0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AT25DF641A-SH-T

AT25DF641A-SH-T

  • 厂商:

    ATMEL(爱特梅尔)

  • 封装:

  • 描述:

    AT25DF641A-SH-T - 64-Mbit 2.7V Minimum Serial Peripheral Interface Serial Flash Memory - ATMEL Corpo...

  • 数据手册
  • 价格&库存
AT25DF641A-SH-T 数据手册
Features • Single 2.7V - 3.6V Supply • Serial Peripheral Interface (SPI) Compatible – Supports SPI Modes 0 and 3 – Supports Atmel RapidS Operation – Supports Dual-Input Program and Dual-Output Read Very High Operating Frequencies – 100MHz for RapidS – 85MHz for SPI – Clock-to-Output (tV) of 5ns Maximum Flexible, Optimized Erase Architecture for Code + Data Storage Applications – Uniform 4-Kbyte Block Erase – Uniform 32-Kbyte Block Erase – Uniform 64-Kbyte Block Erase – Full Chip Erase Individual Sector Protection with Global Protect/Unprotect Feature – 128 Sectors of 64-Kbytes Each Hardware Controlled Locking of Protected Sectors via WP Pin Sector Lockdown – Make Any Combination of 64-Kbyte Sectors Permanently Read-Only 128-Byte Programmable OTP Security Register Flexible Programming – Byte/Page Program (1- to 256-Bytes) Fast Program and Erase Times – 1.0ms Typical Page Program (256-Bytes) Time – 50ms Typical 4-Kbyte Block Erase Time – 250ms Typical 32-Kbyte Block Erase Time – 400ms Typical 64-Kbyte Block Erase Time Program and Erase Suspend/Resume Automatic Checking and Reporting of Erase/Program Failures Software Controlled Reset JEDEC Standard Manufacturer and Device ID Read Methodology Low Power Dissipation – 5mA Active Read Current (Typical at 20MHz) – 5µA Deep Power-Down Current (Typical) Endurance: 100,000 Program/Erase Cycles Data Retention: 20 Years Complies with Full Industrial Temperature Range Industry Standard Green (Pb/Halide-free/RoHS Compliant) Package Options – 8-lead SOIC (208-mil wide) – 8-contact Ultra Thin DFN (5mm x 6mm x 0.6mm) • • • • • • • • 64-Mbit 2.7V Minimum Serial Peripheral Interface Serial Flash Memory Atmel AT25DF641A Preliminary • • • • • • • • • 8693A–DFLASH–8/10 1. Description The Atmel® AT25DF641 is a serial interface Flash memory device designed for use in a wide variety of high-volume consumer based applications in which program code is shadowed from Flash memory into embedded or external RAM for execution. The flexible erase architecture of the AT25DF641A, with its erase granularity as small as 4-Kbytes, makes it ideal for data storage as well, eliminating the need for additional data storage EEPROM devices. The physical sectoring and the erase block sizes of the AT25DF641A have been optimized to meet the needs of today's code and data storage applications. By optimizing the size of the physical sectors and erase blocks, the memory space can be used much more efficiently. Because certain code modules and data storage segments must reside by themselves in their own protected sectors, the wasted and unused memory space that occurs with large sectored and large block erase Flash memory devices can be greatly reduced. This increased memory space efficiency allows additional code routines and data storage segments to be added while still maintaining the same overall device density. The AT25DF641A also offers a sophisticated method for protecting individual sectors against erroneous or malicious program and erase operations. By providing the ability to individually protect and unprotect sectors, a system can unprotect a specific sector to modify its contents while keeping the remaining sectors of the memory array securely protected. This is useful in applications where program code is patched or updated on a subroutine or module basis, or in applications where data storage segments need to be modified without running the risk of errant modifications to the program code segments. In addition to individual sector protection capabilities, the AT25DF641A incorporates Global Protect and Global Unprotect features that allow the entire memory array to be either protected or unprotected all at once. This reduces overhead during the manufacturing process since sectors do not have to be unprotected one-by-one prior to initial programming. To take code and data protection to the next level, the AT25DF641A incorporates a sector lockdown mechanism that allows any combination of individual 64-Kbyte sectors to be locked down and become permanently read-only. This addresses the need of certain secure applications that require portions of the Flash memory array to be permanently protected against malicious attempts at altering program code, data modules, security information, or encryption/decryption algorithms, keys, and routines. The device also contains a specialized OTP (One-Time Programmable) Security Register that can be used for purposes such as unique device serialization, system-level Electronic Serial Number (ESN) storage, locked key storage, etc. Specifically designed for use in 3V systems, the AT25DF641A supports read, program, and erase operations with a supply voltage range of 2.7V to 3.6V. No separate voltage is required for programming and erasing. 2 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] 2. Pin Descriptions and Pinouts Table 2-1. Symbol Pin Descriptions Name and Function CHIP SELECT: Asserting the CS pin selects the device. When the CS pin is deasserted, the device will be deselected and normally be placed in standby mode (not Deep PowerDown mode), and the SO pin will be in a high-impedance state. When the device is deselected, data will not be accepted on the SI pin. A high-to-low transition on the CS pin is required to start an operation, and a low-to-high transition is required to end an operation. When ending an internally self-timed operation such as a program or erase cycle, the device will not enter the standby mode until the completion of the operation. SERIAL CLOCK: This pin is used to provide a clock to the device and is used to control the flow of data to and from the device. Command, address, and input data present on the SI pin is always latched in on the rising edge of SCK, while output data on the SO pin is always clocked out on the falling edge of SCK. SERIAL INPUT (SERIAL INPUT/OUTPUT): The SI pin is used to shift data into the device. The SI pin is used for all data input including command and address sequences. Data on the SI pin is always latched in on the rising edge of SCK. With the Dual-Output Read Array command, the SI pin becomes an output pin (SIO) to allow two bits of data (on the SO and SIO pins) to be clocked out on every falling edge of SCK. To maintain consistency with SPI nomenclature, the SIO pin will be referenced as SI throughout the document with exception to sections dealing with the Dual-Output Read Array command in which it will be referenced as SIO. Data present on the SI pin will be ignored whenever the device is deselected (CS is deasserted). SERIAL OUTPUT (SERIAL OUTPUT/INPUT): The SO pin is used to shift data out from the device. Data on the SO pin is always clocked out on the falling edge of SCK. With the Dual-Input Byte/Page Program command, the SO pin becomes an input pin (SOI) to allow two bits of data (on the SOI and SI pins) to be clocked in on every rising edge of SCK. To maintain consistency with SPI nomenclature, the SOI pin will be referenced as SO throughout the document with exception to sections dealing with the Dual-Input Byte/Page Program command in which it will be referenced as SOI. The SO pin will be in a high-impedance state whenever the device is deselected (CS is deasserted). WRITE PROTECT: The WP pin controls the hardware locking feature of the device. Please refer to “Protection Commands and Features” on page 20 for more details on protection features and the WP pin. The WP pin is internally pulled-high and may be left floating if hardware controlled protection will not be used. However, it is recommended that the WP pin also be externally connected to VCC whenever possible. Asserted State Type CS Low Input SCK - Input SI (SIO) - Input/Output SO (SOI) - Output/Input WP Low Input 3 8693A–DFLASH–8/10 Table 2-1. Symbol Pin Descriptions (Continued) Name and Function HOLD: The HOLD pin is used to temporarily pause serial communication without deselecting or resetting the device. While the HOLD pin is asserted, transitions on the SCK pin and data on the SI pin will be ignored, and the SO pin will be in a high-impedance state. The CS pin must be asserted, and the SCK pin must be in the low state in order for a Hold condition to start. A Hold condition pauses serial communication only and does not have an effect on internally self-timed operations such as a program or erase cycle. Please refer to “Hold” on page 44 for additional details on the Hold operation. The HOLD pin is internally pulled-high and may be left floating if the Hold function will not be used. However, it is recommended that the HOLD pin also be externally connected to VCC whenever possible. DEVICE POWER SUPPLY: The VCC pin is used to supply the source voltage to the device. Operations at invalid VCC voltages may produce spurious results and should not be attempted. GROUND: The ground reference for the power supply. GND should be connected to the system ground. Asserted State Type HOLD Low Input VCC - Power GND - Power Figure 2-1. 8-SOIC (Top View) CS SO WP GND 1 2 3 4 8 7 6 5 VCC HOLD SCK SI Figure 2-2. 8-UDFN (Top View) CS SO (SOI) WP GND 1 2 3 4 8 7 6 5 VCC HOLD SCK SI (SIO) 4 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] 3. Block Diagram Figure 3-1. Block Diagram CS CONTROL AND PROTECTION LOGIC I/O BUFFERS AND LATCHES SCK SI (SIO) SO (SOI) INTERFACE CONTROL AND LOGIC SRAM DATA BUFFER Y-DECODER Y-GATING ADDRESS LATCH WP HOLD X-DECODER FLASH MEMORY ARRAY 4. Memory Array To provide the greatest flexibility, the memory array of the Atmel® AT25DF641A can be erased in four levels of granularity including a full chip erase. In addition, the array has been divided into physical sectors of uniform size, of which each sector can be individually protected from program and erase operations. The size of the physical sectors is optimized for both code and data storage applications, allowing both code and data segments to reside in their own isolated regions. The Memory Architecture Diagram illustrates the breakdown of each erase level as well as the breakdown of each physical sector. 5 8693A–DFLASH–8/10 Figure 4-1. Memory Architecture Diagram Block Erase Detail Page Program Detail Block Address Range 7F F F F F h – 7F F 000h 7F E F F F h – 7F E 000h 7F DF F F h – 7F D000h 7F CF F F h – 7F C000h 7F BF F F h – 7F B000h 7F AF F F h – 7F A000h 7F 9F F F h – 7F 9000h 7F 8F F F h – 7F 8000h 7F 7F F F h – 7F 7000h 7F 6F F F h – 7F 6000h 7F 5F F F h – 7F 5000h 7F 4F F F h – 7F 4000h 7F 3F F F h – 7F 3000h 7F 2F F F h – 7F 2000h 7F 1F F F h – 7F 1000h 7F 0F F F h – 7F 0000h 7E F F F F h – 7E F 000h 7E E F F F h– 7E E 000h 7E DF F F h – 7E D000h 7E CF F F h – 7E C000h 7E BF F F h – 7E B000h 7E AF F F h – 7E A000h 7E 9F F F h – 7E 9000h 7E 8F F F h – 7E 8000h 7E 7F F F h – 7E 7000h 7E 6F F F h – 7E 6000h 7E 5F F F h – 7E 5000h 7E 4F F F h – 7E 4000h 7E 3F F F h – 7E 3000h 7E 2F F F h – 7E 2000h 7E 1F F F h – 7E 1000h 7E 0F F F h – 7E 0000h 1-256 Byte Page Program (02h Command) 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes ••• Internal Sectoring for Protection, Lockdown, and Suspend Functions 64KB Block Erase (D8h Command) 32KB Block Erase (52h Command) 4KB Block Erase (20h Command) 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB ••• Page Address Range 7F F F F F h – 7F F F 00h 7F F E F F h – 7F F E 00h 7F F DF F h – 7F F D00h 7F F CF F h – 7F F C00h 7F F BF F h – 7F F B00h 7F F AF F h – 7F F A00h 7F F 9F F h – 7F F 900h 7F F 8F F h – 7F F 800h 7F F 7F F h – 7F F 700h 7F F 6F F h – 7F F 600h 7F F 5F F h – 7F F 500h 7F F 4F F h – 7F F 400h 7F F 3F F h – 7F F 300h 7F F 2F F h – 7F F 200h 7F F 1F F h – 7F F 100h 7F F 0F F h – 7F F 000h 7F E F F F h – 7F E F 00h 7F E E F F h– 7F E E 00h 7F E DF F h – 7F E D00h 7F E CF F h – 7F E C00h 7F E BF F h – 7F E B00h 7F E AF F h – 7F E A00h 7F E 9F F h – 7F E 900h 7F E 8F F h – 7F E 800h 32KB 64KB (Sector 127) 64KB 32KB 32KB 64KB (Sector 126) 64KB 32KB 32KB 64KB (Sector 0) 64KB 32KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 4KB 00F F F F h – 00F 000h 00E F F F h – 00E 000h 00DF F F h – 00D000h 00CF F F h – 00C000h 00BF F F h – 00B000h 00AF F F h – 00A000h 009F F F h – 009000h 008F F F h – 008000h 007F F F h – 007000h 006F F F h – 006000h 005F F F h – 005000h 004F F F h – 004000h 003F F F h – 003000h 002F F F h – 002000h 001F F F h – 001000h 000F F F h – 000000h 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 256 Bytes 0017F F h – 001700h 0016F F h – 001600h 0015F F h – 001500h 0014F F h – 001400h 0013F F h – 001300h 0012F F h – 001200h 0011F F h – 001100h 0010F F h – 001000h 000F F F h – 000F 00h 000E F F h – 000E 00h 000DF F h – 000D00h 000CF F h – 000C00h 000BF F h – 000B00h 000AF F h – 000A00h 0009F F h – 000900h 0008F F h – 000800h 0007F F h – 000700h 0006F F h – 000600h 0005F F h – 000500h 0004F F h – 000400h 0003F F h – 000300h 0002F F h – 000200h 0001F F h – 000100h 0000F F h – 000000h ••• ••• 6 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 ••• Atmel AT25DF641A [Preliminary] 5. Device Operation The Atmel® AT25DF641A is controlled by a set of instructions that are sent from a host controller, commonly referred to as the SPI Master. The SPI Master communicates with the AT25DF641A via the SPI bus which is comprised of four signal lines: Chip Select (CS), Serial Clock (SCK), Serial Input (SI), and Serial Output (SO). The AT25DF641A features a dual-input program mode in which the SO pin becomes an input. Similarly, the device also features a dual-output read mode in which the SI pin becomes an output. In the Dual-Input Byte/Page Program command description, the SO pin will be referred to as the SOI (Serial Output/Input) pin, and in the Dual-Output Read Array command, the SI pin will be referenced as the SIO (Serial Input/Output) pin. The SPI protocol defines a total of four modes of operation (mode 0, 1, 2, or 3) with each mode differing in respect to the SCK polarity and phase and how the polarity and phase control the flow of data on the SPI bus. The AT25DF641A supports the two most common modes, SPI Modes 0 and 3. The only difference between SPI Modes 0 and 3 is the polarity of the SCK signal when in the inactive state (when the SPI Master is in standby mode and not transferring any data). With SPI Modes 0 and 3, data is always latched in on the rising edge of SCK and always output on the falling edge of SCK. Figure 5-1. CS SPI Mode 0 and 3 SCK SI MSB LSB SO MSB LSB 6. Commands and Addressing A valid instruction or operation must always be started by first asserting the CS pin. After the CS pin has been asserted, the host controller must then clock out a valid 8-bit opcode on the SPI bus. Following the opcode, instruction dependent information such as address and data bytes would then be clocked out by the host controller. All opcode, address, and data bytes are transferred with the most-significant bit (MSB) first. An operation is ended by deasserting the CS pin. Opcodes not supported by the AT25DF641A will be ignored by the device and no operation will be started. The device will continue to ignore any data presented on the SI pin until the start of the next operation (CS pin being deasserted and then reasserted). In addition, if the CS pin is deasserted before complete opcode and address information is sent to the device, then no operation will be performed and the device will simply return to the idle state and wait for the next operation. Addressing of the device requires a total of three bytes of information to be sent, representing address bits A23-A0. Since the upper address limit of the AT25DF641A memory array is 7FFFFFh, address bit A23 is always ignored by the device. 