FDC40-12D12

FDC40-12D12

  • 厂商:

    ASTRODYNE

  • 封装:

  • 描述:

    FDC40-12D12 - Isolated and Regulated 40 WATT Modular DC/DC Converters - Astrodyne Corporation

  • 详情介绍
  • 数据手册
  • 价格&库存
FDC40-12D12 数据手册
I s o l a t e d a n d R e gulated 40 WATT Modular DC/DC Converters Wide 2 : 1 Input Range High Efficiency Regulated Outputs 1600V Isolation Full EMI Shielding PI Input Filter FDC40 series Unit measures 2.76”W x 3.94”L x 0.75”H Model Number SINGLE OUTPUT FDC40-12S33 FDC40-24S33 FDC40-48S33 FDC40-12S05 FDC40-24S05 FDC40-48S05 FDC40-12S12 FDC40-24S12 FDC40-48S12 FDC40-12S15 FDC40-24S15 FDC40-48S15 Output Voltage Output Amps Input Range UL E193009; TUV R2054535; CB JPTUV-001393 3.3 VDC 5 VDC 12 VDC 15 VDC 10 10 10 8 8 8 3.4 3.4 3.4 2.7 2.7 2.7 9-18 VDC 18-36 VDC 36-72 VDC 9-18 VDC 18-36 VDC 36-72 VDC 9-18 VDC 18-36 VDC 36-72 VDC 9-18 VDC 18-36 VDC 36-72 VDC Order On-Line! WWW.ASTRODYNE.COM astrodyne.com 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 I s o l a t e d a n d R e gulated 40 WATT Modular DC/DC Converters Wide 2 : 1 Input Range High Efficiency Regulated Outputs 1600V Isolation Full EMI Shielding PI Input Filter FDC40 series Unit measures 2.76”W x 3.94”L x 0.75”H Model Number DUAL OUTPUT FDC40-12D3305 FDC40-24D3305 FDC40-48D3305 FDC40-12D05 FDC40-24D05 FDC40-48D05 FDC40-12D12 FDC40-24D12 FDC40-48D12 FDC40-12D15 FDC40-24D15 FDC40-48D15 TRIPLE OUTPUT FDC40-12T0512 FDC40-24T0512 FDC40-48T0512 FDC40-12T0515 FDC40-24T0515 FDC40-48T0515 Output Voltage Output Amps Input Range UL E193009; TUV R2054535; CB JPTUV-001393 3.3 / 5 VDC +/-5 VDC +/-12 VDC +/-15 VDC 4-Apr 4-Apr 4-Apr -7 -7 -7 +/-1.8 +/-1.8 +/-1.8 +/-1.4 +/-1.4 +/-1.4 4, +/-0.85 4, +/-0.85 4, +/-0.85 4, +/-0.68 4, +/-0.68 4, +/-0.68 9-18 VDC 18-36 VDC 36-72 VDC 9-18 VDC 18-36 VDC 36-72 VDC 9-18 VDC 18-36 VDC 36-72 VDC 9-18 VDC 18-36 VDC 36-72 VDC 9-18 VDC 18-36 VDC 36-72 VDC 9-18 VDC 18-36 VDC 36-72 VDC 5, +/-12 VDC 5, +/-15 VDC Order On-Line! WWW.ASTRODYNE.COM astrodyne.com 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 I s o l a t e d a n d R e gulated 40 WATT Modular DC/DC Converters INPUT SPECIFICATIONS Input Voltage Ranges: 12 VDC Nominal 24 VDC Nominal 48 VDC Nominal Pi Type 9-18 VDC 18-36 VDC 36-72 VDC FDC40 (Ref to - Input pin) Logic “1”/Open=ON Logic “0”/GND=OFF 1600VDC 10000 M Ohms 82%, typ 185Khz, typ series GENERAL SPECIFICATIONS On/Off Control Input Filter OUTPUT SPECIFICATIONS Voltage and Current Load Regulation See Selection Chart singles: +/-0.5% duals: +/-1% triples: 5 V:+/-2%, Aux: +/-5% Line Regulation singles: +/-0.5% duals: +/-1% triples: 5V:+/-2%, Aux:+/-5% Temperature Coefficient +/-0.02%/DegC Ripple/Noise 1% Pk-Pk of Vout, typ Voltage Stability (singles/duals) +/- 2% (triples) 5 V:+/-2%, Aux: +/-5% Short Circuit Protection Continuous, self-recovering Overvoltage Protection Threshold: 3.3V Output 3.9Volts 5V Output 6.2Volts 12V Output 15Volts 15V Output 18Volts Input-Out Isolation Isolation Resistance Efficiency Switching Frequency ENVIRONMENTAL SPECIFICATIONS Oper. Temperature (Case) Storage Temperature Maximum Case Temp MTBF -25 to +85 DegC(see derate) -55 to +125 DegC * 100 DegC * 1.61 MHrs MIL-HDBK-217F TA=25C FL PHYSICAL SPECIFICATIONS Case Material Construction Weight Nickel-Coated Copper Non-Conductive Base Fully Encapsulated 4.5 oz, (126g) EFFICIENCY CURVES FDC40-48S05 Efficiency VS Input Voltage EFFICIENCY (%) 90 89 88 87 86 85 84 83 82 81 80 FDC40-48S05 Efficiency VS Output load EFFICIENCY (%) 90 89 88 86 84 82 80 70 60 50 45 0.5 36 40 45 50 55 60 65 70 75 1 2 3 4 5 6 7 8 INPUT VOLTAGE (V) OUTPUT LOAD (A) All specifications are typical at nominal input, full load, and 25DegC unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. WWW.ASTRODYNE.COM 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 I s o l a t e d a n d R e gulated 40 WATT Modular DC/DC Converters MECHANICAL DIMENSIONS 0.40 (10.2) 0.40 (10.2) 0.32 (7.6) 2.60 (66.0) 0.60 (15.2) 0.70 (17.8) 0.40 (10.2) FDC40 series EXTERNAL OUTPUT TRIMMING Output can be externally trimmed by using the method shown below. ( ) for dual output trim [ ] for triple output trim { } XXD3305 only trim 3.3V/5V TRIM UP EXTERNAL OUTPUT TRIMMING DIA. 0.04 (1.0) 1 2 3 4 TRIM DOWN 7 (7) [9] {6} 6 (8) [10] {8} RU 6 (8) [10] {8} 5 (5) [8] {5} RD 3.00 (76.2) 2.50 (63.5) Bottom View Pin # 1 2 3 4 5 6 7 8 9 10 Single Ctrl + Vin - Vin Sync + OutS Trim - OutS + Vout - Vout No Pin Dual Ctrl + Vin - Vin Sync + Vout or 3.3 out Com - Vout or 5 out Trim No Pin No Pin Triple Ctrl + Vin - Vin Sync + Vout Com - Vout +5 Out -5 Out Trim 5 6 7 0.50 (12.7) 8 0.40 (10.2) 9 0.40 (10.2) 10 0.40 (10.2) 0.32 (8.0) 0.32 (7.6) 0.32 (7.6) 1. All dimensions in Inches (mm) 2. Pin pitch tolerance 0.014 (0.35) OUTPUT DERATING CURVE FDC40-48S05 Derating Curve OUTPUT POWER (%) 100 75 50 25 0 -40 -25 -10 0 50 60 70 80 90 100 Nature convection AMBIENT TEMPERATURE (ºC) WWW.ASTRODYNE.COM 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 I s o l a t e d a n d R e gulated 40 WATT Modular DC/DC Converters APPLICATION OF SYNCHRONIZATION 1. The unit is capable of external synchronization from an independent time base with a switching rate between 200kHz and 215kHz 2. The amplitude of the synchronizing pulse train is TTL compatible 3. The duty cycle of the CLK should be 20% high and 80% low 4. Synchronization is referenced to negative input (-Vin) Converter 1 + Vin 2 4 - Vin 3 FDC40 series + Sync Converter 2 2 4 3 CLK CLK Signal 80% 2N7000 + Sync ON/OFF Control application Converter + Vin 2 1 - Vin ON/OFF Control - + CTRL 3 - 20% WWW.ASTRODYNE.COM 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181
FDC40-12D12
1. 物料型号: - 单路输出型号:FDC40-12S33、FDC40-24S33、FDC40-48S33、FDC40-12S05、FDC40-24S05、FDC40-48S05、FDC40-12S12、FDC40-24S12、FDC40-48S12、FDC40-12S15、FDC40-24S15、FDC40-48S15。 - 双路输出型号:FDC40-12D3305、FDC40-24D3305、FDC40-48D3305、FDC40-12D05、FDC40-24D05、FDC40-48D05、FDC40-12D12、FDC40-24D12、FDC40-48D12、FDC40-12D15、FDC40-24D15、FDC40-48D15。 - 三路输出型号:FDC40-12T0512、FDC40-24T0512、FDC40-48T0512、FDC40-12T0515、FDC40-24T0515、FDC40-48T0515。

