Data Sheet
ACHS-719x
Fully Integrated, Hall-Effect Based Linear
Current Sensor IC with 3 kVRMS Isolation and a
Low-Resistance Current Conductor
Description
The Broadcom® ACHS-719x (±10A to ±50A) fully integrated
Hall-effect based isolated linear current sensors are
designed for AC or DC current sensing in industrial,
commercial, and communications systems. Inside each
ACHS-719x IC is a precise, low-offset, linear Hall circuit with
a copper conduction path located near the surface of the
die. Applied current flowing through this copper conduction
path generates a magnetic field that the differential Hall
sensors convert into a proportional voltage. Device
accuracy is optimized across the operating ambient
temperature through the close proximity of the magnetic
signal to the Hall sensors.
Features
A precise, proportional voltage is provided by the low-offset,
chopper-stabilized CMOS Hall IC, which is programmed for
accuracy after packaging. The output of the device has a
positive slope (>VOUT(Q)) when an increasing current flows
through the primary copper conduction path (from pins 1
and 2 to pins 3 and 4), which is the path used for current
sampling.
The internal resistance of this conductive path is 0.7 mΩ
typical, providing low power loss. The terminals of the
conductive path are electrically isolated from the signal
leads (pins 5 through 8).
This performance is delivered in a compact, surface
mountable, SO-8 package that meets worldwide regulatory
safety standards.
Wide operating temperature: –40ºC to +110ºC
Internal conductor resistance: 0.7 mΩ typ.
Sensing current range: ± 10A ~ ± 50A
Output sensitivity: 40 mV/A to 185 mV/A
Output voltage proportional to AC or DC currents
Ratiometric output from supply voltage
Single supply operation: 5.0V
Low-noise analog signal path
Device bandwidth is set via the new FILTER pin
– 80 kHz typ. bandwidth with 1-nF filter capacitor
Factory-trimmed for accuracy
Extremely stable output offset voltage
Near-zero magnetic hysteresis
Maximum output error of ±6.0% across operating TA
>25 kV/µs common mode transient immunity
Small footprint, low-profile SO-8 package
Worldwide safety approval: UL/cUL, IEC/EN 62368-1
– Isolation voltage: 3 kVrms, 1 minute
Applications
Low-power inverter current sensing
eBikes
Motor phase and rail current sensing
Solar inverters
Chargers and converters
Switching power supplies
CAUTION! Take normal static precautions in the handling and assembly of this component to prevent damage,
degradation, or both, which may be induced by ESD. The components featured in this data sheet are not to be
used in military or aerospace applications or environments.
Broadcom
ACHS-719x-DS102
October 9, 2019
Fully Integrated, Hall-Effect Based Linear Current Sensor IC with 3 kVRMS Isolation and a
Low-Resistance Current Conductor
ACHS-719x Data Sheet
Part Number
Current Range
Sensitivity
ACHS-7191
± 10A
185 mV/A
ACHS-7192
± 20A
100 mV/A
ACHS-7193
± 30A
66 mV/A
ACHS-7194
± 40A
50 mV/A
ACHS-7195
± 50Aa
40 mV/A
a. Due to the package dissipation power limitations, the input
power of ACHS-7195 must be derated at –25.2 mW/°C
above 85°C on a 4-oz copper PCB.
Functional Diagram
NOTE:
The connection of a 1-µF bypass capacitor between pins 8 and 5 is recommended.
Pin Description
Pin
Pin Name
1
IP+
2
IP+
3
IP-
4
IP-
Description
Pin
Pin Name
Description
Terminals for current being
sampled; fused internally
8
VDD
Supply voltage relative to GND
7
VOUT
Output voltage
Terminals for current being
sampled; fused internally
6
FILTER
5
GND
Filter pin to set bandwidth
Output side ground
Typical Application Circuit
A typical application circuit of each ACHS-719x will have a 1-µF bypass capacitor and a filter capacitor as additional external
components. The input side pin 1 and pin 2 are shorted together, and pin 3 and pin 4 are shorted together. The output voltage
is directly measured from the VOUT pin.