7 8693A–DFLASH–8/10 Table 6-1. Command Command Listing Opcode Clock Frequency Address Bytes Dummy Bytes Data Bytes Read Commands 1Bh Read Array 0Bh 03h Dual-Output Read Array Program and Erase Commands Block Erase (4-KBytes) Block Erase (32-KBytes) Block Erase (64-KBytes) Chip Erase C7h Byte/Page Program (1- to 256-Bytes) Dual-Input Byte/Page Program (1- to 256-Bytes) Program/Erase Suspend Program/Erase Resume Protection Commands Write Enable Write Disable Protect Sector Unprotect Sector Global Protect/Unprotect Read Sector Protection Registers Security Commands Sector Lockdown Freeze Sector Lockdown State Read Sector Lockdown Registers Program OTP Security Register Read OTP Security Register Status Register Commands Read Status Register Write Status Register Byte 1 Write Status Register Byte 2 Miscellaneous Commands Reset Read Manufacturer and Device ID Deep Power-Down Resume from Deep Power-Down F0h 9Fh B9h ABh 1111 0000 1001 1111 1011 1001 1010 1011 Up to 100MHz Up to 85 MHz Up to 100 MHz Up to 100 MHz 0 0 0 0 0 0 0 0 1 1 to 4 0 0 05h 01h 31h 0000 0101 0000 0001 0011 0001 Up to 100MHz Up to 100MHz Up to 100MHz 0 0 0 0 0 0 1+ 1 1 33h 34h 35h 9Bh 77h 0011 0011 0011 0100 0011 0101 1001 1011 0111 0111 Up to 100MHz Up to 100MHz Up to 100MHz Up to 100MHz Up to 100MHz 3 3 3 3 3 0 0 0 0 2 1 1 1+ 1+ 1+ 3Ch 06h 04h 36h 39h 0000 0110 0000 0100 0011 0110 0011 1001 Up to 100MHz Up to 100MHz Up to 100MHz Up to 100MHz 0 0 3 3 0 0 0 0 0 0 0 0 02h A2h B0h D0h 1100 0111 0000 0010 1010 0010 1011 0000 1101 0000 Up to 100MHz Up to 100MHz Up to 100MHz Up to 100MHz Up to 100MHz 0 3 3 0 0 0 0 0 0 0 0 1+ 1+ 0 0 20h 52h D8h 60h 0010 0000 0101 0010 1101 1000 0110 0000 Up to 100MHz Up to 100MHz Up to 100MHz Up to 100MHz 3 3 3 0 0 0 0 0 0 0 0 0 3Bh 0001 1011 0000 1011 0000 0011 0011 1011 Up to 100MHz Up to 85MHz Up to 50MHz Up to 85MHz 3 3 3 3 2 1 0 1 1+ 1+ 1+ 1+ Use Write Status Register Byte 1 Command 0011 1100 Up to 100MHz 3 0 1+ 8 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] 7. Read Commands 7.1 Read Array The Read Array command can be used to sequentially read a continuous stream of data from the device by simply providing the clock signal once the initial starting address has been specified. The device incorporates an internal address counter that automatically increments on every clock cycle. Three opcodes (1Bh, 0Bh, and 03h) can be used for the Read Array command. The use of each opcode depends on the maximum clock frequency that will be used to read data from the device. The 0Bh opcode can be used at any clock frequency up to the maximum specified by fCLK, and the 03h opcode can be used for lower frequency read operations up to the maximum specified by fRDLF. The 1Bh opcode allows the highest read performance possible and can be used at any clock frequency up to the maximum specified by fMAX; however, use of the 1Bh opcode at clock frequencies above fCLK should be reserved to systems employing the Atmel® RapidS protocol. To perform the Read Array operation, the CS pin must first be asserted and the appropriate opcode (1Bh, 0Bh, or 03h) must be clocked into the device. After the opcode has been clocked in, the three address bytes must be clocked in to specify the starting address location of the first byte to read within the memory array. Following the three address bytes, additional dummy bytes may need to be clocked into the device depending on which opcode is used for the Read Array operation. If the 1Bh opcode is used, then two dummy bytes must be clocked into the device after the three address bytes. If the 0Bh opcode is used, then a single dummy byte must be clocked in after the address bytes. After the three address bytes (and the dummy bytes or byte if using opcodes 1Bh or 0Bh) have been clocked in, additional clock cycles will result in data being output on the SO pin. The data is always output with the MSB of a byte first. When the last byte (7FFFFFh) of the memory array has been read, the device will continue reading back at the beginning of the array (000000h). No delays will be incurred when wrapping around from the end of the array to the beginning of the array. Deasserting the CS pin will terminate the read operation and put the SO pin into a high-impedance state. The CS pin can be deasserted at any time and does not require that a full byte of data be read. Figure 7-1. CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 Read Array - 1Bh Opcode SCK OPCODE ADDRESS BITS A23-A0 0 1 1 A MSB DON'T CARE A A X MSB DON'T CARE X X X MSB SI 0 MSB 0 0 1 1 A A A A A A X X X X X X X X X X X X DATA BYTE 1 SO HIGH-IMPEDANCE D MSB D D D D D D D D MSB D 9 8693A–DFLASH–8/10 Figure 7-2. CS Read Array - 0Bh Opcode SCK 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 OPCODE ADDRESS BITS A23-A0 0 1 1 A MSB DON'T CARE A A X MSB SI 0 MSB 0 0 0 1 A A A A A A X X X X X X X DATA BYTE 1 SO HIGH-IMPEDANCE D MSB D D D D D D D D MSB D Figure 7-3. Read Array - 03h Opcode CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 37 38 39 40 SCK OPCODE ADDRESS BITS A23-A0 0 1 1 A MSB SI 0 MSB 0 0 0 0 A A A A A A A A DATA BYTE 1 SO HIGH-IMPEDANCE D MSB D D D D D D D D MSB D 7.2 Dual-Output Read Array The Dual-Output Read Array command is similar to the standard Read Array command and can be used to sequentially read a continuous stream of data from the device by simply providing the clock signal once the initial starting address has been specified. Unlike the standard Read Array command, however, the Dual-Output Read Array command allows two bits of data to be clocked out of the device on every clock cycle rather than just one. The Dual-Output Read Array command can be used at any clock frequency up to the maximum specified by fRDDO. To perform the Dual-Output Read Array operation, the CS pin must first be asserted and the opcode of 3Bh must be clocked into the device. After the opcode has been clocked in, the three address bytes must be clocked in to specify the starting address location of the first byte to read within the memory array. Following the three address bytes, a single dummy byte must also be clocked into the device. After the three address bytes and the dummy byte have been clocked in, additional clock cycles will result in data being output on both the SO and SIO pins. The data is always output with the MSB of a byte first, and the MSB is always output on the SO pin. During the first clock cycle, bit seven of the first data byte will be output on the SO pin while bit six of the same data byte will be output on the SIO pin. During the next clock cycle, bits five and four of the first data byte will be output on the SO and SIO pins, respectively. The sequence continues with each byte of data being output after every four clock cycles. When the last byte (7FFFFFh) of the memory array has been read, the device will continue reading back at the beginning of the array (000000h). No delays will be incurred when wrapping around from the end of the array to the beginning of the array. 10 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] Deasserting the CS pin will terminate the read operation and put the SO and SIO pins into a high-impedance state. The CS pin can be deasserted at any time and does not require that a full byte of data be read. Figure 7-4. CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Dual-Output Read Array SCK OPCODE ADDRESS BITS A23-A0 0 1 1 A MSB DON'T CARE A A A X MSB OUTPUT DATA BYTE 1 X X X D6 D4 D2 D0 OUTPUT DATA BYTE 2 D6 D4 D2 D0 D6 D4 SIO 0 MSB 0 1 1 1 A A A A A X X X X SO HIGH-IMPEDANCE D7 MSB D5 D3 D1 D7 MSB D5 D3 D1 D7 MSB D5 8. Program and Erase Commands 8.1 Byte/Page Program The Byte/Page Program command allows anywhere from a single byte of data to 256-bytes of data to be programmed into previously erased memory locations. An erased memory location is one that has all eight bits set to the logical “1” state (a byte value of FFh). Before a Byte/Page Program command can be started, the Write Enable command must have been previously issued to the device (see “Write Enable” on page 20) to set the Write Enable Latch (WEL) bit of the Status Register to a logical “1” state. To perform a Byte/Page Program command, an opcode of 02h must be clocked into the device followed by the three address bytes denoting the first byte location of the memory array to begin programming at. After the address bytes have been clocked in, data can then be clocked into the device and will be stored in an internal buffer. If the starting memory address denoted by A23-A0 does not fall on an even 256-byte page boundary (A7-A0 are not all 0), then special circumstances regarding which memory locations to be programmed will apply. In this situation, any data that is sent to the device that goes beyond the end of the page will wrap around back to the beginning of the same page. For example, if the starting address denoted by A23-A0 is 0000FEh, and three bytes of data are sent to the device, then the first two bytes of data will be programmed at addresses 0000FEh and 0000FFh while the last byte of data will be programmed at address 000000h. The remaining bytes in the page (addresses 000001h through 0000FDh) will not be programmed and will remain in the erased state (FFh). In addition, if more than 256-bytes of data are sent to the device, then only the last 256 bytes sent will be latched into the internal buffer. When the CS pin is deasserted, the device will take the data stored in the internal buffer and program it into the appropriate memory array locations based on the starting address specified by A23-A0 and the number of data bytes sent to the device. If less than 256-bytes of data were sent to the device, then the remaining bytes within the page will not be programmed and will remain in the erased state (FFh). The programming of the data bytes is internally self-timed and should take place in a time of tPP or tBP if only programming a single byte. 11 8693A–DFLASH–8/10 The three address bytes and at least one complete byte of data must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on even byte boundaries (multiples of eight bits); otherwise, the device will abort the operation and no data will be programmed into the memory array. In addition, if the address specified by A23-A0 points to a memory location within a sector that is in the protected state (see “Protect Sector” on page 21) or locked down (see “Sector Lockdown” on page 28), then the Byte/Page Program command will not be executed, and the device will return to the idle state once the CS pin has been deasserted. The WEL bit in the Status Register will be reset back to the logical “0” state if the program cycle aborts due to an incomplete address being sent, an incomplete byte of data being sent, the CS pin being deasserted on uneven byte boundaries, or because the memory location to be programmed is protected or locked down. While the device is programming, the Status Register can be read and will indicate that the device is busy. For faster throughput, it is recommended that the Status Register be polled rather than waiting the tBP or tPP time to determine if the data bytes have finished programming. At some point before the program cycle completes, the WEL bit in the Status Register will be reset back to the logical “0” state. The device also incorporates an intelligent programming algorithm that can detect when a byte location fails to program properly. If a programming error arises, it will be indicated by the EPE bit in the Status Register. Figure 8-1. Byte Program CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 37 38 39 SCK OPCODE ADDRESS BITS A23-A0 0 1 0 A MSB DATA IN A A D MSB SI 0 MSB 0 0 0 0 A A A A A A D D D D D D D SO HIGH-IMPEDANCE Figure 8-2. Page Program CS 0 1 2 3 4 5 6 7 8 9 29 30 31 32 33 34 35 36 37 38 39 SCK OPCODE ADDRESS BITS A23-A0 0 1 0 A MSB DATA IN BYTE 1 D MSB DATA IN BYTE n D D MSB SI 0 MSB 0 0 0 0 A A A A A D D D D D D D D D D D D D SO HIGH-IMPEDANCE 12 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] 8.2 Dual-Input Byte/Page Program The Dual-Input Byte/Page Program command is similar to the standard Byte/Page Program command and can be used to program anywhere from a single byte of data up to 256-bytes of data into previously erased memory locations. Unlike the standard Byte/Page Program command, however, the Dual-Input Byte/Page Program command allows two bits of data to be clocked into the device on every clock cycle rather than just one. Before the Dual-Input Byte/Page Program command can be started, the Write Enable command must have been previously issued to the device (see “Write Enable” on page 20) to set the Write Enable Latch (WEL) bit of the Status Register to a logical “1” state. To perform a Dual-Input Byte/Page Program command, an opcode of A2h must be clocked into the device followed by the three address bytes denoting the first byte location of the memory array to begin programming at. After the address bytes have been clocked in, data can then be clocked into the device two bits at a time on both the SOI and SI pins. The data is always input with the MSB of a byte first, and the MSB is always input on the SOI pin. During the first clock cycle, bit seven of the first data byte would be input on the SOI pin while bit 6 of the same data byte would be input on the SI pin. During the next clock cycle, bits five and four of the first data byte would be input on the SOI and SI pins, respectively. The sequence would continue with each byte of data being input after every four clock cycles. Like the standard Byte/Page Program command, all data clocked into the device is stored in an internal buffer. If the starting memory address denoted by A23-A0 does not fall on an even 256-byte page boundary (A7-A0 are not all 0), then special circumstances regarding which memory locations to be programmed will apply. In this situation, any data that is sent to the device that goes beyond the end of the page will wrap around back to the beginning of the same page. For example, if the starting address denoted by A23-A0 is 0000FEh, and three bytes of data are sent to the device, then the first two bytes of data will be programmed at addresses 0000FEh and 0000FFh while the last byte of data will be programmed at address 000000h. The remaining bytes in the page (addresses 000001h through 0000FDh) will not be programmed and will remain in the erased state (FFh). In addition, if more than 256-bytes of data are sent to the device, then only the last 256-bytes sent will be latched into the internal buffer. When the CS pin