ACPL-W484-000E

  • 厂商:

    AVAGO(博通)

  • 封装:

    6-SOIC(0.268",6.80mm宽)

  • 描述:

    OPTOISO 5KV PUSH PULL 6SO

  • 数据手册
  • 价格&库存
ACPL-W484-000E 数据手册
ACPL-M484/P484/W484 Positive Logic High CMR Intelligent Power Module and Gate Drive Interface Optocoupler Data Sheet Description Features The ACPL-M484/P484/W484 fast speed optocoupler contains a AlGaAs LED and photo detector with built-in Schmitt trigger to provide logic-compatible waveforms, eliminating the need for additional wave shaping. The totem pole output eliminates the need for a pull up resistor and allows for direct drive Intelligent Power Module or gate drive. Minimized propagation delay difference between devices makes these optocouplers excellent solutions for improving inverter efficiency through reduced switching dead time. • Positive output type (totem pole output) • Truth Table Guaranteed: Vcc from 4.5 V to 30 V • Performance Specified for Common IPM Applications Over Industrial Temperature Range. • Short Maximum Propagation Delays • Minimized Pulse Width Distortion (PWD) • Very High Common Mode Rejection (CMR) • Hysteresis • Available in SO-5 (ACPL-M484) and Stretched SO-6 package (ACPCL-P484/W484). Applications • IPM Interface Isolation • Package Clearance/Creepage at 8 mm (ACPL-W484) • Isolated IGBT/MOSFET Gate Drive • Safety Approval: • AC and Brushless DC Motor Drives • Industrial Inverters – UL Recognized with 5000 Vrms (ACPL-W484) for 1 minute per UL1577. • General Digital Isolation – CSA Approved. Functional Diagram – IEC/EN/DIN EN 60747-5-5 Approved with VIORM = 567 Vpeak for ACPL-M484 and VIORM = 891 Vpeak for ACPL-P484 and VIORM = 1140 Vpeak for ACPL-W484, under option 060. ACPL-M484 Anode 1 6 VCC Note: A 0.1 µF bypass capacitor must be connected between pins 4 Ground Vcc and Ground. 5 VO Cathode 3 SHIELD Truth Table (Positive Logic) ACPL-P484 & ACPL-W484 Anode 1 6 VCC N.C. 2 5 VO Cathode 3 SHIELD 4 Ground LED VO ON OFF HIGH LOW Truth Table Guaranteed: Vcc from 4.5 V to 30 V Specifications • Wide operating temperature range: -40° C to 105° C • Maximum propagation delay tPHL / tPLH = 150/120 ns • Maximum Pulse Width Distortion (PWD) = 90 ns • Propagation Delay Difference Min/Max = -130/130 ns • Wide Operating VCC Range: 4.5 to 30 Volts • 30 kV/µs minimum common mode rejection (CMR) at VCM = 1000 V CAUTION: It is advised that normal static precautions be taken in handling and assembly of this component to prevent damage and/or degradation which may be induced by ESD. Ordering Information ACPL-M484/P484/W484 is UL recognized with 3750/3750/5000 Vrms/1 minute rating per UL 1577. Option Part number RoHS Compliant Package Surface Mount ACPL-M484 -000E SO-5 X -500E X -060E X -560E ACPL-P484 ACPL-W484 -000E -500E X Stretched SO-6 Tape & Reel IEC/EN/DIN EN 60747-5-5 100 per tube X X 1500 per reel X 100 per tube X 1500 per reel X X -060E X -560E X Quantity 100 per tube X X 1000 per reel X 100 per tube X 1000 per reel To order, choose a part number from the part number column and combine with the desired option from the option column to form an order entry. Example 1: ACPL-P484-560E to order product of Stretched SO-6 Surface Mount package in Tape and Reel packaging with IEC/EN/ DIN EN 60747-5-5 Safety Approval in RoHS compliant. Example 2: ACPL-P484-000E to order product of Stretched SO-6 Surface Mount package in Tube packaging and RoHS compliant. Example 3: ACPL-M484-000E to order product of SO-5 Surface Mount package in Tube packaging and RoHS compliant. Option datasheets are available. Contact your Avago sales representative or authorized distributor for information. 2 Package Outline Drawings ACPL-M484 SO-5 Package, 5 mm Creepage & Clearance ANODE 1 MXXX XXX 4.4 ± 0.1 (0.173 ± 0.004) 7.0 ± 0.2 (0.276 ± 0.008) CATHODE 3 6 VCC 5 VOUT 4 GND TYPE NUMBER (LAST 3 DIGITS) DATE CODE 0.4 ± 0.05 (0.016 ± 0.002) 3.6 ± 0.1* (0.142 ± 0.004) 0.102 ± 0.102 (0.004 ± 0.004) 2.5 ± 0.1 (0.098 ± 0.004) 0.15 ± 0.025 (0.006 ± 0.001) 7° MAX. 0.71 MIN (0.028) 1.27 BSC (0.050) MAX. LEAD COPLANARITY = 0.102 (0.004) Dimensions in millimeters (inches). * Maximum Mold flash on each side is 0.15 mm (0.006). Note: Foating Lead Protrusion is 0.15 mm (6 mils) max. Land Pattern Recommendation 4.4 (0.17) 1.3 (0.05) 2.5 (0.10) 2.0 (0.080) 0.64 (0.025) 8.27 (0.325) Dimension in millimeters (inches) 3 ACPL-P484 Stretched SO-6 Package, 7 mm clearance 