Broadcom
ACHS-719x-DS102
2
Fully Integrated, Hall-Effect Based Linear Current Sensor IC with 3 kVRMS Isolation and a
Low-Resistance Current Conductor
ACHS-719x Data Sheet
Ordering Information
Option
Part Number
ACHS-7191
ACHS-7192
ACHS-7193
ACHS-7194
ACHS-7195
Current
Rating
(RoHS)
Compliant
Package
Surface Mount
± 10A
-000E
SO-8
X
± 20A
± 30A
± 40A
± 50A
-500E
X
-000E
X
-500E
X
-000E
X
-500E
X
-000E
X
-500E
X
-000E
X
-500E
X
Tape & Reel
X
X
X
X
X
UL 3 kVRMS
1 min. Rating
Quantity
X
100 per tube
X
1500 per reel
X
100 per tube
X
1500 per reel
X
100 per tube
X
1500 per reel
X
100 per tube
X
1500 per reel
X
100 per tube
X
1500 per reel
To form an order entry, choose a part number from the Part Number column and combine with the desired option from the
Option column.
Example 1:
Select ACHS-7195-500E to order the product with ±50A, Surface Mount type in Tape-and-Reel packaging and RoHS
compliance. Contact your Broadcom sales representative or authorized distributor for information.
Option data sheets are available. Contact your Broadcom sales representative or authorized distributor for information.
Broadcom
ACHS-719x-DS102
3
Fully Integrated, Hall-Effect Based Linear Current Sensor IC with 3 kVRMS Isolation and a
Low-Resistance Current Conductor
ACHS-719x Data Sheet
Package Outline Drawing
ACHS-719x SO-8 Package
PART NUMBER
RoHS COMPLIANCE
INDICATOR
DATECODE
LOT ID
NOTE:
1. Dimensions are in millimeters (inches).
2. Lead coplanarity = 0.100 mm (0.004 in.) maximum.
3. Floating lead protrusion = 0.254 mm (0.010 in.) maximum.
4. Mold flash on each side = 0.127 mm (0.005 in.) maximum.
Recommended Pb-Free IR Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-halide flux should be used.
Broadcom
ACHS-719x-DS102
4
Fully Integrated, Hall-Effect Based Linear Current Sensor IC with 3 kVRMS Isolation and a
Low-Resistance Current Conductor
ACHS-719x Data Sheet
Regulatory Information
The ACHS-719x ICs are approved by the following organizations.
UL/cUL
UL 1577, component recognition program up to VISO = 3000 VRMS.
Approved under IEC/EN 62368-1; Certified under TUV Rheinland (former IEC 60950-1).
Insulation and Safety Related Specifications
Parameter
Symbol
Value
Units
Minimum External Air Gap
(External Clearance)
L(101)
4.0
mm
Measured from input terminals to output terminals,
shortest distance through air.
Minimum External Tracking
(External Creepage)
L(102)
4.0
mm
Measured from input terminals to output terminals,
shortest distance path along the body.
Minimum Internal Plastic Gap
(Internal Clearance)
—
0.05
mm
Through insulation distance, conductor to conductor,
usually the direct distance between the primary input
conductor and the detector IC.
Tracking Resistance
(Comparative Tracking Index)
CTI
>175
V
DIN IEC 112/VDE 0303 Part 1.
—
IIIa
—
Material Group (DIN VDE 0110, 1/89, Table 1).
Isolation Group
Conditions
Absolute Maximum Rating
Parameter
Symbol
Min.
Max.
Units
Storage Temperature
TS
–55
+125
°C
—
Ambient Operating Temperature
TA
–40
+110
°C
—
Junction Temperature
TJ(max)
—
+150
°C
—
Primary Conductor Lead Temperature
TL(MAX)
—
+150
°C
Pins 1, 2, 3, or 4
Supply Voltage
VDD
–0.5
8.0
V
—
Output Voltage
VOUT
–0.5
VDD + 0.5
V
—
IOUT(source)
—
10
mA
TA = 25°C
IOUT(sink)
—
10
mA
TA = 25°C
IP
—
100
A
PIN
—
1750
mW
—
POUT
—
90
mW
—
Output Current Source
Output Current Sink
Overcurrent Transient Tolerance
Input Power Dissipation
a
Output Power Dissipation
Test Conditions
1 pulse, 100 ms; TA = 25°C
a. Absolute maximum input power dissipation is only valid if a 4-oz copper PCB is used. This power is valid up to 85°C ambient temperature.
For >85°C ambient, a derating factor of –25.2 mW/°C is required.
Broadcom
ACHS-719x-DS102
5
Fully Integrated, Hall-Effect Based Linear Current Sensor IC with 3 kVRMS Isolation and a
Low-Resistance Current Conductor
ACHS-719x Data Sheet
Recommended Operating Conditions
Parameter
Symbol
Min.
