ACPL-796J
Optically Isolated Sigma-Delta Modulator
Data Sheet
Description
Features
The ACPL-796J is a 1-bit, second-order sigma-delta ()
modulator converts an analog input signal into a highspeed data stream with galvanic isolation based on optical
coupling technology. The ACPL-796J operates from a 5 V
power supply with dynamic range of 80 dB with an appropriate digital filter. The differential inputs of ±200 mV (full
scale ±320 mV) are ideal for direct connection to shunt
resistors or other low-level signal sources in applications
such as motor phase current measurement.
The analog input is continuously sampled by means of
sigma-delta over-sampling using external clock, coupled
across the isolation barrier, which allows synchronous
operation with any digital controller. The signal information is contained in the modulator data, as a density
of ones with data rate up to 20 MHz, and the data are
encoded and transmitted across the isolation boundary
where they are recovered and decoded into high-speed
data stream of digital ones and zeros. The original signal
information can be reconstructed with a digital filter. The
serial interface has a wide supply range of 3 V to 5.5 V.
Combined with superior optical coupling technology,
the modulator delivers high noise margins and excellent
immunity against isolation-mode transients. With 0.5 mm
minimum distance through insulation (DTI), the ACPL-796J
provides reliable double protection and high working
insulation voltage, which is suitable for fail-safe designs.
This outstanding isolation performance is superior to
alternatives including devices based on capacitive- or
magnetic-coupling with DTI in micro-meter range. Offered
in an SO-16 package, the isolated ADC delivers the reliability, small size, superior isolation and over-temperature
performance motor drive designers need to accurately
measure current at much lower price compared to traditional current transducers.
Applications
Motor phase and rail current sensing
Power inverter current and voltage sensing
Industrial process control
Data acquisition systems
General purpose current and voltage sensing
Traditional current transducer replacements
Functional Block Diagram
VDD1
VIN +
VIN −
VDD2
Σ−Δ
MODULATOR/
ENCODER
BUF
The internal clock version modulators, HCPL-7860 (DIP-8/
gull wing surface mount package) and HCPL-786J (SO-16
package), are also available.
5 MHz to 20 MHz external clock input range
1-bit, second-order sigma-delta modulator
16 bits resolution no missing codes (12 bits ENOB)
74 dB minimum SNR
3.5 V/°C maximum offset drift
±1% maximum gain error
Internal reference voltage
±200 mV linear range with single 5 V supply
3 V to 5.5 V wide supply range for digital interface
–40°C to +105°C operating temperature range
SO-16 package
25 kV/s common-mode transient immunity
Safety and regulatory approval:
IEC/EN/DIN EN 60747-5-5: 1414 Vpeak working
insulation voltage
UL 1577: 5000 Vrms/1min double protection rating
CSA: Component Acceptance Notice #5
GND1
VREF
LED
DRIVER
DECODER
MDAT
SHIELD
LED
DRIVER
CLOCK
DETECTOR
SHIELD
ACPL-796J
Figure 1.
CAUTION: It is advised that normal static precautions be taken in handling and assembly of this
component to prevent damage and/or degradation which may be induced by ESD. The components
featured in this datasheet are not to be used in military or aerospace applications or environments.
MCLKIN
GND2
Pin Configuration and Descriptions
VDD1
1
ACPL-796J
16 GND2
VIN+ 2
15 NC
VIN– 3
14 VDD2
GND1
4
13 MCLKIN
NC
5
12 NC
NC
6
11 MDAT
VDD1
7
10 NC
GND1
8
9
GND2
Figure 2. Pin configuration.
Table 1. Pin descriptions.
Pin No.
Symbol
Description
1, 7
VDD1
Supply voltage for signal input side (analog side), relative to GND1
2
VIN+
Positive analog input, recommended input range ±200 mV
3
VIN–
Negative analog input, recommended input range ±200 mV (normally connected to GND1)
4, 8
GND1
Supply ground for signal input side
5, 6, 10, 12, 15
NC
No connection. Leave floating
9, 16
GND2
Supply ground for data output side (digital side)
11
MDAT
Modulator data output
13
MCLKIN
Modulator clock input, 5 MHz to 20 MHz
14
VDD2
Supply voltage for data output side, relative to GND2
Table 2. Ordering Information
ACPL-796J is UL recognized with 5000 Vrms/1 minute rating per UL 1577.
Part number
Option
(RoHS Compliant)
Package
-000E
ACPL-796J
-060E
Surface Mount
Tape& Reel
IEC/EN/DIN EN
60747-5-5
X
SO-16
Quantity
45 per tube
X
X
-500E
X
X
-560E
X
X
45 per tube
850 per reel
X
850 per reel
To order, choose a part number from the part number column and combine with the desired option from the option
column to form an order entry.
Example:
ACPL-796J-560E to order product of Surface Mount package in Tape and Reel packaging with IEC/EN/DIN EN 60747-5-5
Safety Approval and RoHS compliance.
Option datasheets are available. Contact your Avago sales representative or authorized distributor for information.