is deasserted, the device will take the data stored in the internal buffer and program it into the appropriate memory array locations based on the starting address specified by A23-A0 and the number of data bytes sent to the device. If less than 256-bytes of data were sent to the device, then the remaining bytes within the page will not be programmed and will remain in the erased state (FFh). The programming of the data bytes is internally self-timed and should take place in a time of tPP or tBP if only programming a single byte. The three address bytes and at least one complete byte of data must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on even byte boundaries (multiples of eight bits); otherwise, the device will abort the operation and no data will be programmed into the memory array. In addition, if the address specified by A23-A0 points to a memory location within a sector that is in the protected state (see “Protect Sector” on page 21) or locked down (see “Sector Lockdown” on page 28), then the Byte/Page Program command will not be executed, and the device will return to the idle state once the CS pin has been deasserted. The WEL bit in the Status Register will be reset back to the logical “0” state if the program cycle aborts due to an incomplete address being sent, an incomplete byte of data being sent, the CS pin being deasserted on uneven byte boundaries, or because the memory location to be programmed is protected or locked down. 13 8693A–DFLASH–8/10 While the device is programming, the Status Register can be read and will indicate that the device is busy. For faster throughput, it is recommended that the Status Register be polled rather than waiting the tBP or tPP time to determine if the data bytes have finished programming. At some point before the program cycle completes, the WEL bit in the Status Register will be reset back to the logical “0” state. The device also incorporates an intelligent programming algorithm that can detect when a byte location fails to program properly. If a programming error arises, it will be indicated by the EPE bit in the Status Register. Figure 8-3. CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 Dual-Input Byte Program SCK OPCODE ADDRESS BITS A23-A0 0 1 0 A MSB INPUT DATA BYTE A A D6 D4 D2 D0 SI 1 MSB 0 1 0 0 A A A A A A SOI HIGH-IMPEDANCE D7 D5 D3 D1 MSB Figure 8-4. CS Dual-Input Page Program SCK 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 37 38 39 OPCODE ADDRESS BITS A23-A0 0 1 0 A MSB INPUT DATA BYTE 1 A A INPUT DATA BYTE 2 INPUT DATA BYTE n D6 D4 D2 D0 SI 1 MSB 0 1 0 0 A A A A A A D6 D4 D2 D0 D6 D4 D2 D0 SOI HIGH-IMPEDANCE D7 D5 D3 D1 D7 D5 D3 D1 MSB MSB D7 D5 D3 D1 MSB 8.3 Block Erase A block of 4-, 32-, or 64-Kbytes can be erased (all bits set to the logical “1” state) in a single operation by using one of three different opcodes for the Block Erase command. An opcode of 20h is used for a 4-Kbyte erase, an opcode of 52h is used for a 32-Kbyte erase, and an opcode of D8h is used for a 64-Kbyte erase. Before a Block Erase command can be started, the Write Enable command must have been previously issued to the device to set the WEL bit of the Status Register to a logical “1” state. To perform a Block Erase, the CS pin must first be asserted and the appropriate opcode (20h, 52h, or D8h) must be clocked into the device. After the opcode has been clocked in, the three address bytes specifying an address within the 4-, 32-, or 64-Kbyte block to be erased must be clocked in. Any additional data clocked into the device will be ignored. When the CS pin is deasserted, the device will erase the appropriate block. The erasing of the block is internally selftimed and should take place in a time of tBLKE. 14 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] Since the Block Erase command erases a region of bytes, the lower order address bits do not need to be decoded by the device. Therefore, for a 4-Kbyte erase, address bits A11-A0 will be ignored by the device and their values can be either a logical “1” or “0”. For a 32-Kbyte erase, address bits A14-A0 will be ignored, and for a 64-Kbyte erase, address bits A15-A0 will be ignored by the device. Despite the lower order address bits not being decoded by the device, the complete three address bytes must still be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation and no erase operation will be performed. If the address specified by A23-A0 points to a memory location within a sector that is in the protected or locked down state, then the Block Erase command will not be executed, and the device will return to the idle state once the CS pin has been deasserted. The WEL bit in the Status Register will be reset back to the logical “0” state if the erase cycle aborts due to an incomplete address being sent, the CS pin being deasserted on uneven byte boundaries, or because a memory location within the region to be erased is protected or locked down. While the device is executing a successful erase cycle, the Status Register can be read and will indicate that the device is busy. For faster throughput, it is recommended that the Status Register be polled rather than waiting the tBLKE time to determine if the device has finished erasing. At some point before the erase cycle completes, the WEL bit in the Status Register will be reset back to the logical “0” state. The device also incorporates an intelligent erase algorithm that can detect when a byte location fails to erase properly. If an erase error occurs, it will be indicated by the EPE bit in the Status Register. Figure 8-5. Block Erase CS 0 1 2 3 4 5 6 7 8 9 10 11 12 26 27 28 29 30 31 SCK OPCODE ADDRESS BITS A23-A0 C C A MSB SI C MSB C C C C C A A A A A A A A A A A SO HIGH-IMPEDANCE 8.4 Chip Erase The entire memory array can be erased in a single operation by using the Chip Erase command. Before a Chip Erase command can be started, the Write Enable command must have been previously issued to the device to set the WEL bit of the Status Register to a logical “1” state. Two opcodes, 60h and C7h, can be used for the Chip Erase command. There is no difference in device functionality when utilizing the two opcodes, so they can be used interchangeably. To perform a Chip Erase, one of the two opcodes (60h or C7h) must be clocked into the device. Since the entire memory array is to be erased, no address bytes need to be clocked into the device, and any data clocked in after the opcode will be ignored. When the CS pin is deasserted, the device will erase the entire memory array. The erasing of the device is internally selftimed and should take place in a time of tCHPE. 15 8693A–DFLASH–8/10 The complete opcode must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, no erase will be performed. In addition, if any sector of the memory array is in the protected or locked down state, then the Chip Erase command will not be executed, and the device will return to the idle state once the CS pin has been deasserted. The WEL bit in the Status Register will be reset back to the logical “0” state if the CS pin is deasserted on uneven byte boundaries or if a sector is in the protected or locked down state. While the device is executing a successful erase cycle, the Status Register can be read and will indicate that the device is busy. For faster throughput, it is recommended that the Status Register be polled rather than waiting the tCHPE time to determine if the device has finished erasing. At some point before the erase cycle completes, the WEL bit in the Status Register will be reset back to the logical “0” state. The device also incorporates an intelligent erase algorithm that can detect when a byte location fails to erase properly. If an erase error occurs, it will be indicated by the EPE bit in the Status Register. Figure 8-6. Chip Erase CS 0 1 2 3 4 5 6 7 SCK OPCODE SI C MSB C C C C C C C SO HIGH-IMPEDANCE 8.5 Program/Erase Suspend In some code plus data storage applications, it is often necessary to process certain high-level system interrupts that require relatively immediate reading of code or data from the Flash memory. In such an instance, it may not be possible for the system to wait the microseconds or milliseconds required for the Flash memory to complete a program or erase cycle. The Program/Erase Suspend command allows a program or erase operation in progress to a particular 64-Kbyte sector of the Flash memory array to be suspended so that other device operations can be performed. For example, by suspending an erase operation to a particular sector, the system can perform functions such as a program or read operation within another 64-Kbyte sector in the device. Other device operations, such as a Read Status Register, can also be performed while a program or erase operation is suspended. Table 8-1 outlines the operations that are allowed and not allowed during a program or erase suspend. Since the need to suspend a program or erase operation is immediate, the Write Enable command does not need to be issued prior to the Program/Erase Suspend command being issued. Therefore, the Program/Erase Suspend command operates independently of the state of the WEL bit in the Status Register. To perform a Program/Erase Suspend, the CS pin must first be asserted and the opcode of B0h must be clocked into the device. No address bytes need to be clocked into the device, and any data clocked in after the opcode will be ignored. When the CS pin is deasserted, the program or 16 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] erase operation currently in progress will be suspended within a time of tSUSP. The Program Suspend (PS) bit or the Erase Suspend (ES) bit in the Status Register will then be set to the logical “1” state to indicate that the program or erase operation has been suspended. In addition, the RDY/BSY bit in the Status Register will indicate that the device is ready for another operation. The complete opcode must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, no suspend operation will be performed. Read operations are not allowed to a 64-Kbyte sector that has had its program or erase operation suspended. If a read is attempted to a suspended sector, then the device will output undefined data. Therefore, when performing a Read Array operation to an unsuspended sector and the device’s internal address counter increments and crosses the sector boundary to a suspended sector, the device will then start outputting undefined data continuously until the address counter increments and crosses a sector boundary to an unsuspended sector. A program operation is not allowed to a sector that has been erase suspended. If a program operation is attempted to an erase suspended sector, then the program operation will abort and the WEL bit in the Status Register will be reset back to the logical “0” state. Likewise, an erase operation is not allowed to a sector that has been program suspended. If attempted, the erase operation will abort and the WEL bit in the Status Register will be reset to a logical “0” state. During an Erase Suspend, a program operation to a different 64-Kbyte sector can be started and subsequently suspended. This results in a simultaneous Erase Suspend/Program Suspend condition and will be indicated by the states of both the ES and PS bits in the Status Register being set to the logical “1” state. If a Reset operation (see “Reset” on page 40) is performed while a sector is erase suspended, the suspend operation will abort and the contents of the block in the suspended sector will be left in an undefined state. However, if a Reset is performed while a sector is program suspended, the suspend operation will abort but only the contents of the page that was being programmed and subsequently suspended will be undefined. The remaining pages in the 64-Kbyte sector will retain their previous contents. If an attempt is made to perform an operation that is not allowed during a program or erase suspend, such as a Protect Sector operation, then the device will simply ignore the opcode and no operation will be performed. The state of the WEL bit in the Status Register, as well as the SPRL (Sector Protection Registers Locked) and SLE (Sector Lockdown Enabled) bits, will not be affected. 17 8693A–DFLASH–8/10 Table 8-1. Command . Operations Allowed and Not Allowed During a Program or Erase Suspend Operation During Program Suspend Operation During Erase Suspend Read Commands Read Array (All Opcodes) Program and Erase Commands Block Erase Chip Erase Byte/Page Program (All Opcodes) Program/Erase Suspend Program/Erase Resume Protection Commands Write Enable Write Disable Protect Sector Unprotect Sector Global Protect/Unprotect Read Sector Protection Registers Security Commands Sector Lockdown Freeze Sector Lockdown State Read Sector Lockdown Registers Program OTP Security Register Read OTP Security Register Status Register Commands Read Status Register Write Status Register (All Opcodes) Miscellaneous Commands Reset Read Manufacturer and Device ID Deep Power-Down Resume from Deep Power-Down Allowed Allowed Not Allowed Not Allowed Allowed Allowed Not Allowed Not Allowed Allowed Not Allowed Allowed Not Allowed Not Allowed Not Allowed Allowed Not Allowed Allowed Not Allowed Not Allowed Allowed Not Allowed Allowed Not Allowed Not Allowed Not Allowed Not Allowed Not Allowed Allowed Allowed Allowed Not Allowed Not Allowed Not Allowed Allowed Not Allowed Not Allowed Not Allowed Not Allowed Allowed Not Allowed Not Allowed Allowed Allowed Allowed Allowed Allowed 18 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] Figure 8-7. Program/Erase Suspend CS 0 1 2 3 4 5 6 7 SCK OPCODE SI 1 MSB 0 1 1 0 0 0 0 SO HIGH-IMPEDANCE 8.6 Program/Erase Resume The Program/Erase Resume command allows a suspended program or erase operation to be resumed and continue programming a Flash page or erasing a Flash memory block where it left off. As with the Program/Erase Suspend command, the Write Enable command does not need to be issued prior to the Program/Erase Resume command being issued. Therefore, the Program/Erase Resume command operates independently of the state of the WEL bit in the Status Register. To perform a Program/Erase Resume, the CS pin must first be asserted and the opcode of D0h must be clocked into the device. No address bytes need to be clocked into the device, and any data clocked in after the opcode will be ignored. When the CS pin is deasserted, the program or erase operation currently suspended will be resumed within a time of tRES. The PS bit or the ES bit in the Status Register will then be reset back to the logical “0” state to indicate that the program or erase operation is no longer suspended. In addition, the RDY/BSY bit in the Status Register will indicate that the device is busy performing a program or erase operation. The complete opcode must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, no resume operation will be performed. During a simultaneous Erase Suspend/Program Suspend condition, issuing the Program/Erase Resume command will result in the program operation resuming first. After the program operation has been completed, the Program/Erase Resume command must be issued again in order for the erase operation to be resumed. While the device is busy resuming a program or erase operation, any attempts at issuing the Program/Erase Suspend command will be ignored. Therefore, if a resumed program or erase operation needs to be subsequently suspended again, the system must either wait the entire tRES time before issuing the Program/Erase Suspend command, or it must check the status of the RDY/BSY bit or the appropriate PS or ES bit in the Status Register to determine if the previously suspended program or erase operation has resumed. 