ATS-FM-22

ATS-FM-22

  • 厂商:

    ATS

  • 封装:

  • 描述:

    液体 PMIC - 栅极驱动器 1 ~ 15 LPM 公型,3/8",0.375"(9.525mm)BSP 共聚甲醛

  • 数据手册
  • 价格&库存
ATS-FM-22 数据手册
FLOW METER Flow Meter Instructional Manual 89-27 Access Road, Norwood, MA 02062 | T: 781.769. 2800 ats-hq@qats.com | www.qats.com R1_0718 Warranty Agreement Limited Warranty Advanced Thermal Solutions, Inc. (hereinafter “ATS”) warrants that: (1) the ATS Flow Meter family of products will perform in accordance with the written materials for a period of ninety (90) days from the date of purchase; and (2) Software will be free from defects and errors in materials and workmanship, and covered for a period of ninety (90) days from the date of purchase if utilized under normal use and service. Any implied warranties on the Software are limited to ninety (90) days. Copyright The ATS Flow Meter family and its operating software is a product of Advanced Thermal Solutions, Inc. Disclaimer While every effort is made to ensure accuracy, Advanced Thermal Solutions, Inc., cannot be held responsible for errors or omissions in this Manual. Furthermore, it reserves the right to revise this document and make changes without notice. 2 Table of Contents Contents Section 1: ATS-FM-M Flow Meter Features, Application, Electrical, Mechanical Drawing, Installation General, Operational Guide Section 2: ATS-FM-22 Flow Meter Features, Application, Electrical, Mechanical Drawing, Installation General, Operational Guide Section 3: ATS-FM-34 Flow Meter Features, Application, Electrical, Mechanical Drawing, Installation General, Operational Guide Section 4: ATS-FM-44 Flow Meter Features, Application, Electrical, Mechanical Drawing, Installation General, Operational Guide Section 5: ATS-FM-66 Flow Meter Features, Application, Electrical, Mechanical Drawing, Installation General, Operational Guide Section 6: ATS-FM-88 Flow Meter Features, Application, Electrical, Mechanical Drawing, Installation General, Operational Guide 3 4 6 8 10 12 14 Section 1: ATS-FM-M Flow Meter 1. Features Flow totaling up to 99,999 L Flow rate display from 0.8-8.0 L/min. Battery operated - two (2) AA batteries Low battery power alert Data retained even without battery power 2. Application Water cooler Water dispenser Machinery cooling systems AT S - F M - M 3. Electrical Operating Voltage: 3 DC Volts Operating Current: 1.0 mA (active), 0.015 mA (idle) 4. Mechanical Drawing 5. Installation Installation Method: Horizontal installation ONLY Flow Direction: One way Flow Rate: 0.8-8.0 L/min 4 6. General Temperature: 0 to 40°C (32 to 101°F) Pressure: Max. 6.0 bar (85 psi) Weight: 140 g (5.38 oz) Accuracy: +/- 10% Connection: 1/4" NPT male Materials Sensor Body: Acetal Copolymer, TICONA M90 Turbine: Acetal Copolymer, TICONA M90 Turbine Shaft: #304 Stainless Steel O-Ring: EPDM Rubber Housing: ABS resin 7. Operation Guide AT S - F M - M 7.1 Install Batteries Slide off the cover of the battery compartment and insert two (2) AA batteries. Then slide the cover back. 7.2 Connecting Fitting ATS-FM-M connectors are 1/4" NPT male. 7.3 Operating The ATS-FM-M will automatically turn on when there is water flowing through the sensor. It will automatically turn off after 10 seconds when there is no water flowing. 7.4 Display and Mode Selection Press the “DISPLAY” button to turn on the Flow Meter LCD screen. Press the “DISPLAY” button again to display the accumulated flow volume (flow totalization) or real-time flow rate. 7.5 Reset Press and hold the “RESET” button for four (4) seconds, to reset the total measured volume to zero (0). 