2
Package Outline Drawings
16-Lead Surface Mount
0.457
(0.018)
LAND PATTERN RECOMMENDATION
1.270
(0.050)
16 15 14 13 12 11 10
0.64 (0.025)
9
TYPE NUMBER
DATE CODE
A XXXX
YYWW
EEE
AVAGO
LEAD-FREE
7.493 ± 0.254
(0.295 ± 0.010)
PIN 1 DOT
11.63 (0.458)
LOT ID
2.16 (0.085)
1
2
3
4
5
6
7
8
10.312 ± 0.254
(0.406 ± 0.10)
8.763 ± 0.254
(0.345 ± 0.010)
9°
0.457
(0.018)
Dimensions in Millimeters (Inches)
3.505 ± 0.127
(0.138 ± 0.005)
0-8°
0.64 (0.025) MIN.
10.363 ± 0.254
(0.408 ± 0.010)
ALL LEADS TO
BE COPLANAR
± 0.05 (0.002)
0.203 ± 0.076
(0.008 ± 0.003)
STANDOFF
Floating lead protrusion is 0.25 mm (10 mils) Max.
Note: Initial and continued variation in color of the white mold compound is normal and does not affect performance or reliability of the device
Figure 3. 16-Lead Surface Mount.
3
Recommended Pb-Free IR Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
Regulatory Information
The ACPL-796J is approved by the following organizations:
Approval under: DIN EN 60747-5-5 (VDE 0884-5):2011-11 EN 60747-5-5:2011
IEC/EN/DIN EN 60747-5-5
Approval under UL 1577, component recognition program up to VISO = 5000 VRMS. File E55361.
UL
Approval under CSA Component Acceptance Notice #5, File CA 88324.
CSA
Table 3. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics [1]
Description
Symbol
Value
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 450 V rms
for rated mains voltage ≤ 600 Vrms
for rated mains voltage ≤ 1000 Vrms
I-IV
I-IV
I-IV
I-IV
I-III
Climatic Classification
55/105/21
Pollution Degree (DIN VDE 0110/1.89)
2
Units
VIORM
1414
Vpeak
Input to Output Test Voltage, Method b
VIORM × 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial Discharge < 5 pC
VPR
2652
Vpeak
Input to Output Test Voltage, Method a
VIORM × 1.6 = VPR, Type and Sample Test, tm = 10 sec,
Partial Discharge < 5 pC
VPR
2262
Vpeak
Highest Allowable Overvoltage (Transient Overvoltage, tini = 60 sec)
VIOTM
8000
Vpeak
Safety-limiting values (Maximum values allowed in the event of a failure)
Case Temperature
Input Current[2]
Output Power[2]
TS
IS,INPUT
PS,OUTPUT
175
400
600
°C
mA
mW
Insulation Resistance at TS, VIO = 500 V
RS
≥ 109
Maximum Working Insulation Voltage
OUTPUT POWER - PS, INPUT CURRENT - IS
Notes:
1. Insulation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits within the
application.
2. Safety-limiting parameters are dependent on ambient temperature. Refer to the following figure for dependence of PS and IS on ambient
temperature.
800
700
PS (mW)
IS (mA)
600
500
400
300
200
100
0
0 25 50 75 100 125 150 175 200
TS - CASE TEMPERATURE - oC
Figure 4.
4
Table 4. Insulation and Safety Related Specifications
Parameter
Symbol
Value
Units
Conditions
Minimum External Air Gap
(External Clearance)
L(101)
8.3
mm
Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking
(External Creepage)
L(102)
8.3
mm
Measured from input terminals to output terminals,
shortest distance path along body
0.5
mm
Through insulation distance, conductor to conductor,
usually the direct distance between the photoemitter
and photodetector inside the optocoupler cavity
>175
V
DIN IEC 112/VDE 0303 Part 1
Minimum Internal Plastic Gap
(Internal Clearance)
Tracking Resistance
(Comparative Tracking Index)
CTI
Isolation Group
IIIa
Material Group (DIN VDE 0110, 1/89, Table 1)
Table 5. Absolute Maximum Ratings
Parameter
Symbol
Min.
Max.
Units
Storage Temperature
TS
–55
+125
°C
Ambient Operating Temperature
TA
–40
+105
°C
Supply voltage
VDD1, VDD2
–0.5
6.0
V
Steady-State Input Voltage[1,3]
VIN+, VIN–
–2
VDD1 + 0.5
V
Two-Second Transient Input Voltage[2]
VIN+, VIN–
–6
VDD1 + 0.5
V
Digital Input/Output Voltages
MCLKIN, MDAT
–0.5
VDD2 + 0.5
V
Lead Solder Temperature
260°C for 10 sec., 1.6 mm below seating plane
Notes:
1. DC voltage of up to –2 V on the inputs does not cause latch-up or damage to the device; tested at typical operating conditions.
2. Transient voltage of 2 seconds up to –6 V on the inputs does not cause latch-up or damage to the device; tested at typical operating conditions.
3. Absolute maximum DC current on the inputs = 100 mA, no latch-up or device damage occurs.
Table 6. Recommended Operating Conditions
Parameter
Symbol
Min.
