0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
WS17KT-2500-ADSI-L05

WS17KT-2500-ADSI-L05

  • 厂商:

    ASM-SENSOR

  • 封装:

  • 描述:

    WS17KT-2500-ADSI-L05 - analog or SSI output - ASM GmbH

  • 数据手册
  • 价格&库存
WS17KT-2500-ADSI-L05 数据手册
Model WS17KT with analog or SSI output Compact sensor for medium ranges · Protection class IP64 · Measurement ranges: 0 ... 1500 mm to 0 ... 15000 mm · Analog output 0 … 10 V, 4 … 20 mA, potentiometer or A/D converted synchronous serial output (SSI) Outputs Specifications Resolution Material Sensing Device Connector Linearity Protection class Weight Environmental EMC Temperature Potentiometer: 1 kW Voltage: 0...10 V Current: 4...20 mA, 2 or 3 wire Voltage and current output, adjustable A/D converted synchronous serial max. 16 bit (SSI) Essentially inifinite / ADSI16: max. 16 bit full scale Aluminium and stainless steel Cable: stainless steel Precision potentiometer Male socket 8 pin (M12 or DIN 45326) Up to ±0.05 % full scale IP64 See table next page Refer to output specification Refer to output specification Order Code WS17KT Analog or SSI WS17KT Model Name Measurement Range (in mm) 1500 / 2000 / 2500 / 3000 / 4000 / 5000 / 6250 / 10000 / 12500 / 15000 Outputs (see pages 57 ff.) R1K = Potentiometer 1 kW (other values on request) 10V = with 0 ... 10 V signal conditioner 420A = with 4 ... 20 mA signal conditioner (2 wire) 420T = with 4 ... 20 mA signal conditioner (3 wire) PMU = with 0...10 V/4 … 20 mA signal conditioner, adjustable ADSI = with A/D converted synchronous serial output 16 bit (option: 12, 14 bit) Linearity L10 = ±0.10 % option: L05 = ±0,05 % L25 = ±0.25 % Cable fixing M4 = M4 cable fixing SB0 = Cable clip Connection M12 = 8 pin socket M12 D8 = 8 pin socket DIN 45326 Order Code Mating Connector (see accessories p. 82) D8: CONN-DIN-8F-W M12: CONN-M12-8F-G Order Example: WS17KT - 2500 - 10V - L10 - M4 - M12 16 CAT-WS-E-05 www.asm-sensor.com ASM Model WS17KT with analog or SSI output Range [mm] 1500 2000 2500 3000 4000 5000 6250 10000 12500 15000 Weight (approx.) [kg] 1.4 1.4 1.5 2.9 2.9 5.3 5.5 6.0 6.0 6.0 Maximum pull-out force [N] 11.0 8.5 5.5 14.5 12.7 13.0 10.2 16.5 16.5 16.5 Minimum pull-in force [N] 6.2 4.8 3.5 10.3 9.1 9.3 7.3 9.1 9.1 9.1 Cable Forces and Weights typical at 20 °C Outline drawing WS17KT-1500 / 2000 / 2500 Dimensions informative only. For guaranteed dimensions consult factory Range A 17.5 9.5 2.5 Dimensions (mm) 1500 2000 2500 ASM www.asm-sensor.com CAT-WS-E-05 17 Model WS17KT with analog or SSI output Outline drawing WS17KT-3000 / 4000 Range A 105 120 Dimensions [mm] Dimensions informative only. For guaranteed dimensions consult factory 3000 4000 Outline drawing WS17KT-5000 / 6250 Range A 178 198 Dimensions [mm] 18 CAT-WS-E-05 5000 6250 www.asm-sensor.com ASM Model WS17KT with analog or SSI output Outline drawing WS17KT-10000 / 12500 / 15000 Dimensions informative only. For guaranteed dimensions consult factory ASM www.asm-sensor.com CAT-WS-E-05 19 Output Specifications R1K and 10V for WS position sensors Excitation Voltage Voltage divider R1K Potentiometer 32 VDC max. at 1 kW (input power 1 W max.) 1 kW ±10% ±25 x 10-6/ °C full scale Depends on measurement range, individual sensitivity of sensor specified on label Approx. 3% ... 97% of full range -20 ... +85 °C Potentiometer Impedance Thermal coefficient Sensitivity Voltage Divider Utilization Range Operating Temperature Signal diagram + Vin + Vout GND Note: The potentiometer must be connected as a voltage divider. The input impedance of the following processing circuit should be 10 MW min. Signal conditioner 10V Voltage output Excitation Voltage Excitation Current Output Voltage Output Current Output Load Stability (Temperature) Protection Output Noise Operating Temperature EMC +18 ... +27 V DC non stabilized 20 mA max. 0 ... +10 V DC 2 mA max. > 5 kW ±50 x 10-6 / °C full scale Reverse polarity, short circuit 0,5 mVRMS -20 ... +85 °C According to EN 61326:2004 Signal diagram 10V Excitation + Excitation GND Signal + 0...10 V Signal GND Signal Wiring Output signals R1K + Vin GND + Vout 10V Excitation + Excitation GND Signal + Signal GND Cable color White Brown Green Yellow Connector pin no. 1 2 3 4 Connection Mating Connector View to solder terminals CONN-DIN-8F-W CONN-M12-8F-G ASM www.asm-sensor.com CAT-WS-E-05 57 Output Specifications 420A and 420T for WS position sensors Excitation Voltage Signal conditioner 420A Current output (2 wire) Excitation Current Output Current Stability (Temperature) Protection Output Noise Operating Temperature EMC +12 ... 