 CAT-WS-E-05 www.asm-sensor.com ASM Model WS10 with analog or SSI output Range mm 100 125 375 500 750 1000 1250 Maximum pull-out force [N] 4.7 4.6 7.4 5.5 7.6 5.3 4.6 Minimum pull-in force [N] 3.0 2.4 3.9 2.8 3.8 2.9 2.4 Cable Forces typical at 20 °C Outline drawing Option SB0 Dimensions informative only. For guaranteed dimensions consult factory Range A 12.5 8.0 8.0 B, C B=31, C=38.5 D (ADSI16) 93.5 (120.5) Dimensions (mm) 375; 750 100; 125; 500 1000; 1250 ASM www.asm-sensor.com CAT-WS-E-05 9 Model WS10 with incremental encoder output Compact sensor for industrial applications · Protection class IP65 · Measurement range: 0 ... 1250 mm · With incremental encoder output Outputs Specifications Resolution Material Sensing Device Connector Linearity Protection Class Weight Environmental EMC Temperature Incremental encoder output with differential push-pull circuit for reliable data transmission. The output is compatible with TTL or HTL. 10 pulses per mm (1/40 mm with external edge counting mode) Aluminium and stainless steel. Cable: stainless steel Incremental encoder Male socket 8 pin (M12 or DIN 45326) ±0.05 % full scale IP65 (only when the electrical plug is correctly assembled and connected) 800 g approx. Refer to output specification Refer to output specification Order Code WS10 Incremental WS10 Model Name Measurement Range (in mm) 1250 (all smaller measurement ranges included) Pulses per mm 10 = 10 pulses per mm 25 = 25 pulses per mm (output PP530 only) Other numbers of pulses on request Output (see page 60) IE24LI = Incremental output TTL compatible inverted IE24HI = Incremental output HTL compatible inverted PP530 = Incremental output TTL and HTL compatible Cable fixing M4 = M4 cable fixing SB0 = Cable clip Connection M12 = 8 pin socket M12 D8 = 8 pin socket DIN 45326 Order Code Mating Connector (see accessories p. 82) D8: CONN-DIN-8F-W M12: CONN-M12-8F-G Order Example: WS10 - 1250 - 10 - IE24HI - M4 - M12 10 CAT-WS-E-05 www.asm-sensor.com ASM Model WS10 with incremental encoder output Resolution Pulses per mm 10 Maximum Pull-out Force [N] 5.8 Minimum Pull-in Force [N] 3.0 Cable Forces typical at 20 °C Outline drawing Option SB0 Dimensions informative only. For guaranteed dimensions consult factory ASM www.asm-sensor.com CAT-WS-E-05 11 Output Specifications R1K and 10V for WS position sensors Excitation Voltage Voltage divider R1K Potentiometer 32 VDC max. at 1 kW (input power 1 W max.) 1 kW ±10% ±25 x 10-6/ °C full scale Depends on measurement range, individual sensitivity of sensor specified on label Approx. 3% ... 97% of full range -20 ... +85 °C Potentiometer Impedance Thermal coefficient Sensitivity Voltage Divider Utilization Range Operating Temperature Signal diagram + Vin + Vout GND Note: The potentiometer must be connected as a voltage divider. The input impedance of the following processing circuit should be 10 MW min. Signal conditioner 10V Voltage output Excitation Voltage Excitation Current Output Voltage Output Current Output Load Stability (Temperature) Protection Output Noise Operating Temperature EMC +18 ... +27 V DC non stabilized 20 mA max. 0 ... +10 V DC 2 mA max. > 5 kW ±50 x 10-6 / °C full scale Reverse polarity, short circuit 0,5 mVRMS -20 ... +85 °C According to EN 61326:2004 Signal diagram 10V Excitation + Excitation GND Signal + 0...10 V Signal GND Signal Wiring Output signals R1K + Vin GND + Vout 10V Excitation + Excitation GND Signal + Signal GND Cable color White Brown Green Yellow Connector pin no. 1 2 3 4 Connection Mating Connector View to solder terminals CONN-DIN-8F-W CONN-M12-8F-G ASM www.asm-sensor.com CAT-WS-E-05 57 Output Specifications 420A and 420T for WS position sensors Excitation Voltage Signal conditioner 420A Current output (2 wire) Excitation Current Output Current Stability (Temperature) Protection Output Noise Operating Temperature EMC +12 ... 27 VDC non stabilized, measured at the sensor terminals 35 mA max. 4 ... 20 mA equivalent to 0 ... 100% range ±100 x 10-6 / °C full scale Reverse polarity, short circuit 0.5 mVRMS -20 ... +85 °C According to EN 61326:2004 Signal Diagram 420A Signal + 4...20 mA Signal – Signal Conditioner 420T Current output (3 wire) Excitation Voltage Excitation Current Load Resistor Output Current Stability (Temperature) Protection Output Noise Operating Temperature EMC +18...+27 V DC non stabilized 40 mA max. 350 W max. 4 ... 20 mA equivalent to 0 ... 100% range ±50 x 10-6 / °C full scale Reverse polarity, short circuit 0.5 mVRMS -20 ... +85 °C According to EN 61326:2004 Signal diagram 420T Excitation + Signal + 4...20 mA Excitation GND Signal Wiring Output signals 420A Signal + Signal – 420T Excitation + Excitation GND Signal + Cable color White Brown Green Connector pin no. 1 2 3 Connection Mating Connector View to solder terminals CONN-DIN-8F-W CONN-M12-8F-G 58 CAT-WS-E-05 www.asm-sensor.com ASM Output Specification PMU for WS position sensors Signal Conditioner PMU, adjustable Voltage output and current output (3 wire) Excitation voltage Excitation current Voltage output Output current Output load Current output Load resistor Adjustment Activation of offset and gain adjust Scalable range Stability (Temperature) Protection Output noise Operating temperature EMC +18 ... 