Max.
Units
TA
–40
+110
°C
VDD
4.5
5.5
V
Output Capacitance Load
CLOAD
—
10
nF
Output Resistive Load
RLOAD
4.7
—
kΩ
IP
–10
+10
A
ACHS-7192
–20
+20
A
ACHS-7193
–30
+30
A
ACHS-7194
–40
+40
A
ACHS-7195a
–50
+50
A
Ambient Operating Temperature
VDD Supply Voltage
Input Current Range
ACHS-7191
a. Due to the SO-8 package power dissipation limitations, the input peak current is valid up to 85°C ambient temperature only on a 4-oz copper
PCB. For >85°C ambient, derating is required. For details, see footnote a at Absolute Maximum Rating. For the input power derating curve,
see Primary Power Derating Curve for ACHS-7195.
Primary Power Derating Curve for ACHS-7195
2
1.8
Pin(W)
1.75W
1.6
Maximum Primary Power
1.4
1.2
1.12W
1
0.8
0.6
0.4
0.2
TA (°C)
0
-40
NOTE:
Broadcom
-20
0
20
40
60
KƉĞƌĂƟng Ambient Temperature
80
85
100
110
Mounted on Broadcom’s evaluation board as shown in Figure 16 and Figure 17.
ACHS-719x-DS102
6
Fully Integrated, Hall-Effect Based Linear Current Sensor IC with 3 kVRMS Isolation and a
Low-Resistance Current Conductor
ACHS-719x Data Sheet
Common Electrical Specifications
Unless otherwise noted, all minimum/maximum specifications are over-recommended operating conditions, CF = 1 nF.
Typical values are at TA = +25°C, VDD = 5.0V, CF = 1 nF.
Parameter
Symbol
Min.
Typ.
Max.
Units
IDD
—
13
15
mA
VDD = 5V, output open
RPRIMARY
—
0.7
—
mΩ
Zero Current Output Voltage
VOUT(Q)
—
VDD / 2
—
Input Filter Resistance
RF(INT)
—
1.6
Bandwidth
BW
—
Rise Time
tr
—
tPO
CMTI
Supply Current
Primary Conductance Resistance
Power-on Time
Common Mode Transient Immunity
Test Condition
Figure
Note
5, 6
—
—
—
—
V
Bidirectional, IP = 0A
2
—
—
kΩ
—
—
—
80
—
kHz
–3 dB
—
—
4
—
µs
—
10
—
—
21
—
µs
—
8
—
25
—
—
—
a
kV/µs VCM = 1000V
a. Common Mode Transient Immunity is tested by applying a fast rising/falling voltage pulse across pin 4 and GND (pin 5). The output glitch
observed is less than 0.2V from the average output voltage for less than 1 µs.
Electrical Specifications
For ACHS-7191: Unless otherwise noted, all minimum and maximum specifications are over-recommended operating
conditions, CF = 1 nF. Typical values are at TA = +25°C, VDD = 5.0V, CF = 1 nF.
Parameter
Symbol
Min.
Typ.
Max.
Units
IP
–10
—
+10
A
Sensitivity
Sens
—
185
—
Sensitivity Error
ESENS
–5
±3
+5
Sensitivity Slope
Sens
—
0.04
—
—
0.01
—
VOE
–30
—
+30
VOE
—
0.03
—
Optimized Accuracy Range
Zero Current Output Error
Zero Current Output Error Slope
Test Conditions
Figure
Note
7
a
1
b
1
b
mV/A/°C TA = –40°C to 25°C
1
b
TA = 25°C to 110°C
1
b
TA = 25°C
2
b
—
mV/°C TA = –40°C to 25°C
2
b
0.06
—
TA = 25°C to 110°C
2
b
—
mV/A –10A ≤ IP ≤ +10A
%
mV
TA = –40°C to 110°C,
VDD = 5V
Output Noise
VN(RMS)
—
7.8
—
mV
BW = 2 kHz
9
c
Nonlinearity
NL
—
0.27
—
%
—
3
d
ETOT
–6
±1.5
+6
%
TA = –40°C to 110°C
4
e
Sensitivity Error Lifetime Drift
ESENS_DRIFT
—
±2
—
%
—
—
—
Total Output Error Lifetime Drift
ETOT_DRIFT
—
±2
—
%
—
—
—
Total Output Error
a. The device may be operated at higher primary current levels, IP, provided that the Maximum Junction Temperature, TJ(MAX), is not exceeded.
