0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
APDS-9007

APDS-9007

  • 厂商:

    AVAGO(博通)

  • 封装:

  • 描述:

    APDS-9007 - Ambient Light Photo Sensor with Logarithmic Current Output - AVAGO TECHNOLOGIES LIMITED

  • 数据手册
  • 价格&库存
APDS-9007 数据手册
APDS-9007 Ambient Light Photo Sensor with Logarithmic Current Output Data Sheet Description The APDS-9007 is an analog current output Ambient Light Photo Sensor, packaged in a miniature chipLED lead-free surface mount package. This device provides a Logarithmic response over a wide dynamic range of 3 lux to 70K lux and has a low sensitivity variation across various light sources. It is well suited for applications that operates under high ambient brightness. Features • Excellent responsivity Close responsivity to the human eye • Miniature ChipLED Leadfree surface-mount package Height – 0.8 mm Length – 2.4 mm Width – 2.0 mm • Low sensitivity variation across various light sources • Operating temperature : -40°C to 85°C • Vcc supply 2 to 3.6V • Lead-free package with RoHS compliance • Photo current response to wide dynamic range of 3 lux to 70K lux Application Support Information The Application Engineering Group is available to assist you with the application design associated with APDS9007 ambient light photo sensor module. You can contact them through your local sales representatives for additional details. Applications • Detection of ambient light to control display backlighting Mobile devices – Mobile phones, PDAs Computing devices – Notebooks, Webpads Consumer devices – TVs, Video Cameras, Digital Still Camera • Automatic Residential and Commercial Lighting Management • Electronic Signs and Signals Ordering Information Part Number APDS-9007-00 Packaging Type Tape and Reel Package 6-pins Chipled package Quantity 500 Typical Application Circuit Pin 4: VCC I/O Pins Configuration Table Pin 1 Pin 3: OUT Symbol Gnd NC * Out Vcc NC * SD Description Ground No Connect Output Supply Voltage No Connect Shutdown (Active High) Pin 6: SD APDS9007  3 4 RLoad Pin 1: GND 5 6 GND GND Figure 1. Typical application circuit for APDS-9007 (RLoad = 27 K Ohm) Absolute Maximum Ratings For implementations where case to ambient thermal resistance is ± 50 °C /W Parameter Storage Temperature Supply Voltage Symbol TS VCC Min. -40 0 Max. 85 3.6 Units °C V Recommended Operating Conditions Parameter Operating Temperature Supply Voltage Symbol TA VCC Min. -40  Max. 85 3.6 Units °C V Conditions CAUTION: It is advised that normal static precautions be taken in handling and assembly of this component to prevent damage and/or degradation which may be induced by ESD  Electrical & Optical Specifications (Ta=25C) : Parameter Supply Current Photo Current output (I) Photo Current output (II) Light Current Ratio Rise Time Fall Time Peak sensitivity wavelength SD Current Output Compliance Voltage Symbol Icc I_PH1 I_PH I_PH / I_PH1 Tr Tf l Icc-SD Vout Vcc-0.5 1 Min. Typ. 30 30 36 1. 0. 0. 560 1 mSec mSec nm µA Volts Vcc=3V, SD=3V RLoad=100K, Vcc=3V (Refer Figure 7) Rload = 7K ohms, 1K lux,Vcc = 3V Rload = 7K ohms, 1K lux, Vcc = 3V 39 Max. Units µA uA Conditions LUX=1K, Vcc=3V Lux=1K, Vcc=3V (Note 1,3) Lux=1K, Vcc=3V (Note ,3) Notes : 1. White LED is used as light source 2. Illuminance by incandescent lamp 3. Photo Current (I out) = 10uA x Log (Lux) Functional Block Diagram VCC Log Fn V2I & Mirror Temperature Compensation OUT GND Light Measurement Circuit and Waveforms I-Pulse Pin 4: VCC Pin 3: OUT APDS-9007 R Load VOUT 90% 10% GND GND GND GND Tr Tf I-Pulse Load LED Pin 1: GND 3 1 Eye Response Relative output response 0.8 APDS-9007 0.6 0.4 0.2 0 300 500 700 Wavelength in nm 900 1100 -90 -75 -60 -45 -30 1.1 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 -15 0 Relative response 15 30 45 60 75 90 Angle in Degrees Figure 1. Spectral Response Figure 2. Angular Response plot 50.0E-6 45.0E-6 40.0E-6 35.0E-6 30.0E-6 25.0E-6 20.0E-6 15.0E-6 10.0E-6 5.0E-6 000.0E+0 1 10 100 LUX 1000 10000 100000 2.0 1.5 Rel IOUT 1.0 0.5 0.0 2 2.5 3 Supply Voltage 3.5 4 Avg IOUT Figure 3. Average Iout vs Lux ,T=25°C Figure 4. Relative Iout Vs Vcc @ 1K LUX , T=25°C 1.10 1.00 Avg REL IOUT Supply Current 250.0E-6 200.0E-6 150.0E-6 100.0E-6 50.0E-6 000.0E+0 10 TEMP 60 110 2 2.5 3 Supply Voltage in Volts 3.5 4 0.90 0.80 0.70 0.60 