Agilent T-13/4 (5 mm) Precision Optical
Performance AlInGaP LED Lamps
Data Sheet
SunPower Series
HLMP-ELxx HLMP-EHxx
HLMP-EJxx HLMP-EGxx
Description
These Precision Optical Performance AlInGaP LEDs provide
superior light output for
excellent readability in sunlight
and are extremely reliable.
AlInGaP LED technology
provides extremely stable light
output over long periods of time.
Precision Optical Performance
lamps utilize the aluminum
indium gallium phosphide
(AlInGaP) technology.
These LED lamps are untinted,
nondiffused, T-13 /4 packages
incorporating second generation
optics producing well defined
spatial radiation patterns at
specific viewing cone angles.
These lamps are made with an
advanced optical grade epoxy,
offering superior high temperature and high moisture
resistance performance in
outdoor signal and sign
applications. The high maximum
LED junction temperature limit
of +130°C enables high
temperature operation in bright
sunlight conditions. The package
epoxy contains both uv-a and
uv-b inhibitors to reduce the
effects of long term exposure to
direct sunlight.
These lamps are available in two
package options to give the
designer flexibility with device
mounting.
Features
• Well Defined Spatial Radiation
Patterns
• Viewing Angles: 6°, 15°, 23°, 30°
• High Luminous Output
• Colors:
590 nm Amber
605 nm Orange
615 nm Reddish-Orange
626 nm Red
• High Operating Temperature:
T J LED = +130°C
• Superior Resistance to Moisture
• Package Options:
With or Without Lead Stand-Offs
Benefits
• Viewing Angles Match Traffic
Management Sign Requirements
• Colors Meet Automotive and
Pedestrian Signal Specifications
• Superior Performance in Outdoor
Environments
• Suitable for Autoinsertion onto PC
Boards
Applications
• Traffic Management:
Traffic Signals
Pedestrian Signals
Work Zone Warning Lights
Variable Message Signs
• Commercial Outdoor Advertising:
Signs
Marquees
• Automotive:
Exterior and Interior Lights
Device Selection Guide
Typical
Viewing Angle
2θ 1/2 (Deg.)[4]
Color and Dominant
Wavelength
(nm), Typ.[3]
Lamps Without
Standoffs on Leads
(Outline Drawing A)
HLMP-EL08-VY000
Lamps With Standoffs
on Leads
(Outline Drawing B)
HLMP-EL10-VY000
HLMP-EL08-VYK00*
HLMP-EL08-VXK00*
HLMP-EL08-VX400**
Amber 590
HLMP-EL08-VX000
HLMP-EL08-WZ000
HLMP-EL08-XZ400**
HLMP-EL08-XZ000
HLMP-EL10-WZ000
HLMP-EL08-XZK00*
HLMP-EL08-XY000
HLMP-EL08-XYK00*
4200
4200
4200
12000
9300
9300
4200
5500
7200
7200
9300
16000
16000
16000
7200
7200
7200
16000
12000
12000
HLMP-EL08-X1K00*
HLMP-EL08-X1000
HLMP-EJ08-WZ000
HLMP-EL10-X1000
HLMP-EJ10-WZ000
7200
7200
5500
21000
21000
16000
Orange 605
HLMP-EJ08-X1000
HLMP-EJ08-Y2000
HLMP-EH08-UX000
HLMP-EH08-VY000
HLMP-EJ10-X1000
HLMP-EJ10-Y2000
HLMP-EH10-UX000
HLMP-EH10-VY000
7200
9300
3200
4200
21000
27000
9300
12000
Red-Orange 615
HLMP-EH08-WZ000
HLMP-EH08-X1000
HLMP-EH08-Y2000
HLMP-EH10-WZ000
HLMP-EH10-X1000
HLMP-EH10-Y2000
5500
7200
9300
16000
21000
21000
HLMP-EG08-VW000
HLMP-EG08-VY000
HLMP-EG08-WZ000
HLMP-EG10-VY000
HLMP-EG10-WZ000
4200
4200
5500
7200
12000
16000
6°[5]
Red 626
HLMP-EG08-X1000
HLMP-EG08-YZ000
HLMP-EG08-Y1000
HLMP-EG10-X1000
7200
9300
9300
21000
16000
21000
HLMP-EG08-Y2000
HLMP-EG10-Y2000
9300
27000
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength, λd, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4. θ1/2 is the off-axis angle where the luminous intensity is one half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at the intensity peak.
