IDC Plug Wire-To-Board: 14-9159-100
General Description
KYOCERA AVX developed the 9159 Series of SMT connectors for co-planar PCB mating
for the challenging Solid State Lighting (SSL) market. These connectors needed to be
small, low in height, carry up to 5 Amps/contact, and then function up to 125°C for
extended periods. This application has been very unique to the SSL market where
PCB’s are stacked end-to-end to create linear strip lighting in everything from office to
transportation applications.
The IDC cable plug connector allows for 22-24AWG discrete or cabled wires to be
easily and reliably terminated into a 9159 standard interface socket connector. This
will allow power and signals to be connected onto a PCB socket connector while
providing positive latching. The wire assembly support block allows for 2 through 6
wires to be terminated all in one step with any standard bench top press. IDC covers
provide both through (daisy chain applications) and wire stop termination options.
APPLICATIONS
FEATURES AND BENEFITS
• Mates with standard 9159 horizontal socket,
keeping same BTB connector system
• Economical and reliable IDC wire termination
• Molded latch offers positive latching after
mating
• Provides Wire-to-Board capabilities to standard 9159 2-Piece
connector system
• In conjunction with the IDC socket WTB connector (24-9159), these
connectors provide maximum flexibility to bring power and signal
wires onto or off of any board level 9159 connector
• Reference application notes 201-01-123
• Reference Product Specification 201-01-119
ELECTRICAL
ENVIRONMENTAL
MECHANICAL
• Current Rating: 5 Amps / Contact
• Voltage Rating: 125 VAC (RMS) or DC
equivalent
• Operating Temperature:
-40ºC to +125ºC
• Storage Temperature:
-40ºC to +70ºC
•
•
•
•
Insulator Material: Nylon: UL94VO
Contact Material: Phosphor Bronze
Plating: Gold / Tin over Nickel
Durability: 10 Cycles
HOW TO ORDER
Prefix
Right Angle
Wired Plug
IDC
9159
00X
Series Number of Ways
Code
No of
Details
Ways
THROUGH WIRE CAP
002
2
PAGE 26
003
3
PAGE 27
004
4
PAGE 28
005
5
PAGE 29
006
6
PAGE 30
WIRE STOP CAP
002
2
PAGE 31
003
3
PAGE 32
004
4
PAGE 33
005
5
PAGE 34
006
6
PAGE 35
1
X
2
2 Part Wire Gauge
Wire
PCB Strip 2 = 22AWG Insulation
Connector 3 = 24AWG Diameter
2 Part
Wired IDC
Strip
Connector
ø1.10mm
to ø1.60mm
X
X
14
Color/Approval
Code
8
9
Color
Black
White
Approval
UL Approved
UL Approved
6
Cap Options
Code
0
9
Cap
Option
Description
Allows wires to
Through
be terminated
Wire
at any point
Terminates end
Wire
of wire. End
Stop protected with
Stop Face
Plating Option
Code
Contact
6
Gold on
Contact Tin on
IDC
Safety Standards: UL 1977-File #E90723, CSA C22.2 NO. 182.3
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
TDS-BTB-0008 | Rev 1
– board to board connector solutions –
25
IDC Plug Wire-To-Board: 14-9159-100
2 Position Through Wire Cap
PLUG-WIRED – 2 WAY THROUGH WIRE CAP
NOTES:
1. FOR MORE INFORMATION REFER TO PRODUCT SPEC 201-01-119. FOR WIRE ASSEMBLY REFER TO
APPLICATION NOTES 201-01-123.
Code
2. THROUGH WIRE CAP, FOR TERMINATION OF WIRE IN ANY POSITION.
Wire Gauge
Dimension A
(Page 24)
3. CAP ACTS AS WIRE ASSEMBLY TOOL. WIRE PREFIT TO CAP, NARROW SLOT TO GRIP WIRE,
22AWG
122
0.47
PERMANENT ASSEMBLY.
