WS19KK Position Sensor with Absolute or Incremental Encoder
Position Sensor with Heavy-Duty Encoder
· Protection Class IP64 · Measurement Range: 0 ... 2000 mm up to 0 … 15000 mm 0 … 78.74 in up to 0 … 590.55 in · With Absolute or Incremental Encoder Output
Optional:
Outputs
Specifications
Multiturn encoder with synchronous serial interface TSSI (-P) with 12 (13) bit resolution Incremental encoder with HTL output 0...30 V or Line Driver 5V WS19KK-2000: WS19KK-3000: WS19KK-5000: WS19KK-8000: WS19KK-15000 mm: 0.04 (0.02) mm / 25 pulses 0.063 (0.0315) mm / 15.75 pulses 0.10 (0.05) mm / 10 pulses 0.162 (0.0815) mm / 6.13 pulses 0.146 (0.073) mm / 6.83 pulses
Resolution for TSSI (-P) / pulses per mm for PP24V, LD5V
Material Sensing Device Connector Linearity Protection Class (IEC 529) Weight Environmental Immunity to Interference (EMC) Temperature
Aluminium, stainless steel and plastic. Cable: Stainless Steel Absolute Multiturn or Incremental Encoder 12 pin (incremental) or 17 pin socket (TSSI) ±0.05 % full scale, optional ±0.01 % full scale IP64 See table next page Refer to output specification Refer to output specification
Order Code WS19KK
Model Name
WS19KK
Measurement Range (in mm) 2000 (smaller measurement ranges included) / 3000 / 5000 / 8000 / 15000 Outputs TSSI = Multiturn encoder with synchronous serial output TSSI-P = Programmable TSSI with SSI, RS-232 and incremental output PP24VC = Incremental encoder with HTL Output 10-30 V LD5VC = Incremental encoder with Linedriver Output 5 V Other outputs on request (Interbus S, Profibus, CAN-Bus) Linearity L01 = ±0.01 % related to the specified sensitivity on the label Option M4 = M4 cable fixing
Order Code Mating Conn. (see accessories p. 105) WS11-CONN-12P For TSSI: WS-CONN-017S-M Order Example: WS19KK - 5000 - TSSI - M4
40 CAT-POS-E-2001 ASM
WS19KK Position Sensor with Absolute or Incremental Encoder
Cable Forces and Weights typical at 20 °C
Range [mm] [in] 2000 3000 5000 8000 15000 78.74 118.11 196.85 314.96 590.55
Weight [kg] 1.5 1.7 3.2 6.8 7.3
Maximum Pull-out Force [N] 11.0 8.0 13.1 10.0 17.5
Minimum Pull-in Force [N] 6.2 4.1 8.6 7.0 7.5
Outline drawing WS19KK-2000 / 3000
Output PP24V, LD5V TSSI TSSI-P
Dim. L [mm] 53 70 70
Range [mm] 2000 3000
Dim. A [mm] 11,5 0
For guaranteed dimensions consult factory
ASM
CAT-POS-E-2001
41
WS19KK Position Sensor with Absolute or Incremental Encoder
Outline drawing WS19KK-5000
For guaranteed dimensions consult factory
Output PP24V, LD5V TSSI TSSI-P
Dim. L [mm] 53 70 70
Outline drawing WS19KK-8000
Output
For guaranteed dimensions consult factory
Dim. L [mm] 53 70 70
PP24V, LD5V TSSI TSSI-P
42
CAT-POS-E-2001
ASM
WS19KK Position Sensor with Absolute or Incremental Encoder
Outline drawing WS19KK-15000
Output PP24V, LD5V TSSI TSSI-P
Dim. L [mm] 53 70 70
Verbindliche Zeichnungen bitte vom Werk anfordern
ASM
CAT-POS-E-2001
43
Output Specifications PP24VC and LD5VC for WS position sensors
PP24VC Incremental
Output Excitation voltage Excitation current Output frequency Output current Signal level Ud High at Id=20 mA, Ub=24 V Ud Low at Id=20 mA, Ub=24 V Transition time positive edge Transition time negative edge Stability (Temperature) Operation temperature Protection EMC)
Push-pull line driver (24 V - HTL) 10 ... 30 V DC 150 mA max. w/o load 300 kHz max. 100 mA per channel ³21 V £2,8 V < 200 ns < 200 ns ±20 x 10-6 / °C full scale (sensor mechanism) -20 ... +85 °C Short circuit (max. 1 min.), overvoltage, reverse pol. According to EN 61326:2004 Line driver according to RS-422 5 V DC ± 10% 150 mA max. w/o load 300 kHz max. 20 mA per channel ³2,5 V £0,5 V < 100 ns < 100 ns ±20 x 10-6 / °C full scale (sensor mechanism) -20 ... +85 °C Short circuit, overvoltage According to EN 61326:2004
LD5VC Incremental
Output Excitation voltage Excitation current Output frequency Output current Signal level Ud High at Id=20 mA Ud Low at Id=20 mA Transition time positive edge Transition time negative edge Stability (Temperature) Operation temperature Protection EMC
Output circuit and recommended processing input circuit
LD5VC
PP24VC
Output signals and output connectors
Signal wiring and connection
Output signals (Note: Do not connect pins not listed in this table)
Excitation + Excitation GND (0V) Signal A Signal A Signal B Signal B Signal Z (reference pulse) Signal Z Fault detection signal Uas Shield
CONN-CONIN-12F-G
12 10 5 6 8 1 3 4 7 Housing