Part numbers in bold are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.
2
Luminous Intensity
Iv (mcd) [1,2] @ 20 mA
Min.
Max.
4200
12000
Device Selection Guide (Continued)
Typical
Viewing Angle
2θ 1/2 (Deg.)[4]
Color and Dominant
Wavelength
(nm), Typ.[3]
Lamps Without
Standoffs on Leads
(Outline Drawing A)
HLMP-EL15-PS000
1150
1150
1150
1150
1900
1900
2500
2500
HLMP-EL15-QSK00*
HLMP-EL15-QT000
HLMP-EL15-QTK00*
HLMP-EL17-QT000
1150
1150
1150
2500
3200
3200
HLMP-EL17-RU000
HLMP-EL17-SV000
HLMP-EL17-TW000
1500
1900
2500
4200
5500
7200
HLMP-EL17-UX000
2500
2500
2500
3200
7200
4200
5500
9300
4200
4200
4200
12000
12000
9300
HLMP-EL15-VXK00*
HLMP-EL15-VX400**
HLMP-EL15-VW000*
4200
4200
4200
9300
9300
7200
HLMP-EL15-VWK00*
HLMP-EJ15-PS000
HLMP-EJ15-RU000
HLMP-EJ17-RU000
4200
880
1500
7200
2500
4200
HLMP-EJ15-SV000
HLMP-EH15-QT000
HLMP-EH15-RU000
HLMP-EH15-TW000
HLMP-EJ17-SV000
HLMP-EH17-QT000
HLMP-EH17-RU000
HLMP-EH17-TW000
1900
1150
1500
2500
5500
3200
4200
7200
HLMP-EH15-UX000
HLMP-EH17-UX000
3200
9300
HLMP-EL15-TW000
HLMP-EL15-TWK00*
HLMP-EL15-TUK00*
HLMP-EL15-TV400**
HLMP-EL15-UX000
15°
HLMP-EL15-VY000
HLMP-EL15-VYK00*
HLMP-EL15-VX000
Orange 605
Red-Orange 615
HLMP-EL17-VY000
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength, λd, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4. θ 1/2 is the off-axis angle where the luminous intensity is one half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at the intensity peak.
Part numbers in bold are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.
3
Luminous Intensity
Iv (mcd) [1,2] @ 20 mA
Min.
Max.
880
2500
HLMP-EL15-QR000
HLMP-EL15-QRK00*
HLMP-EL15-QS000
HLMP-EL15-QS400**
HLMP-EL15-RU000
Amber 590
Lamps With Standoffs
on Leads
(Outline Drawing B)
HLMP-EL17-PS000
Device Selection Guide (Continued)
Typical
Viewing Angle
2θ 1/2 (Deg.)[4]
15°
Color and Dominant
Wavelength
(nm), Typ.[3]
Red 626
Lamps Without
Standoffs on Leads
(Outline Drawing A)
HLMP-EG15-PS000
Lamps With Standoffs
on Leads
(Outline Drawing B)
Luminous Intensity
Iv (mcd) [1,2] @ 20 mA
Min.
Max.
