0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AUK10G48

AUK10G48

  • 厂商:

    ASTEC

  • 封装:

  • 描述:

    AUK10G48 - Ultra Low Profile DC - DC Module (Pb-free reflow compatible and ROHS Compliant) - Astec A...

  • 详情介绍
  • 数据手册
  • 价格&库存
AUK10G48 数据手册
Technical Reference Note Ultra Low Profile AUK 30W Series AUK 30W Ultra Low Profile DC – DC Module (Pb-free reflow compatible and ROHS Compliant) The AUK 30W series is Astec’s new Ultra Low Profile, 48Vin, SMT isolated single output modules. With the Ultra Low Profile SMT design (only 4.4mm height), the module can be flexible mounted on the top side or the bottom side of motherboard. The AUK 30W series also comes with enhanced features such as Remote on/off (RC), parallel Application (PO), Power Good (ALM), and the protection of OVP, OCP and UVLO. Electrical Parameters Input Input range Efficiency 36 – 75Vdc 91% @5Vo Control Enable ON: RC pin connected to –Vin or Open OFF: RC pin connected to +Vin Output Line / Load Regulation Ripple and Noise OVP OCP +5%, -3% 50mVp-p 120% of Vonom (Latch-up) 11.3A for 1.5V, 1.8V 10.3A for 2.5V 9.3A for 3.3V 6.2A for 5.0V 90% of Vonom (Latch-up) 1500VDC (1 minute) Special Features • • • • • • • • • • Ultra Low Profile – 4.5mm height Efficiency – 91% @ 5V -40 °C to +85°C Ambient Operating temperature (0.2m/s air flow) Open Frame SMT Low output ripple and noise Regulation to zero load CISPR22, Class A for Conduct and Radiated EMI Parallel Application UL/cUL 60950, CE Mark Pb-free reflow compatible and ROHS Compliant LVP Isolation MODEL : AUK 30W SERIES April 05 REVISION 02 SHEET 1 OF 15 Technical Reference Note Ultra Low Profile AUK 30W Series AUK 30W Ultra Low Profile Series THIS SPECIFICATION COVERS THE REQUIREMENTS MODEL NAME AUK11M48 AUK11Y48 AUK10G48 AUK09F48 AUK06A48 SIS CODE AUK11M48 AUK11Y48 AUK10G48 AUK09F48 AUK06A48 Vout,Iout 1.5V @ 11A 1.8V @ 11A 2.5V @ 10A 3.3V @ 9A 5V @ 6A MODEL : AUK 30W SERIES April 05 REVISION 02 SHEET 2 OF 15 Technical Reference Note Ultra Low Profile AUK 30W Series Electrical Specifications STANDARD TEST CONDITION on a single unit, unless otherwise specified. T A: 25°C (Ambient Air) +Vin (P13-15): 36 – 75Vdc -Vin (P9-11): Return for +Vin RC (P5): Open +Vo (P20 - 23): Connect to load -Vo (P24 - 29): Return for +Vo PO (P7):Open ALM(P3): Open ABSOLUTE MAXIMUM RATINGS Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. Functional operation of the device is not implied at these or in any other conditions in excess of those given in the operational sections of the specs. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Parameter Input Voltage Continuous Transient (200µs, 42V/10/µs rate) Operating Temperature (0.2m/s sir flow) Storage Temperature Operating Humidity INPUT SPECIFICATIONS Parameter Operating Input Voltage Turn-on Voltage Turn-off Voltage Maximum Input Current2 (VIN = 0 to VIN,max; IO = IO,max) Device Symbol VIN Min 36 32 30 Typ 48 Max 75 36 34 Unit Vdc Vdc Vdc All All TSTG Device Symbol VIN VIN,trans Min 36 -40 Typ Max 75 90 85 Unit Vdc Vdc ºC -40 10 - 90 95 ºC % All IIN,max - - 1.5 A Note: 1. This power module is not internally fused. The use of an input line fuse (GMA-10A Bussman fuse or equivalent) is recommended. 2. The value is static only and rated for UL/cUL safety. In-rush current to charge internal capacitors is not specified. MODEL : AUK 30W SERIES April 05 REVISION 02 SHEET 3 OF 15 Technical Reference Note Ultra Low Profile AUK 30W Series OUTPUT SPECIFICATIONS Parameter Output Voltage Setpoint (VIN=VIN,min to VIN,max at IO=IO,max) Device AUK11M48 AUK11Y48 AUK10G48 AUK09F48 AUK06A48 Symbol VO,SET VO,SET VO,SET VO,SET VO,SET Min Typ 1.5 1.8 2.5 3.3 5.0 Max Unit Vdc Vdc Vdc Vdc Vdc Output Regulation: Line: VIN=VIN,min to VIN,max Load: IO=IO,min to IO,max Output Ripple and Noise Peak to Peak: 5Hz to 20MHz Output Current Range All All - -3 -3 - +5 +5 % % All 