0.50 -40 Figure 5. Relative Iout Vs Temperature Figure 6. Icc Vs Vcc, T=25°C 4 3500 3000 2500 Avg V-out [mV] Tr 2000 1500 1000 500 0 1 10 100 LUX 1000 10000 100000 200.0E-6 160.0E-6 120.0E-6 80.0E-6 40.0E-6 000.0E+0 0 10000 20000 LOAD 30000 40000 Figure 7. Output Compliance Voltage plot Figure 8. Rise Time Vs RLoad (Ohm) 160.8E-6 Tf 120.8E-6 80.8E-6 40.8E-6 800.0E-9 0 10000 20000 LOAD 30000 40000 Figure 9. Fall Time Vs RLoad(Ohm) 3.000 2.500 2.000 Vout (V) 1.500 1.000 0.500 0.000 1 10 100 Lux 1000 10000 100000 Rload = 10kohm Rload = 15kohm Rload = 27kohm Rload = 36kohm Rload = 56kohm Rload = 75kohm Figure 10. Average Vout vs Lux 5 APDS-9007 Package Outline Note: Active Area : Center of the device 6 APDS-9007 Tape and Reel Dimension 7 Moisture Proof Packaging UNITS IN A SEALED MOISTURE-PROOF PACKAGE PACKAGE IS OPENED (UNSEALED) PARTS ARE NOT RECOMMENDED TO BE USED NO ENVIRONMENT LESS THAN 30 C AND LESS THAN 60%RH YES PACKAGE IS OPENED LESS THAN 168 HOURS YES NO BAKING IS NECESSARY NO NO PACKAGE IS OPENED LESS THAN 15 DAYS YES PERFORM RECOMMENDED BAKING CONDITIONS All APDS-9007 options are shipped in moisture proof package. Once opened, moisture absorption begins. This part is compliant to JEDEC Level 3. Recommended Storage Conditions: Storage Temperature Relative Humidity 10°C to 30°C below 60% RH Baking Conditions: Package In Reel In Bulk Temperature 60°C 100°C Time 48 hours 6 hours Time from unsealing to soldering: After removal from the bag, the parts should be soldered within 168 hours if stored at the recommended storage conditions. If times longer than 168 hours are needed, the parts must be stored in a dry box. * Baking should only be done once. 8 Recommended Reflow Profile 255 T - TEMPERATURE (˚C) MAX 260C R3 R4 230 217 200 180 150 120 80 25 0 P1 HEAT UP 50 R1 R2 60 sec to 90 sec Above 217 C R5 100 P2 SOLDER PASTE DRY 150 200 P3 SOLDER REFLOW 250 P4 COOL DOWN 300 t-TIME (SECONDS) Process Zone Heat Up Solder Paste Dry Solder Reflow Cool Down Time maintained above liquidus point , 17°C Peak Temperature Time within 5°C of actual Peak Temperature Time 5°C to Peak Temperature Symbol P1, R1 P, R P3, R3 P3, R4 P4, R5 DT 5°C to 150°C 150°C to 00°C 00°C to 60°C 60°C to 00°C 00°C to 5°C > 17°C 60°C >55°C 5°C to 60°C Maximum DT/Dtime or Duration 3°C/s 100s to 180s 3°C/s -6°C/s -6°C/s 60s to 90s 0s to 40s 8mins The reflow profile is a straight-line representation of a nominal temperature profile for a convective reflow solder process. The temperature profile is divided into four process zones, each with different DT/Dtime temperature change rates or duration. The DT/Dtime rates or duration are detailed in the above table. The temperatures are measured at the component to printed circuit board connections. In process zone P1, the PC board and component pins are heated to a temperature of 150°C to activate the flux in the solder paste. The temperature ramp up rate, R1, is limited to 3°C per second to allow for even heating of both the PC board and component pins. Process zone P2 should be of sufficient time duration (100 to 180 seconds) to dry the solder paste. The temperature is raised to a level just below the liquidus point of the solder. Process zone P3 is the solder reflow zone. In zone P3, the temperature is quickly raised above the liquidus point of solder to 260°C (500°F) for optimum results. The dwell time above the liquidus point of solder should be between 60 and 90 seconds. This is to assure proper coalescing of the solder paste into liquid solder and the formation of good solder connections. Beyond the recommended dwell time the intermetallic growth within the solder connections becomes excessive, resulting in the formation of weak and unreliable connections. The temperature is then rapidly reduced to a point below the solidus temperature of the solder to allow the solder within the connections to freeze solid. Process zone P4 is the cool down after solder freeze. The cool down rate, R5, from the liquidus point of the solder to 25°C (77°F) should not exceed 6°C per second maximum. This limitation is necessary to allow the PC board and component pins to change dimensions evenly, putting minimal stresses on the component. It is recommended to perform reflow soldering no more than twice. 