Max.
Units
Ambient Operating Temperature
TA
–40
+105
°C
VDD1 Supply Voltage
VDD1
4.5
5.5
V
VDD2 Supply Voltage
VDD2
3
5.5
V
Analog Input Voltage[1]
VIN+, VIN–
–200
+200
mV
Notes:
1. Full scale signal input range ±320 mV.
5
Table 7. Electrical Specifications
Unless otherwise noted, TA = –40°C to +105°C, VDD1 = 4.5 V to 5.5 V, VDD2 = 3 V to 5.5 V, VIN+ = –200 mV to +200 mV, and
VIN– = 0 V (single-ended connection); tested with Sinc3 filter, 256 decimation ratio, fMCLKIN = 10 MHz.
Parameter
Symbol
Min.
Typ.[1]
Max.
Units
Test Conditions/Notes
STATIC CHARACTERISTICS
Resolution
Integral Nonlinearity
INL
16
–15
–25
3
3
15
25
Bits
LSB
LSB
Decimation filter output set to 16 bits
TA = –40°C to +85°C; see Definitions section
TA = 85°C to 105°C
–25
25
0.9
LSB
No missing codes, guaranteed by design;
see Definitions section
4.5
3.5
mV
V/°C
TA = –40°C to +105°C; see Definitions section
–2
2
V/V
%
–1
1
%
Differential Nonlinearity
DNL
–0.9
Offset Error
VOS
–1
Offset Drift vs.
Temperature
Offset Drift vs. VDD1
Gain Error
TCVOS
Gain Error Drift vs.
Temperature
Gain Error Drift vs. VDD1
ANALOG INPUTS
Full-Scale Differential
Voltage Input Range
Average Input Bias Current
Average Input Resistance
Input Capacitance
DYNAMIC CHARACTERISTICS
Signal-to-Noise Ratio
Signal-to(Noise + Distortion)
Ratio
3
120
GE
VIN+ = –250 mV to +250mV
TA = –40°C to +105°C, VIN+ = –250 to +250 mV;
see Definitions section
TA = 25°C, VIN+ = –250 to +250 mV
60
ppm/°C
110
V/V
FSR
±320
mV
VIN = VIN+ – VIN–; Note 2
IINA
RIN
CINA
–0.5
33
8
A
k
pF
6
74
65
80
75
dB
dB
VDD1 = 5V, VDD2 = 5V, VIN+ = 0 V; Note 3
Across VIN+ or VIN– to GND1; Note 3
Across VIN+ or VIN– to GND1
VIN+ = –200 mV to +200 mV, 543 Hz, sine wave; Note 4
TA = –40°C to +105°C; see Definitions section
TA = –40°C to +105°C; see Definitions section
68
75
dB
TA = –40°C to +85°C
7, 8
TA = –40°C to +105°C, VIN+ = –250 mV to +250 mV
7
TCGE
SNR
SNDR
65
Effective Number of Bits
Isolation Transient Immunity
Common-Mode Rejection
Ratio
DIGITAL INPUTS AND OUTPUTS
Input High Voltage
ENOB
CMR
CMRR
Input Low Voltage
VIL
Input Current
Input Capacitance
Output High Voltage
IIND
CIND
VOH
Output Low Voltage
POWER SUPPLY
VDD1 Supply Current
VDD2 Supply Current
VIH
12
25
74
Bits
kV/V
dB
see Definitions section
VCM = 1 kV; See Definitions section
V
Note 5
V
Note 5
VDD2
– 0.2
±0.5
6
VDD2
– 0.1
A
pF
V
VDD2 = 5 V supply, IOUT = –200 A
VDD2
– 0.15
VDD2
– 0.1
V
VDD2 = 3.3 V supply, IOUT = –200 A
0.4
V
IOUT = +200 A
14
6
19
8
mA
mA
VDD2 = 5 V supply
5
7
mA
VDD2 = 3.3 V supply
0.8 ×
VDD2
0.2 ×
VDD2
VOL
IDD1
IDD2
Notes:
1. All Typical values are at TA = 25°C, VDD1 = 5 V, VDD2 = 5 V.
2. Beyond the full-scale input range the data output is either all zeroes or all ones.
3. Because of the switched-capacitor nature of the isolated modulator, time averaged values are shown.
4. Signal frequency of 543 Hz is used as a reference frequency for coherent sampling.
5. Ensured by design.
6
Fig.
7, 8
9, 10
11, 12
Table 8. Timing Specifications
Unless otherwise noted, TA = –40°C to +105°C, VDD1 = 4.5 V to 5.5 V, VDD2 = 3 V to 5.5 V.
Parameter
Symbol
Min.
Typ.
Max.
Units
Test Conditions/Notes
Modulator Clock Input Frequency
fMCLKIN
5
10
20
MHz
Clock duty cycle 40% to 60%
Data Delay After Rising Edge of
MCLKIN[1]
tD
3
15
ns
CL = 15 pF
Fig.
5
Notes:
1. Data changes at the clock rising edge so it can be safely read at the falling edge, although it can be read at the rising edge if preferred.
