150 Watts
LPQ150 Series
Total Power: 110-150 Watts Input Voltage: 85-132 / 170-264 VAC 220-300 VDC # of Outputs: Quad
Electrical Specs
Input
Input range Frequency Inrush current Efficiency EMI filter 85-132 VAC or 170-264 VAC automatically selected. 220-300 VDC 47-63 Hz 38 A max, cold start @ 25°C 75% typical at full load Meets FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted 0.5 mA @ 50/60 Hz, 264 VAC input
Safety ground leakage current
Special Features
• • • • • • • • • • • Auto ranging input Remote sense on main output Remote inhibit Single wire current sharing Power fail Built-in EMI filter Low output ripple 135 khz switching frequency Overvoltage protection Overload protection Adjustable floating 4th output (On LPQ152 and LPQ153 models) • Optional cover (-C suffix). See page 64.
Output
Maximum power 110 W convection (75 W with cover) 150 W with 30 CFM forced air (130 W with cover) ±5% on main; 5-25 V on 4th output on LPQ 152 & LPQ 153 ±2% on output 1; ±3% on outputs 2, 3 &4 20 ms @110 W load at nominal line Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating 5.7-6.7 VDC on main output
Adjustment range Cross regulation Hold-up time Overload protection
Overvoltage protection
Environmental
Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C Electromagnetic susceptibility: designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity: Operating; non-condensing 5% to 95% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational Storage temperature: -40° to 85°C Temperature coefficient: ± .04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient condition
Logic Control
Power failure TTL logic signal goes high 50-150 msec after 5 V output. It goes low at least 3 msec before loss of regulation Requires an external TTL high signal to inhibit outputs Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.
Remote inhibit Remote sense
Safety
VDE UL CSA NEMKO CB CE 0805/EN60950 (IEC950) UL1950 CSA 22.2-234 Level 3 EN 60950/EMKO-TUE (74-sec) 203 Certificate and report Mark (LVD) 11774-3336-1260 (LC# 88585) EI32002 LR53982 P95102999 2061
rev 12.10.03
114
Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662
AMERICAS 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698
EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355
ASIA Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426
LPQ150 Series
Ordering Information
Model Number LPQ152 Output Voltage 5V 12 V -12 V ±5-25 V 5V 15 V -15 V ±5-25 V 5V 12 V -12 V 24 V Minimum Load 2A .1 A .1 A 0A 2A .1 A .1 A 0A 2A .1 A .1 A .5 A Maximum Load with Convection Cooling 15 A 6A 2A 2.5 A 15 A 4.8 A 1.6 A 2.5 A 15 A 6A 2A 3.5 A Maximum Load with 30 CFM Forced Air 22 A 8A 2.5 A 3A 22 A 6.4 A 2A 3A 22 A 8A 2.5 A 4.5 A Peak Load1 30 A 10 A 3A 3A 30 A 8A 2.4 A 3A 30 A 10 A 3A 5A ±2% ±3% ±3% ±3% ±2% ±3% ±3% ±3% ±2% ±3% ±3% +10 / -5% Regulation2 Ripple P/P (PARD)3 50 mV 120 mV 120 mV 240 mV, max. 50 mV 150 mV 150 mV 240 mV, max. 50 mV 120 mV 120 mV 240 mV
LPQ153
LPQ154
1. 2. 3. 4. 5.
Peak current lasting
很抱歉,暂时无法提供与“LPQ152”相匹配的价格&库存,您可以联系我们找货