880
2500
HLMP-EG15-QT000
HLMP-EG15-RU000
HLMP-EG15-UX000
HLMP-EG15-TW000
HLMP-EG17-QT000
HLMP-EG17-RU000
HLMP-EG17-UX000
HLMP-EG17-TW000
1150
1500
3200
2500
3200
4200
9300
7200
HLMP-EL26-NR000
HLMP-EL26-PS000
520
680
880
1500
1900
2500
HLMP-EL24-PSK00*
HLMP-EL24-PR400**
HLMP-EL24-PQK00*
880
880
880
2500
1900
1500
HLMP-EL24-QR000
HLMP-EL24-QRK00*
HLMP-EL24-QS000
HLMP-EL24-QSK00*
1150
1150
1150
1150
1900
1900
2500
2500
HLMP-EL24-QS400**
HLMP-EL24-QT000
HLMP-EL24-QTK00*
1150
1150
1150
2500
3200
3200
1500
1500
1900
4200
4200
5500
HLMP-EL24-STK00*
HLMP-EL24-SUK00*
HLMP-EL24-SU400**
1900
1900
1900
3200
4200
4200
HLMP-EL24-SV000
HLMP-EL24-SVK00*
HLMP-EL24-TW000
HLMP-EL24-TWK00*
1900
1900
2500
2500
5500
5500
7200
7200
HLMP-EL24-MQ000
HLMP-EL24-NR000
HLMP-EL24-PS000
23°
Amber 590
HLMP-EL24-RU000
HLMP-EL24-RUK00*
HLMP-EL26-QT000
HLMP-EL26-RU000
HLMP-EL26-SV000
HLMP-EL26-TW000
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength, λd, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4. θ 1/2 is the off-axis angle where the luminous intensity is one half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at the intensity peak.
Part numbers in bold are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.
4
Device Selection Guide (Continued)
Typical
Viewing Angle
2θ 1/2 (Deg.)[4]
Color and Dominant
Wavelength
(nm), Typ.[3]
Lamps Without
Standoffs on Leads
(Outline Drawing A)
Lamps With Standoffs
on Leads
(Outline Drawing B)
Orange 605
HLMP-EJ24-QT000
HLMP-EJ24-RU000
Red-Orange 615
HLMP-EH24-QT000
HLMP-EJ26-QT000
HLMP-EJ26-RU000
HLMP-EH26-PS000
HLMP-EH26-QT000
Luminous Intensity
Iv (mcd) [1,2] @ 20 mA
Min.
Max.
1150
3200
1500
4200
880
2500
1150
3200
HLMP-EH24-RU000
HLMP-EH24-SV000
HLMP-EG24-PS000
HLMP-EH26-RU000
HLMP-EH26-SV000
HLMP-EG26-PS000
1500
1900
880
4200
5500
2500
HLMP-EG24-QT000
HLMP-EG24-RU000
HLMP-EL30-MQ000
HLMP-EG26-QT000
HLMP-EG26-RU000
HLMP-EL32-MQ000
1150
1500
520
3200
4200
1500
HLMP-EL30-NR000
HLMP-EL30-PQ000
HLMP-EL30-PQK00*
HLMP-EL30-PR000
HLMP-EL32-NR000
680
880
880
880
1900
1500
1500
1900
880
880
880
1900
1900
2500
880
1150
1150
2500
1900
2500
1150
1150
1150
2500
3200
3200
1900
1900
1900
1900
3200
4200
4200
4200
23º
Red 626
HLMP-EL30-PR400**
HLMP-EL30-PRK00*
HLMP-EL30-PS000
30°
Amber 590
HLMP-EL32-PS000
HLMP-EL30-PSK00*
HLMP-EL30-QRK00*
HLMP-EL30-QS000
HLMP-EL30-QS400**
HLMP-EL30-QT000
HLMP-EL30-QTK00*
HLMP-EL32-QT000
HLMP-EL30-ST000
HLMP-EL30-SU000
HLMP-EL30-SU400**
HLMP-EL30-SUK00*
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength, λd, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4. θ 1/2 is the off-axis angle where the luminous intensity is one half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at the intensity peak.
Part numbers in bold are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.