7.6 Low Battery Power Alert When battery power is lower than normal working level, a buzzer will beep twice and the battery symbol on the screen will blink to notify users to change the battery. Once the batteries are replaced, the alert will be turned off. Data will be stored in memory and restored when the user replaces the batteries. 5 Section 2: ATS-FM-22 Flow Meter 1. Features Flow totaling up to 99,999 L Flow rate display from 1.0 to 15.0 L/min. Battery operated two (2) AA batteries Low battery power alert Data retained even without battery power AT S - F M - 2 2 2. Application Water cooler Water dispenser Machinery cooling systems 3. Electrical Operating Voltage: 3 DC Volts Operating Current: 1.0 mA (active), 0.015 mA (idle) 4. Mechanical Drawing 5. Installation Installation Method: Horizontal installation ONLY Flow Direction: One way Flow Rate: 1.0 – 15.0 L/min 6 6. General Temperature: 0 to 80°C (32 to 170°F) Pressure: Max. 6.0 bar (85 psi) Weight: 140 g (5.38 oz) Accuracy: +/- 10% Connection: 3/8" BSP male Materials Sensor Body: Acetal Copolymer, TICONA M90 Turbine: Acetal Copolymer, TICONA M90 Turbine Shaft: #304 Stainless Steel O-Ring: EPDM Rubber Housing: ABS resin AT S - F M - 2 2 7. Operation Guide 7.1 Install Batteries Slide off the cover of the battery compartment and insert two (2) AA batteries. Then slide the cover back. 7.2 Connecting Fitting ATS-FM-22 connectors are 3/8" BSP male. 7.3 Operating The ATS-FM-22 will automatically turn on when there is water flowing through the sensor. It will automatically turn off after 10 seconds when there is no water flowing. 7.4 Display and Mode Selection Press the “DISPLAY” button to turn on the Flow Meter LCD screen. Press the “DISPLAY” button again to display the accumulated flow volume (flow totalization) or real-time flow rate. 7.5 Reset Press and hold the “RESET” button for four (4) seconds, to reset the total measured volume to zero (0). 7.6 Low Battery Power Alert When battery power is lower than normal working level, a buzzer will beep twice and the battery symbol on the screen will blink to notify users to change the battery. Once the batteries are replaced, the alert will be turned off. Data will be stored in memory and restored when the user replaces the batteries. 7 Section 3: ATS-FM-34 Flow Meter 1. Features Flow totaling up to 99,999 L Flow rate display from 0.04 to 1.0 L/min. Battery operated two (2) AA batteries Low battery power alert Data retained even without battery power AT S - F M - 3 4 2. Applications Water cooler Water dispenser Machinery cooling systems 3. Electrical Operating Voltage: 3 DC Volts Operating Current: 1.0 mA (active), 0.015 mA (idle) 4. Mechanical Drawing 5. Installation Installation Method: Horizontal installation ONLY Flow Direction: One way Flow Rate: 0.04 – 1.0 L/min 8 6. General Temperature: 0 to 80°C (32 to 170°F) Pressure: Max. 6.0 bar (85 psi) Weight: 140 g (5.38 oz) Accuracy: +/- 10% Connection: 1/4" NPT male Materials Sensor Body: Acetal Copolymer, TICONA M90 Turbine: Acetal Copolymer, TICONA M90 Turbine Shaft: #304 Stainless Steel O-Ring: EPDM Rubber Housing: ABS resin AT S - F M - 3 4 7. Operation Guide 7.1 Install Batteries Slide off the cover of the battery compartment and insert two (2) AA batteries. Then slide the cover back. 7.2 Connecting Fitting ATS-FM-34 Flow Meter connectors are 1/4" NPT male. 7.3 Operating The ATS-FM-34 will automatically turn on when there is water flowing through the sensor. It will automatically turn off after 10 seconds when there is no water flowing. 7.4 Display and Mode Selection Press the “DISPLAY” button to turn on the Flow Meter LCD screen. Press the “DISPLAY” button again to display the accumulated flow volume (flow totalization) or real-time flow rate. 7.5 Reset Press and hold the “RESET” button for four (4) seconds, to reset the total measured volume to zero (0). 