27 V DC 50 mA max. 0 ... 10 V 10 mA max. 1 kW min. 4 ... 20 mA (3 wire) 500 W max. Connect with excitation GND (0 V) 90 % max. full scale ±50 x 10-6 / °C full scale Reverse polarity, short circuit 1 mVeff -20 ... +85 °C According to EN 61326:2004 Signal diagram Excitation + Excitation GND Signal 0...10 V + PMU Signal 0...10 V GND Signal 4...20 mA + Signal 4...20 mA GND Output signals Connector pin no. 1 2 3 4 5 6 7 8 Signal wiring Excitation + Excitation GND Signal 0...10 V + Signal 0...10 V GND Signal 4...20 mA + Signal 4...20 mA GND Offset Gain Connection Mating Connector View to solder terminals CONN-DIN-8F-W CONN-M12-8F-G ASM www.asm-sensor.com CAT-WS-E-05 59 Output Specification ADSI16 for WS position sensors · · · · Description Resolution 16 bit, data transmission synchronous serial/SSI Optional available with 12 bit (ADSI) or 14 bit (ADSI14) resolution No loss of data at power-down Easy to connect to PLC’s with SSI input circuit The sensing device of the ADSI is a precision potentiometer. The position information is given by an analog/digital converter output serialized as a data word. Data transmission takes place by means of the signals CLOCK and DATA. The processing unit (PLC, Microcomputer) sends pulse sequences which clock the data transmission with the required transfer rate. With the first falling edge of a pulse sequence the position of the sensor is recorded and stored. The following rising edges control the bit-by-bit A/D conversion, encoding and output of the data word. After a delay time the next new position information will be transmitted. Data Format (Train of 26 Pulses) Signal Conditioner ADSI A/D converted synchronous serial Output Excitation voltage Excitation current Clock frequency Code Delay between pulse trains Resolution Stability (temperature) Operation temperature EMC EIA RS-422, RS-485, short-circuit proof 11 ... 27 VDC 200 mA max. 70 ... 500 kHz Gray code, continuous progression T=30 µs min. 16 bit (65536 counts) full scale; optional 12 bit or 14 bit ±50 x 10-6 / °C full scale -20 ... +85 °C According to EN 61326:2004 Recommended Processing Input Circuit Sensor circuit Cable Subsequent circuit GND (0V) Cable length Baud rate < 300 kHz < 100 kHz Transmission rate < 50 m < 100 m Note: Extension of the cable length will reduce the maximum transmission rate. The signals CLOCK/CLOCK and DATA/DATA must be connected in a twisted pair cable, shielded per pair and common. Mating connector: view to solder terminals Signal names Connector pin no. 1 2 3 4 5 6 not connected Signal Wiring Excitation + Excitation GND (0V) CLOCK CLOCK DATA DATA Screen CONN-DIN-8F-W CONN-M12-8F-G ASM 64 CAT-WS-E-05 www.asm-sensor.com Output Specifications IE24LI and IE24HI for WS position sensors IE24LI and IE24HI incremental Excitation voltage Excitation current Output frequency Output Output current Output voltage Stability (temperature) Operation temperature Protection EMC IE24LI IE24HI 5 V DC ±10 % 10 … 30 V DC 100 mA max. 200 kHz Push-pull and inverted signals 10 mA max. Depending on the excitation voltage ±20 x 10-6 / °C f.s. (sensor mechanism) -20 … +85 °C Short circuit According to EN 61326:2004 Output signals Excitation + Excitation GND Signal A Encoder IE24LI IE24HI Signal A Signal B Signal B Signal Z (reference pulse) Signal Z Output circuit and recommended processing input circuit Output signals Cable color Brown White Grey Green Pink Yellow Blue Red Connector pin no. 1 2 3 4 5 6 7 8 Signal wiring Excitation + Excitation GND Signal B (A + 90°) Signal A Signal B Signal A Signal Z (reference pulse) Signal Z Connection Mating connector View to solder terminals CONN-DIN-8F-W 60 CAT-WS-E-05 www.asm-sensor.com CONN-M12-8F-G ASM Output Specification PP530 for WS position sensors Signal Conditioner PP530 Incremental Excitation Voltage Excitation Current Output Frequency Output Output Current Output Voltage Stability (Temperature) Operation Temperature Storage Temperature Transition Time Positive Edge Transition Time Negative Edge Protection EMC +5 ... +30 VDC 200 mA max. 200 kHz max. Linedriver, Push-Pull, CMOS, TTL and HTL compatible 30 mA max., short circuit protection Depends on the excitation voltage (e.g. to obtain TTL-signals the excitation must be 5 V.) Compatible to EIA RS-422/RS-485 ±20 x 10-6 / K full scale (sensor mechanism) -10 ... +70 °C -30 ... +80 °C 250 ns 250 ns Reverse polarity, short circuit According to EN61326:2004 Signal Diagram Excitation + Excitation GND Signal A Encoder PP530 Signal A Signal B Signal B Signal Z (Reference pulse) Signal Z Recommended Processing Circuit Excitation Level UaHigh UaLow UaHigh UaLow Signal Levels Ia £ 5 mA >4.2 V 23.5 V 4.2 V 23.5 V 4.1 V 23.5 V 3.8 V 22.5 V
WS10-1250-10V 价格&库存

很抱歉,暂时无法提供与“WS10-1250-10V”相匹配的价格&库存,您可以联系我们找货

免费人工找货