ACPL-M484/P484/W484
Positive Logic High CMR Intelligent Power Module
and Gate Drive Interface Optocoupler
Data Sheet
Description
Features
The ACPL-M484/P484/W484 fast speed optocoupler contains a AlGaAs LED and photo detector with built-in Schmitt
trigger to provide logic-compatible waveforms, eliminating the need for additional wave shaping. The totem
pole output eliminates the need for a pull up resistor and
allows for direct drive Intelligent Power Module or gate
drive. Minimized propagation delay difference between
devices makes these optocouplers excellent solutions for
improving inverter efficiency through reduced switching
dead time.
• Positive output type (totem pole output)
• Truth Table Guaranteed: Vcc from 4.5 V to 30 V
• Performance Specified for Common IPM Applications
Over Industrial Temperature Range.
• Short Maximum Propagation Delays
• Minimized Pulse Width Distortion (PWD)
• Very High Common Mode Rejection (CMR)
• Hysteresis
• Available in SO-5 (ACPL-M484) and Stretched SO-6
package (ACPCL-P484/W484).
Applications
• IPM Interface Isolation
• Package Clearance/Creepage at 8 mm (ACPL-W484)
• Isolated IGBT/MOSFET Gate Drive
• Safety Approval:
• AC and Brushless DC Motor Drives
• Industrial Inverters
– UL Recognized with 5000 Vrms (ACPL-W484) for
1 minute per UL1577.
• General Digital Isolation
– CSA Approved.
Functional Diagram
– IEC/EN/DIN EN 60747-5-5 Approved with VIORM =
567 Vpeak for ACPL-M484 and VIORM = 891 Vpeak for
ACPL-P484 and VIORM = 1140 Vpeak for ACPL-W484,
under option 060.
ACPL-M484
Anode 1
6 VCC
Note: A 0.1 µF bypass
capacitor must be connected between pins
4 Ground Vcc and Ground.
5 VO
Cathode 3
SHIELD
Truth Table
(Positive Logic)
ACPL-P484 & ACPL-W484
Anode 1
6 VCC
N.C. 2
5 VO
Cathode 3
SHIELD
4 Ground
LED
VO
ON
OFF
HIGH
LOW
Truth Table Guaranteed:
Vcc from 4.5 V to 30 V
Specifications
• Wide operating temperature range: -40° C to 105° C
• Maximum propagation delay tPHL / tPLH = 150/120 ns
• Maximum Pulse Width Distortion (PWD) = 90 ns
• Propagation Delay Difference Min/Max = -130/130 ns
• Wide Operating VCC Range: 4.5 to 30 Volts
• 30 kV/µs minimum common mode rejection (CMR) at
VCM = 1000 V
CAUTION: It is advised that normal static precautions be taken in handling and assembly
of this component to prevent damage and/or degradation which may be induced by ESD.
Ordering Information
ACPL-M484/P484/W484 is UL recognized with 3750/3750/5000 Vrms/1 minute rating per UL 1577.
Option
Part number
RoHS Compliant
Package
Surface Mount
ACPL-M484
-000E
SO-5
X
-500E
X
-060E
X
-560E
ACPL-P484
ACPL-W484
-000E
-500E
X
Stretched
SO-6
Tape & Reel
IEC/EN/DIN
EN 60747-5-5
100 per tube
X
X
1500 per reel
X
100 per tube
X
1500 per reel
X
X
-060E
X
-560E
X
Quantity
100 per tube
X
X
1000 per reel
X
100 per tube
X
1000 per reel
To order, choose a part number from the part number column and combine with the desired option from the option
column to form an order entry.
Example 1:
ACPL-P484-560E to order product of Stretched SO-6 Surface Mount package in Tape and Reel packaging with IEC/EN/
DIN EN 60747-5-5 Safety Approval in RoHS compliant.
Example 2:
ACPL-P484-000E to order product of Stretched SO-6 Surface Mount package in Tube packaging and RoHS compliant.
Example 3:
ACPL-M484-000E to order product of SO-5 Surface Mount package in Tube packaging and RoHS compliant.
Option datasheets are available. Contact your Avago sales representative or authorized distributor for information.
2
Package Outline Drawings
ACPL-M484 SO-5 Package, 5 mm Creepage & Clearance
ANODE 1
MXXX
XXX
4.4 ± 0.1
(0.173 ± 0.004)
7.0 ± 0.2
(0.276 ± 0.008)
CATHODE 3
6
VCC
5
VOUT
4
GND
TYPE NUMBER (LAST 3 DIGITS)
DATE CODE
0.4 ± 0.05
(0.016 ± 0.002)
3.6 ± 0.1*
(0.142 ± 0.004)
0.102 ± 0.102
(0.004 ± 0.004)
2.5 ± 0.1
(0.098 ± 0.004)
0.15 ± 0.025
(0.006 ± 0.001)
7° MAX.
0.71 MIN
(0.028)
1.27 BSC
(0.050)
MAX. LEAD COPLANARITY
= 0.102 (0.004)
Dimensions in millimeters (inches).
* Maximum Mold flash on each side is 0.15 mm (0.006).
Note: Foating Lead Protrusion is 0.15 mm (6 mils) max.
