Description
Definition of Failure
The reliability data shown includes Avago Technologies
reliability test data from the reliability qualification done
on this product family. All of these products use the same
LEDs, similar IC, and the same packaging materials, processes, stress conditions and testing. The data in Table 1
and Table 2 reflect actual test data for devices on a per
channel basis. Before stress, all devices are preconditioned
using a solder reflow process (260 C peak temp) and 20
temperature cycles (-55 C to +125 C, 15 mins dwell, 1
min transfer). These data are taken from testing on Avago
Technologies devices using internal Avago Technologies
process, material specifications, design standards, and
statistical process controls. THEY ARE NOT TRANSFERABLE TO
Inability to switch, i.e. “functional failure” is the definition
of failure in this data sheet. Specifically, failure occurs
when the device fails to switch ON with 2 times the minimum recommended drive current (but not exceeding the
max rating) or fails to switch off when there is no input
current
Failure Rate Projections
The demonstrated point mean time to failure (MTTF) is
measured at the absolute maximum stress condition. The
failure rate projections in Table 2 uses the Arrhenius acceleration relationship, where a 0.43 eV activation energy is
used as in the hybrid section of MIL-HDBK-217.
OTHER MANUFACTURERS’ SIMILAR PART TYPES.
Application Information
Operating Life Test
For valid system reliability calculations it is necessary to
adjust for the time when the system is not in operation.
Note that if you are using MIL-HDBK-217 for predicting
component reliability, the results may not be comparable
to those given in Table 2 due to different conditions and
factors that have been accounted for in MIL-HDBK-217. For
example it is unlikely that your application will exercise all
available channels at full rated power with the LED(s) always ON as Avago Technologies testing does. Thus, your
application total power and duty cycle must be carefully
considered when comparing Table 2 to predictions using
MIL-HDBK-217.
The data of Table 1 and 2 were obtained on devices with
high temperature operating life duration. An exponential
(random) failure distribution is assumed, expressed in
units of FIT (failures per billion device hours) are only defined in the random failure portion of the reliability curve.
Table 1. Demonstrated Operating Life Test Performance
Stress Test
Condition
Total Device
Tested
Total Device
Hours
Number of
Failed Units
Demonstrated
MTTF(hr) @
Ta = +125 C
Demonstrated
FITs @
Ta = +125 C
Ta = 150 C
Vcc = 5.5V
Iin = 20mA
Io = 10mA
350
350,000
0
> 696,831
< 1,435
Table 2. Reliability Projection for Device Listed in Title
Ambient
Temperature
(C)
Junction
Temperature
(C)
Typical (60% Confidence)
90% Confidence
MTTF
(Hr/fail)
FITs
(Fail/109h)
MTTF
(Hr/fail)
FITs
(Fail/109h)
125
120
110
100
90
80
70
60
50
40
30
25
140
135
125
115
105
95
85
75
65
55
45
40
760,492
881,666
1,198,296
1,654,599
2,323,997
3,325,042
4,853,437
7,240,046
11,058,874
17,333,974
27,948,680
35,897,487
1,315
1,134
835
604
430
301
206
138
90
58
36
28
302,630
350,850
476,850
658,431
924,811
1,323,167
1,931,377
2,881,104
4,400,768
6,897,882
11,121,898
14,285,047
3,304
2,850
2,097
1,519
1,081
756
518
347
227
145
90
70
Table 3. Mechanical Tests (Testing done on a constructional basis)
Test Name
Reference Standard
Test Conditions
Units Tested
Units Failed
Temp Cycling
JESD-A104
-65 to 150 C
Transfer = 1 min, Dwell = 15 mins
1000 cycles
410
0
Physical Dimensions
JESD-B100
Conformance to datasheet package
drawings
30
0
Solderability
(Non RoHS condition)
JESD-B102
8hrs steam aging (93 C),
followed by solder dip (245 C,5sec)
10
0
Solderability
(RoHS condition)
JESD-B102
8hrs steam aging (93 C),
followed by solder dip (260 C,5sec)
10
0
Preconditioning
J-STD-020
JA113
As per reference standard
(to conform to MSL 1)
1228
0
Mechanical Vibration
Mil Std 883,
Method 2007
20G, 20-2000Hz,
10 min/cycle,
4times/direction
20
0
Table 4. Environmental Testing (Testing done on a constructional basis)
Test Name
Reference Standard
Test Conditions
Units Tested
Units Failed
Highly Accelerated
Stress Test
JESD-A110
Ta = 130 C, RH=85%
Vin=5V
Vo=Vcc=5.5V
Time = 96 hours
456
0
Unbiased Autoclave
JESD-A102
Ta = 121 C, RH = 100%
15psig
Unbiased
Time = 96 hours
231
0
High Temperature Bake
JESD-A103
Ta = 175°C
Unbiased
Time = 500 hours
90
0
For product information and a complete list of distributors, please go to our web site:
www.avagotech.com
Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies in the United States and other countries.
Data subject to change. Copyright © 2005-2012 Avago Technologies. All rights reserved.