62
CAT-WS-E-05
www.asm-sensor.com
ASM
WS Position Sensors Output Specification TSSI
· 4096 counts per revolution (12 bit), 4096 revolutions (12 bit) · No Loss of Data at Power-down · Easy to Connect to PLC’s with SSI Input Circuit Description
The sensing device of the SSI is a 24-bit absolute multiturn encoder. The position information is given by an analog/digital converter output serialized as a data word. The processing unit (PLC, Microcomputer) sends pulse sequences which clocks the data transmission at the required transfer rate. With the first falling edge of the pulse sequence the position of the sensor is recorded and stored. The following rising edges control the bit-by-bit transmission of the data word. After a delay time the next new position information
Data Format (Train of 26 pulses)
Output
EIA RS-422, RS-485, short-circuit proof 10 ... 30 V DC, reverse polarity protected 250 mA max. without load 100 kHz ... 1 MHz Gray, continuous progression Tannenbaum 12 to 35 µs ±0.002% / K Full Scale (sensor mechanism) -20 ... +85 °C According to EN50082-2, EN50081-1
Signal Conditioner TSSI Absolute Encoder synchronous serial
Excitation Voltage Excitation Current Clock Frequency Code Format Delay between Pulse Trains Stability (Temperature) Operation Temperature Immunity to Interference (EMC)
Recommended Processing Input Circuit
Sensor Circuit
Cable
Subsequent Circuit
Cable Length 50 m 100 m
Baud Rate 100 … 1000 kHz 100 … 300 kHz
Note: Extension of the cable length will reduce the maximum transmission rate. The signals CLOCK/CLOCK and DATA/DATA must be connected in a twisted pair cable, shielded per pair and common.
Connector Pin 7 10 8 9 14 17
Signal Name
Cable Output (*) white brown green yellow grey pink
Signal Wiring / Connection
Excitation + Excitation GND (0V) CLOCK CLOCK DATA DATA
(*) WS7.2 only
ASM
CAT-POS-E-2001
89
WS Position Sensors Output Specification TSSI-P
· 8192 counts per revolution (13 bit), 4096 revolutions (12 bit) · Encoder programming and data transfer via RS-232 interface · In addition sinusoidal incremental signals Description
The sensing device of the SSI is a 25-bit absolute multiturn encoder. The position information is given by an analog/digital converter as a serial data word. The processing unit (PLC, Microcomputer) sends pulse sequences which clocks the data transmission at the required transfer rate. With the first falling edge of the pulse sequence the position of the sensor is recorded and stored. The following rising edges control the bit-by-bit transmission of the data word. After a delay time the next new position information will be transmitted.
Data Format (Train of 26 pulses)
Output
EIA RS-422, RS-485, short-circuit proof 10 ... 30 V DC, reverse polarity protected 250 mA max. without load 100 kHz ... 1 MHz Resolution, Offset, Preset, Counting Direction, Output Code and Format Gray or Binary Tannenbaum (SSI) or Serial, right aligned 12 to 35 µs Two sinusoidal quadrature signals A and B, each with 512 periods per revolution. Signal amplitude approx. 1 Vss with 120 W terminating resistance RS-232C asynchronous (TxD, RxD, GND) for encoder programming and data transmission Preset1, Preset2, Counting Direction 002% / K Full Scale (sensor mechanism) -20 ... +85 °C According to EN50082-2, EN50081-1
Signal Conditioner TSSI Absolute Encoder synchronous serial, programmable
Excitation Voltage Excitation Current Clock Frequency Programmable Functions Code Format Delay between Pulse Trains Incremental Signal
Serial Interface Hardware Programming Stability (Temperature) Operation Temperature Immunity to Interference (EMC)
Signal Name
Connector Pin 7 10 8 9 14 17 15 16 12 13 11 1 4 3 5 6 2
Signal Wiring / Connection
Excitation + Excitation GND (0V) CLOCK CLOCK DATA DATA Signal A Signal A Signal B Signal B Internal shield RxD TxD Fault detection signal UaS Preset1 Preset2 Counting direction
Programming Software and Connector Cable see page 104.
90
CAT-POS-E-2001
ASM
WS Position Sensors Output Specification TSSI-P
Recommended Processing Input Circuit
Sensor Circuit
Cable
Subsequent Circuit
Cable Length 50 m 100 m
Baud Rate 100 … 1000 kHz 100 … 300 kHz
Note: Extension of the cable length will reduce the maximum transmission rate. The signals CLOCK/CLOCK and DATA/DATA must be connected in a twisted pair cable, shielded per pair and common.
Incremental Signals
ASM
CAT-POS-E-2001
91