5
Device Selection Guide (Continued)
Typical
Viewing Angle
2θ 1/2 (Deg.)[4]
Color and Dominant
Wavelength
(nm), Typ.[3]
Lamps Without
Standoffs on Leads
(Outline Drawing A)
HLMP-EL30-STK00*
Amber
HLMP-EL30-SV000
HLMP-EL30-SVK00*
Lamps With Standoffs
on Leads
(Outline Drawing B)
HLMP-EL32-SV000
HLMP-EJ30-MQ000
Orange 605
30°
Red-Orange 615
Red 626
1900
1900
1900
520
5500
5500
5500
1500
HLMP-EJ30-NR000
HLMP-EJ30-PS000
HLMP-EH30-MQ000
HLMP-EJ32-NR000
HLMP-EJ32-PS000
HLMP-EH32-MQ000
680
880
520
1900
2500
1500
HLMP-EH30-NR000
HLMP-EH30-PS000
HLMP-EH30-QT000
HLMP-EH32-NR000
HLMP-EH32-PS000
HLMP-EH32-QT000
680
880
1150
1900
2500
3200
HLMP-EH30-RU000
HLMP-EG30-KN000
HLMP-EG30-MQ000
HLMP-EG30-NQ000
HLMP-EH32-RU000
1500
310
520
680
4200
880
1500
1500
HLMP-EG30-NR000
HLMP-EG30-PQ000
HLMP-EG30-PR000
HLMP-EG32-NR000
680
880
880
1900
1500
1900
HLMP-EG30-PS000
HLMP-EG30-QT000
HLMP-EG32-PS000
HLMP-EG32-QT000
880
1150
2500
3200
HLMP-EG32-MQ000
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength, λd, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4. θ 1/2 is the off-axis angle where the luminous intensity is one half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at the intensity peak.
Part numbers in bold are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.
6
Luminous Intensity
Iv (mcd) [1,2] @ 20 mA
Min.
Max.
1900
3200
Part Numbering System
HLMP - x x xx - x x x xx
Mechanical Options
00: Bulk Packaging
DD: Ammo Pack
YY: Flexi-Bin; Bulk Packaging
ZZ: Flexi-Bin; Ammo Pack
Color Bin Selections
0: No color bin limitation
4: Amber color bin 4 only
K: Amber color bins 2 and 4 only
Maximum Intensity Bin
0: No Iv bin limitation
Minimum Intensity Bin
Viewing Angle & Lead Stand Offs
08: 6 deg without lead stand offs
10: 6 deg with lead stand offs
15: 15 deg without lead stand offs
17: 15 deg with lead stand offs
24: 23 deg without lead stand offs
26: 23 deg with lead stand offs
30: 30 deg without lead stand offs
32: 30 deg with lead stand offs
Color
G: 626 nm Red
H: 615 nm Red-Orange
J: 605 nm Orange
L: 590 nm Amber
Package
E: 5 mm Round
7
Package Dimensions
A
B
5.00 ± 0.20
(0.197 ± 0.008)
8.71 ± 0.20
(0.343 ± 0.008)
5.00 ± 0.20
(0.197 ± 0.008)
1.14 ± 0.20
(0.045 ± 0.008)
8.71 ± 0.20
(0.343 ± 0.008)
d
1.14 ± 0.20
(0.045 ± 0.008)
2.35 (0.093)
MAX.
0.70 (0.028)
MAX.
31.60
MIN.
(1.244)
1.50 ± 0.15
(0.059 ± 0.006)
31.60
MIN.
(1.244)
0.70 (0.028)
MAX.
CATHODE
LEAD
1.00 MIN.
(0.039)
CATHODE
FLAT
CATHODE
LEAD
0.50 ± 0.10
SQ. TYP.
(0.020 ± 0.004)
5.80 ± 0.20
(0.228 ± 0.008)
CATHODE
FLAT
2.54 ± 0.38
(0.100 ± 0.015)
NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS (INCHES).
2. LEADS ARE MILD STEEL, SOLDER DIPPED.
3. TAPERS SHOWN AT TOP OF LEADS (BOTTOM OF LAMP PACKAGE) INDICATE AN
EPOXY MENISCUS THAT MAY EXTEND ABOUT 1 mm (0.040 in.) DOWN THE LEADS.