b. See Definition of Electrical Characteristics.
c. Output Noise is the noise level of ACHS-7191 expressed in root mean square (RMS) voltage.
d. Nonlinearity is defined as half of the peak-to-peak output deviation from the best-fit line, expressed as a percentage of the full-scale output
voltage. See Definition of Electrical Characteristics for the complete definition and formula.
e. Total Output Error in percentage is the difference between the measured output voltage at maximum input current (IPMAX) and the ideal output
voltage at IPMAX divided by the ideal output voltage at IPMAX. The Total Output Error's typical value is based on the total output error measured
at the point of product release.
Broadcom
ACHS-719x-DS102
7
Fully Integrated, Hall-Effect Based Linear Current Sensor IC with 3 kVRMS Isolation and a
Low-Resistance Current Conductor
ACHS-719x Data Sheet
For ACHS-7192: Unless otherwise noted, all minimum/maximum specifications are over-recommended operating
conditions, CF = 1 nF. Typical values are at TA = +25°C, VDD = 5.0V, CF = 1 nF.
Parameter
Symbol
Min.
Typ.
Max.
Units
IP
–20
—
+20
A
Sensitivity
Sens
—
100
—
Sensitivity Error
ESENS
–4.5
±3
+4.5
Sensitivity Slope
Sens
—
0.01
—
—
0.01
—
%
VOE
–25
—
+25
mV
VOE
—
–0.01
—
Optimized Accuracy Range
Zero Current Output Error
Zero Current Output Error Slope
Test Conditions
Figure
Note
7
a
1
b
1
b
1
b
TA = 25°C to 110°C
1
b
TA = 25°C
2
b
—
mV/°C TA = –40°C to 25°C
2
b
0.02
—
mV/°C TA = 25°C to 110°C
2
b
—
mV/A –20A ≤ IP ≤ +20A
%
TA = –40°C to 110°C,
VDD = 5V
mV/A/°C TA = –40°C to 25°C
Output Noise
VN(RMS)
—
4.1
—
mV
BW = 2 kHz
9
c
Nonlinearity
NL
—
0.18
—
%
—
3
d
ETOT
–5.5
±1.5
+5.5
%
TA = –40°C to 110°C
4
e
Sensitivity Error Lifetime Drift
ESENS_DRIFT
—
±2
—
%
—
—
—
Total Output Error Lifetime Drift
ETOT_DRIFT
—
±2
—
%
—
—
—
Total Output Error
a. The device may be operated at higher primary current levels, IP, provided that the Maximum Junction Temperature, TJ(MAX), is not exceeded.
b. See Definition of Electrical Characteristics.
c. Output Noise is the noise level of ACHS-7192 expressed in root mean square (RMS) voltage.
d. Nonlinearity is defined as half of the peak-to-peak output deviation from the best-fit line, expressed as a percentage of the full-scale output
voltage. See Definition of Electrical Characteristics for the complete definition and formula.
e. Total Output Error in percentage is the difference between the measured output voltage at maximum input current (IPMAX) and the ideal output
voltage at IPMAX divided by the ideal output voltage at IPMAX. The Total Output Error's typical value is based on the total output error measured
at the point of product release.
Broadcom
ACHS-719x-DS102
8
Fully Integrated, Hall-Effect Based Linear Current Sensor IC with 3 kVRMS Isolation and a
Low-Resistance Current Conductor
ACHS-719x Data Sheet
For ACHS-7193: Unless otherwise noted, all minimum/maximum specifications are over-recommended operating
conditions, CF = 1 nF. Typical values are at TA = +25°C, VDD = 5.0V, CF = 1 nF.
Parameter
Symbol
Min.
Typ.
Max.