7.6 Low Battery Power Alert When battery power is lower than normal working level, a buzzer will beep twice and the battery symbol on the screen will blink to notify users to change the battery. Once the batteries are replaced, the alert will be turned off. Data will be stored in memory and restored when the user replaces the batteries. 9 AT S - F M - 4 4 Section 4: ATS-FM-44 Flow Meter 1. Features Flow totaling up to 99,999 L Flow rate display from 1.5 to 25.0 L/min. Battery operated - two (2) AA batteries Low battery power alert Data retained even without battery power 2. Application Water cooler Water dispenser Machinery cooling systems 3. Electrical Operating Voltage: 3 DC Volts Operating Current: 1.0 mA (active), 0.015 mA (idle) 4. Mechanical Drawing 5. Installation Mounting Method: Vertical, Horizontal or any angle installation for flow sensor Flowing Direction: One way Flow Rate : 1.5 – 25.0 L/min 10 AT S - F M - 4 4 6. General Temperature: 0 to 60°C (32 to 140°F) Pressure: Max. 6.0 bar (85 psi) Weight: 140 g (5.38 oz) Accuracy : +/- 5% Connection: 1/2" BSP Materials Sensor Body: Glass Filled PPS Turbine: PA composite Turbine holder Acetal Copolymer, TICONA M90 Turbine Shaft: Ceramic O-Ring: EPDM Rubber Control Unit Housing: ABS resin 7.0 Operation Guide 7.1 Install Batteries Slide off the cover of the battery compartment and insert two (2) AA batteries. Then slide the cover back. 7.2 Connecting Fitting ATS-FM-44 connectors are 1/2" BSP. 7.3 Operating The ATS-FM-44 will automatically turn on when there is water flowing through the sensor. It will automatically turn off after 10 seconds when there is no water flowing. 7.4 Display and Mode Selection Press the “DISPLAY” button to turn on the Flow Meter LCD screen. Press the “DISPLAY” button again to display the accumulated flow volume (flow totalization) or real-time flow rate. 7.5 Reset Press and hold the “RESET” button for four (4) seconds, to reset the total measured volume to zero (0). 7.6 Low Battery Power Alert When battery power is lower than normal working level, a buzzer will beep twice and the battery symbol on the screen will blink to notify users to change the battery. Once the batteries are replaced, the alert will be turned off. Data will be stored in memory and restored when the user replaces the batteries. 11 AT S - F M - 6 6 Section 5: ATS-FM-66 Flow Meter 1. Features Flow totaling up to 99,999 L Flow rate display from 2.4 – 60.0 L/min Battery operated - two (2) AA batteries Low battery power alert Data retained even without battery power 2. Application Water cooler Water dispenser Cooling system for machinery 3. Electrical Operating Voltage: 3 DC Volts Operating Current: 1.0 mA (work), 0.015 mA (sleep) 4. Mechanical Drawing Electrical Control Box Flow Sensor 5. Installation Installation Method: Vertical, Horizontal (any angles) Flow Direction: One way Flow Rate: 2.4 – 60 L/min 12 AT S - F M - 6 6 6. General Temperature: 0 to 80­°C (32 to 170°F) Pressure: Max. 6.0 bar (85 psi) Weight: 140 g (5.38 oz) Accuracy: +/- 10% Connection: 3/4" BSP male Materials Sensor Body: PA6, Nylon Turbine: Plastic, Magnet Turbine Shaft: #304 stainless steel (ceramic option available) Control Box Housing: ABS resin 7. Operation Guide 7.1 Install Batteries Slide off the cover of the battery compartment and insert two (2) AA batteries. Then slide the cover back. 7.2 Connecting Fitting ATS-FM-66 connectors are 3/4" BSP male.  7.3 Operating The ATS-FM-66 will automatically turn on when there is water flowing through the sensor. It will automatically turn off after 10 seconds when there is no water flowing. 