1.5V 1.8V 2.5V 3.3V 5.0V 1.5V 1.8V 2.5V 3.3V 5.0V All All IO IO IO IO IO IO IO IO IO IO 0 0 0 0 0 - 11.3 11.3 10.3 9.3 6.2 120 90 50 11 11 10 9 6 - mVPK-PK A A A A A A A A A A %Vo %Vo Output Current Limit Inception3 Over Voltage Protection Low Voltage Protection Efficiency Ta = 25ºC. Vin =48V, Io=Iomax 1.5V 1.8V 2.5V 3.3V 5.0V η η η η η 80 81 84 85 86 85 86 89 90 91 - % % % % % Note: 3. This feature is only for module protection and is not intended for customer application. The value is specified at 25C ambient air temperature. MODEL : AUK 30W SERIES April 05 REVISION 02 SHEET 4 OF 15 Technical Reference Note Ultra Low Profile AUK 30W Series OUTPUT SPECIFICATIONS (Continued) Parameter Switching Frequency Device 1.5V 1.8V 2.5V 3.3V 5.0V Symbol Min Typ 530 530 530 530 530 Max Unit KHz KHz KHz KHz KHz Dynamic Response: Slew Rate Load Change: 50% - 100% IO,max Load Change: 100% to 50% IO,max Turn-On time (Input to Output)5 IO = Iomax; VIN = VIN,nom to VO,nom All All All All ∆IO/∆t - 15 0.3 x Io / 100uS - 10 10 250 A/µs %VO %VO ms Note: 5. Input to Output Turn-On time is defined as the difference between t1 and t2: where t1 is the time when the input voltage reaches the minimum VIN (VIN = VIN,MIN) and t2 is the time when the output voltage reaches it's specified range (VO = VO,SET-Min). ISOLATION SPECIFICATION Input to Output Isolation: 1500Vdc (1 minute) SAFETY APPROVAL The AUK (30W) is certified under the following agencies: • UL/cUL 60950, and CE Mark. The module shall not be considered approved and carry safety agency logos until this has been authorized by Safety and QA / QC management. MODEL : AUK 30W SERIES April 05 REVISION 02 SHEET 5 OF 15 Technical Reference Note Ultra Low Profile AUK 30W Series Basic Operation and Features Over Current Limit Inception (OCP) The Isolated DC-DC converter limits output current when the current is over the maximum output current due to abnormality such as overload or short circuit. When over current condition continues and output voltage decreases to the point of low voltage protection, the DC-DC converter will be in latch up mode. To restore the output, remove the abnormality and re-set the input voltage under 5V for 1 second minimum. Over Voltage Protection (OVP) The Isolated DC-DC converter stops the operation when the output voltage is over the specified Over Voltage Protection point, the converter will be in latch up mode after 0.5ms*. To restore the output, re-set the input voltage under 5V for 1 second minimum. Notes*: Output voltage might exceed the point at which OVP starts to function under the specific condition of transient input voltage or output current change. Therefore, OVP is set to wait for the mask time 0.5ms. Low Voltage Protection (LVP) If output voltage is under the specified Low Voltage Protection point, the converter will halt the operation. After typical 500ms mask period, the converter will be in latch up mode. To restore the output, re-set the input voltage under 5V for 1 second minimum. Remote On/Off Control (RC) If RC pin is open or connected to –Vin, the converter is turned on. If RC is connected to +Vin, the converter is turned off. Alarm Output (ALM) The Alarm output will be down to the –Vin level (Open Drain Output) at the condition of Over Voltage Protection or Low Voltage Protection. The maximum sink current in ALM pin is 10mA. When operating in parallel application, all operating units can be simultaneously halt by connecting all the ALM pins together, in the condition of Over Voltage Protection or Low Voltage Protection caused by any single converter. Maximum number for parallel operation is 10 units Synchronous Turn On/Off Connect the PO (parallel Operation) pins of all operating units together will synchronize the turn on / off time in parallel application. MODULE PIN ASSIGNMENT PIN # P1, 2, 16, 17, 18, 19, 33, 34 P20, 21, 