Units
IP
–30
—
+30
A
Sensitivity
Sens
—
66
—
Sensitivity Error
ESENS
–4.5
±3
+4.5
Sensitivity Slope
Sens
—
0.01
—
—
0.01
—
%
VOE
–20
—
+20
mV
VOE
—
0.01
—
Optimized Accuracy Range
Zero Current Output Error
Zero Current Output Error Slope
Test Conditions
Figure
Note
7
a
1
b
1
b
1
b
TA = 25°C to 110°C
1
b
TA = 25°C
2
b
—
mV/°C TA = –40°C to 25°C
2
b
0.02
—
mV/°C TA = 25°C to 110°C
2
b
—
mV/A –30A ≤ IP ≤ +30A
%
TA = –40°C to 110°C,
VDD = 5V
mV/A/°C TA = –40°C to 25°C
Output Noise
VN(RMS)
—
2.7
—
mV
BW = 2 kHz
9
c
Nonlinearity
NL
—
0.11
—
%
—
3
d
ETOT
–5.5
±1.5
+5.5
%
TA = –40°C to 110°C
4
e
Sensitivity Error Lifetime Drift
ESENS_DRIFT
—
±2
—
%
—
—
—
Total Output Error Lifetime Drift
ETOT_DRIFT
—
±2
—
%
—
—
—
Total Output Error
a. The device may be operated at higher primary current levels, IP, provided that the Maximum Junction Temperature, TJ(MAX), is not exceeded.
b. See Definition of Electrical Characteristics.
c. Output Noise is the noise level of ACHS-7193 expressed in root mean square (RMS) voltage.
d. Nonlinearity is defined as half of the peak-to-peak output deviation from the best-fit line, expressed as a percentage of the full-scale output
voltage. See Definition of Electrical Characteristics for the complete definition and formula.
e. Total Output Error in percentage is the difference between the measured output voltage at maximum input current (IPMAX) and the ideal output
voltage at IPMAX divided by the ideal output voltage at IPMAX. The Total Output Error's typical value is based on the total output error measured
at the point of product release.
Broadcom
ACHS-719x-DS102
9
Fully Integrated, Hall-Effect Based Linear Current Sensor IC with 3 kVRMS Isolation and a
Low-Resistance Current Conductor
ACHS-719x Data Sheet
For ACHS-7194: Unless otherwise noted, all minimum/maximum specifications are over-recommended operating
conditions, CF = 1 nF. Typical values are at TA = +25°C, VDD = 5.0V, CF = 1 nF.
Parameter
Symbol
Min.
Typ.
Max.
Units
IP
–40
—
+40
A
Sensitivity
Sens
—
50
—
Sensitivity Error
ESENS
–4.5
±3
+4.5
Sensitivity Slope
Sens
—
0.01
—
—
0.01
—
%
VOE
–20
—
+20
mV
VOE
—
–0.01
—
Optimized Accuracy Range
Zero Current Output Error
Zero Current Output Error Slope
Test Conditions
Figure
Note
7
a
1
b
1
b
1
b
TA = 25°C to 110°C
1
b
TA = 25°C
2
b
—
mV/°C TA = –40°C to 25°C
2
b
0.02
—
mV/°C TA = 25°C to 110°C
2
b
—
mV/A –40A ≤ IP ≤ 40A
%
TA = –40°C to 110°C,
VDD = 5V
mV/A/°C TA = –40°C to 25°C
Output Noise
VN(RMS)
—
2
—
mV
BW = 2 kHz
9
c
Nonlinearity
NL
—
0.1
—
%
—
3
d
ETOT
–5.5
±1.5
+5.5
%
TA = –40°C to 110°C
4
e
Sensitivity Error Lifetime Drift
ESENS_DRIFT
—
±2
—
%
—
—
—
Total Output Error Lifetime Drift
ETOT_DRIFT
—
±2
—
%
—
—
—
Total Output Error
a. The device may be operated at higher primary current levels, IP, provided that the Maximum Junction Temperature, (TJ(MAX), is not exceeded.
b. See Definition of Electrical Characteristics.
c. Output Noise is the noise level of ACHS-7194 expressed in root mean square (RMS) voltage.
d. Nonlinearity is defined as half of the peak-to-peak output deviation from the best-fit line, expressed as a percentage of the full-scale output
voltage. See Definition of Electrical Characteristics for the complete definition and formula.
e. Total Output Error in percentage is the difference between the measured output voltage at maximum input current (IPMAX) and the ideal output
voltage at IPMAX divided by the ideal output voltage at IPMAX. The Total Output Error's typical value is based on the total output error measured
at the point of product release.
Broadcom
ACHS-719x-DS102
10
Fully Integrated, Hall-Effect Based Linear Current Sensor IC with 3 kVRMS Isolation and a
Low-Resistance Current Conductor
ACHS-719x Data Sheet
For ACHS-7195: Unless otherwise noted, all minimum/maximum specifications are over-recommended operating
conditions, CF = 1 nF. Typical values are at TA = +25°C, VDD = 5.0V, CF = 1 nF.