7.4 Display and Mode Selection  Press the “DISPLAY” button to turn on the Flow Meter LCD screen. Press the “DISPLAY” button again to display the accumulated flow volume (flow totalization) or real-time flow rate. 7.5 Reset Press and hold the “RESET” button for four (4) seconds, to reset the total measured volume to zero (0).  7.6 Low Battery Power Alert When battery power is lower than normal working level, a buzzer will beep twice and the battery symbol on the screen will blink to notify users to change the battery. Once the batteries are replaced, the alert will be turned off. Data will be stored in memory and restored when the user replaces the batteries. 13 AT S - F M - 8 8 Section 6: ATS-FM-88 Flow Meter 1. Features Flow totaling up to 99,999 L Flow rate display from 3.0 – 100.0 L/min Battery operated - two (2) AA batteries Low battery power alert Data retained even without battery power 2. Application Water cooler Water dispenser Machinery cooling systems 3. Electrical Operating Voltage: 3 DC Volts Operating Current: 1.0 mA (active), 0.015 mA (idle) 4. Mechanical Drawing Electrical Control Box Flow Sensor 5. Installation Mounting Method: Vertical, Horizontal or any angle installation for flow sensor Flowing Direction: One way Flow Rate: 3.0-100.0 L/min 14 AT S - F M - 8 8 6. General Temperature: 0 to 80­°C (32 to 170°F) Pressure: Max. 8.0 bar (85 psi) Weight: 140 g (5.38 oz) Accuracy: +/- 10% Connection: 1" BSP male Materials Sensor Body: PA6, Nylon Turbine: Plastic, Magnet Turbine Shaft: #304 stainless steel (ceramic option available) Control Box Housing: ABS resin 7. Operation Guide 7.1 Install Batteries Slide off the cover of the battery compartment and insert two (2) AA batteries. Then slide the cover back. 7.2 Connecting Fitting ATS-FM-88 connectors are 1" BSP male.  7.3 Operating The ATS-FM-88 will automatically turn on when there is water flowing through the sensor. It will automatically turn off after 10 seconds when there is no water flowing. 7.4 Display and Mode Selection  Press the “DISPLAY” button to turn on the Flow Meter LCD screen. Press the “DISPLAY” button again to display the accumulated flow volume (flow totalization) or real-time flow rate. 7.5 Reset Press and hold the “RESET” button for four (4) seconds, to reset the total measured volume to zero (0).  7.6 Low Battery Power Alert When battery power is lower than normal working level, a buzzer will beep twice and the battery symbol on the screen will blink to notify users to change the battery. Once the batteries are replaced, the alert will be turned off. Data will be stored in memory and restored when the user replaces the batteries. 15 www.qats.com Advanced Thermal Solutions, Inc Advanced Thermal Solutions, Inc. (ATS) is a leading thermal engineering and manufacturing company supplying complete thermal and mechanical packaging solutions from analysis and testing to final production. ATS is world-renowned for its portfolio of more than 5,000 high-performance heat sinks, research-quality test equipment, complete liquid cooling loop products and leading-edge R&D, specifically tailored to the telecom, LED and computing industries. In addition, ATS provides thermal design consulting services and training for the electronics cooling industry. For further technical information, please contact Advanced Thermal Solutions, Inc. (ATS) by calling 781.769.2800, by emailing ats-hq@qats.com or by visiting www.qats.com. Advanced Thermal Solutions, Inc 89-27 Access Road, Norwood, MA 02062 phone: 718.769.2800
ATS-FM-22 价格&库存

很抱歉,暂时无法提供与“ATS-FM-22”相匹配的价格&库存,您可以联系我们找货

免费人工找货
ATS-FM-22
  •  国内价格 香港价格
  • 1+803.184311+99.63464
  • 5+631.248085+78.30604
  • 10+601.7218310+74.64332
  • 30+570.9474630+70.82577
  • 100+541.51106100+67.17420

库存:8