19 8693A–DFLASH–8/10 Figure 8-8. Program/Erase Resume CS 0 1 2 3 4 5 6 7 SCK OPCODE SI 1 MSB 1 0 1 0 0 0 0 SO HIGH-IMPEDANCE 9. Protection Commands and Features 9.1 Write Enable The Write Enable command is used to set the Write Enable Latch (WEL) bit in the Status Register to a logical “1” state. The WEL bit must be set before a Byte/Page Program, erase, Protect Sector, Unprotect Sector, Sector Lockdown, Freeze Sector Lockdown State, Program OTP Security Register, or Write Status Register command can be executed. This makes the issuance of these commands a two step process, thereby reducing the chances of a command being accidentally or erroneously executed. If the WEL bit in the Status Register is not set prior to the issuance of one of these commands, then the command will not be executed. To issue the Write Enable command, the CS pin must first be asserted and the opcode of 06h must be clocked into the device. No address bytes need to be clocked into the device, and any data clocked in after the opcode will be ignored. When the CS pin is deasserted, the WEL bit in the Status Register will be set to a logical “1”. The complete opcode must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation and the state of the WEL bit will not change. Figure 9-1. Write Enable CS 0 1 2 3 4 5 6 7 SCK OPCODE SI 0 MSB 0 0 0 0 1 1 0 SO HIGH-IMPEDANCE 20 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] 9.2 Write Disable The Write Disable command is used to reset the Write Enable Latch (WEL) bit in the Status Register to the logical "0" state. With the WEL bit reset, all Byte/Page Program, erase, Protect Sector, Unprotect Sector, Sector Lockdown, Freeze Sector Lockdown State, Program OTP Security Register, and Write Status Register commands will not be executed. Other conditions can also cause the WEL bit to be reset; for more details, refer to the WEL bit section of the Status Register description. To issue the Write Disable command, the CS pin must first be asserted and the opcode of 04h must be clocked into the device. No address bytes need to be clocked into the device, and any data clocked in after the opcode will be ignored. When the CS pin is deasserted, the WEL bit in the Status Register will be reset to a logical “0”. The complete opcode must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation and the state of the WEL bit will not change. Figure 9-2. Write Disable CS 0 1 2 3 4 5 6 7 SCK OPCODE SI 0 MSB 0 0 0 0 1 0 0 SO HIGH-IMPEDANCE 9.3 Protect Sector Every physical 64-Kbyte sector of the device has a corresponding single-bit Sector Protection Register that is used to control the software protection of a sector. Upon device power-up, each Sector Protection Register will default to the logical “1” state indicating that all sectors are protected and cannot be programmed or erased. Issuing the Protect Sector command to a particular sector address will set the corresponding Sector Protection Register to the logical “1” state. The following table outlines the two states of the Sector Protection Registers. Table 9-1. Value 0 1 Sector Protection Register Values Sector Protection Status Sector is unprotected and can be programmed and erased. Sector is protected and cannot be programmed or erased. This is the default state. Before the Protect Sector command can be issued, the Write Enable command must have been previously issued to set the WEL bit in the Status Register to a logical “1”. To issue the Protect Sector command, the CS pin must first be asserted and the opcode of 36h must be clocked into the device followed by three address bytes designating any address within the sector to be protected. Any additional data clocked into the device will be ignored. When the C S pin is deasserted, the Sector Protection Register corresponding to the physical sector addressed by 21 8693A–DFLASH–8/10 A23-A0 will be set to the logical “1” state, and the sector itself will then be protected from program and erase operations. In addition, the WEL bit in the Status Register will be reset back to the logical “0” state. The complete three address bytes must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation. When the device aborts the Protect Sector operation, the state of the Sector Protection Register will be unchanged, and the WEL bit in the Status Register will be reset to a logical “0”. As a safeguard against accidental or erroneous protecting or unprotecting of sectors, the Sector Protection Registers can themselves be locked from updates by using the SPRL (Sector Protection Registers Locked) bit of the Status Register (please refer to the Status Register description for more details). If the Sector Protection Registers are locked, then any attempts to issue the Protect Sector command will be ignored, and the device will reset the WEL bit in the Status Register back to a logical “0” and return to the idle state once the CS pin has been deasserted. Figure 9-3. Protect Sector CS 0 1 2 3 4 5 6 7 8 9 10 11 12 26 27 28 29 30 31 SCK OPCODE ADDRESS BITS A23-A0 1 1 0 A MSB SI 0 MSB 0 1 1 0 A A A A A A A A A A A SO HIGH-IMPEDANCE 9.4 Unprotect Sector Issuing the Unprotect Sector command to a particular sector address will reset the corresponding Sector Protection Register to the logical “0” state (see Table 9-1 for Sector Protection Register values). Every physical sector of the device has a corresponding single-bit Sector Protection Register that is used to control the software protection of a sector. Before the Unprotect Sector command can be issued, the Write Enable command must have been previously issued to set the WEL bit in the Status Register to a logical “1”. To issue the Unprotect Sector command, the CS pin must first be asserted and the opcode of 39h must be clocked into the device. After the opcode has been clocked in, the three address bytes designating any address within the sector to be unprotected must be clocked in. Any additional data clocked into the device after the address bytes will be ignored. When the CS pin is deasserted, the Sector Protection Register corresponding to the sector addressed by A23-A0 will be reset to the logical “0” state, and the sector itself will be unprotected. In addition, the WEL bit in the Status Register will be reset back to the logical “0” state. The complete three address bytes must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation, the state of the Sector Protection Register will be unchanged, and the WEL bit in the Status Register will be reset to a logical “0”. 22 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] As a safeguard against accidental or erroneous locking or unlocking of sectors, the Sector Protection Registers can themselves be locked from updates by using the SPRL (Sector Protection Registers Locked) bit of the Status Register (please refer to the Status Register description for more details). If the Sector Protection Registers are locked, then any attempts to issue the Unprotect Sector command will be ignored, and the device will reset the WEL bit in the Status Register back to a logical “0” and return to the idle state once the CS pin has been deasserted. Figure 9-4. Unprotect Sector CS 0 1 2 3 4 5 6 7 8 9 10 11 12 26 27 28 29 30 31 SCK OPCODE ADDRESS BITS A23-A0 0 0 1 A MSB SI 0 MSB 0 1 1 1 A A A A A A A A A A A SO HIGH-IMPEDANCE 9.5 Global Protect/Unprotect The Global Protect and Global Unprotect features can work in conjunction with the Protect Sector and Unprotect Sector functions. For example, a system can globally protect the entire memory array and then use the Unprotect Sector command to individually unprotect certain sectors and individually reprotect them later by using the Protect Sector command. Likewise, a system can globally unprotect the entire memory array and then individually protect certain sectors as needed. Performing a Global Protect or Global Unprotect is accomplished by writing a certain combination of data to the Status Register using the Write Status Register Byte 1 command (see “Write Status Register Byte 1” on page 38 for command execution details). The Write Status Register command is also used to modify the SPRL (Sector Protection Registers Locked) bit to control hardware and software locking. To perform a Global Protect, the appropriate WP pin and SPRL conditions must be met, and the system must write a logical “1” to bits five, four, three, and two of the first byte of the Status Register. Conversely, to perform a Global Unprotect, the same WP and SPRL conditions must be met but the system must write a logical “0” to bits five, four, three, and two of the first byte of the Status Register. Table 9-2 details the conditions necessary for a Global Protect or Global Unprotect to be performed. Sectors that have been erase or program suspended must remain in the unprotected state. If a Global Protect operation is attempted while a sector is erase or program suspended, the protection operation will abort, the protection states of all sectors in the Flash memory array will not change, and WEL bit in the Status Register will be reset back to a logical “0”. 23 8693A–DFLASH–8/10 Table 9-2. Valid SPRL and Global Protect/Unprotect Conditions New Write Status Register Byte 1 Data Bit 76543210 0x0000xx 0x0001xx 0x1110xx 0x1111xx Protection Operation Global Unprotect – all Sector Protection Registers reset to 0 No change to current protection. No change to current protection. No change to current protection. Global Protect – all Sector Protection Registers set to 1 Global Unprotect – all Sector Protection Registers reset to 0 No change to current protection. No change to current protection. No change to current protection. Global Protect – all Sector Protection Registers set to 1 WP State Current SPRL Value New SPRL Value 0 0 0 0 0 1 1 1 1 1 0 0 1x0000xx 1x0001xx 1x1110xx 1x1111xx No change to the current protection level. All sectors currently protected will remain protected and all sectors currently unprotected will remain unprotected. 0 1 xxxxxxxx The Sector Protection Registers are hard-locked and cannot be changed when the WP pin is LOW and the current state of SPRL is 1. Therefore, a Global Protect/Unprotect will not occur. In addition, the SPRL bit cannot be changed (the WP pin must be HIGH in order to change SPRL back to a 0). Global Unprotect – all Sector Protection Registers reset to 0 No change to current protection. No change to current protection. No change to current protection. Global Protect – all Sector Protection Registers set to 1 Global Unprotect – all Sector Protection Registers reset to 0 No change to current protection. No change to current protection. No change to current protection. Global Protect – all Sector Protection Registers set to 1 No change to the current protection level. All sectors currently protected will remain protected, and all sectors currently unprotected will remain unprotected. The Sector Protection Registers are soft-locked and cannot be changed when the current state of SPRL is 1. Therefore, a Global Protect/Unprotect will not occur. However, the SPRL bit can be changed back to a 0 from a 1 since the WP pin is HIGH. To perform a Global Protect/Unprotect, the Write Status Register command must be issued again after the SPRL bit has been changed from a 1 to a 0. 0 0 0 0 0 1 1 1 1 1 0 0 0 0 0 1 1 1 1 1 0x0000xx 0x0001xx 0x1110xx 0x1111xx 1 0 1x0000xx 1x0001xx 1x1110xx 1x1111xx 0x0000xx 0x0001xx 0x1110xx 0x1111xx 1 1 1x0000xx 1x0001xx 1x1110xx 1x1111xx Essentially, if the SPRL bit of the Status Register is in the logical “0” state (Sector Protection Registers are not locked), then writing a 00h to the first byte of the Status Register will perform a Global Unprotect without changing the state of the SPRL bit. Similarly, writing a 7Fh to the first byte of the Status Register will perform a Global Protect and keep the SPRL bit in the logical “0” state. The SPRL bit can, of course, be changed to a logical “1” by writing an FFh if software-locking or hardware-locking is desired along with the Global Protect. 24 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] If the desire is to only change the SPRL bit without performing a Global Protect or Global Unprotect, then the system can simply write a 0Fh to the first byte of the Status Register to change the SPRL bit from a logical “1” to a logical “0” provided the WP pin is deasserted. Likewise, the system can write an F0h to change the SPRL bit from a logical “0” to a logical “1” without affecting the current sector protection status (no changes will be made to the Sector Protection Registers). When writing to the first byte of the Status Register, bits five, four, three, and two will not actually be modified but will be decoded by the device for the purposes of the Global Protect and Global Unprotect functions. Only bit seven, the SPRL bit, will actually be modified. Therefore, when reading the first byte of the Status Register, bits five, four, three, and two will not reflect the values written to them but will instead indicate the status of the WP pin and the sector protection status. Please refer to “Read Status Register” on page 33 and Table 11-1 on page 34 for details on the Status Register format and what values can be read for bits five, four, three, and two. 9.6 Read Sector Protection Registers The Sector Protection Registers can be read to determine the current software protection status of each sector. Reading the Sector Protection Registers, however, will not determine the status of the WP pin. To read the Sector Protection Register for a particular sector, the CS pin must first be asserted and the opcode of 3Ch must be clocked in. Once the opcode has been clocked in, three address bytes designating any address within the sector must be clocked in. After the last address byte has been clocked in, the device will begin outputting data on the SO pin during every subsequent clock cycle. The data being output will be a repeating byte of either FFh or 00h to denote the value of the appropriate Sector Protection Register. At clock frequencies above fCLK, the first byte of data output will not be valid. Therefore, if operating at clock frequencies above fCLK, at least two bytes of data must be clocked out from the device in order to determine the correct status of the appropriate Sector Protection Register. Table 9-3. Output Data 00h FFh Read Sector Protection Register - Output Data Sector Protection Register Value Sector Protection Register value is 0 (sector is unprotected). Sector Protection Register value is 1 (sector is protected). Deasserting the CS pin will terminate the read operation and put the SO pin into a high-impedance state. The CS pin can be deasserted at any time and does not require that a full byte of data be read. In addition to reading the individual Sector Protection Registers, the Software Protection Status (SWP) bits in the Status Register can be read to determine if all, some, or none of the sectors are software protected (refer to “Read Status Register” on page 33 for more details). 