2. When VDD1 is not supplied, MDAT is high ie modulator output level is “1”
MCLKIN
tD
MDAT
Figure 5. Data timing.
Table 9. Package Characteristics
Parameter
Symbol
Min.
Input-Output Momentary
Withstand Voltage
VISO
5000
Input-Output Resistance
RI-O
1012
Typ.
1013
1011
Max.
Units
Test Conditions
Note
Vrms
RH ≤ 50%, t = 1 min;
TA = 25°C
1, 2
VI-O = 500 Vdc
2
TA = 100°C
2
Input-Output Capacitance
CI-O
1.4
pF
f = 1 MHz
2
Input IC Junction-to-Ambient
Thermal Resistance
JAI
83
°C/W
1 oz. trace, 2-layer PCB,
still air, TA = 25°C
3
Output IC Junction-to- Ambient
Thermal Resistance
JAO
85
°C/W
1 oz. trace, 2-layer PCB,
still air, TA = 25°C
3
Notes:
1. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 6000 Vrms for 1 second. This test is performed
before the 100% production test for partial discharge (method b) shown in IEC/EN/DIN EN 60747-5-5 Insulation Characteristic Table.
2. This is a two-terminal measurement: pins 1-8 are shorted together and pins 9-16 are shorted together.
3. Maximum power dissipation in analog side and digital side IC’s needs to be limited to ensure that their respective junction temperature is less than
125°C. The maximum permissible power dissipation is dependent on the thermal impedance and the ambient temperature.
7
Typical Performance Plots
50
40
MCLKIN = 20 MHz
30
MCLKIN
=
10
MHz
20
10
0
MCLKIN = 5 MHz
-10
-20
-30
-40
-50
-400 -320 -240 -160 -80 0
80 160 240 320 400
VIN+ (mV)
80
79
78
77
76
75
74
73
72
71
70
MCLKIN = 10 MHz
MCLKIN = 20 MHz
MCLKIN = 5 MHz
50
75
100 125 150 175 200 225 250 275 300
VIN+ (mV)
20
18
TA = +105°C
16 TA = +85°C
MCLKIN = 10 MHz
MCLKIN = 5 MHz
MCLKIN = 20 MHz
14
TA = +25°C
12
TA = –40°C
10
8
-40
-20
0
20
40
60
TEMPERATURE (°C)
80
100
120
18
16
MCLKIN = 20 MHz
MCLKIN = 10 MHz
14
12
MCLKIN = 5 MHz
10
8
6
-320
-240
-160
-80
6
-320
-240
-160
-80
0
80
VIN+ (mV)
Figure 9. IDD1 vs. VIN DC input at various temperatures.
20
IDD1 (mA)
fIN = 543 Hz
fIN = 543 Hz
Figure 8. SNDR vs. temperature.
0
80
VIN+ (mV)
Figure 10. IDD1 vs. VIN DC input for various frequencies.
8
80
78
76
74
72
70
68
66
64
62
60
Figure 7. SNDR vs. input voltage VIN.
IDD1 (mA)
SNDR (dB)
Figure 6. Input current vs. input voltage.
SNDR (dB)
IIN+ (μA)
Unless otherwise noted, TA = 25°C, VDD1 = 5 V, VDD2 = 5 V, VIN+ = –200 mV to +200 mV, and VIN– = 0 V, fMCLKIN = 10 MHz,
with Sinc3 filter, 256 decimation ratio.
160
240
320
160
240
320
8
8
7
7
TA = +105°C
6
TA = +85°C
TA = +25°C
5
IDD2 (mA)
IDD2 (mA)
6
TA = –40°C
4
MCLKIN = 10 MHz
5
MCLKIN = 5 MHz
4
3
3
2
-320
MCLKIN = 20 MHz
-240
-160
-80
0
80
VIN+ (mV)
160
240
320
Figure 11. IDD2 vs. VIN DC input at various temperatures.
2
-320
-240
-160
-80
0
80
VIN+ (mV)
160
240
320
Figure 12. IDD2 vs. VIN DC input for various frequencies.
Definitions
Integral Nonlinearity (INL)
Signal-to-Noise Ratio (SNR)
INL is the maximum deviation of a transfer curve from a
straight line passing through the endpoints of the ADC
transfer function, with offset and gain errors adjusted out.
The SNR is the measured ratio of AC signal power to noise
power below half of the sampling frequency. The noise
power excludes harmonic signals and DC.
Differential Nonlinearity (DNL)
Signal-to-(Noise + Distortion) Ratio (SNDR)
DNL is the deviation of an actual code width from the
ideal value of 1 LSB between any two adjacent codes in
the ADC transfer curve. DNL is a critical specification in
closed-loop applications. A DNL error of less than ±1 LSB
guarantees no missing codes and a monotonic transfer
function.
The SNDR is the measured ratio of AC signal power to
noise plus distortion power at the output of the ADC. The
signal power is the rms amplitude of the fundamental
input signal. Noise plus distortion power is the rms sum
of all non-fundamental signals up to half the sampling
frequency (excluding DC).