4. RECOMMENDED PC BOARD HOLE DIAMETERS:
• LAMP PACKAGE A WITHOUT STAND-OFFS: FLUSH MOUNTING AT BASE OF
LAMP PACKAGE = 1.143/1.067 (0.044/0.042).
• LAMP PACKAGE B WITH STAND-OFFS: MOUNTING AT LEAD STAND-OFFS
= 0.965/0.889 (0.038/0.035).
5. FOR DOME HEIGHTS ABOVE LEAD STAND-OFF SEATING PLANE, d, LAMP PACKAGE B, SEE TABLE.
8
0.50 ± 0.10
SQ. TYP.
(0.020 ± 0.004)
1.00 MIN.
(0.039)
5.80 ± 0.20
(0.228 ± 0.008)
2.54 ± 0.38
(0.100 ± 0.015)
PART NO.
d
HLMP-XX10
12.37 ± 0.25
(0.487 ± 0.010)
12.42 ± 0.25
(0.489 ± 0.010)
HLMP-XX17
HLMP-XX26
12.52 ± 0.25
(0.493 ± 0.010)
HLMP-XX32
11.96 ± 0.25
(0.471 ± 0.010)
Absolute Maximum Ratings at TA = 25°C
DC Forward Current[1,2,3] ..................................................................50 mA
Peak Pulsed Forward Current[2,3] ................................................. 100 mA
Average Forward Current[3] .............................................................30 mA
Reverse Voltage (IR = 100 µA) ................................................................ 5 V
LED Junction Temperature .............................................................. 130° C
Operating Temperature ................................................... -40°C to +100° C
Storage Temperature ....................................................... -40°C to +120° C
Solder Dipping Temperature ................................... 260°C for 5 seconds
Wave Solder Temperature ........................................ 250°C for 3 seconds
[1.59 mm (0.060 in.) below body]
Notes:
1. Derate linearly as shown in Figure 4.
2. For long term performance with minimal light output degradation, drive currents
between 10 mA and 30 mA are recommended. For more information on recommended
drive conditions, please refer to Application Brief I-024 (5966-3087E).
3. Operating at currents below 1 mA is not recommended. Please contact your local
representative for further information.
Electrical/Optical Characteristics at TA = 25°C
Parameter
Symbol
Forward Voltage
Amber (ld = 590 nm)
Orange (l d = 605 nm)
VF
Red-Orange (ld = 615 nm)
Red (ld = 626 nm)
Reverse Voltage
VR
Peak Wavelength:
Amber (ld = 590 nm)
Orange (l d = 605 nm)
lPEAK
Red-Orange (ld = 615 nm)
Red (ld = 626 nm)
Spectral Halfwidth
∆l 1/2
Min.
Typ.
5
2.02
1.98
1.94
1.90
20
Max.
Units
2.4
V
V
592
609
621
635
17
nm
nm
Speed of Response
ts
20
ns
Capacitance
Thermal Resistance
C
RqJ-PIN
40
240
pF
°C/W
Luminous Efficacy[1]
Amber (ld = 590 nm)
Orange (l d = 605 nm)
Red-Orange (ld = 615 nm)
Red (ld = 626 nm)
hv
480
370
260
150
lm/W
Test Conditions
IF = 20 mA
IF = 100 µA
Peak of Wavelength of
Spectral Distribution
at IF = 20 mA
Wavelength Width at
Spectral Distribution
1/2 Power Point at
IF = 20 mA
Exponential Time
Constant, e-t/ts
VF = 0, f = 1 MHz
LED Junction-to-Cathode
Lead
Emitted Luminous
Power/Emitted Radiant
Power
Note:
1. The radiant intensity, Ie, in watts per steradian, may be found from the equation Ie = Iv/h v, where Iv is the luminous intensity in candelas and h v is
the luminous efficacy in lumens/watt.
