Semiconductor
SRM-356VF
Receiver Module
Features
• Photo detector and preamplifier in one package • Enhanced immunity against all kinds of disturbance light • High performance photo diode and built-in I.C • High speed response and output • Low power consumption and easy use • Light detecting portion of remote control • TVs, VCRs, Audio equipments, CATV Set Top boxes, Multi-media equipments
Application
Outline Dimensions
unit : mm
PIN Connections 1.Output 2.Vcc(+5V) 3.Gnd
KMM-1011-000
1
SRM-356VF
Absolute maximum ratings
Characteristic Supply Voltage Power Dissipation Operating Temperature Storage Temperature * Soldering Temperature
1
Symbol
VCC PD Topr Tstg Tsol
Ratings
6.0 0.27 -10 ~ 60 -20 ~ 75 260 ℃ within 5 seconds
Unit
V W ℃ ℃
*1.Keep the distance more than 2.0mm from PCB to the bottom of package
Electrical Characteristics
Parameter
Supply Voltage Current Consumption Resonance Frequency Peak sensitivity wavelength H level output voltage L level output voltage H level pules width L level pules width Arrival distance
(Ta=25°C)
Symbol
Vcc ICC fC λP VOH VOL Twh Twl
Test Condition
#1 -
Min.
4.5 0.3 4.5
Typ.
5.0 38 980 5.0 0.2 20 15 10
Max.
5.5 1.5 0.4 700 700 -
Unit
V mA KHz nm V V us us m
#2
500 500 ±0 ˚ -
L
#2,3,4
± 30 ˚ ± 45 ˚
Output form
Active low
KMM-1011-000
2
Characteristic Diagrams
Fig. 1 Relative Spectral Sensitivity - Wavelength
SRM-356VF
Fig. 2 drel-Relative Transmission Distance Directivity tsop
S(λ ) - Relative Spectral Sensitivity
Fig. 3 System Gain - Frequency
Supply Voltage Vcc[V]
Input Current [A]
Wavelength [nm]
drel-Relative Transmission Distance Directivity tsop
System Gain [dB]
Frequency [Hz]
KMM-1011-000
3
# 1. No input signal.
SRM-356VF
# 2. The burst wave forms shown below in the Fig 1. Shall be transmitted by the standard transmitter.
Transmitter Output Waveform
Receiver Module Output Waveform
Fig 1. Transmitter & Receiver wave forms
# 3. The test condition of arrival distance.
#4. The arrival distance is measured in the darkness without disturbing noises.
KMM-1011-000
4
SRM-356VF
Reliability Test
Test items
High temp & High humid Heat cycle Fall test
Test condition
Ta=40℃, RH=90%, t=96Hr’s #2, 3 #4
Remarks
#1, 2 -
#1. Supply voltage 5V at the load test. #2. Electro-optical characteristics shall be satisfied after 2hr’s at normal temperature. #3. Heat cycle test as below Fig2. For 20 cycles under no load.
Fig 2. Heat cycle test
#4. Fall test The test devices to fall three time onto hard wooden board from a level 75 ㎝
The others
In case of noisy power supply, please serially insert about 47Ω resistance an about 47 ㎌ electrolytic capacitance in line as follows.