Offset Error
Effective Number of Bits (ENOB)
Offset error is the deviation of the actual input voltage
corresponding to the mid-scale code (32,768 for a 16-bit
system with an unsigned decimation filter) from 0 V. Offset
error can be corrected by software or hardware.
The ENOB determines the effective resolution of an ADC,
expressed in bits, defined by ENOB = (SNDR − 1.76)/6.02
Gain Error
Gain error is the the difference between the ideal gain
slope and the actual gain slope, with offset error adjusted
out. Gain error includes reference error. Gain error can be
corrected by software or hardware.
9
Isolation Transient Immunity (CMR)
The isolation transient immunity (also known as CommonMode Rejection or CMR) specifies the minimum rate-ofrise/fall of a common-mode signal applied across the
isolation boundary beyond which the modulator clock or
data is corrupted.
Product Overview
Description
The ACPL-796J isolated sigma-delta () modulator
converts an analog input signal into a high-speed (up
to 20 MHz) single-bit data stream by means of a sigmadelta over-sampling modulator. The time average of the
modulator data is directly proportional to the input signal
voltage. The modulator uses external clock ranges from 5
MHz to 20 MHz that is coupled across the isolation barrier.
This arrangement allows synchronous operation of data
acquisition to any digital controller, and adjustable clock
for speed requirements of the application. The modulator
data are encoded and transmitted across the isolation
boundary where they are recovered and decoded into
high-speed data stream of digital ones and zeros. The
original signal information is represented by the density
of ones in the data output.
The other main function of the modulator (optocoupler)
is to provide galvanic isolation between the analog signal
input and the digital data output. It provides high noise
margins and excellent immunity against isolation-mode
transients that allows direct measurement of low-level
signals in highly noisy environments, for example measurement of moor phase currents in power inverters.
With 0.5 mm minimum DTI, the ACPL-796J provides reliable
double protection and high working insulation voltage,
which is suitable for fail-safe designs. This outstanding
isolation performance is superior to alternatives including
devices based on capacitive- or magnetic-coupling with
DTI in micro-meter range. Offered in an SO-16 package,
the isolated ADC delivers the reliability, small size, superior
isolation and over-temperature performance motor drive
designers need to accurately measure current at much
lower price compared to traditional current transducers.
Analog Input
The differential analog inputs of the ACPL-796J are implemented with a fully-differential, switched-capacitor
circuit. The ACPL-796J accepts signal of ±200 mV (full scale
±320 mV), which is ideal for direct connection to shunt
based current sensing or other low-level signal sources
applications such as motor phase current measurement.
An internal voltage reference determines the full-scale
analog input range of the modulator (±320 mV); an input
range of ±200 mV is recommended to achieve optimal
performance. Users are able to use higher input range,
for example ±250 mV, as long as within full-scale range,
for purpose of over-current or overload detection. Figure
13 shows the simplified equivalent circuit of the analog
input.
10
200Ω (TYP)
VIN+
fSWITCH
= MCLKIN
3 pF (TYP)
1.5 pF
ANALOG
GROUND
COMMON MODE
VOLTAGE
1.5 pF
fSWITCH
= MCLKIN
3 pF (TYP)
200Ω (TYP)
VIN–
Figure 13. Analog input equivalent circuit.
In the typical application circuit (Figure 17), the ACPL-796J
is connected in a single-ended input mode. Given the
fully differential input structure, a differential input connection method (balanced input mode as shown in Figure
14) is recommended to achieve better performance. The
input currents created by the switching actions on both of
the pins are balanced on the filter resistors and cancelled
out each other. Any noise induced on one pin will be
coupled to the other pin by the capacitor C and creates
only common mode noise which is rejected by the device.
Typical value for Ra and Rb is 22 and 10 nF for C.
5V
VDD1
Ra
VIN+
+Analog Input
Rb
–
–Analog
Input
C
ACPL-796J
VIN–
GND1
Figure 14. Simplified differential input connection diagram.
Latch-up Consideration
Modulator Data Output
Latch-up risk of CMOS devices needs careful consideration, especially in applications with direct connection to
signal source that is subject to frequent transient noise.
The analog input structure of the ACPL-796J is designed
to be resilient to transients and surges, which are often
encountered in highly noisy application environments
such as motor drive and other power inverter systems.
Other situations could cause transient voltages to the
inputs include short circuit and overload conditions. The
ACPL-796J is tested with DC voltage of up to –2 V and 2second transient voltage of up to –6 V to the analog inputs
and there is no latch-up or damage to the device.
Input signal information is contained in the modulator
output data stream, represented by the density of ones
and zeros. The density of ones is proportional to the input
signal voltage, as shown in Figure 15. A differential input
signal of 0 V ideally produces a data stream of ones 50%
of the time and zeros 50% of the time. A differential input
of –200 mV corresponds to 18.75% density of ones, and
a differential input of +200 mV is represented by 81.25%
density of ones in the data stream. A differential input of
+320 mV or higher results in ideally all ones in the data
stream, while input of –320 mV or lower will result in all
zeros ideally. Table 10 shows this relationship.