25 8693A–DFLASH–8/10 Figure 9-5. CS Read Sector Protection Register SCK 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 37 38 39 40 OPCODE ADDRESS BITS A23-A0 1 0 0 A MSB SI 0 MSB 0 1 1 1 A A A A A A A A DATA BYTE SO HIGH-IMPEDANCE D MSB D D D D D D D D MSB D 9.7 Protected States and the Write Protect (WP) Pin The WP pin is not linked to the memory array itself and has no direct effect on the protection status or lockdown status of the memory array. Instead, the WP pin, in conjunction with the SPRL (Sector Protection Registers Locked) bit in the Status Register, is used to control the hardware locking mechanism of the device. For hardware locking to be active, two conditions must be metthe WP pin must be asserted and the SPRL bit must be in the logical “1” state. When hardware locking is active, the Sector Protection Registers are locked and the SPRL bit itself is also locked. Therefore, sectors that are protected will be locked in the protected state, and sectors that are unprotected will be locked in the unprotected state. These states cannot be changed as long as hardware locking is active, so the Protect Sector, Unprotect Sector, and Write Status Register commands will be ignored. In order to modify the protection status of a sector, the WP pin must first be deasserted, and the SPRL bit in the Status Register must be reset back to the logical “0” state using the Write Status Register command. When resetting the SPRL bit back to a logical “0”, it is not possible to perform a Global Protect or Global Unprotect at the same time since the Sector Protection Registers remain soft-locked until after the Write Status Register command has been executed. If the WP pin is permanently connected to GND, then once the SPRL bit is set to a logical “1”, the only way to reset the bit back to the logical “0” state is to power-cycle the device. This allows a system to power-up with all sectors software protected but not hardware locked. Therefore, sectors can be unprotected and protected as needed and then hardware locked at a later time by simply setting the SPRL bit in the Status Register. When the WP pin is deasserted, or if the WP pin is permanently connected to VCC, the SPRL bit in the Status Register can still be set to a logical “1” to lock the Sector Protection Registers. This provides a software locking ability to prevent erroneous Protect Sector or Unprotect Sector commands from being processed. When changing the SPRL bit to a logical “1” from a logical “0”, it is also possible to perform a Global Protect or Global Unprotect at the same time by writing the appropriate values into bits five, four, three, and two of the first byte of the Status Register. Tables 9-4 and 9-5 detail the various protection and locking states of the device. 26 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] Table 9-4. WP X (Don't Care) Note: 1. “n” represents a sector number Sector Protection Register States Sector Protection Register n(1) 0 1 Sector n(1) Unprotected Protected Table 9-5. WP Hardware and Software Locking Locking SPRL Change Allowed Sector Protection Registers Unlocked and modifiable using the Protect and Unprotect Sector commands. Global Protect and Unprotect can also be performed. Locked in current state. Protect and Unprotect Sector commands will be ignored. Global Protect and Unprotect cannot be performed. Unlocked and modifiable using the Protect and Unprotect Sector commands. Global Protect and Unprotect can also be performed. Locked in current state. Protect and Unprotect Sector commands will be ignored. Global Protect and Unprotect cannot be performed. SPRL 0 0 Can be modified from 0 to 1 0 1 Hardware Locked Locked 1 0 Can be modified from 0 to 1 1 1 Software Locked Can be modified from 1 to 0 27 8693A–DFLASH–8/10 10. Security Commands 10.1 Sector Lockdown Certain applications require that portions of the Flash memory array be permanently protected against malicious attempts at altering program code, data modules, security information, or encryption/decryption algorithms, keys, and routines. To address these applications, the device incorporates a sector lockdown mechanism that allows any combination of individual 64-Kbyte sectors to be permanently locked so that they become read only. Once a sector is locked down, it can never be erased or programmed again, and it can never be unlocked from the locked down state. Each 64-Kbyte physical sector has a corresponding single-bit Sector Lockdown Register that is used to control the lockdown status of that sector. These registers are nonvolatile and will retain their state even after a device power-cycle or reset operation. The following table outlines the two states of the Sector Lockdown Registers. Table 10-1. Value 0 1 Sector Lockdown Register Values Sector Lockdown Status Sector is not locked down and can be programmed and erased. This is the default state. Sector is permanently locked down and can never be programmed or erased again. Issuing the Sector Lockdown command to a particular sector address will set the corresponding Sector Lockdown Register to the logical “1” state. Each Sector Lockdown Register can only be set once; therefore, once set to the logical “1” state, a Sector Lockdown Register cannot be reset back to the logical “0” state. Before the Sector Lockdown command can be issued, the Write Enable command must have been previously issued to set the WEL bit in the Status Register to a logical “1”. In addition, the Sector Lockdown Enabled (SLE) bit in the Status Register must have also been previously set to the logical “1” state by using the Write Status Register Byte 2 command (see “Write Status Register Byte 2” on page 39). To issue the Sector Lockdown command, the CS pin must first be asserted and the opcode of 33h must be clocked into the device followed by three address bytes designating any address within the 64-Kbyte sector to be locked down. After the three address bytes have been clocked in, a confirmation byte of D0h must also be clocked in immediately following the three address bytes. Any additional data clocked into the device after the first byte of data will be ignored. When the CS pin is deasserted, the Sector Lockdown Register corresponding to the sector addressed by A23-A0 will be set to the logical “1” state, and the sector itself will then be permanently locked down from program and erase operations within a time of tLOCK. In addition, the WEL bit in the Status Register will be reset back to the logical “0” state. The complete three address bytes and the correct confirmation byte value of D0h must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation. When the device aborts the Sector Lockdown operation, the state of the corresponding Sector Lockdown Register as well as the SLE bit in the Status Register will be unchanged; however, the WEL bit in the Status Register will be reset to a logical “0”. As a safeguard against accidental or erroneous locking down of sectors, the Sector Lockdown command can be enabled and disabled as needed by using the SLE bit in the Status Register. In addition, the current sector lockdown state can be frozen so that no further modifications to 28 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] the Sector Lockdown Registers can be made (see “Freeze Sector Lockdown State” below). If the Sector Lockdown command is disabled or if the sector lockdown state is frozen, then any attempts to issue the Sector Lockdown command will be ignored, and the device will reset the WEL bit in the Status Register back to a logical “0” and return to the idle state once the CS pin has been deasserted. Figure 10-1. Sector Lockdown CS 0 1 2 3 4 5 6 7 8 9 29 30 31 32 33 34 35 36 37 38 39 SCK OPCODE ADDRESS BITS A23-A0 0 1 1 A MSB CONFIRMATION BYTE IN 1 MSB SI 0 MSB 0 1 1 0 A A A A A 1 0 1 0 0 0 0 SO HIGH-IMPEDANCE 10.2 Freeze Sector Lockdown State The current sector lockdown state can be permanently frozen so that no further modifications to the Sector Lockdown Registers can be made; therefore, the Sector Lockdown command will be permanently disabled, and no additional sectors can be locked down aside from those already locked down. Any attempts to issue the Sector Lockdown command after the sector lockdown state has been frozen will be ignored. Before the Freeze Sector Lockdown State command can be issued, the Write Enable command must have been previously issued to set the WEL bit in the Status Register to a logical “1”. In addition, the Sector Lockdown Enabled (SLE) bit in the Status Register must have also been previously set to the logical “1” state. To issue the Freeze Sector Lockdown State command, the CS pin must first be asserted and the opcode of 34h must be clocked into the device followed by three command specific address bytes of 55AA40h. After the three address bytes have been clocked in, a confirmation byte of D0h must be clocked in immediately following the three address bytes. Any additional data clocked into the device will be ignored. When the CS pin is deasserted, the current sector lockdown state will be permanently frozen within a time of tLOCK. In addition, the WEL bit in the Status Register will be reset back to the logical “0” state, and the SLE bit will be permanently reset to a logical “0” to indicate that the Sector Lockdown command is permanently disabled. The complete and correct three address bytes and the confirmation byte must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation. When the device aborts the Freeze Sector Lockdown State operation, the WEL bit in the Status Register will be reset to a logical “0”; however, the state of the SLE bit will be unchanged. 29 8693A–DFLASH–8/10 Figure 10-2. Freeze Sector Lockdown State CS 0 1 2 3 4 5 6 7 8 9 29 30 31 32 33 34 35 36 37 38 39 SCK OPCODE ADDRESS BITS A23-A0 1 0 0 0 MSB CONFIRMATION BYTE IN 1 MSB SI 0 MSB 0 1 1 0 1 0 0 0 0 1 0 1 0 0 0 0 SO HIGH-IMPEDANCE 10.3 Read Sector Lockdown Registers The Sector Lockdown Registers can be read to determine the current lockdown status of each physical 64-Kbyte sector. To read the Sector Lockdown Register for a particular 64-Kbyte sector, the CS pin must first be asserted and the opcode of 35h must be clocked in. Once the opcode has been clocked in, three address bytes designating any address within the 64-Kbyte sector must be clocked in. After the address bytes have been clocked in, data will be output on the SO pin during every subsequent clock cycle. The data being output will be a repeating byte of either FFh or 00h to denote the value of the appropriate Sector Lockdown Register. At clock frequencies above fCLK, the first byte of data output will not be valid. Therefore, if operating at clock frequencies above fCLK, at least two bytes of data must be clocked out from the device in order to determine the correct status of the appropriate Sector Lockdown Register. Table 10-2. Output Data 00h FFh Read Sector Lockdown Register – Output Data Sector Lockdown Register Value Sector Lockdown Register value is 0 (sector is not locked down). Sector Lockdown Register value is 1 (sector is permanently locked down). Deasserting the CS pin will terminate the read operation and put the SO pin into a high-impedance state. The CS pin can be deasserted at any time and does not require that a full byte of data be read. Figure 10-3. Read Sector Lockdown Register CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 SCK OPCODE ADDRESS BITS A23-A0 1 0 1 A MSB DON'T CARE A A X MSB SI 0 MSB 0 1 1 0 A A A A A A X X X X X X X DATA BYTE SO HIGH-IMPEDANCE D MSB D D D D D D D D MSB D 30 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] 10.4 Program OTP Security Register The device contains a specialized OTP (One-Time Programmable) Security Register that can be used for purposes such as unique device serialization, system-level Electronic Serial Number (ESN) storage, locked key storage, etc. The OTP Security Register is independent of the main Flash memory array and is comprised of a total of 128-bytes of memory divided into two portions. The first 64-bytes (byte locations 0 through 63) of the OTP Security Register are allocated as a one-time user-programmable space. Once these 64-bytes have been programmed, they cannot be erased or reprogrammed. The remaining 64-bytes of the OTP Security Register (byte locations 64 through 127) are factory programmed by Atmel and will contain a unique value for each device. The factory programmed data is fixed and cannot be changed. Table 10-3. OTP Security Register Security Register Byte Number 0 1 ... 62 63 64 65 ... 