ACPL-P480 and ACPL-W480
High CMR Intelligent Power Module and Gate Drive Interface Optocoupler
Data Sheet
Lead (Pb) Free
RoHS 6 fully
compliant
RoHS 6 fully compliant options available;
-xxxE denotes a lead-free product
Description
Features
The ACPL-P480 and ACPL-W480 fast speed optocouplers contain a GaAsP LED and photo detector with
built-in Schmitt trigger to provide logic-compatible
waveforms, eliminating the need for additional wave
shaping. The totem pole output eliminates the need for
a pull up resistor and allows for direct drive Intelligent
Power Module or gate drive. Minimized propagation
delay difference between devices make these optocouplers excellent solutions for improving inverter efficiency
through reduced switching dead time.
• Performance Specified for Common IPM Applications
Over Industrial Temperature Range.
• Short Maximum Propagation Delays
• Minimized Pulse Width Distortion (PWD)
• Very High Common Mode Rejection (CMR)
• Hysteresis
• Totem Pole Output (No Pull-up Resistor Required)
• Available in Stretched SO-6 package.
• Safety Approval:
UL Recognized with 3750 Vrms for 1 minute (5000
Vrms for 1 minute for all ACPL-W480 devices and
Option 020 device for ACPL-P480) per UL1577.
CSA Approved.
IEC/EN/DIN EN 60747-5-5 Approved:
VIORM = 891 Vpeak for ACPL-P480, and VIORM = 1140
Vpeak for ACPL-W480.
Functional Diagrams
ACPL-P480
ANODE 1
6 VCC
N.C. 2
5 VO
CATHODE 3
SHIELD
4 Ground
Specifications
ACPL-W480
ANODE 1
6 VCC
N.C. 2
5 VO
CATHODE 3
SHIELD
4 Ground
Note: A 0.1 µF bypass capacitor must be connected between pins 4 and 6.
Truth Table (Positive Logic)
LED
VO
ON
HIGH
OFF
LOW
•
•
•
•
•
•
Wide operating temperature range: –40°C to 100°C.
Maximum propagation delay tPHL / tPLH = 350 ns
Maximum Pulse Width Distortion (PWD) = 250 ns.
Propagation Delay Difference: Min. –100 ns, Max. 250 ns
Wide Operating VCC Range: 4.5 to 20 Volts
20 kV/µs minimum common mode rejection (CMR) at
VCM = 1000 V.
Applications
•
•
•
•
•
IPM Interface Isolation
Isolated IGBT/MOSFET Gate Drive
AC and Brushless DC Motor Drives
Industrial Inverters
General Digital Isolation
CAUTION: It is advised that normal static precautions be taken in handling and assembly
of this component to prevent damage and/or degradation which may be induced by ESD.
Ordering Information
ACPL-P480 is UL Recognized with 3750 Vrms for 1 minute and ACPL-W480 is UL Recognized with 5000 Vrms for 1
minute per UL1577. Both are approved under CSA Component Acceptance Notice #5, File CA 88324.
Option
Part number
RoHS
Compliant
Package
-000E
ACPL-P480
-520E
X
7mm
Stretched
SO-6
X
X
-560E
X
-500E
-060E
-560E
IEC/EN/DIN EN
60747-5-5
X
X
X
100 per reel
X
1000 per reel
X
100 per tube
X
1000 per reel
X
X
X
X
1000 per reel
X
X
X
8mm
Stretched
SO-6
Quantity
100 per tube
X
-060E
-000E
ACPL-W480
Tape & Reel
UL 1577
5000VRMS / 1
Minute Rating
X
-500E
-020E
Surface
Mount
X
100 per tube
X
1000 per reel
X
X
100 per tube
X
X
1000 per reel
To order, choose a part number from the part number column and combine with the desired option from the option
column to form an order entry.
Example 1:
ACPL-P480-560E to order product of Stretched SO-6 package in Tape and Reel packaging with IEC/EN/DIN EN
60747-5-5 Safety Approval in RoHS compliant.
Example 2:
ACPL-P480-000E to order product of Stretched SO-6 package in tube packaging and RoHS compliant.
Option datasheets are available. Contact your Avago sales representative or authorized distributor for information.