MODULATOR OUTPUT
+FS (ANALOG INPUT)
0 V (ANALOG INPUT)
–FS (ANALOG INPUT)
ANALOG INPUT
TIME
Figure 15. Moudlator output vs. analog input.
Table 10. Input voltage with ideal corresponding density of 1s at modulator data output, and ADC code.
Analog Input
Voltage Input
Density of 1s
ADC Code (16-bit unsigned decimation)
Full-Scale Range
640 mV
+Full-Scale
+320 mV
100%
65,535
+Recommended Input Range
+200 mV
81.25%
53,248
Zero
0 mV
50%
32,768
–Recommended Input Range
–200 mV
18.75%
12,288
–Full-Scale
–320 mV
0%
0
Notes:
1. With bipolar offset binary coding scheme, the digital code begins with digital 0 at –FS input and increases proportionally to the analog input until
the full-scale code is reached at the +FS input. The zero crossing occurs at the mid-scale input.
2. Ideal density of 1s at modulator data output can be calculated with VIN/640 mV + 50%; similarly, the ADC code can be calculated with (VIN/640 mV)
× 65,536 + 32,768, assuming a 16-bit unsigned decimation filter.
11
Digital Filter
clock frequency, 256 decimation ratio and 16-bit word
settings, the output data rate is 39 kHz (= 10 MHz/256).
This filter can be implemented in an ASIC, an FPGA or a
DSP. Some of the ADC codes with corresponding input
voltages are shown in Table 10.
A digital filter converts the single-bit data stream from
the modulator into a multi-bit output word similar to
the digital output of a conventional A/D converter. With
this conversion, the data rate of the word output is also
reduced (decimation). A Sinc3 filter is recommended to
work together with the ACPL-796J. With a 10 MHz external
INPUT
CURRENT
RSHUNT
10
PF
NONISOLATED
5 V/3.3 V
ISOLATION
BARRIER
ISOLATED
5V
0.1
PF
VDD1
VDD2
VIN+
MCLKIN
VIN–
MDAT
GND1
GND2
VDD
0.1
PF
10
PF
CLOCK
DATA
SCLK
SDAT
CS
3-WIRE
SERIAL
INTERFACE
GND
SINC3 FILTER
GND1
ACPL-796J
GND2
Note: In applications, a 0.1 F bypass capacitor must be connected between pins VDD1 and
GND1, and between pins VDD2 and GND2 of the ACPL-796J.
Figure 16. Typical application circuit with a Sinc3 filter.
12
Application Information
Digital Current Sensing Circuit
Figure 17 shows a typical application circuit for motor control phase current sensing. By choosing the appropriate shunt
resistance, any range of current can be monitored, from less than 1 A to more than 100 A.
FLOATING POSITIVE
SUPPLY
HV+
GATE
DRIVE
CIRCUIT
MOTOR
+
–
R2 39 :
RSENSE
HV–
C4
C1
10 PF 0.1 PF VDD1
D1
5.1 V
C2
10 nF
GND1
NONISOLATED
5 V/3.3 V
ISOLATION
BARRIER
R1
VDD2
MCLKIN
VIN+
VIN–
MDAT
GND1
GND2
ACPL-796J
C5
10 PF
C3
0.1 PF
GND2
Figure 17. Typical application circuit for motor phase current sensing.
Power Supplies and Bypassing
As shown in Figure 17, a floating power supply (which in
many applications could be the same supply that is used
to drive the high-side power transistor) is regulated to 5
V using a simple zener diode (D1); the value of resistor
R1 should be chosen to supply sufficient current from
the existing floating supply. The voltage from the current
sensing resistor or shunt (RSENSE) is applied to the input of
the ACPL-796J through an RC anti-aliasing filter (R2 and
C2). And finally, a clock is connected to the ACPL-796J and
data are connected to the digital filter. Although the application circuit is relatively simple, a few recommendations
should be followed to ensure optimal performance.
As shown in Figure 17, 0.1 F bypass capacitors (C1 and
C3) should be located as close as possible to the input and
output power-supply pins of the isolated modulator. The
bypass capacitors are required because of the high-speed
digital nature of the signals inside the isolated modulator.
For better filtering, an additional 10-μF capacitor can be
used. A 10 nF bypass capacitor (C2) is also recommended
at the input due to the switched-capacitor nature of the
input circuit. The input bypass capacitor also forms part of
the anti-aliasing filter, which is recommended to prevent
high frequency noise from aliasing down to lower frequencies and interfering with the input signal.
The power supply for the isolated modulator is most
often obtained from the same supply used to power the
power transistor gate drive circuit. If a dedicated supply
is required, in many cases it is possible to add an additional winding on an existing transformer. Otherwise,
some sort of simple isolated supply can be used, such as
a line powered transformer or a high-frequency DC-DC
converter.
PC Board Layout
An inexpensive 78L05 three terminal regulator can also be
used to reduce the floating supply voltage to 5 V. To help
attenuate high-frequency power supply noise or ripple, a
resistor or inductor can be used in series with the input of
the regulator to form a low-pass filter with the regulator’s
input bypass capacitor.
