Data Sheet
ACNT-H511/H511C
Open-Collector Output Optocoupler in 15-mm
Stretched SO8 Package
Overview
Features
The ACNT-H511/H511C is a single-channel open-collector
output optocoupler in Stretched SO8 footprint. The
ACNT-H511C is a high CTI optocoupler that can meet a
wider range of creepage values for a higher working voltage
or rated insulation voltage. With high CTI, material group
upgrade to I, the overall creepage requirements will reduce
by half.
The ACNT-H511/H511C uses an insulating layer between
the light emitting diode and an integrated photon detector to
provide electrical insulation between input and output.
Separate connections for the photodiode bias and output
transistor collector increase the speed up to a hundred
times over that of a conventional photo-transistor coupler by
reducing the base-collector capacitance.
The ACNT-H511/H511C with 15-mm creepage/clearance
and high-voltage insulation capability is suitable for isolated
communication logic interface and control in high-voltage
power systems such as 690VAC drives, renewable
inverters, energy storage, and medical equipment.
Applications
Figure 1: Functional Diagram
NC
1
8
VCC
Anode
2
7
NC
Cathode
3
6
VO
NC
4
5
GND
CTI 600V, Material Group I (ACNT-H511C)
TTL compatible
Package: 15-mm stretched SO8 package
Open-Collector Output
40 kV/µs typical common-mode rejection at
VCM = 1500V
Guaranteed performance within temperature range:
–40°C to +105°C
Worldwide safety approval:
– UL1577 recognized: 7500VRMS for 1 minute
– CSA approval
– IEC 60747-5-5 approval for reinforced insulation
High-voltage power systems, for example, 690V AC
drives
Renewable energy inverters
Feedback elements in switching power supplies
Digital isolation for A/D, D/A conversion digital field
Communications interface
MCU interface
CAUTION! It is advised that normal static precautions be
taken in handling and assembly of this
component to prevent damage and/or
degradation that may be induced by ESD. The
components featured in this data sheet are not
to be used in military or aerospace applications
or environments.
Table 1: Truth Table
LED
Output
ON
L
OFF
H
A 0.1-µF bypass capacitor must be connected between pins VCC
and GND.
Broadcom
ACNT-H511-DS104
April 17, 2020
ACNT-H511/H511C Data Sheet
Open-Collector Output Optocoupler in 15-mm Stretched SO8 Package
Ordering Information
ACNT-H511/H511C is UL Recognized with 7500Vrms for 1 minute per UL1577.
Option
RoHS
Compliant
Part Number
ACNT-H511/H511C
-000E
-500E
Package
Surface
Mount
15-mm
Stretched SO8
X
Tape and
Reel
UL 1577
X
X
80 per tube
X
X
X
1000 per reel
X
IEC 60747-5-5
Quantity
To order, choose a part number from the part number column and combine with the desired option from the option column
to form an order entry.
Package Outline Drawing
ACNT-H511/H511C Stretched SO8 Package
Lead Free
0.457 ±0.100
[0.018 ±0.004]
Land Pattern Recommendation
Device Part Number
17.857 Ref
[0.703]
NNNN
NNNNN
Ɣ
YYWW
EEE
1.270
[0.05]
BSC
Lot ID
Date Code
13.600 ± 0.127
[0.535 ± 0.005]
7°
0.20 ±0.10
[0.008 ± 0.004]
7°
1.905 Ref
[0.075]
14.047
[0.553]
15.01
[0.591]
0.635 Min
[0.025]
0.630
[0.025]
6.248 ±0.127
[0.246 ±0.005]
8° Nom
16.61 ±0.25
[0.654 ±0.010]
0.254 ±0.050
[0.010 ±0.002]
3.607 ± 0.127
[0.142 ± 0.005]
7°
7°
Dimensions in mm [inch]
Maximum Mold Flash on each side is 0.127 mm [0.005 inch]
Note: Floating Lead Protusion is 0.15 mm [0.006 inch] Max if applicable
Solder Reflow Profile
Recommended reflow conditions are as per JEDEC Standard, J-STD-020 (latest revision). Non-halide flux should be used.
Broadcom
ACNT-H511-DS104
2
ACNT-H511/H511C Data Sheet
Open-Collector Output Optocoupler in 15-mm Stretched SO8 Package
Regulatory Information
The ACNT-H511/H511C is approved by the following organizations:
UL
Approval under UL 1577, component recognition program up to VISO = 7500VRMS File E55361.
CSA
Approval under CSA Component Acceptance Notice #5, File CA 88324.
IEC 60747-5-5
Maximum Working Insulation Voltage VIORM = 2262VPEAK
Insulation and Safety Related Specifications
Parameter
Symbol
ACNT-H511
ACNT-H511C
Unit
Conditions
Minimum External Air Gap
(External Clearance)
L(101)
14.2
mm
Measured from input terminals to output
terminals, shortest distance through air.
Minimum External Tracking
(External Creepage)
L(102)
15
mm
Measured from input terminals to output
terminals, shortest distance path along body.
0.5
mm
Through insulation distance conductor to
conductor, usually the straight line distance
thickness between the emitter and detector.
Minimum Internal Plastic Gap
(Internal Clearance)
Tracking Resistance
(Comparative Tracking Index)
CTI
Isolation Group
>300
≥600
IIIa
I
V
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
IEC 60747-5-5 Insulation Characteristicsa
Description
Symbol
Installation Classification per DIN VDE 0110/39, Table 1
for rated mains voltage 600VRMS
Unit
I – IV
I – IV
for rated mains voltage 1000VRMS
Climatic Classification
40/105/21
Pollution Degree (DIN VDE 0110/39)
Maximum Working Insulation Voltage
Characteristic
2
VIORM
2262
Vpeak
Input to Output Test Voltage, Method ba
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial Discharge < 5 pC
VPR
4241
Vpeak
Input to Output Test Voltage, Method aa
VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec, Partial Discharge < 5 pC
VPR
3619
Vpeak
VIOTM
12000
Vpeak
TS
IS, INPUT
PS, OUTPUT
150
230
1000
°C
mA
mW
RS
>109
Ω
Highest Allowable Overvoltage (Transient Overvoltage tini = 60 sec)
Safety-limiting values – Maximum Values Allowed in the Event of a Failure
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500V
a. Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC
60747-5-5) for a detailed description of Method a and Method b partial discharge test profiles.
Broadcom
ACNT-H511-DS104
3
ACNT-H511/H511C Data Sheet
NOTE:
Open-Collector Output Optocoupler in 15-mm Stretched SO8 Package
These optocouplers are suitable for safe electrical isolation only within the safety limit data. Maintenance of the
safety limit data shall be ensured by means of protective circuits.
Absolute Maximum Ratings
Parameter
Symbol
Min.
Max.
Unit
Storage Temperature
TS
–55
125
°C
Operating Temperature
TA
–40
105
°C
Average Forward Input Current
IF(avg)
—
20
mA
Peak Forward Input Current
(
很抱歉,暂时无法提供与“ACNT-H511-000E”相匹配的价格&库存,您可以联系我们找货