2. 器件简介: - ASTRODYNE FDC40系列是隔离和稳压的40瓦模块DC/DC转换器,具有宽输入范围、高效率、稳压输出、1600V隔离、全EMI屏蔽和PI输入滤波器。

3. 引脚分配: - 控制引脚(Ctrl):用于开关控制。 - 输入正(+Vin)和输入负(-Vin):连接输入电压。 - 同步(Sync):用于外部同步。 - 输出正(+Vout)和输出负(-Vout):连接稳压后的输出电压。 - 调整(Trim):用于外部调整输出电压。

4. 参数特性: - 输入电压范围:12VDC、24VDC、48VDC。 - 输出电压和电流:不同型号有不同的输出电压和电流规格。 - 隔离电压:1600VDC。 - 效率:典型值82%。 - 开关频率:典型值185kHz。

5. 功能详解: - 该系列转换器支持外部同步,同步脉冲幅度需与TTL兼容,占空比应为20%高电平和80%低电平。 - 支持开/关控制,逻辑"1"或开为ON,逻辑"0"或GND为OFF。

6. 应用信息: - 适用于非关键性应用,不适用于生命支持系统、危险环境设备、核控制设备或其他关键任务应用。

7. 封装信息: - 封装材料为镍涂层铜,非导电基底,全封装结构,重量为4.5盎司(约126克)。
FDC40-12D12 价格&库存

很抱歉,暂时无法提供与“FDC40-12D12”相匹配的价格&库存,您可以联系我们找货

免费人工找货