13
The design of the printed circuit board (PCB) should follow
good layout practices, such as keeping bypass capacitors
close to the supply pins, keeping output signals away from
input signals, the use of ground and power planes, etc. In
addition, the layout of the PCB can also affect the isolation
transient immunity (CMR) of the isolated modulator, due
primarily to stray capacitive coupling between the input
and the output circuits. To obtain optimal CMR performance, the layout of the PC board should minimize any
stray coupling by maintaining the maximum possible
distance between the input and output sides of the circuit
and ensuring that any ground or power plane on the PC
board does not pass directly below or extend much wider
than the body of the isolated modulator.
Shunt Resistors
The current-sensing shunt resistor should have low resistance (to minimize power dissipation), low inductance
(to minimize di/dt induced voltage spikes which could
adversely affect operation), and reasonable tolerance (to
maintain overall circuit accuracy). Choosing a particular value for the shunt is usually a compromise between
minimizing power dissipation and maximizing accuracy.
Smaller shunt resistances decrease power dissipation,
while larger shunt resistances can improve circuit accuracy
by utilizing the full input range of the isolated modulator.
MOTOR OUTPUT POWER - HORSEPOWER
The first step in selecting a shunt is determining how
much current the shunt will be sensing. The graph in
Figure 18 shows the RMS current in each phase of a threephase induction motor as a function of average motor
output power (in horsepower, hp) and motor drive supply
voltage. The maximum value of the shunt is determined
by the current being measured and the maximum recommended input voltage of the isolated modulator. The
maximum shunt resistance can be calculated by taking the
maximum recommended input voltage and dividing by
the peak current that the shunt should see during normal
operation. For example, if a motor will have a maximum
RMS current of 10 A and can experience up to 50%
overloads during normal operation, then the peak current
is 21.1 A (= 10 × 1.414 × 1.5). Assuming a maximum input
voltage of 200 mV, the maximum value of shunt resistance
in this case would be about 10 m.
40
440
380
220
120
35
30
25
20
15
10
5
0
5 10 15 20 25 30 35
MOTOR PHASE CURRENT - A (rms)
Figure 18. Motor Output Horsepower vs. Motor Phase Current and Supply.
0
The maximum average power dissipation in the shunt
can also be easily calculated by multiplying the shunt
resistance times the square of the maximum RMS current,
which is about 1 W in the previous example.
If the power dissipation in the shunt is too high, the resistance of the shunt can be decreased below the maximum
14
value to decrease power dissipation. The minimum value
of the shunt is limited by precision and accuracy requirements of the design. As the shunt value is reduced, the
output voltage across the shunt is also reduced, which
means that the offset and noise, which are fixed, become
a larger percentage of the signal amplitude. The selected
value of the shunt will fall somewhere between the
minimum and maximum values, depending on the particular requirements of a specific design.
When sensing currents large enough to cause significant heating of the shunt, the temperature coefficient
(tempco) of the shunt can introduce nonlinearity due to
the signal dependent temperature rise of the shunt. The
effect increases as the shunt-to-ambient thermal resistance increases. This effect can be minimized either by
reducing the thermal resistance of the shunt or by using
a shunt with a lower tempco. Lowering the thermal resistance can be accomplished by repositioning the shunt
on the PC board, by using larger PC board traces to carry
away more heat, or by using a heat sink.
For a two-terminal shunt, as the value of shunt resistance
decreases, the resistance of the leads becomes a significant percentage of the total shunt resistance. This has two
primary effects on shunt accuracy. First, the effective resistance of the shunt can become dependent on factors such
as how long the leads are, how they are bent, how far they
are inserted into the board, and how far solder wicks up
the lead during assembly (these issues will be discussed
in more detail shortly). Second, the leads are typically
made from a material such as copper, which has a much
higher tempco than the material from which the resistive
element itself is made, resulting in a higher tempco for the
shunt overall. Both of these effects are eliminated when a
four-terminal shunt is used. A four-terminal shunt has two
additional terminals that are Kelvin-connected directly
across the resistive element itself; these two terminals are
used to monitor the voltage across the resistive element
while the other two terminals are used to carry the load
current. Because of the Kelvin connection, any voltage
drops across the leads carrying the load current should
have no impact on the measured voltage.
Several four-terminal shunts from Isotek (Isabellenhütte)
suitable for sensing currents in motor drives up to 71 Arms
(71 hp or 53 kW) are shown in Table 11; the maximum
current and motor power range for each of the PBV series
shunts are indicated. For shunt resistances from 50 m
down to 10 m, the maximum current is limited by the
input voltage range of the isolated modulator. For the
5 m and 2 m shunts, a heat sink may be required due
to the increased power dissipation at higher currents.
Table 11. Isotek (Isabellenhütte) four-terminal shunt summary.
Shunt
Resistance
Tol.