Land Pattern Recommendation
4.4
(0.17)
1.3
(0.05)
2.5
(0.10)
2.0
(0.080)
0.64
(0.025)
8.27
(0.325)
Dimension in millimeters (inches)
3
ACPL-P484 Stretched SO-6 Package, 7 mm clearance
4.580 + 0.254
0
1.27 (0.050) BSG
0.381 ±0.127
(0.015 ±0.005)
Land Pattern Recommendation
10.7 (0.421)
(0.180 + 0.010
0.000 )
1.27 (0.050)
0.76 (0.030)
2.16 (0.085)
7.62 (0.300)
1.590 ±0.127
(0.063 ±0.005)
6.81 (0.268)
0.45 (0.018)
45°
3.180 ±0.127
(0.125 ±0.005)
7°
7°
7°
0.20 ±0.10
(0.008 ±0.004)
0.254 ±0.050
(0.010 ±0.002)
7°
5° NOM.
1 ±0.250
(0.040 ±0.010)
Floating Lead Protusions max. 0.25 (0.01)
Dimensions in Millimeters (Inches)
9.7 ±0.250
(0.382 ±0.010)
Lead Coplanarity = 0.1 mm (0.004 Inches)
ACPL-W484 Stretched SO-6 Package, 8 mm clearance
Land Pattern Recommendation (W-type)
4.580 + 0.254
0
1.27 (0.050) BSG
0.381 ±0.127
(0.015 ±0.005)
1
6
2
5
3
4
7.62 (0.300)
6.807 + 0.127
0
(0.180 + 0.010
0.000 )
12.650 (0.498)
0.760 (0.030)
1.905 (0.075)
1.270 (0.050)
(0.268 + 0.005
0.000 )
0.45 (0.018)
7°
45°
1.590 ±0.127
(0.063 ±0.005)
3.180 ±0.127
(0.125 ±0.005)
7°
0.20 ±0.10
(0.008 ±0.004)
0.750 ±0.250
(0.0295 ±0.010)
7°
35° NOM.
11.500 ±0.25
(0.453 ±0.010)
4
7°
0.254 ±0.050
(0.010 ±0.002)
Floating Lead Protusions max. 0.25 (0.01)
Dimensions in Millimeters (Inches)
Lead Coplanarity = 0.1 mm (0.004 Inches)
Recommended Pb-Free IR Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
Regulatory Information
The ACPL-M484/P484/W484 is approved by the following organizations:
IEC/EN/DIN EN 60747-5-5 (Option 060 only)
Approved with Maximum Working Insulation Voltage VIORM = 567 Vpeak for ACPL-M484, VIORM = 891 Vpeak for ACPL-P484
and VIORM = 1140 Vpeak for ACPL-W484
UL
Approval under UL 1577, component recognition program up to VISO = 3750 VRMS File E55361 for ACPL-M484 & ACPLP484;
Approval under UL 1577, component recognition program up to VISO = 5000 VRMS File E55361 for ACPL-W484;
CSA
Approval under CSA Component Acceptance Notice #5, File CA 88324.
Table 1. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (ACPL-M484/P484/W484 Option 060)
Description
Symbol
ACPL-M484
ACPL-P484
ACPL-W484
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
I – IV
I – III
I – II
I – IV
I – III
I – II
I – IV
I – III
I – II
Climatic Classification
55/105/21
55/105/21
55/105/21
Pollution Degree (DIN VDE 0110/1.89)
2
2
2
Unit
Maximum Working Insulation Voltage
VIORM
567
891
1140
Vpeak
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial discharge < 5 pC
VPR
1063
1670
2137
Vpeak
Input to Output Test Voltage, Method a*
VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec,
Partial discharge < 5 pC
VPR
907
1426
1824
Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage tini = 60 sec)
VIOTM
6000
6000
8000
Vpeak
Safety-limiting values – maximum values allowed in
the event of a failure.
Case Temperature
Input Current
Output Power
TS
IS, INPUT
PS, OUTPUT
175
230
600
175
230
600
175
230
600
°C
mA
mW
Insulation Resistance at TS, VIO = 500 V
RS
>109
>109
>109
Ω
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
5
Table 2. Insulation and Safety Related Specifications
Parameter
Symbol
ACPL-M484 ACPL-P484
ACPL-W484 Units
Conditions
Minimum External Air Gap
(External Clearance)
L(101)
5.0
7.0
8.0
mm
Measured from input terminals to
output terminals, shortest distance
through air.
Minimum External Tracking
(External Creepage)
L(102)
5.0
8.0
8.0
mm
Measured from input terminals to
output terminals, shortest distance
path along body.
0.08
0.08
0.08
mm
Through insulation distance conductor
to conductor, usually the straight line
distance thickness between the
emitter and detector.
>175
>175
>175
V
DIN IEC 112/VDE 0303 Part 1
IIIa
IIIa
IIIa
Minimum Internal Plastic Gap
(Internal Clearance)
Tracking Resistance
(Comparative Tracking Index)
CTI
Isolation Group
Material Group (DIN VDE 0110, 1/89,
Table 1)
Table 3. Absolute Maximum Ratings
Parameter
Symbol
Min.
Max.
Units
Note
Storage Temperature
TS
-55
125
°C
Operating Temperature
TA
-40
105
°C
Average Input Current
IF(avg)
10
mA
Peak Transient Input Current
(
很抱歉,暂时无法提供与“ACPL-W484-000E”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+38.107101+4.72717
- 10+26.0339810+3.22951
- 100+19.84608100+2.46190
- 500+17.40395500+2.15896
- 1000+16.652991000+2.06580
- 2000+16.037182000+1.98941
- 5000+15.435785000+1.91481
- 国内价格
- 26+29.73672
- 50+29.09626