Embedded Power for Business-Critical Continuity
LPS120 Series
120 Watts
Total Power: Input Voltage: # of Outputs: 80 - 130 Watts 85 - 264 VAC Single
Rev. 5.09.06 LPS120 Series 1 of 3
RoHS
Electrical Specifications
Special Features
• • • • • • • • • • • • • Active power factor correction 3" x 5" footprint Less than 1U high EN61000-3-2 compliant Remote sense Power fail and remote inhibit Single wire current sharing Adjustable main output Built-in Class B EMI filter Overvoltage protection Overload protection Thermal overload protection 5 V Standby output and 12V Fan output
Input
Input range Frequency Inrush current Efficiency EMI/RFI Power factor Safety ground leakage current 85 - 264 VAC ; 127 - 300VDC 47-440 Hz 40A max., cold start @ 25°C 80% typical at full load FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted 0.99 typical 0.5mA @ 50/60 Hz, 264 VAC input
Output
Maximum power Adjustment range Fan output Standby outputs Hold-up time Overload protection 80W for convection ; 130W with 30CFM forced air ±5% minimum on the main outputs 12V @ 500mA - 5%, +7% 5V @ 500mA ±5% 20ms @ 125W load, 120VAC input Short circuit protection on all outputs. Case overload protected @ 120-135% above rating Overvoltage protection 20-35% above nominal output Remote sense Compensates for 0.5 V lead drop max. Will operate without remote sense connected. Reverse connection protected. Logical Control Power failure TTL logic signal goes high 100-500 msec after main output; it goes low at least 4 msec before loss of regulation Requires a contact closure to disable the outputs, except 5V standby. Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.
Safety
TUV UL CSA NEMKO AUSTEL CB CE 60950 60950 60950 60950 60950 Certificate and report Mark (LVD)
Remote inhibit Remote sense
Embedded Power for Business-Critical Continuity
Rev. 5.09.06 LPS120 Series 2 of 3
Environmental Specifications
Operating temperature: 0° to 50°C ambient derate each output as 2.5% per degree from 50° to 70°C. -20°C start up
Mechanical Drawing
3.00 (76.2) 2.55 (64.8)
SK1
P1
Storage temperature: Electromagnetic susceptibility: Humidity: Vibration: MTBF demonstrated
-40°C to +85°C designed to meetEN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Operating; non-condensing 10% to 95% RH IEC68-2-6 to the levels of IEC721-3-2 >550,000 hours at full load and 25°C ambient conditions
0.15" DIA. 4 places (4.0)
LIVE
NEUTRAL
EARTH
4.55 (115.6)
5.00 (127.0)
V Adjust POT
SK3
1 5 6 10
2 SK2
1
M3.5 (2 places)
1.29 (32.8)
SK3
0.20" (5)
Embedded Power for Business-Critical Continuity
Ordering Information
Model Number LPS121 LPS122 LPS123 LPS124 LPS125 LPS128 Output Voltage 3.3V 5V 12V 15V 24V 48V Minimum Load 0A 0A 0A 0A 0A 0A Maximum Load with Convection Cooling 21A 16A 6.7A 5.3A 3.4A 1.7A Maximum Load with 300CFM Peak Load Regulation2 Forced Air 36A 26A 10.8A 8.7A 5.4A 2.7A 29A 29A 12.8A 10.0A 6.3A 3.2A ±2% ±2% ±2% ±2% ±2% ±2% Ripple P/P (PARD)3 50mV 50mV 120mV 150mV 240mV 480mV
Astec Power
Rev. 5.09.06 LPS120 Series 3 of 3
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Technical Support: +1 888 41 ASTEC or +1 407 241 2752 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Units 2111-2116, Level 21 Tower 1, Metroplaza 223, Hing Fong Road Kwai Fong, New Territories Hong Kong Telephone: +852 2437 9662 Facsimile: +852 2402 4426
1. Peak current lasting