4.580 + 0.254 0 1.27 (0.050) BSG 0.381 ±0.127 (0.015 ±0.005) Land Pattern Recommendation 10.7 (0.421) (0.180 + 0.010 0.000 ) 1.27 (0.050) 0.76 (0.030) 2.16 (0.085) 7.62 (0.300) 1.590 ±0.127 (0.063 ±0.005) 6.81 (0.268) 0.45 (0.018) 45° 3.180 ±0.127 (0.125 ±0.005) 7° 7° 7° 0.20 ±0.10 (0.008 ±0.004) 0.254 ±0.050 (0.010 ±0.002) 7° 5° NOM. 1 ±0.250 (0.040 ±0.010) Floating Lead Protusions max. 0.25 (0.01) Dimensions in Millimeters (Inches) 9.7 ±0.250 (0.382 ±0.010) Lead Coplanarity = 0.1 mm (0.004 Inches) ACPL-W484 Stretched SO-6 Package, 8 mm clearance Land Pattern Recommendation (W-type) 4.580 + 0.254 0 1.27 (0.050) BSG 0.381 ±0.127 (0.015 ±0.005) 1 6 2 5 3 4 7.62 (0.300) 6.807 + 0.127 0 (0.180 + 0.010 0.000 ) 12.650 (0.498) 0.760 (0.030) 1.905 (0.075) 1.270 (0.050) (0.268 + 0.005 0.000 ) 0.45 (0.018) 7° 45° 1.590 ±0.127 (0.063 ±0.005) 3.180 ±0.127 (0.125 ±0.005) 7° 0.20 ±0.10 (0.008 ±0.004) 0.750 ±0.250 (0.0295 ±0.010) 7° 35° NOM. 11.500 ±0.25 (0.453 ±0.010) 4 7° 0.254 ±0.050 (0.010 ±0.002) Floating Lead Protusions max. 0.25 (0.01) Dimensions in Millimeters (Inches) Lead Coplanarity = 0.1 mm (0.004 Inches) Recommended Pb-Free IR Profile Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used. Regulatory Information The ACPL-M484/P484/W484 is approved by the following organizations: IEC/EN/DIN EN 60747-5-5 (Option 060 only) Approved with Maximum Working Insulation Voltage VIORM = 567 Vpeak for ACPL-M484, VIORM = 891 Vpeak for ACPL-P484 and VIORM = 1140 Vpeak for ACPL-W484 UL Approval under UL 1577, component recognition program up to VISO = 3750 VRMS File E55361 for ACPL-M484 & ACPLP484; Approval under UL 1577, component recognition program up to VISO = 5000 VRMS File E55361 for ACPL-W484; CSA Approval under CSA Component Acceptance Notice #5, File CA 88324. Table 1. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (ACPL-M484/P484/W484 Option 060) Description Symbol ACPL-M484 ACPL-P484 ACPL-W484 Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage ≤ 150 Vrms for rated mains voltage ≤ 300 Vrms for rated mains voltage ≤ 600 Vrms I – IV I – III I – II I – IV I – III I – II I – IV I – III I – II Climatic Classification 55/105/21 55/105/21 55/105/21 Pollution Degree (DIN VDE 0110/1.89) 2 2 2 Unit Maximum Working Insulation Voltage VIORM 567 891 1140 Vpeak Input to Output Test Voltage, Method b* VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec, Partial discharge < 5 pC VPR 1063 1670 2137 Vpeak Input to Output Test Voltage, Method a* VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec, Partial discharge < 5 pC VPR 907 1426 1824 Vpeak Highest Allowable Overvoltage (Transient Overvoltage tini = 60 sec) VIOTM 6000 6000 8000 Vpeak Safety-limiting values – maximum values allowed in the event of a failure. Case Temperature Input Current Output Power TS IS, INPUT PS, OUTPUT 175 230 600 175 230 600 175 230 600 °C mA mW Insulation Resistance at TS, VIO = 500 V RS >109 >109 >109 Ω * Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/ DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles. 5 Table 2. Insulation and Safety Related Specifications Parameter Symbol ACPL-M484 ACPL-P484 ACPL-W484 Units Conditions Minimum External Air Gap (External Clearance) L(101) 5.0 7.0 8.0 mm Measured from input terminals to output terminals, shortest distance through air. Minimum External Tracking (External Creepage) L(102) 5.0 8.0 8.0 mm Measured from input terminals to output terminals, shortest distance path along body. 0.08 0.08 0.08 mm Through insulation distance conductor to conductor, usually the straight line distance thickness between the emitter and detector. >175 >175 >175 V DIN IEC 112/VDE 0303 Part 1 IIIa IIIa IIIa Minimum Internal Plastic Gap (Internal Clearance) Tracking Resistance (Comparative Tracking Index) CTI Isolation Group Material Group (DIN VDE 0110, 1/89, Table 1) Table 3. Absolute Maximum Ratings Parameter Symbol Min. Max. Units Note Storage Temperature TS -55 125 °C Operating Temperature TA -40 105 °C Average Input Current IF(avg) 10 mA Peak Transient Input Current (
ACPL-W484-000E 价格&库存

很抱歉,暂时无法提供与“ACPL-W484-000E”相匹配的价格&库存,您可以联系我们找货

免费人工找货
ACPL-W484-000E
  •  国内价格 香港价格
  • 1+38.107101+4.72717
  • 10+26.0339810+3.22951
  • 100+19.84608100+2.46190
  • 500+17.40395500+2.15896
  • 1000+16.652991000+2.06580
  • 2000+16.037182000+1.98941
  • 5000+15.435785000+1.91481

库存:1851