2
Package Outline Drawings
ACPL-P480 Stretched SO-6 Package, 7 mm clearance
+0.254
0
+0.010
0.180
- 0.000
1.27 BSG
0.050
0.381 ±0.127
0.015 ±0.005
4.580
1.27
0.050
7.62
0.300
6.81
0.268
0.45
0.018
45°
10.7
0.421
1.590 ±0.127
0.063 ±0.005
0.76
0.030
2.16
0.085
3.180 ±0.127
0.125 ±0.005
7°
7°
7°
7°
0.20 ±0.10
0.008 ±0.004
0.254 ±0.050
0.010 ±0.002
5 NOM.
1±0.250
0.040 ±0.010
Floating Lead Protusions max. 0.25 [0.01]
Dimensions in Millimeters [ Inches ]
Lead Coplanarity= 0.1mm [0.004 Inches ]
9.7 ±0.250
0.382 ±0.010
ACPL-W480 Stretched SO-6 Package, 8 mm clearance
0.381 ±0.127
0.015 ±0.005
1
4
7.62
[0.300]
+0.127
6.807
- 0.000
+0.005
0.268
- 0.000
7°
45°
7°
35° NOM.
11.500 ±0.25
0.453 ±0.010
1.905
0.075
1.270
0.050
1.590 ±0.127
0.063 ±0.005
0.20 ±0.10
0.008 ±0.004
3
0.760
0.030
5
3
0.750 ±0.250
[0.0295 ±0.010]
12.650
0.498
6
2
0.45
0.018
+0.254
0
+0.010
0.180
- 0.000
4.580
1.27 BSG
0.050
0.254 ±0.050
0.010 ±0.002
3.180 ±0.127
0.125 ±0.005
7°
7°
Floating Lead protusion max. 0.25[0.01]
Dimensions in millimeters [inches]
Lead Coplanarity=0.1 mm [0.004 inches]
Solder Reflow Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
Regulatory Information
The ACPL-P480 and ACPL-W480 are approved by the following organizations:
IEC/EN/DIN EN 60747-5-5 (Option 60 only)
UL
Approval under:
IEC 60747-5-5 : 2007
EN 60747-5-5 : 2011
DIN EN 60747-5-5 (VDE 0884-5) : 2011-11
ACPL-P480: Approval under UL 1577, component recognition program up to VISO = 3750 VRMS. File E55361.
CSA
Approval under CSA Component Acceptance Notice #5,
File CA 88324.
ACPL-W480 and ACPL-P480 (option 020): Approval under
UL 1577, component recognition program up to VISO =
5000 VRMS. File E55361.
Table 1. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060)
Characteristic
Description
Symbol
Installation classification per DIN VDE 0110/39, Table 1
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 450 Vrms
for rated mains voltage ≤ 600 Vrms
ACPL-P480
ACPL-W480
I - IV
I - III
I - III
I - IV
I - IV
I - IV
Climatic Classification
55/100/21
Pollution Degree (DIN VDE 0110/39)
Maximum Working Insulation Voltage
Unit
2
VIORM
891
1140
Vpeak
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial discharge < 5 pC
VPR
1670
2137
Vpeak
Input to Output Test Voltage, Method a*
VIORM x 1.6 = VPR, Type and Sample Test with tm = 10 sec,
Partial discharge < 5 pC
VPR
1426
1824
Vpeak
VIOTM
6000
8000
Vpeak
Highest Allowable Overvoltage (Transient Overvoltage tini = 60 sec)
Safety-limiting values - maximum values allowed in the event of a failure.
Case Temperature
Input Current
Output Power
Insulation Pesistance at TS, VIO = 500 V
TS
IS,INPUT
PS,OUTPUT
175
230
600
°C
mA
mW
RS
>109
W
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
DIN EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test profiles.
4
Table 2. Insulation and Safety Related Specifications
Parameter
Symbol
ACPL-P480
ACPL-W480
Units
Conditions
Minimum External Air Gap
(External Clearance)
L(101)
7.0
8.0
mm
Measured from input terminals to output
terminals shortest distance through air.
Minimum External Tracking
(External Creepage)
L(102)
8.0
8.0
mm
Measured from input terminals to output
terminals shortest distance path along body.
Minimum Internal Plastic Gap
(Internal Clearance)
0.08
mm
Through insulation distance conductor to
conductor, usually the straight line distance
thickness between the emitter and detector.
Minimum Internal Tracking
(Internal Creepage)
NA
mm
Measured from input terminals to output
tereminals, along internal cavity.
>175
V
Tracking Resistance
(Comparative Tracking Index)
CTI
Isolation Group
IIIa
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Table 3. Absolute Maximum Ratings
Parameter
Symbol
Min.
Max.
Units
Storage Temperature
TS
-55
125
°C
Operating Temperature
TA
-40
100
°C
Average Input Current
IF(avg)
10
mA
Peak Transient Input Current
(
很抱歉,暂时无法提供与“ACPL-W480-000E”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+36.706871+4.55347
- 10+25.0123210+3.10277
- 100+19.01756100+2.35912
- 500+16.64959500+2.06538
- 1000+15.921601000+1.97507
- 2000+15.324362000+1.90098
- 5000+14.703875000+1.82401