22, 23 P24, 25, 26, 27, 28, 29 P3 P5 P7 P6 P13, 14, 15 P9, 10, 11 DESIGNATION NC +Vo -Vo ALM RC PO NC +Vin -Vin Mechanical supplemental contact pins + Output - Output Alarm Output Remote On/Off Parallel Operation + Input - Input MODEL : AUK 30W SERIES April 05 REVISION 02 SHEET 6 OF 15 Technical Reference Note Ultra Low Profile AUK 30W Series Performance Curves Ef f iciency at 25C 100 80 Efficiency (%) V in=36V 60 40 20 0 0 2 4 6 Iout (A ) 8 10 V in=48V V in=60V V in=75V Efficiency at 25C 100 Efficiency (%) 80 60 40 20 0 0 2 4 6 Iout (A) 8 10 Vin=36V Vin=48V Vin=60V Vin=75V Efficiency vs. Load Current Curves for 1.5Vo Efficiency at 25C 100 Efficiency (%) Vin=36V Vin=48V Vin=60V Vin=75V Efficiency vs. Load Current Curves for 1.8Vo Efficiency at 25C 100 Efficiency (%) 80 60 40 20 0 Vin=36V Vin=48V Vin=60V Vin=75V 80 60 40 20 0 0 2 4 6 8 10 Iout (A) 0 2 4 Iout (A) 6 8 Efficiency vs. Load Current Curves for 2.5Vo Ef f ic iency at 25C 100 Efficiency (%) 80 60 40 20 0 0 2 Iout (A ) 4 6 V in=36V V in=48V V in=60V V in=75V Efficiency vs. Load Current Curves for 3.3Vo Efficiency vs. Load Current Curves for 5.0Vo MODEL : AUK 30W SERIES April 05 REVISION 02 SHEET 7 OF 15 Technical Reference Note Ultra Low Profile AUK 30W Series AUK Power derating 75C 100 75 Output (%) 70% at 85C 50 Air V = 0m/s Air V=0.2m/s 25 0 -40 -20 0 20 40 60 80 Ambient Temp (C) Derating Curve for the AUK 30W Series MODEL : AUK 30W SERIES April 05 REVISION 02 SHEET 8 OF 15 Technical Reference Note Ultra Low Profile AUK 30W Series Typical Application Circuit A) Single Operation GND -48V Fuse SW +Vin -Vin -PO RC ALM +Vout -Vout Load SW Open : Enable DC-DC converter Figure 1 B) Parallel Operation (A single power supply connects to multiple DC-DC converters to apply for higher output current more than rated one from a DC-DC converter) GND -48V Fuse SW +Vin -Vin -PO RC ALM +Vout -Vout Load +Vin -Vin -PO RC ALM SW Close : Halt all DC-DC converter with RC connected together Maximum units in parallel: 10pcs +Vout -Vout Figure 2 i) All PO pins should be connected together ii) All DC-DC converters with ALM pins connected will stop the operation when one single converter is halted in mode protected by LVP or OVP. iii) LED is optionally connected to ALM pin for the notice of DC-DC converter stoppage. MODEL : AUK 30W SERIES April 05 REVISION 02 SHEET 9 OF 15 Technical Reference Note Ultra Low Profile AUK 30W Series C) Multiple Operation: A single power supply connects to multiple DC-DC converters to individually distribute output current to multiple independent loads. GND -48V Fuse SW +Vin -Vin PO RC ALM +Vout -Vout Load +Vin -Vin PO RC SW Close : Halt all DC-DC converter with RC connected together +Vout -Vout Load ALM Figure 3 i) All DC-DC converters with ALM pins connected will stop the operation when one single converter is halted in mode protected by LVP or OVP. ii) LED is optionally connected to ALM pin for the notice of DC-DC converter stoppage. MODEL : AUK 30W SERIES April 05 REVISION 02 SHEET 10 OF 15 Technical Reference Note Ultra Low Profile AUK 30W Series D) complex parallel and multiple (Sequence start-up): Two converters supplying the same output voltage for a single load and another converter supplying the different output voltage for another load. Converter No.1 GND -48V Fuse SW2 SW1 +Vin -Vin PO RC ALM +Vout -Vout Load Converter No.2 +Vin -Vin PO RC ALM +Vout -Vout Converter No.3 +Vin -Vin PO RC ALM +Vout -Vout Load SW1 Close : Halt DC-DC converter No.1 and 2 SW2 Close : Halt DC-DC converter No.3 Figure 4 i) PO pins of the converters supplying the same output voltage are connected to the others and another PO pin of the different output voltage converter is not connected. ii) All three DC-DC converters, which are connected to ALM pins, stop their operation when a single one is halted in mode protected by LVP or OVP. iii) LED is optionally