126 127 One-Time User Programmable Factory Programmed by Atmel The user-programmable portion of the OTP Security Register does not need to be erased before it is programmed. In addition, the Program OTP Security Register command operates on the entire 64-byte user-programmable portion of the OTP Security Register at one time. Once the user-programmable space has been programmed with any number of bytes, the user-programmable space cannot be programmed again; therefore, it is not possible to only program the first two bytes of the register and then program the remaining 62-bytes at a later time. Before the Program OTP Security Register command can be issued, the Write Enable command must have been previously issued to set the WEL bit in the Status Register to a logical “1”. To program the OTP Security Register, the CS pin must first be asserted and an opcode of 9Bh must be clocked into the device followed by the three address bytes denoting the first byte location of the OTP Security Register to begin programming at. Since the size of the userprogrammable portion of the OTP Security Register is 64-bytes, the upper order address bits do not need to be decoded by the device. Therefore, address bits A23-A6 will be ignored by the device and their values can be either a logical “1” or “0”. After the address bytes have been clocked in, data can then be clocked into the device and will be stored in the internal buffer. If the starting memory address denoted by A23-A0 does not start at the beginning of the OTP Security Register memory space (A5-A0 are not all 0), then special circumstances regarding which OTP Security Register locations to be programmed will apply. In this situation, any data that is sent to the device that goes beyond the end of the 64-byte user-programmable space will wrap around back to the beginning of the OTP Security Register. For example, if the starting address denoted by A23-A0 is 00003Eh, and three bytes of data are sent to the device, then the first two bytes of data will be programmed at OTP Security Register addresses 00003Eh and 00003Fh while the last byte of data will be programmed at address 000000h. The remaining bytes in the OTP Security Register (addresses 000001h through 00003Dh) will not be programmed and will remain in the erased state (FFh). In addition, if more than 64-bytes of data are sent to the device, then only the last 64-bytes sent will be latched into the internal buffer. When the CS pin is deasserted, the device will take the data stored in the internal buffer and program it into the appropriate OTP Security Register locations based on the starting address specified by A23-A0 and the number of data bytes sent to the device. If less than 64-bytes of data were sent to the device, then the remaining bytes within the OTP Security Register will not 31 8693A–DFLASH–8/10 be programmed and will remain in the erased state (FFh). The programming of the data bytes is internally self-timed and should take place in a time of tOTPP. It is not possible to suspend the programming of the OTP Security Register. The three address bytes and at least one complete byte of data must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on even byte boundaries (multiples of eight bits); otherwise, the device will abort the operation and the user-programmable portion of the OTP Security Register will not be programmed. The WEL bit in the Status Register will be reset back to the logical “0” state if the OTP Security Register program cycle aborts due to an incomplete address being sent, an incomplete byte of data being sent, the CS pin being deasserted on uneven byte boundaries, or because the user-programmable portion of the OTP Security Register was previously programmed. While the device is programming the OTP Security Register, the Status Register can be read and will indicate that the device is busy. For faster throughput, it is recommended that the Status Register be polled rather than waiting the tOTPP time to determine if the data bytes have finished programming. At some point before the OTP Security Register programming completes, the WEL bit in the Status Register will be reset back to the logical “0” state. If the device is powered-down during the OTP Security Register program cycle, then the contents of the 64-byte user programmable portion of the OTP Security Register cannot be guaranteed and cannot be programmed again. The Program OTP Security Register command utilizes the internal 256-buffer for processing. Therefore, the contents of the buffer will be altered from its previous state when this command is issued. Figure 10-4. Program OTP Security Register CS 0 1 2 3 4 5 6 7 8 9 29 30 31 32 33 34 35 36 37 38 39 SCK OPCODE ADDRESS BITS A23-A0 0 1 1 A MSB DATA IN BYTE 1 D MSB DATA IN BYTE n D D MSB SI 1 MSB 0 0 1 1 A A A A A D D D D D D D D D D D D D SO HIGH-IMPEDANCE 32 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] 10.5 Read OTP Security Register The OTP Security Register can be sequentially read in a similar fashion to the Read Array operation up to the maximum clock frequency specified by fMAX. To read the OTP Security Register, the CS pin must first be asserted and the opcode of 77h must be clocked into the device. After the opcode has been clocked in, the three address bytes must be clocked in to specify the starting address location of the first byte to read within the OTP Security Register. Following the three address bytes, two dummy bytes must be clocked into the device before data can be output. After the three address bytes and the dummy bytes have been clocked in, additional clock cycles will result in OTP Security Register data being output on the SO pin. When the last byte (00007Fh) of the OTP Security Register has been read, the device will continue reading back at the beginning of the register (000000h). No delays will be incurred when wrapping around from the end of the register to the beginning of the register. Deasserting the CS pin will terminate the read operation and put the SO pin into a high-impedance state. The CS pin can be deasserted at any time and does not require that a full byte of data be read. Figure 10-5. Read OTP Security Register CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 SCK OPCODE ADDRESS BITS A23-A0 1 1 1 A MSB DON'T CARE A A X MSB SI 0 MSB 1 1 1 0 A A A A A A X X X X X X X X DATA BYTE 1 SO HIGH-IMPEDANCE D MSB D D D D D D D D MSB D 11. Status Register Commands 11.1 Read Status Register The 2-byte Status Register can be read to determine the device’s ready/busy status, as well as the status of many other functions such as Hardware Locking and Software Protection. The Status Register can be read at any time, including during an internally self-timed program or erase operation. To read the Status Register, the CS pin must first be asserted and the opcode of 05h must be clocked into the device. After the opcode has been clocked in, the device will begin outputting Status Register data on the SO pin during every subsequent clock cycle. After the second byte of the Status Register has been clocked out, the sequence will repeat itself starting again with the first byte of the Status Register as long as the CS pin remains asserted and the clock pin is being pulsed. The data in the Status Register is constantly being updated, so each repeating sequence will output new data. The RDY/BSY status is available for both bytes of the Status Register and is updated for each byte. 33 8693A–DFLASH–8/10 At clock frequencies above fCLK, the first two bytes of data output from the Status Register will not be valid. Therefore, if operating at clock frequencies above fCLK, at least four bytes of data must be clocked out from the device in order to read the correct values of both bytes of the Status Register. Deasserting the CS pin will terminate the Read Status Register operation and put the SO pin into a high-impedance state. The CS pin can be deasserted at any time and does not require that a full byte of data be read. Table 11-1. Bit(1) 7 6 5 SPRL RES EPE Status Register Format – Byte 1 Name Sector Protection Registers Locked Reserved for future use Erase/Program Error Type(2) 0 R/W 1 R R 1 0 Erase or program error detected. WP is asserted. WP is deasserted. All sectors are software unprotected (all Sector Protection Registers are 0). Some sectors are software protected. Read individual Sector Protection Registers to determine which sectors are protected. Reserved for future use. All sectors are software protected (all Sector Protection Registers are 1 – default). Device is not write enabled (default). Device is write enabled. Device is ready. Device is busy with an internal operation. 0 0 Sector Protection Registers are locked. Reserved for future use. Erase or program operation was successful. Description Sector Protection Registers are unlocked (default). 4 WPP Write Protect (WP) Pin Status R 1 00 01 3:2 SWP Software Protection Status R 10 11 0 1 WEL Write Enable Latch Status R 1 0 0 Notes: RDY/BSY Ready/Busy Status R 1 2. R/W = Readable and writeable R = Readable only 1. Only bit 7 of Status Register Byte 1 will be modified when using the Write Status Register Byte 1 command 34 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] Table 11-2. Bit (1) Status Register Format – Byte 2 Name Type(2) R R R R/W 1 0 Reset command is enabled. Sector Lockdown and Freeze Sector Lockdown State commands are disabled (default). Sector Lockdown and Freeze Sector Lockdown State commands are enabled. No sectors are program suspended (default). A sector is program suspended. No sectors are erase suspended (default). A sector is erase suspended. Device is ready. Device is busy with an internal operation. 0 0 0 0 Description Reserved for future use. Reserved for future use. Reserved for future use. Reset command is disabled (default). 7 6 5 4 RES RES RES RSTE Reserved for future use Reserved for future use Reserved for future use Reset Enabled 3 SLE Sector Lockdown Enabled R/W 1 0 2 PS Program Suspend Status R 1 0 1 ES Erase Suspend Status R 1 0 0 Notes: RDY/BSY Ready/Busy Status R 1 1. Only bits 4 and 3 of Status Register Byte 2 will be modified when using the Write Status Register Byte 2 command 2. R/W = Readable and writeable R = Readable only 11.1.1 SPRL Bit The SPRL bit is used to control whether the Sector Protection Registers can be modified or not. When the SPRL bit is in the logical “1” state, all Sector Protection Registers are locked and cannot be modified with the Protect Sector and Unprotect Sector commands (the device will ignore these commands). In addition, the Global Protect and Global Unprotect features cannot be performed. Any sectors that are presently protected will remain protected, and any sectors that are presently unprotected will remain unprotected. When the SPRL bit is in the logical “0” state, all Sector Protection Registers are unlocked and can be modified (the Protect Sector and Unprotect Sector commands, as well as the Global Protect and Global Unprotect features, will be processed as normal). The SPRL bit defaults to the logical “0” state after device power-up. The Reset command has no effect on the SPRL bit. The SPRL bit can be modified freely whenever the WP pin is deasserted. However, if the WP pin is asserted, then the SPRL bit may only be changed from a logical “0” (Sector Protection Registers are unlocked) to a logical “1” (Sector Protection Registers are locked). In order to reset the SPRL bit back to a logical “0” using the Write Status Register Byte 1 command, the WP pin will have to first be deasserted. The SPRL bit is the only bit of Status Register Byte 1 that can be user modified via the Write Status Register Byte 1 command. 35 8693A–DFLASH–8/10 11.1.2 EPE Bit The EPE bit indicates whether the last erase or program operation completed successfully or not. If at least one byte during the erase or program operation did not erase or program properly, then the EPE bit will be set to the logical “1” state. The EPE bit will not be set if an erase or program operation aborts for any reason such as an attempt to erase or program a protected region or a locked down sector, an attempt to erase or program a suspended sector, or if the WEL bit is not set prior to an erase or program operation. The EPE bit will be updated after every erase and program operation. 11.1.3 WPP Bit The WPP bit can be read to determine if the WP pin has been asserted or not. 11.1.4 SWP Bits The SWP bits provide feedback on the software protection status for the device. There are three possible combinations of the SWP bits that indicate whether none, some, or all of the sectors have been protected using the Protect Sector command or the Global Protect feature. If the SWP bits indicate that some of the sectors have been protected, then the individual Sector Protection Registers can be read with the Read Sector Protection Registers command to determine which sectors are in fact protected. 11.1.5 WEL Bit The WEL bit indicates the current status of the internal Write Enable Latch. When the WEL bit is in the logical “0” state, the device will not accept any Byte/Page Program, erase, Protect Sector, Unprotect Sector, Sector Lockdown, Freeze Sector Lockdown State, Program OTP Security Register, or Write Status Register commands. The WEL bit defaults to the logical “0” state after a device power-up or reset operation. In addition, the WEL bit will be reset to the logical “0” state automatically under the following conditions: • Write Disable operation completes successfully • Write Status Register operation completes successfully or aborts • Protect Sector operation completes successfully or aborts • Unprotect Sector operation completes successfully or aborts • Sector Lockdown operation completes successfully or aborts • Freeze Sector Lockdown State operation completes successfully or aborts • Program OTP Security Register operation completes successfully or aborts • Byte/Page Program operation completes successfully or aborts • Block Erase operation completes successfully or aborts • Chip Erase operation completes successfully or aborts • Hold condition aborts If the WEL bit is in the logical “1” state, it will not be reset to a logical “0” if an operation aborts due to an incomplete or unrecognized opcode being clocked into the device before the CS pin is deasserted. In order for the WEL bit to be reset when an operation aborts prematurely, the entire opcode for a Byte/Page Program, erase, Protect Sector, Unprotect Sector, Sector Lockdown, Freeze Sector Lockdown State, Program OTP Security Register, or Write Status Register command must have been clocked into the device. 36 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] 11.1.6 RSTE Bit The RSTE bit is used to enable or disable the Reset command. When the RSTE bit is in the logical “0” state (the default state after power-up), the Reset command is disabled and any attempts to reset the device using the Reset command will be ignored. When the RSTE bit is in the logical “1” state, the Reset command is enabled. The RSTE bit will retain its state as long as power is applied to the device. Once set to the logical “1” state, the RSTE bit will remain in that state until it is modified using the Write Status Register Byte 2 command or until the device has been power cycled. The Reset command itself will not change the state of the RSTE bit. 11.1.7 SLE Bit The SLE bit is used to enable and disable the Sector Lockdown and Freeze Sector Lockdown State commands. When the SLE bit is in the logical “0” state (the default state after power-up), the Sector Lockdown and Freeze Sector Lockdown commands are disabled. If the Sector Lockdown and Freeze Sector Lockdown commands are disabled, then any attempts to issue the commands will be ignored. This provides a safeguard for these commands against accidental or erroneous execution. When the SLE bit is in the logical “1” state, the Sector Lockdown and Freeze Sector Lockdown State commands are enabled. Unlike the WEL bit, the SLE bit does not automatically reset after certain device operations. Therefore, once set, the SLE bit will remain in the logical “1” state until it is modified using the Write Status Register Byte 2 command or until the device has been power cycled. The Reset command has no effect on the SLE bit. If the Freeze Sector Lockdown State command has been issued, then the SLE bit will be permanently reset in the logical “0” state to indicate that the Sector Lockdown command has been disabled. 11.1.8 PS Bit The PS bit indicates whether or not a sector is in the Program Suspend state. 11.1.9 ES Bit The ES bit indicates whether or not a sector is in the Erase Suspend state. 11.1.10 RDY/BSY Bit The RDY/BSY bit is used to determine whether or not an internal operation, such as a program or erase, is in progress. To poll the RDY/BSY bit to detect the completion of a program or erase cycle, new Status Register data must be continually clocked out of the device until the state of the RDY/BSY bit changes from a logical “1” to a logical “0”. 