9 Appendix A: SMT Assembly Application Note 1.0 Solder Pad, Mask and Metal Stencil Aperture Stencil Aperture Metal Stencil For Solder Paste Printing Land Pattern PCBA 1.3 Adjacent Land Keepout and Solder Mask Areas Adjacent land keep-out is the maximum space occupied by the unit relative to the land pattern. There should be no other SMD components within this area. The minimum solder resist strip width required to avoid solder bridging adjacent pads is 0.2 mm. Note: Wet/Liquid Photo-Imageable solder resist/mask is recommended. 3.2 Solder Mask Figure A1. Stencil and PCBA 1.1 Recommended Land Pattern 0.9 0.8 Mounting Center 0.3 0.6 2.2 0.7 0.9 Mounting Center 4.2 Unit: mm 0.2 MIN. 0.8 Unit: mm 1.4 3.2 Figure A4. Adjacent Land Keepout and Solder Mask Areas Figure A2. Recommended Land Pattern 1.2 Recommended Metal Solder Stencil Aperture It is recommended that a 0.11 mm (0.004 inches) thick stencil be used for solder paste printing. Aperture opening for shield pad is 0.9mm x 0.8mm (as per land pattern). This is to ensure adequate printed solder paste volume and no shorting. Aperture Opening 0.1 1 2.2 3.2 Unit: mm Figure A3. Solder Stencil Aperture 10 Appendix B: Optical Window Design for APDS-9007 1.0 Optical Window Dimensions To ensure that the performance of the APDS-9007 will not be affected by improper window design, there are some constraints on the dimensions and design of the window. There is a constraint on the minimum size of the window, which is placed in front of the photo light sensor, so that it will not affect the angular response of the APDS-9007. This minimum dimension that is recommended will ensure at least a ±35° light reception cone. If a smaller window is required, a light pipe or light guide can be used. A light pipe or light guide is a cylindrical piece of transparent plastic, which makes use of total internal reflection to focus the light. The thickness of the window should be kept as minimum as possible because there is a loss of power in every optical window of about 8% due to reflection (4% on each side) and an additional loss of energy in the plastic material. Figure B1 and B2 illustrate the two types of window that we have recommended which could either be a flat window or a flat window with light pipe. Table 1 and Figure B3 below show the recommended dimensions of the window. These dimension values are based on a window thickness of 1.0mm with a refractive index 1.585. Table 1. Recommended minimum dimension for optical window. All dimensions are in mm WD (T+L+Z) 1.5 .0 .5 3.0 Flat Window (L=0.0) Z 0.5 1.0 1.5 .0 D1 .15 .85 3.55 4.5 Flat window with Light Pipe D1/D2 .0/1. T/L/Z 1.0/1.5/0.5 The window should be placed directly on top of the light receiving area (active area) of the photo sensor to achieve better performance and if a flat window with a light pipe is used, dimension D2 should be 1.5mm to optimize the performance of APDS-9007. The recommended minimum window dimension is based on the assumption that the center of the window and the center of the light receiving of the photo sensor are the same. It is recommended that the tolerance for assembly be considered as well. The recommended minimum window size which will take into account of the assembly tolerance is defined as: D1 (min + assembly tolerance) = D1min + 2*(assembly tolerance) (Dimensions are in mm) D2 (min + assembly tolerance) = D2min + 2*(assembly tolerance) (Dimensions are in mm) D1 Top View T Figure B1. Window Size Determination for Flat Window WD L D2 D1 Z APDS-9007 Light Receving Area WD: D1: T: L: D2: Z: Working Distance between window front panel & APDS-9007 Window Diameter Thickness Length of Light Pipe Light Pipe Diameter Distance between window rear panel and APDS-9007 Figure B2. Window Design of Flat Window with Light Guide Figure B3 .Recommended Window Dimensions 11 2.1 Optical Window Material The material of the window is recommended to be polycarbonate. The surface finish of the plastic should be smooth, without any texture. The recommended plastic material for use as a window is available from Bayer AG and Bayer Antwerp N. V. (Europe), Bayer Corp.