Parameter
Symbol
Min.
Typ.
Max.
Units
IP
–50
—
+50
A
Sensitivity
Sens
—
40
—
Sensitivity Error
ESENS
–4.5
±3
+4.5
Sensitivity Slope
Sens
—
+0.01
—
—
0
—
%
VOE
–30
—
+30
mV
VOE
—
–0.01
—
Optimized Accuracy Rangea
Zero Current Output Error
Zero Current Output Error Slope
Test Conditions
Figure
Note
7
b
1
c
1
c
1
c
TA = 25°C to 110°C
1
c
TA = 25°C
2
c
—
mV/°C TA = –40°C to 25°C
2
c
0.01
—
mV/°C TA = 25°C to 110°C
2
c
—
mV/A –50A ≤ IP ≤ 50A
%
TA = –40°C to 110°C,
VDD = 5V
mV/A/°C TA = –40°C to 25°C
Output Noise
VN(RMS)
—
1.7
—
mV
BW = 2 kHz
9
d
Nonlinearity
NL
—
0.08
—
%
—
3
e
ETOT
–5.5
±1.5
+5.5
%
TA = –40°C to 110°C
4
f
Sensitivity Error Lifetime Drift
ESENS_DRIFT
—
±2
—
%
—
—
—
Total Output Error Lifetime Drift
ETOT_DRIFT
—
±2
—
%
—
—
—
Total Output Error
a. Due to the SO-8 package power dissipation limitations, the input RMS or DC current of the 50A product must be derated above 85°C ambient
at –25.2 mW/°C on a 4-oz copper PCB.
b. The device may be operated at higher primary current levels, IP, provided that the Maximum Junction Temperature, TJ(MAX), is not exceeded.
c. See Definition of Electrical Characteristics.
d. Output Noise is the noise level of ACHS-7195 expressed in root mean square (RMS) voltage.
e. Nonlinearity is defined as half of the peak-to-peak output deviation from the best-fit line, expressed as a percentage of the full-scale output
voltage. See Definition of Electrical Characteristics for the complete definition and formula.
f. Total Output Error in percentage is the difference between the measured output voltage at maximum input current (IPMAX) and the ideal output
voltage at IPMAX divided by the ideal output voltage at IPMAX. The Total Output Error's typical value is based on the total output error measured
at the point of product release.
Package Characteristics
Parameter
Symbol
Min.
Typ.
Max.
Units
Test Condition
Input-Output Momentary Withstand Voltage
VISO
3000
—
—
Resistance (Input-Output)
RI-O
—
1014
—
Ω
VI-O = 500 VDC
c
Capacitance (Input-Output)
CI-O
—
1.3
—
pF
f = 1 MHz
c
Junction-to-Ambient Thermal Resistance (Due to
Primary Conductor)
Rθ12
—
35
—
°C/W
Based on the Broadcom
evaluation board
d
Junction-to-Ambient Thermal Resistance (Due to IC)
Rθ22
—
22
—
°C/W
Based on the Broadcom
evaluation board
d
VRMS RH < 50%,
t = 1 minute,
TA = 25°C
Note
a, b, c
a. In accordance with UL 1577, each device is proof-tested by applying an insulation test voltage ≤ 3600 VRMS for 1 second.
b. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating.
c. This is a two-terminal measurement: pins 1 through 4 are shorted together, and pins 5 through 8 are shorted together.
d. The Broadcom evaluation board has 650 mm2 (total area including the top and bottom copper minus the mounting holes) of 4-oz copper
connected to pins 1 and 2 and pins 3 and 4. See Thermal Consideration for additional information on thermal characterization.
Broadcom
ACHS-719x-DS102
11
Fully Integrated, Hall-Effect Based Linear Current Sensor IC with 3 kVRMS Isolation and a
Low-Resistance Current Conductor
ACHS-719x Data Sheet
Typical Performance Plots
All typical plots are based on TA = 25°C, VDD = 5V, CF = 1 nF, unless otherwise stated.