37 8693A–DFLASH–8/10 Figure 11-1. Read Status Register CS 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 SCK OPCODE SI 0 MSB 0 0 0 0 1 0 1 STATUS REGISTER BYTE 1 D MSB STATUS REGISTER BYTE 2 D D MSB STATUS REGISTER BYTE 1 D D MSB SO HIGH-IMPEDANCE D D D D D D D D D D D D D D D D D D D 11.2 Write Status Register Byte 1 The Write Status Register Byte 1 command is used to modify the SPRL bit of the Status Register and/or to perform a Global Protect or Global Unprotect operation. Before the Write Status Register Byte 1 command can be issued, the Write Enable command must have been previously issued to set the WEL bit in the Status Register to a logical “1”. To issue the Write Status Register Byte 1 command, the CS pin must first be asserted and the opcode of 01h must be clocked into the device followed by one byte of data. The one byte of data consists of the SPRL bit value, a don’t care bit, four data bits to denote whether a Global Protect or Unprotect should be performed, and two additional don’t care bits (see Table 11-3). Any additional data bytes that are sent to the device will be ignored. When the CS pin is deasserted, the SPRL bit in the Status Register will be modified, and the WEL bit in the Status Register will be reset back to a logical “0”. The values of bits five, four, three, and two and the state of the SPRL bit before the Write Status Register Byte 1 command was executed (the prior state of the SPRL bit) will determine whether or not a Global Protect or Global Unprotect will be performed. Please refer to “Global Protect/Unprotect” on page 23 for more details. The complete one byte of data must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on even byte boundaries (multiples of eight bits); otherwise, the device will abort the operation, the state of the SPRL bit will not change, no potential Global Protect or Unprotect will be performed, and the WEL bit in the Status Register will be reset back to the logical “0” state. If the WP pin is asserted, then the SPRL bit can only be set to a logical “1”. If an attempt is made to reset the SPRL bit to a logical “0” while the WP pin is asserted, then the Write Status Register Byte 1 command will be ignored, and the WEL bit in the Status Register will be reset back to the logical “0” state. In order to reset the SPRL bit to a logical “0”, the WP pin must be deasserted. Table 11-3. Bit 7 SPRL Write Status Register Byte 1 Format Bit 6 X Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 X Bit 0 X Global Protect/Unprotect 38 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] Figure 11-2. Write Status Register Byte 1 CS 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SCK OPCODE STATUS REGISTER IN BYTE 1 0 0 1 D MSB SI 0 MSB 0 0 0 0 X D D D D X X SO HIGH-IMPEDANCE 11.3 Write Status Register Byte 2 The Write Status Register Byte 2 command is used to modify the RSTE and SLE bits of the Status Register. Using the Write Status Register Byte 2 command is the only way to modify the RSTE and SLE bits in the Status Register during normal device operation, and the SLE bit can only be modified if the sector lockdown state has not been frozen. Before the Write Status Register Byte 2 command can be issued, the Write Enable command must have been previously issued to set the WEL bit in the Status Register to a logical “1”. To issue the Write Status Register Byte 2 command, the CS pin must first be asserted and the opcode of 31h must be clocked into the device followed by one byte of data. The one byte of data consists of three don’t care bits, the RSTE bit value, the SLE bit value, and three additional don’t care bits (see Table 11-4). Any additional data bytes that are sent to the device will be ignored. When the CS pin is deasserted, the RSTE and SLE bits in the Status Register will be modified, and the WEL bit in the Status Register will be reset back to a logical “0”. The SLE bit will only be modified if the Freeze Sector Lockdown State command has not been previously issued. The complete one byte of data must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on even byte boundaries (multiples of eight bits); otherwise, the device will abort the operation, the state of the RSTE and SLE bits will not change, and the WEL bit in the Status Register will be reset back to the logical “0” state. Table 11-4. Bit 7 X Write Status Register Byte 2 Format Bit 6 X Bit 5 X Bit 4 RSTE Bit 3 SLE Bit 2 X Bit 1 X Bit 0 X 39 8693A–DFLASH–8/10 Figure 11-3. Write Status Register Byte 2 CS 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SCK OPCODE STATUS REGISTER IN BYTE 2 0 0 1 X MSB SI 0 MSB 0 1 1 0 X X D D X X X SO HIGH-IMPEDANCE 12. Other Commands and Functions 12.1 Reset In some applications, it may be necessary to prematurely terminate a program or erase cycle early rather than wait the hundreds of microseconds or milliseconds necessary for the program or erase operation to complete normally. The Reset command allows a program or erase operation in progress to be ended abruptly and returns the device to an idle state. Since the need to reset the device is immediate, the Write Enable command does not need to be issued prior to the Reset command being issued. Therefore, the Reset command operates independently of the state of the WEL bit in the Status Register. The Reset command can only be executed if the command has been enabled by setting the Reset Enabled (RSTE) bit in the Status Register to a logical “1”. If the Reset command has not been enabled (the RSTE bit is in the logical “0” state), then any attempts at executing the Reset command will be ignored. To perform a Reset, the CS pin must first be asserted and the opcode of F0h must be clocked into the device. No address bytes need to be clocked in, but a confirmation byte of D0h must be clocked into the device immediately after the opcode. Any additional data clocked into the device after the confirmation byte will be ignored. When the CS pin is deasserted, the program or erase operation currently in progress will be terminated within a time of tRST. Since the program or erase operation may not complete before the device is reset, the contents of the page being programmed or the block being erased cannot be guaranteed to be valid. The Reset command has no effect on the states of the Sector Protection Registers, the Sector Lockdown Registers, or the SPRL, RSTE, and SLE bits in the Status Register. The WEL, PS, and ES bits, however, will be reset back to their default states. If a Reset operation is performed while a sector is erase suspended, the suspend operation will abort, and the contents of the block being erased in the suspended sector will be left in an undefined state. If a Reset is performed while a sector is program suspended, the suspend operation will abort, and the contents of the page that was being programmed and subsequently suspended will be undefined. The remaining pages in the 64-Kbyte sector will retain their previous contents. The complete opcode and confirmation byte must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, no Reset operation will be performed. 40 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] Figure 12-1. Reset CS 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SCK OPCODE CONFIRMATION BYTE IN 0 0 0 1 MSB SI 1 MSB 1 1 1 0 1 0 1 0 0 0 0 SO HIGH-IMPEDANCE 12.2 Read Manufacturer and Device ID Identification information can be read from the device to enable systems to electronically query and identify the device while it is in system. The identification method and the command opcode comply with the JEDEC standard for “Manufacturer and Device ID Read Methodology for SPI Compatible Serial Interface Memory Devices”. The type of information that can be read from the device includes the JEDEC defined Manufacturer ID, the vendor specific Device ID, and the vendor specific Extended Device Information. The Read Manufacturer and Device ID command is limited to a maximum clock frequency of fCLK. Since not all Flash devices are capable of operating at very high clock frequencies, applications should be designed to read the identification information from the devices at a reasonably low clock frequency to ensure that all devices to be used in the application can be identified properly. Once the identification process is complete, the application can then increase the clock frequency to accommodate specific Flash devices that are capable of operating at the higher clock frequencies. To read the identification information, the CS pin must first be asserted and the opcode of 9Fh must be clocked into the device. After the opcode has been clocked in, the device will begin outputting the identification data on the SO pin during the subsequent clock cycles. The first byte that will be output will be the Manufacturer ID followed by two bytes of Device ID information. The fourth byte output will be the Extended Device Information (EDI) String Length, which will be 01h indicating that one byte of EDI data follows. After the one byte of EDI data is output, the SO pin will go into a high-impedance state; therefore, additional clock cycles will have no affect on the SO pin and no data will be output. As indicated in the JEDEC standard, reading the EDI String Length and any subsequent data is optional. Deasserting the CS pin will terminate the Manufacturer and Device ID read operation and put the SO pin into a high-impedance state. The CS pin can be deasserted at any time and does not require that a full byte of data be read. 41 8693A–DFLASH–8/10 Table 12-1. Manufacturer and Device ID Information Data Type Manufacturer ID Device ID (Part 1) Device ID (Part 2) [Optional to read] Extended Device Information (EDI) String Length [Optional to read] EDI Byte 1 Value 1Fh 48h 00h 01h 00h Byte No. 1 2 3 4 5 Table 12-2. Data Type Manufacturer ID Manufacturer and Device ID Details Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Hex Value 1Fh 0 0 Family Code 0 1 1 1 Density Code 48h 0 1 Sub Code 0 0 1 0 Product Variant 00h 0 0 0 0 0 0 0 0 0 0 1 1 Family Code: Density Code: 010 (AT25DF/26DFxxx series) 01000 (64-Mbit) Details JEDEC Code: 0001 1111 (1Fh for Atmel) JEDEC Assigned Code Device ID (Part 1) Device ID (Part 2) Sub Code: 000 (Standard series) Product Variant: 00000 (Standard version) Table 12-3. Byte Number 1 EDI Data Bit 7 Bit 6 RFU 0 0 0 0 0 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Hex Value 00h 0 0 0 Details RFU: Reserved for Future Use Device Revision: 00000 (Initial version) Device Revision Figure 12-2. Read Manufacturer and Device ID CS 0 6 7 8 14 15 16 22 23 24 30 31 32 38 39 40 46 SCK OPCODE SI 9Fh SO HIGH-IMPEDANCE 1Fh 86h 00h 01h 00h MANUFACTURER ID DEVICE ID BYTE 1 DEVICE ID BYTE 2 EDI STRING LENGTH EDI DATA BYTE 1 Note: Each transition shown for SI and SO represents one byte (8 bits) 42 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] 12.3 Deep Power-Down During normal operation, the device will be placed in the standby mode to consume less power as long as the CS pin remains deasserted and no internal operation is in progress. The Deep Power-Down command offers the ability to place the device into an even lower power consumption state called the Deep Power-Down mode. When the device is in the Deep Power-Down mode, all commands including the Read Status Register command will be ignored with the exception of the Resume from Deep Power-Down command. Since all commands will be ignored, the mode can be used as an extra protection mechanism against program and erase operations. Entering the Deep Power-Down mode is accomplished by simply asserting the CS pin, clocking in the opcode of B9h, and then deasserting the CS pin. Any additional data clocked into the device after the opcode will be ignored. When the CS pin is deasserted, the device will enter the Deep Power-Down mode within the maximum time of tEDPD. The complete opcode must be clocked in before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation and return to the standby mode once the CS pin is deasserted. In addition, the device will default to the standby mode after a power-cycle. The Deep Power-Down command will be ignored if an internally self-timed operation such as a program or erase cycle is in progress. The Deep Power-Down command must be reissued after the internally self-timed operation has been completed in order for the device to enter the Deep Power-Down mode. Figure 12-3. Deep Power-Down CS 0 1 2 3 4 5 6 7 tEDPD SCK OPCODE SI 1 MSB 0 1 1 1 0 0 1 SO HIGH-IMPEDANCE Active Current ICC Standby Mode Current Deep Power-Down Mode Current 43 8693A–DFLASH–8/10 12.4 Resume from Deep Power-Down In order to exit the Deep Power-Down mode and resume normal device operation, the Resume from Deep Power-Down command must be issued. The Resume from Deep Power-Down command is the only command that the device will recognized while in the Deep Power-Down mode. To resume from the Deep Power-Down mode, the CS pin must first be asserted and opcode of ABh must be clocked into the device. Any additional data clocked into the device after the opcode will be ignored. When the CS pin is deasserted, the device will exit the Deep PowerDown mode within the maximum time of tRDPD and return to the standby mode. After the device has returned to the standby mode, normal command operations such as Read Array can be resumed. If the complete opcode is not clocked in before the CS pin is deasserted, or if the CS pin is not deasserted on an even byte boundary (multiples of eight bits), then the device will abort the operation and return to the Deep Power-Down mode. Figure 12-4. Resume from Deep Power-Down CS 0 1 2 3 4 5 6 7 tRDPD SCK OPCODE SI 1 MSB 0 1 0 1 0 1 1 SO HIGH-IMPEDANCE Active Current ICC Deep Power-Down Mode Current Standby Mode Current 12.5 Hold The HOLD pin is used to pause the serial communication with the device without having to stop or reset the clock sequence. The Hold mode, however, does not have an affect on any internally self-timed operations such as a program or erase cycle. Therefore, if an erase cycle is in progress, asserting the HOLD pin will not pause the operation, and the erase cycle will continue until it is finished. The Hold mode can only be entered while the CS pin is asserted. The Hold mode is activated simply by asserting the HOLD pin during the SCK low pulse. If the HOLD pin is asserted during the SCK high pulse, then the Hold mode won’t be started until the beginning of the next SCK low pulse. The device will remain in the Hold mode as long as the H O L D pin and C S pin are asserted. While in the Hold mode, the SO pin will be in a high-impedance state. In addition, both the SI pin and the SCK pin will be ignored. The WP pin, however, can still be asserted or deasserted while in the Hold mode. 44 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] To end the Hold mode and resume serial communication, the HOLD pin must be deasserted during the SCK low pulse. If the HOLD pin is deasserted during the SCK high pulse, then the Hold mode won’t end until the beginning of the next SCK low pulse. If the CS pin is deasserted while the HOLD pin is still asserted, then any operation that may have been started will be aborted, and the device will reset the WEL bit in the Status Register back to the logical “0” state. Figure 12-5. Hold Mode CS SCK HOLD Hold Hold Hold 13. Atmel RapidS Implementation To implement Atmel® RapidS™ and operate at clock frequencies higher than what can be achieved in a viable SPI implementation, a full clock cycle can be used to transmit data back and forth across the serial bus. The Atmel AT25DF641A is designed to always clock its data out on the falling edge of the SCK signal and clock data in on the rising edge of SCK. For full clock cycle operation to be achieved, when the AT25DF641A is clocking data out on the falling edge of SCK, the host controller should wait until the next falling edge of SCK to latch the data in. Similarly, the host controller should clock its data out on the rising edge of SCK in order to give the AT25DF641A a full clock cycle to latch the incoming data in on the next rising edge of SCK. Implementing RapidS allows a system to run at higher clock frequencies since a full clock cycle is used to accommodate a device’s clock-to-output time, input setup time, and associated rise/fall times. For example, if the system clock frequency is 100MHz (10ns cycle time) with a 50% duty cycle, and the host controller has an input setup time of 2ns, then a standard SPI implementation would require that the slave device be capable of outputting its data in less than 3ns to meet the 2ns host controller setup time [(10ns x 50%) - 2ns] not accounting for rise/fall times. In an SPI mode 0 or 3 implementation, the SPI master is designed to clock in data on the next immediate rising edge of SCK after the SPI slave has clocked its data out on the preceding falling edge. This essentially makes SPI a half-clock cycle protocol and requires extremely fast clock-to-output times and input setup times in order to run at high clock frequencies. With a RapidS implementation of this example, however, the full 10ns cycle time is available which gives the slave device up to 8ns, not accounting for rise/fall times, to clock its data out. Likewise, with RapidS, the host controller has more time available to output its data to the slave since the slave device would be clocking that data in a full clock cycle later. 