(USA) and Bayer Polymers Co., Ltd. (Thailand), as shown in Table 2. Table 2. Recommended Plastic Materials Material number Makrolon LQ647 Makrolon LQ3147 Makrolon LQ3187 Visible light transmission 87% 87% 85% Refractive index 1.587 1.587 1.587 1 Appendix C: General Application Guide for APDS-9007 The APDS-9007 is an analog current output ambient light photo sensor whose spectral response is close to the CIE standard photopic observer. APDS-9007 consists of a photodiode and an IC that performs amplification of the photodiode output signal and conversion to a logarithmic output current. APDS-9007 is able to produce a high gain photo current that can be converted to an output voltage via a standard value external load resistor. APDS-9007 is then easily integrated into micro-controller that has an available A/D as shown in Figure C1 below. The magnitude of the output voltage, Vout is directly proportional to the photo current which is generated by the brightness of the light source shone on the photo sensor and the value of the load resistor used, RL. Increasing the brightness of the light source and/or the value of the load resistor will increase the magnitude of the output voltage. The unit used to measure light in terms of what our eyes perceive is “LUX”. It indicates the intensity to which a surface is lit or the brightness of the light. Light sources with the same LUX level appear at the same brightness to the human eyes. The equipment for “LUX” measurement is a lux meter. Selection of the load resistor RL will determine the amount of current-to-voltage conversion in the circuit. APDS-9007 allows a maximum saturation output voltage of (Vcc – 0.5V). Artificial light sources such as fluorescent lamps or incandescent lamps produced ac noise with a frequency of 50/60Hz and 100Hz respectively. A capacitor of 10uF, which acts as a low-pass filter, is recommended to be added in parallel with the load resistor to filter out these interferences. An analog logarithmic current output is able to represent the wide dynamic range of ambient light brightness level from near darkness environment to bright outdoor conditions correctly and accurately. For a logarithmic output, constant relative changes in the input values are converted to constant absolute changes in the output values. A logarithmic current output is advantageous because when measuring low brightness levels, small changes in those levels need to be detected. For example, a change from 100lux to 200lux needs to be detected. On the other hand, when measuring high brightness levels, only relatively large changes need to be detected. For example, a change from 10000lux to 10200lux can be negligible and a change from 10klux to 20klux needs to be detected instead. Hence APDS-9007, with a logarithmic current output, is able to provide a good relative resolution over the entire ambient light brightness range. It is able to measure small current steps at low brightness levels and yet, at high brightness levels, it is not required to measure the current at such fine absolute resolutions. This is illustrated in Figure C2 below. A change from 10lux to 100lux and a change from 1klux to 10klux will both give a same relative change which is 10. This is equivalent to a constant absolute change in output current which is 10uA for both changes. Hence a change from 10lux to 100lux will result in a change of 10uA. Similarly, a change from 1klux to 10klux will also result in a change of 10uA. APDS-9007 can be directly connected to the A/D of the micro-controller via one external load resistor which will give the same accuracy or resolution over a wide dynamic range. 45 Output Current (uA) 40 35 30 25 20 15 10 5 0 1 10 100 Lux 1000 10000 I2 = 40uA �"I = I2 - I1 I1 = 30uA I2 = 20uA �"I = I2 - I1 I1 = 10uA Pin 4: VDD Light Source APDS9007 RL MicroController A/D C Pin 3 : OUT Pin 6: ShutDown (Active High) Pin 1:� GND GND Ev2 = 100lux Ev1 = 10lux �"Ev = Ev2/Ev1 = 10 Ev1 = 1klux Ev2 = 10klux �"Ev = Ev2/Ev1 = 10 Figure C1. Configuration of APDS-9007 Figure C2. Feature of Logarithmic Output 13 For product information and a complete list of distributors, please go to our web site: www.avagotech.com Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies, Limited in the United States and other countries. Data subject to change. Copyright © 007 Avago Technologies Limited. All rights reserved. AV0-051EN - June 8, 007
APDS-9007 价格&库存

很抱歉,暂时无法提供与“APDS-9007”相匹配的价格&库存,您可以联系我们找货

免费人工找货