Figure 1: Sensitivity vs. Temperature
Figure 2: Zero Current Output Voltage vs. Temperature
2.515
Zero Current Output Voltage VOUT(Q) - V
200
SensiƟvity (Sens) - mV/A
180
ACHS-7191
ACHS-7192
ACHS-7193
ACHS-7194
ACHS-7195
160
140
120
100
80
60
40
2.505
2.500
2.495
2.490
2.485
20
-40
-20
0
20
40
60
Temperature (TA) -
80
100
0.30
0.28
0.26
0.24
0.22
0.20
0.18
0.16
0.14
0.12
0.10
0.08
0.06
0.04
0.02
0.00
-40
120
-20
0
20
40
60
80
100
120
Temperature (TA) - oC
oC
Figure 3: Nonlinearity vs. Temperature
Figure 4: Total Output Error @ IP(MAX) vs. Temperature
6
ACHS-7191
ACHS-7192
ACHS-7193
ACHS-7194
ACHS-7195
4
ACHS-7191
ACHS-7192
ACHS-7193
ACHS-7194
ACHS-7195
Total Output Error - %
Nonlinearity (NL) - %
ACHS-7191
ACHS-7192
ACHS-7193
ACHS-7194
ACHS-7195
2.510
2
0
-2
-4
-6
-40
-20
0
20
40
60
Temperature (TA) - oC
Broadcom
80
100
120
-40
-20
0
20
40
60
80
100
120
Temperature (TA) - oC
ACHS-719x-DS102
12
Fully Integrated, Hall-Effect Based Linear Current Sensor IC with 3 kVRMS Isolation and a
Low-Resistance Current Conductor
ACHS-719x Data Sheet
Figure 5: Supply Current vs. Temperature
Figure 6: Supply Current vs. Supply Voltage
Figure 7: Output Voltage vs. Sensed Current
Figure 8: Power-On Time vs. External Filter
5.0
Output Voltage (VOUT) - V
4.5
4.0
3.5
3.0
2.5
2.0
ACHS-7191
ACHS-7192
ACHS-7193
ACHS-7194
ACHS-7195
1.5
1.0
0.5
0.0
-50
-40
-30
-20
-10
0
10
20
30
40
50
Input Current (Ip), A
Figure 9: Noise vs. External Filter
Figure 10: Rise Time vs. External Filter
Output Noise (VNRMS) - mV
10
1
ACHS-7191
ACHS-7192
ACHS-7193
ACHS-7194
ACHS-7195
0.1
0.01
0.1
1
10
100
External Filter Capacitance (CF) - nF
Broadcom
ACHS-719x-DS102
13
ACHS-719x Data Sheet
Definition of Electrical
Characteristics
Fully Integrated, Hall-Effect Based Linear Current Sensor IC with 3 kVRMS Isolation and a
Low-Resistance Current Conductor
Figure 11: Nonlinearity Calculation
The ACHS-719x product series is a Hall-effect current
sensor that sends an analog voltage proportional to the
magnetic field intensity caused by the current flowing
through the input primary conductor. Without a magnetic
field, the output voltage is half of the supply voltage. It can
detect both DC and AC current.
Ratiometric Output
The output voltage of the ACHS-719x series is ratiometric or
proportional to the supply voltage. The sensitivity (Sens) of
the device and the quiescent output voltage change when
there is a change in the supply voltage (VDD). For example,
for ACHS-7195 when the VDD is increased by +10% from 5V
to 5.5V, the quiescent output voltage will change from 2.5V
to 2.75V and the sensitivity will also change from 40 mV/A
to 44 mV/A.
Sensitivity
The output sensitivity (Sens) is the ratio of the output
voltage (VOUT) over the input current (IP) flowing through the
primary conductor. It is expressed in mV/A. When an
applied current flows through the input primary conductor, it
generates a magnetic field that the Hall IC converts into a
voltage. The proportional voltage is provided by the Hall IC,
which is programmed at the factory for accuracy after
packaging. The output voltage has a positive slope when an
increasing current flows through pins 1 and 2 to pins 3 and
4. Sensitivity Error (ESENS) is the difference between the
measured sensitivity and the ideal sensitivity expressed in
percentage (%).
Nonlinearity
Nonlinearity is defined as half of the peak-to-peak output
deviation from the best-fit line (BFL), expressed as a
percentage of the full-scale output voltage. The full-scale
output voltage is the product of the sensitivity (Sens) and full
scale input current (IP).
NL (%) = [(Max ' from BFL ± 0LQ'from BFL) / 2] × 100%
Sens × )ull 6cale IP
Broadcom
Zero Current Output Voltage
This is the output voltage of ACHS-719x when the primary
current is zero. Zero current output voltage is half of the
supply voltage (VDD/2).