27 VDC non stabilized, measured at the sensor terminals 35 mA max. 4 ... 20 mA equivalent to 0 ... 100% range ±100 x 10-6 / °C full scale Reverse polarity, short circuit 0.5 mVRMS -20 ... +85 °C According to EN 61326:2004 Signal Diagram 420A Signal + 4...20 mA Signal – Signal Conditioner 420T Current output (3 wire) Excitation Voltage Excitation Current Load Resistor Output Current Stability (Temperature) Protection Output Noise Operating Temperature EMC +18...+27 V DC non stabilized 40 mA max. 350 W max. 4 ... 20 mA equivalent to 0 ... 100% range ±50 x 10-6 / °C full scale Reverse polarity, short circuit 0.5 mVRMS -20 ... +85 °C According to EN 61326:2004 Signal diagram 420T Excitation + Signal + 4...20 mA Excitation GND Signal Wiring Output signals 420A Signal + Signal – 420T Excitation + Excitation GND Signal + Cable color White Brown Green Connector pin no. 1 2 3 Connection Mating Connector View to solder terminals CONN-DIN-8F-W CONN-M12-8F-G 58 CAT-WS-E-05 www.asm-sensor.com ASM Output Specification PMU for WS position sensors Signal Conditioner PMU, adjustable Voltage output and current output (3 wire) Excitation voltage Excitation current Voltage output Output current Output load Current output Load resistor Adjustment Activation of offset and gain adjust Scalable range Stability (Temperature) Protection Output noise Operating temperature EMC +18 ... 27 V DC 50 mA max. 0 ... 10 V 10 mA max. 1 kW min. 4 ... 20 mA (3 wire) 500 W max. Connect with excitation GND (0 V) 90 % max. full scale ±50 x 10-6 / °C full scale Reverse polarity, short circuit 1 mVeff -20 ... +85 °C According to EN 61326:2004 Signal diagram Excitation + Excitation GND Signal 0...10 V + PMU Signal 0...10 V GND Signal 4...20 mA + Signal 4...20 mA GND Output signals Connector pin no. 1 2 3 4 5 6 7 8 Signal wiring Excitation + Excitation GND Signal 0...10 V + Signal 0...10 V GND Signal 4...20 mA + Signal 4...20 mA GND Offset Gain Connection Mating Connector View to solder terminals CONN-DIN-8F-W CONN-M12-8F-G ASM www.asm-sensor.com CAT-WS-E-05 59 Output Specification ADSI16 for WS position sensors · · · · Description Resolution 16 bit, data transmission synchronous serial/SSI Optional available with 12 bit (ADSI) or 14 bit (ADSI14) resolution No loss of data at power-down Easy to connect to PLC’s with SSI input circuit The sensing device of the ADSI is a precision potentiometer. The position information is given by an analog/digital converter output serialized as a data word. Data transmission takes place by means of the signals CLOCK and DATA. The processing unit (PLC, Microcomputer) sends pulse sequences which clock the data transmission with the required transfer rate. With the first falling edge of a pulse sequence the position of the sensor is recorded and stored. The following rising edges control the bit-by-bit A/D conversion, encoding and output of the data word. After a delay time the next new position information will be transmitted. Data Format (Train of 26 Pulses) Signal Conditioner ADSI A/D converted synchronous serial Output Excitation voltage Excitation current Clock frequency Code Delay between pulse trains Resolution Stability (temperature) Operation temperature EMC EIA RS-422, RS-485, short-circuit proof 11 ... 27 VDC 200 mA max. 70 ... 500 kHz Gray code, continuous progression T=30 µs min. 16 bit (65536 counts) full scale; optional 12 bit or 14 bit ±50 x 10-6 / °C full scale -20 ... +85 °C According to EN 61326:2004 Recommended Processing Input Circuit Sensor circuit Cable Subsequent circuit GND (0V) Cable length Baud rate < 300 kHz < 100 kHz Transmission rate < 50 m < 100 m Note: Extension of the cable length will reduce the maximum transmission rate. The signals CLOCK/CLOCK and DATA/DATA must be connected in a twisted pair cable, shielded per pair and common. Mating connector: view to solder terminals Signal names Connector pin no. 1 2 3 4 5 6 not connected Signal Wiring Excitation + Excitation GND (0V) CLOCK CLOCK DATA DATA Screen CONN-DIN-8F-W CONN-M12-8F-G ASM 64 CAT-WS-E-05 www.asm-sensor.com
WS17KT-2500-ADSI-L05 价格&库存

很抱歉,暂时无法提供与“WS17KT-2500-ADSI-L05”相匹配的价格&库存,您可以联系我们找货

免费人工找货