9
1.0
100
RED-ORANGE
AMBER
80
RED
70
CURRENT – mA
RELATIVE INTENSITY
ORANGE
90
0.5
60
RED
50
40
AMBER
30
20
10
0
550
600
650
0
1.0
700
1.5
WAVELENGTH – nm
2.0
2.5
Figure 1. Relative Intensity vs. Peak Wavelength.
Figure 2. Forward Current vs. Forward Voltage.
3.0
IF – FORWARD CURRENT – mA
RELATIVE LUMINOUS INTENSITY
(NORMALIZED AT 20 mA)
50
2.5
2.0
1.5
1.0
0.5
0
0
20
40
40
30
RθJA = 780° C/W
20
10
0
60
RθJA = 585° C/W
0
20
40
Figure 3. Relative Luminous Intensity vs.
Forward Current.
RELATIVE INTENSITY – %
90
80
70
60
50
40
30
20
10
-15
-10
-5
0
5
10
15
20
θ – ANGULAR DISPLACEMENT – DEGREES
Figure 5. Representative Spatial Radiation Pattern for 6° Viewing Angle Lamps.
10
80
100
Figure 4. Maximum Forward Current vs. Ambient
Temperature. Derating Based on TJMAX = 130°C.
100
-20
60
TA – AMBIENT TEMPERATURE – °C
IF – DC FORWARD CURRENT – mA
0
-25
3.0
VF – FORWARD VOLTAGE – V
25
Intensity Bin Limits
(mcd at 20 mA)
100
RELATIVE INTENSITY – %
90
80
70
60
50
40
30
20
10
0
-25
-20
-15
-10
-5
0
5
10
15
20
25
θ – ANGULAR DISPLACEMENT – DEGREES
Figure 6. Representative Spatial Radiation Pattern for 15° Viewing Angle Lamps.
1.00
RELATIVE INTENSITY – %
0.90
0.80
0.70
0.60
0.50
0.40
Bin Name
Min.
Max.
K
L
310
400
400
520
M
520
680
N
680
880
P
Q
880
1150
1150
1500
R
1500
1900
S
T
1900
2500
2500
3200
U
3200
4200
V
W
4200
5500
5500
7200
X
7200
9300
Y
9300
12000
Z
1
12000
16000
16000
21000
2
21000
27000
Tolerance for each bin limit is ± 15%.
0.30
0.20
0.10
0
-25
-20
-15
-10
-5
0
5
10
15
20
25
θ – ANGULAR DISPLACEMENT – DEGREES
Amber Color Bin Limits
(nm at 20 mA)
Figure 7. Representative Spatial Radiation Pattern for 23° Viewing Angle Lamps.
100
RELATIVE INTENSITY – %
90
Bin Name
Min.
Max.
1
584.5
587.0
2
587.0
589.5
4
589.5
592.0
6
592.0
594.5
Tolerance for each bin limit is ± 0.5 nm.
80
70
60
50
40
30
20
10
0
-25
-20
-15
-10
-5
0
5
10
15
20
25
θ – ANGULAR DISPLACEMENT – DEGREES
Figure 8. Representative Spatial Radiation Pattern for 30° Viewing Angle Lamps.
11
Note:
1. Bin categories are established for
classification of products. Products
may not be available in all bin
categories.
www.agilent.com/semiconductors
For product information and a complete list of
distributors, please go to our web site.
For technical assistance call:
Americas/Canada: +1 (800) 235-0312 or
(916) 788-6763
Europe: +49 (0) 6441 92460
China: 10800 650 0017
Hong Kong: (+65) 6756 2394
India, Australia, New Zealand: (+65) 6755 1939
Japan: (+81 3) 3335-8152(Domestic/International), or 0120-61-1280(Domestic Only)
Korea: (+65) 6755 1989
Singapore, Malaysia, Vietnam, Thailand,
Philippines, Indonesia: (+65) 6755 2044
Taiwan: (+65) 6755 1843
Data subject to change.
Copyright © 2005 Agilent Technologies, Inc.
Obsoletes 5989-0659EN
April 27, 2005
5989-2916EN