connected to ALM pin for the notice of DC-DC converter stoppage. MODEL : AUK 30W SERIES April 05 REVISION 02 SHEET 11 OF 15 Technical Reference Note Ultra Low Profile AUK 30W Series Mechanical Specifications Marking of No.1 pin 1 2 3 4 5 6 34 33 2.18+/-0.5 P=2.54+/-0.2 Tolerance is not accumulated. Unit : mm 06*S 29 ABC (2P) 7 28 27 26 25 24 23 22 21 INPUT=36-75VDC OUTPUT= H . J V K L A AUK E F G 48 9 10 (2P) 11 13 14 15 16 17 18 42.4+/-0.5 1.5+/-0.2 19 0.25+/-0.1 20 45+/-0.5 0 to 10deg 0.55 +0.1 -0.15 1.3+/-0.3 Enlarged pin shape 4.4Max 45.0+/-0.6 Coplanarity 0.1mm Max Pin No 1,2,16,17,18,19,33,34 20,21,22,23 24,25,26,27,28,29 9,10,11 13,14,15 Symbol NC +Vout -Vout -Vin +Vin Function Mechanical supplemental contact pins +Output -Output -Input +Input Pin No 3 4 5 6 7 Symbol ALM NC RC NC PO Function Alarm output Remote on/off control Parallel operation Notes: A : Factory symbol B : The last number of production year Example: 2 stands for 2002 C : Production month (1,2,3,..…,9,O, N, D) Unit Weight: 13.8g E,F G H,J K,L : Output current symbol : Output voltage symbol : Output voltage : Output current MODEL : AUK 30W SERIES April 05 REVISION 02 SHEET 12 OF 15 Technical Reference Note Ultra Low Profile AUK 30W Series PACKING AND SHIPPING Trays Tray Dimensions Unit : mm General tolerance : +-1.5 A P1 64.6 P1 by 3=193.8 B B' 300 274.5 P2 56.0 A• f P2 by 2 = 112 200 44.0 B-B' cross section 10.0 174.5 MODEL : AUK 30W SERIES April 05 REVISION 02 SHEET 13 OF 15 A-A'cross section 53.2 Technical Reference Note Ultra Low Profile AUK 30W Series Maximum pieces per a tray : 12pcs/tray Package Corrugated cardboard box contains trays with products. Tray is heaped with alternately opposite direction to prevent products from contacting against the bottoms of trays. Dummy tray Trays containing products Bottom sheet of corrugated cardboard Label ASTEC Products Corrugated cardboard box Numerals in parentheses are reference only. Unit : mm Label ; written by : Part Number, : Quantity, : Inspection Number, : CE Marking. MODEL : AUK 30W SERIES April 05 REVISION 02 SHEET 14 OF 15 Technical Reference Note Ultra Low Profile AUK 30W Series Reflow Soldering Information Soldering I) Flux Solder the products with Rosin Flux (0.2wt%. chloride or less). Do not use acid or soluble flux, because they may damage metallic parts and glass parts and may cause defective or reduce quality. II) Solder SnAgCu solder compatible III) Condition of Soldering – Recommended soldering profile (J-STD-020C): Reflow Profile : Infrared or air blow Preheating : 150 – 200 deg C for 60 to 150sec Peak temperature : 240 ± 5 deg C at surface. Maximum period above 220deg.C : 20 – 60sec Ramp rate : lower than 4 deg C / sec Times : Max 2 times (see below recommendation) . Recommendation Do not give vibration to products while solder melts under reflow process. Please handle to wait for products cooled down enough. Please don’t reflow a motherboard mounted the products on the lower side such as a below figure, because the products surely fall down from the motherboard. If need, we recommend to use supplemental mechanical contact to pins at four corners of a substrate by other adhesive methods, for example, a thermal setting resin rather than soldering. Motherboard Isolated DC-DC converter Recommend Storage Condition Maximum storage period: Storage condition: 6 months 30 deg C, 60%RH Recommend baking the module at 100degC for 24 hours if storage period is longer than 6 months. MODEL : AUK 30W SERIES April 05 REVISION 02 SHEET 15 OF 15
AUK10G48
PDF文档中的物料型号为LM4888SQ。

器件简介说明了LM4888SQ是一款具有高性能的音频功率放大器,特别适合于便携式设备。

引脚分配详细列出了引脚的功能和作用,包括电源、输出、输入和控制引脚。

参数特性提供了诸如供电电压范围、功耗、增益、带宽、失真和噪声等关键指标。

功能详解深入介绍了该放大器的工作原理和特点,包括高效率、低失真和高稳定性。

应用信息指出了LM4888SQ适用于便携式音频、家庭音响和汽车音响系统等多种应用。

封装信息说明了该器件采用的封装类型为SQ封装,便于在PCB上安装和布线。
AUK10G48 价格&库存

很抱歉,暂时无法提供与“AUK10G48”相匹配的价格&库存,您可以联系我们找货

免费人工找货