Zero Current Output Error
This the voltage difference between the measured output
voltage and the ideal output voltage (VDD/2) when there is
no input current to the device.
Total Output Error
Total output error in percentage is the difference between
the measured output voltage at maximum input current
(IPMAX) and the ideal output voltage at IPMAX divided by the
ideal output voltage at IPMAX.
ETOT(%) =Measured VOUT @ IPMAX – Ideal VOUT@IPMAX × 100%
Ideal VOUT@ IPMAX
Power-On Time
This is the time required for the internal circuitry of the
device to be ready during the ramping of the supply voltage.
Power-on time is defined as the finite time required for the
output voltage to settle after the supply voltage reaches its
recommended operating voltage.
FILTER Pin
The ACHS-719x has a FILTER pin for improving the signalto-noise ratio of the device. This eliminates the need for an
external RC filter to the VOUT pin of the device, which can
cause attenuation of the output signal. A ceramic capacitor,
CF, can be connected between the FILTER pin to GND.
ACHS-719x-DS102
14
ACHS-719x Data Sheet
Application Information
Fully Integrated, Hall-Effect Based Linear Current Sensor IC with 3 kVRMS Isolation and a
Low-Resistance Current Conductor
Figure 13: Recommended Trace Layout on the Input Pins
PCB Layout
The design of the printed circuit board (PCB) should follow
good layout practices, such as keeping bypass capacitors
close to the supply pin and the use of ground and power
planes. A bypass capacitor must be connected between
pins 5 and 8 of the device. The layout of the PCB can also
affect the common mode transient immunity of the device
due to stray capacitive coupling between the input and
output circuits. To obtain maximum common mode transient
immunity performance, the layout of the PCB should
minimize any stray coupling by maintaining the maximum
possible distance between the input and output sides of the
circuit and ensuring that any ground or power plane on the
PCB does not pass directly below or extend much wider
than the body of the device.
When the connection to the input pin covers only the vertical
portion of the input pin, there is a sensitivity variation of
about –0.6% versus the recommended PCB trace layout as
shown in Figure 14.
Figure 14: Vertical Portion Connection
Land Pattern for 4-mm Board Creepage
For applications that require PCB creepage of 4 mm
between input and output sides, the land pattern in
Figure 12 can be used.
Figure 12: Land Pattern for 4-mm Creepage
When the connection to the input pin covers only the
horizontal portion of the input pin, there is a sensitivity
variation of about +1.2% versus the recommended PCB
trace layout (as shown in Figure 15).
Figure 15: Horizontal Portion Connection
Effect of PCB Layout on Sensitivity
The trace layout on the input pins of ACHS-719x affects the
sensitivity. Ensure that the PCB trace connection to the
input pins covers the pins fully as shown in Figure 13.
Broadcom
ACHS-719x-DS102
15
ACHS-719x Data Sheet
Thermal Consideration
The evaluation board used in the thermal characterization is
shown in Figure 16 and Figure 17. The inputs IP+ and IPare each connected to the input plane of 4-oz copper with at
least 650 mm2 of total area (including top and bottom
planes, minus the screw mounting holes). The output side
GND is connected to a ground plane of 4-oz copper with
460 mm2 of total area (including top and bottom planes).
The 4-oz copper enables the board to conduct higher
current and achieve good thermal distribution in a limited
space.
Broadcom
Fully Integrated, Hall-Effect Based Linear Current Sensor IC with 3 kVRMS Isolation and a
Low-Resistance Current Conductor
Figure 16: Broadcom Evaluation Board – Top Layer
Figure 17: Broadcom Evaluation Board – Bottom Layer
ACHS-719x-DS102
16
Broadcom, the pulse logo, Connecting everything, Avago Technologies, Avago, and the A logo are among the trademarks
of Broadcom and/or its affiliates in the United States, certain other countries, and/or the EU.
Copyright © 2019 Broadcom. All Rights Reserved.
The term “Broadcom” refers to Broadcom Inc. and/or its subsidiaries. For more information, please visit www.broadcom.com.
Broadcom reserves the right to make changes without further notice to any products or data herein to improve reliability,
function, or design. Information furnished by Broadcom is believed to be accurate and reliable. However, Broadcom does
not assume any liability arising out of the application or use of this information, nor the application or use of any product or
circuit described herein, neither does it convey any license under its patent rights nor the rights of others.