Maximum
RMS Current
Motor Power Range
120 VAC - 440 VAC
m
%
A
hp
kW
PBV-R050-0.5
50
0.5
3
0.8 - 3
0.6 - 2
PBV-R020-0.5
20
0.5
7
2-7
0.6 - 2
PBV-R010-0.5
10
0.5
14
4 - 14
3 - 10
PBV-R005-0.5
5
0.5
25 [28]
7 - 25 [8 - 28]
5 - 19 [6 - 21]
PBV-R002-0.5
2
0.5
39 [71]
11 - 39 [19 - 71]
8 - 29 [14 - 53]
Shunt Resistor
Part Number
Note: Values in brackets are with a heatsink for the shunt.
When laying out a PC board for the shunts, a couple of
points should be kept in mind. The Kelvin connections to
the shunt should be brought together under the body
of the shunt and then run very close to each other to the
input of the isolated modulator; this minimizes the loop
area of the connection and reduces the possibility of stray
magnetic fields from interfering with the measured signal.
If the shunt is not located on the same PC board as the
isolated modulator circuit, a tightly twisted pair of wires
can accomplish the same thing.
Also, multiple layers of the PC board can be used to increase
current carrying capacity. Numerous plated-through vias
should surround each non-Kelvin terminal of the shunt to
help distribute the current between the layers of the PC
board. The PC board should use 2 or 4 oz. copper for the
layers, resulting in a current carrying capacity in excess of
20 A. Making the current carrying traces on the PC board
fairly large can also improve the shunt’s power dissipation capability by acting as a heat sink. Liberal use of vias
where the load current enters and exits the PC board is
also recommended.
Shunt Connections
The recommended method for connecting the isolated
modulator to the shunt resistor is shown in Figure 17. VIN+
of the ACPL-796J is connected to the positive terminal of
the shunt resistor, while VIN– is shorted to GND1, with the
power-supply return path functioning as the sense line
to the negative terminal of the current shunt. This allows
a single pair of wires or PC board traces to connect the
isolated modulator circuit to the shunt resistor. By referencing the input circuit to the negative side of the sense
resistor, any load current induced noise transients on the
shunt are seen as a common-mode signal and will not
interfere with the current-sense signal. This is important
because the large load currents flowing through the
motor drive, along with the parasitic inductances inherent
15
in the wiring of the circuit, can generate both noise
spikes and offsets that are relatively large compared
to the small voltages that are being measured across the
current shunt.
If the same power supply is used both for the gate
drive circuit and for the current sensing circuit, it is very
important that the connection from GND1 of the isolated
modulator to the sense resistor be the only return path
for supply current to the gate drive power supply in order
to eliminate potential ground loop problems. The only
direct connection between the isolated modulator circuit
and the gate drive circuit should be the positive power
supply line.
In some applications, however, supply currents flowing
through the power-supply return path may cause offset
or noise problems. In this case, better performance may
be obtained by connecting VIN+ and VIN– directly across
the shunt resistor with two conductors, and connecting
GND1 to the shunt resistor with a third conductor for the
power-supply return path, as shown in Figure 19. When
connected this way, both input pins should be bypassed.
To minimize electromagnetic interference of the sense
signal, all of the conductors (whether two or three are
used) connecting the isolated modulator to the sense
resistor should be either twisted pair wire or closely
spaced traces on a PC board.
The 39 resistor in series with the input lead (R2) forms
a low pass anti-aliasing filter with the 10 nF input bypass
capacitor (C2) with a 400 kHz bandwidth. The resistor
performs another important function as well; it dampens
any ringing which might be present in the circuit formed
by the shunt, the input bypass capacitor, and the inductance of wires or traces connecting the two. Undamped
ringing of the input circuit near the input sampling
frequency can alias into the baseband producing what
might appear to be noise at the output of the device.
HV+
FLOATING POSITIVE
SUPPLY
GATE
DRIVE
CIRCUIT
D1
5.1 V
C4
C1
10 PF 0.1 PF VDD1
VDD2
R2a 39 :
MOTOR
MCLKIN
VIN+
+
–
R2b 39 :
RSENSE
C2a
10 nF
NONISOLATED
5 V/3.3 V
ISOLATION
BARRIER
R1
C2b
10 nF
GND1
VIN–
MDAT
GND1
GND2
ACPL-796J
C5
10 PF
C3
0.1 PF
GND2
HV–
Figure 19. Schematic for three conductor shunt connection.
Voltage Sensing
The ACPL-796J can also be used to isolate signals with amplitudes larger than its recommended input range with
the use of a resistive voltage divider at its input. The only
restrictions are that the impedance of the divider be relatively small (less than 1 k) so that the input resistance
(33 k) and input bias current (0.5 A) do not affect the
accuracy of the measurement. An input bypass capacitor
is still required, although the 39 series damping resistor
For product information and a complete list of distributors, please go to our web site:
is not (the resistance of the voltage divider provides the
same function). The low-pass filter formed by the divider
resistance and the input bypass capacitor may limit the
achievable bandwidth. To obtain higher bandwidth, the
input bypass capacitor (C2) can be reduced, but it should
not be reduced much below 1000 pF to maintain adequate
input bypassing of the isolated modulator.
www.avagotech.com
Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies in the United States and other countries.
Data subject to change. Copyright © 2005-2016 Avago Technologies. All rights reserved.
AV02-1670EN - July 27, 2016