45 8693A–DFLASH–8/10 Figure 13-1. Atmel RapidS Operation Slave CS 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 SCK B A C MSB tV E D LSB MOSI BYTE A G F H I MISO MOSI = Master Out, Slave In MISO = Master In, Slave Out The Master is the ASIC/MCU and the Slave is the memory device. MSB LSB BYTE B The Master always clocks data out on the rising edge of SCK and always clocks data in on the falling edge of SCK. The Slave always clocks data out on the falling edge of SCK and always clocks data in on the rising edge of SCK. A. B. C. D. E. F. G. H. I. Master clocks out first bit of BYTE A on the rising edge of SCK Slave clocks in first bit of BYTE A on the next rising edge of SCK Master clocks out second bit of BYTE A on the same rising edge of SCK Last bit of BYTE A is clocked out from the Master Last bit of BYTE A is clocked into the slave Slave clocks out first bit of BYTE B Master clocks in first bit of BYTE B Slave clocks out second bit of BYTE B Master clocks in last bit of BYTE B 14. Electrical Specifications 14.1 Absolute Maximum Ratings* *NOTICE: Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. Functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Voltage extremes referenced in the “Absolute Maximum Ratings” are intended to accomodate short duration undershoot/overshoot conditions and does not imply or guarantee functional device operation at these levels for any extended period of time. Temperature under Bias .................... -55⋅C to +125⋅C Storage Temperature........................ -65°C to +150°C All Input Voltages (including NC Pins) with Respect to Ground ....................... -0.6V to +4.1V All Output Voltages with Respect to Ground ............... -0.6V to VCC + 0.5V 14.2 DC and AC Operating Range Atmel AT25DF641A Ind. -40°C to 85°C 2.7V to 3.6V Operating Temperature (Case) VCC Power Supply 46 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] 14.3 DC Characteristics Parameter Standby Current Condition CS, WP, HOLD = VCC, all inputs at CMOS levels CS, WP, HOLD = VCC, all inputs at CMOS levels f = 100MHz; IOUT = 0mA; CS = VIL, VCC = Max f = 85MHz; IOUT = 0mA; CS = VIL, VCC = Max f = 66MHz; IOUT = 0mA; CS = VIL, VCC = Max f = 50MHz; IOUT = 0mA; CS = VIL, VCC = Max f = 33MHz; IOUT = 0mA; CS = VIL, VCC = Max f = 20MHz; IOUT = 0mA; CS = VIL, VCC = Max ICC2 ICC3 ILI ILO VIL VIH VOL VOH Active Current, Program Operation Active Current, Erase Operation Input Leakage Current Output Leakage Current Input Low Voltage Input High Voltage Output Low Voltage Output High Voltage IOL = 1.6mA; VCC = Min IOH = -100µA; VCC = Min VCC - 0.2V 0.7 x VCC 0.4 CS = VCC, VCC = Max CS = VCC, VCC = Max VIN = CMOS levels VOUT = CMOS levels Min Typ 25 Max 50 Units µA Symbol ISB IDPD Deep Power-down Current 5 10 µA 12 19 10 17 8 14 mA ICC1 Active Current, Read Operation 7 12 6 10 5 12 12 8 18 18 1 1 0.3 x VCC mA mA µA µA V V V V 14.4 AC Characteristics - Maximum Clock Frequencies Parameter Min Max Units Symbol Atmel RapidS and SPI Operation fMAX fCLK fRDLF fRDDO Maximum Clock Frequency for All Operations – Atmel RapidS Operation Only (excluding 03h, 0Bh, 3Bh, and 9F opcodes) Maximum Clock Frequency for All Operations (excluding 03h opcode) Maximum Clock Frequency for 03h Opcode (Read Array – Low Frequency) Maximum Clock Frequency for 3Bh Opcode (Dual-Output Read) 100 85 50 85 MHz MHz MHz MHz 47 8693A–DFLASH–8/10 14.5 tCLKH tCLKL tCLKR(1) tCLKF(1) tCSH tCSLS tCSLH tCSHS tCSHH tDS tDH tDIS(1) tV(2) tOH tHLS tHLH tHHS tHHH tHLQZ(1) tHHQX(1) AC Characteristics – All Other Parameters Parameter Clock High Time Clock Low Time Clock Rise Time, Peak-to-Peak (Slew Rate) Clock Fall Time, Peak-to-Peak (Slew Rate) Chip Select High Time Chip Select Low Setup Time (relative to Clock) Chip Select Low Hold Time (relative to Clock) Chip Select High Setup Time (relative to Clock) Chip Select High Hold Time (relative to Clock) Data In Setup Time Data In Hold Time Output Disable Time Output Valid Time Output Hold Time HOLD Low Setup Time (relative to Clock) HOLD Low Hold Time (relative to Clock) HOLD High Setup Time (relative to Clock) HOLD High Hold Time (relative to Clock) HOLD Low to Output High-Z HOLD High to Output Low-Z Write Protect Setup Time Write Protect Hold Time Sector Protect Time (from Chip Select High) Sector Unprotect Time (from Chip Select High) Sector Lockdown and Freeze Sector Lockdown State Time (from Chip Select High) Chip Select High to Deep Power-Down Chip Select High to Standby Mode Reset Time 1. Not 100% tested (value guaranteed by design and characterization) 2. 15pF load at frequencies above 70MHz, 30pF otherwise 3. Only applicable as a constraint for the Write Status Register Byte 1 command when SPRL = 1 20 100 20 20 200 1 30 30 2 5 5 5 5 5 5 Min 4.3 4.3 0.1 0.1 50 5 5 5 5 2 1 5 5 Max Units ns ns V/ns V/ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns µs µs µs µs Symbol tWPS(1)(3) tWPH (1)(3) (1) tSECP tSECUP(1) tLOCK (1) tEDPD(1) tRDPD tRST Notes: (1) 48 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] 14.6 tPP(1) tBP tBLKE(1) tCHPE(1)(2) tSUSP Program and Erase Characteristics Parameter Page Program Time (256-Bytes) Byte Program Time 4-Kbytes Block Erase Time 32-Kbytes 64-Kbytes Chip Erase Time Program/Erase Suspend Time Program Erase Min Typ 1.0 7 75 300 500 55 10 25 10 12 200 200 600 950 100 20 µs 40 20 µs Erase 20 500 200 µs ns OTP Security Register Program Time Write Status Register Time 1. Maximum values indicate worst-case performance after 100,000 erase/program cycles 2. Not 100% tested (value guaranteed by design and characterization) Program/Erase Resume Time Program sec ms Max 3.0 Units ms µs Symbol tRES tOTPP(1) tWRSR(2) Note: 14.7 tVCSL tPUW VPOR Power-up Conditions Parameter Minimum VCC to Chip Select Low Time Power-up Device Delay Before Program or Erase Allowed Power-on Reset Voltage 1.5 Min 70 10 2.5 Max Units µs ms V Symbol 14.8 Input Test Waveforms and Measurement Levels AC DRIVING LEVELS 0.9VCC VCC/2 0.1VCC AC MEASUREMENT LEVEL tR, tF < 2 ns (10% to 90%) 14.9 Output Test Load DEVICE UNDER TEST 15pF (frequencies above 70MHz) or 30pF 49 8693A–DFLASH–8/10 15. AC Waveforms Figure 15-1. Serial Input Timing tCSH CS tCSLS tCLKH tCSLH tCLKL tCSHS tCSHH SCK tDS tDH MSB LSB MSB SI SO HIGH-IMPEDANCE Figure 15-2. Serial Output Timing CS tCLKH tCLKL tDIS SCK SI tV tOH tV SO Figure 15-3. WP Timing for Write Status Register Byte 1 Command When SPRL = 1 CS tWPS tWPH WP SCK SI 0 MSB OF WRITE STATUS REGISTER BYTE 1 OPCODE 0 0 X LSB OF WRITE STATUS REGISTER DATA BYTE MSB MSB OF NEXT OPCODE SO HIGH-IMPEDANCE 50 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] Figure 15-4. HOLD Timing – Serial Input CS SCK tHHH tHLS tHLH tHHS HOLD SI HIGH-IMPEDANCE SO Figure 15-5. HOLD Timing – Serial Output CS SCK tHHH tHLS tHLH tHHS HOLD SI tHLQZ tHHQX SO 51 8693A–DFLASH–8/10 16. Ordering Information 16.1 Ordering Code Detail AT25DF641A-SH-B Atmel Designator Shipping Carrier Option B = Bulk (tubes) Y = Bulk (trays) T = Tape and reel Product Family Device Grade Device Density 64 = 64-megabit H = Green, NiPdAu lead finish, industrial Temperature range (-40°C to +85°C) Interface 1 = Serial Package Option S = 8-lead, 0.208” wide SOIC M = 8-pad, 5 x 6 x 0.6mm (UDFN) Device Revision 16.2 Green Package Options (Pb/Halide-free/RoHS Compliant) Ordering Code Package 8S2 NiPdAu 2.7V to 3.6V 100 Industrial (-40°C to +85°C) 8MA1 Lead Finish Operating Voltage Max. Freq. (MHz) Operation Range AT25DF641A-SH-B AT25DF641A-SH-T AT25DF641A-MH-Y AT25DF641A-MH-T Note: The shipping carrier option code is not marked on the devices Package Type 8S2 8MA1 8-lead, 0.208” Wide, Plastic Gull Wing Small Outline Package (EIAJ SOIC) 8-pad 5 x 6 x 0.6mm Body, Thermally enhanced Plastic Ultra Thin Dual Flat No Lead Package (UDFN) 52 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] 17. Packaging Information 17.1 8S2 - EIAJ SOIC C 1 E E1 L N End View Top View e A A1 b q COMMON DIMENSIONS (Unit of Measure = mm) SYMBOL MIN NOM MAX NOTE A D 1.70 0.05 0.35 0.15 5.13 5.18 7.70 0.51 0˚ 1.27 BSC 2.16 0.25 0.48 0.35 5.35 5.40 8.26 0.85 8˚ 3 4/15/08 A1 b C D E1 E L q e Side View Notes: 1. This drawing is for general information only; refer to EIAJ Drawing EDR-7320 for additional information. 2. Mismatch of the upper and lower dies and resin burrs are not included. 3. Determines the true geometric position. 4. Values b, C apply to plated terminal. The standard thickness of the plating layer shall measure between 0.007 to .021mm. 4 4 2 TITLE GPC DRAWING NO. REV. 8S2, 8-lead, 0.208” Body, Plastic Small Package Drawing Contact: packagedrawings@atmel.com Outline Package (EIAJ) STN 8S2 F 53 8693A–DFLASH–8/10 17.2 8MA1 - UDFN E C Pin 1 ID Side View D y Top View A K 8 A1 E2 Option A Pin #1 Notch (0.20 R) (Option B) 1 Pin #1 Chamfer (C 0.35) 7 2 COMMON DIMENSIONS (Unit of Measure = mm) SYMBOL MIN NOM MAX NOTE D2 6 3 e A A1 b 0.45 0.00 0.35 4.90 3.80 5.90 3.20 0.50 0.00 0.20 0.55 0.02 0.40 0.152 REF 5.00 4.00 6.00 3.40 1.27 0.60 – – 0.60 0.05 0.48 5.10 4.20 6.10 3.60 0.75 0.08 – 4/15/08 5 4 C b L D D2 E E2 e L y K Bottom View Notes: 1. This package conforms to JEDEC reference MO-229, Saw Singulation. 2. The terminal #1 ID is a Laser-marked Feature. TITLE GPC DRAWING NO. REV. 8MA1, 8-pad (5 x 6 x 0.6mm Body), Thermally Package Drawing Contact: packagedrawings@atmel.com Enhanced Plastic Ultra Thin Dual Flat No Lead Package (UDFN) YFG 8MA1 D 54 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Atmel AT25DF641A [Preliminary] 18. Errata 18.1 Erase Suspend Issue: Parts may not program correctly if a device is in the Erase Suspend state. Workaround: None. It is recommended to not use the Byte/Page Program commands (opcodes 02h and A2h) during an Erase Suspend state. Systems should resume from Erase Suspend first before attempting to program a device. Resolution: The Erase Suspend feature is being fixed with a new revision of the device. Please contact Atmel for the estimated availability of devices with the fix. 18.2 AC Characteristics – Maximum Clock Frequencies for Read Operations Issue: Devices currently do not meet the maximum specified clock frequency for the following read operations: Read Array, Read Sector Protection Registers, Read Sector Lockdown Registers, Read OTP Security Register, Read Status Register, and Read Manufacturer and Device ID. Reading at clock frequencies higher than those listed below could cause read errors. Symbol fMAX fCLK fRDLF fRDDO Opcodes Affected 1Bh, 3Ch, 35h, 77h, 05h 0Bh, 9Fh 03h 3Bh Datasheet Specification 100MHz 85MHz 50MHz 85MHz Errata Specification 66MHz 66MHz 33MHz 66MHz Workaround: None. Devices are limited to the clock frequencies specified above. Resolution: The clock frequency issues are being fixed with a new revision of the device. Please contact Atmel® for the estimated availability of devices with the fix. 55 8693A–DFLASH–8/10 19. Revision History Doc. Rev. 8693A Date 08/2010 Comments Initial document release 56 Atmel AT25DF641A [Preliminary] 8693A–DFLASH–8/10 Headquarters Atmel Corporation 2325 Orchard Parkway San Jose, CA 95131 USA Tel: (+1) (408) 441-0311 Fax: (+1) (408) 487-2600 www.atmel.com International Atmel Asia Limited Unit 01-5 & 16, 19F BEA Tower, Millennium City 5 418 Kwun Tong Road Kwun Tong, Kowloon HONG KONG Tel: (+852) 2245-6100 Fax: (+852) 2722-1369 Atmel Munich GmbH Business Campus Parkring 4 D-85748 Garching b. Munich GERMANY Tel: (+49) 89-31970-0 Fax: (+49) 89-3194621 Atmel Japan 9F, Tonetsu Shinkawa Bldg. 1-24-8 Shinkawa Chuo-ku, Tokyo 104-0033 JAPAN Tel: (+81) (3) 3523-3551 Fax: (+81) (3) 3523-7581 Product Contact Technical Support dataflash@atmel.com Sales Contact www.atmel.com/contacts Literature Requests www.atmel.com/literature Disclaimer: The information in this document is provided in connection with Atmel products. No license, express or implied, by estoppel or otherwise, to any intellectual property right is granted by this document or in connection with the sale of Atmel products. EXCEPT AS SET FORTH IN ATMEL’S TERMS AND CONDITIONS OF SALE LOCATED ON ATMEL’S WEB SITE, ATMEL ASSUMES NO LIABILITY WHATSOEVER AND DISCLAIMS ANY EXPRESS, IMPLIED OR STATUTORY WARRANTY RELATING TO ITS PRODUCTS INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT. IN NO EVENT SHALL ATMEL BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL OR INCIDENTAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION, OR LOSS OF INFORMATION) ARISING OUT OF THE USE OR INABILITY TO USE THIS DOCUMENT, EVEN IF ATMEL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Atmel makes no representations or warranties with respect to the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications and product descriptions at any time without notice. Atmel does not make any commitment to update the information contained herein. Unless specifically provided otherwise, Atmel products are not suitable for, and shall not be used in, automotive applications. Atmel’s products are not intended, authorized, or warranted for use as components in applications intended to support or sustain life. © 2010 Atmel Corporation. All rights reserved. Atmel ®, Atmel logo and combinations thereof, DataFlash®, RapidS™ and others are registered trademarks or trademarks of Atmel Corporation or its subsidiaries. Other terms and product names may be trademarks of others. 8693A–DFLASH–8/10
AT25DF641A-SH-T 价格&库存

很抱歉,暂时无法提供与“AT25DF641A-SH-T”相匹配的价格&库存,您可以联系我们找货

免费人工找货