(Stranded Wire)
4. GENERAL TOLERANCE ±0.20 UNLESS SPECIFIED.
24AWG
132
0.37
5. INSULATOR MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR REFER TO PAGE 25.
(Standed Wire)
6. CONTACT MATERIAL: COPPER ALLOY, PLATING NICKEL BASE ALL OVER, GOLD ON CONTACT, TIN
ON IDC.
7. PACKING IN TAPE AND REEL. QTY PER REEL 700, POCKET CONTAINS 1 CONNECTOR AND 1 CAP.
8. WIRE GAUGE OPTIONS, SEE TABLE.
9. ASSEMBLY AIDS, REFER TO PAGE 36.
PACKING DETAILS
CAP AND CONNECTOR SUPPLIED TOGETHER (2 PARTS)
26
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
TDS-BTB-0008 | Rev 1
– board to board connector solutions –
Wire Insulation
Diameter
1.10 to 1.60
1.10 to 1.60
IDC Plug Wire-To-Board: 14-9159-100
3 Position Through Wire Cap
PLUG-WIRED – 3 WAY THROUGH WIRE CAP
NOTES:
1. FOR MORE INFORMATION REFER TO PRODUCT SPEC 201-01-119. FOR WIRE
ASSEMBLY REFER TO APPLICATION NOTES 201-01-123.
Code
2. THROUGH WIRE CAP, FOR TERMINATION OF WIRE IN ANY POSITION.
Wire Gauge
Dimension A
(Page 24)
3. CAP ACTS AS WIRE ASSEMBLY TOOL. WIRE PREFIT TO CAP, NARROW SLOT TO GRIP WIRE,
22AWG
PERMANENT ASSEMBLY.
122
0.47
(Stranded Wire)
4. GENERAL TOLERANCE ±0.20 UNLESS SPECIFIED.
24AWG
5. INSULATOR MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR REFER TO PAGE 25.
132
0.37
(Standed Wire)
6. CONTACT MATERIAL: COPPER ALLOY, PLATING NICKEL BASE ALL OVER, GOLD ON CONTACT, TIN
ON IDC.
7. PACKING IN TAPE AND REEL. QTY PER REEL 700, POCKET CONTAINS 1 CONNECTOR AND 1 CAP.
8. WIRE GAUGE OPTIONS, SEE TABLE.
9. ASSEMBLY AIDS, REFER TO PAGE 36.
Wire Insulation
Diameter
1.10 to 1.60
1.10 to 1.60
PACKING DETAILS
CAP AND CONNECTOR SUPPLIED TOGETHER (2 PARTS)
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
TDS-BTB-0008 | Rev 1
– board to board connector solutions –
27
IDC Plug Wire-To-Board: 14-9159-100
4 Position Through Wire Cap
PLUG-WIRED – 4 WAY THROUGH WIRE CAP
NOTES:
1. FOR MORE INFORMATION REFER TO PRODUCT SPEC 201-01-119. FOR WIRE ASSEMBLY REFER TO
APPLICATION NOTES 201-01-123.
Code
2. THROUGH WIRE CAP, FOR TERMINATION OF WIRE IN ANY POSITION.
Wire Gauge
Dimension A
(Page 24)
3. CAP ACTS AS WIRE ASSEMBLY TOOL. WIRE PREFIT TO CAP, NARROW SLOT TO GRIP WIRE,
22AWG
122
0.47
PERMANENT ASSEMBLY.
(Stranded Wire)
4. GENERAL TOLERANCE ±0.20 UNLESS SPECIFIED.
24AWG
132
0.37
5. INSULATOR MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR REFER TO PAGE 25.
(Standed Wire)
6. CONTACT MATERIAL: COPPER ALLOY, PLATING NICKEL BASE ALL OVER, GOLD ON CONTACT, TIN
ON IDC.
7. PACKING IN TAPE AND REEL. QTY PER REEL 700, POCKET CONTAINS 1 CONNECTOR AND 1 CAP.
8. WIRE GAUGE OPTIONS, SEE TABLE.
9. ASSEMBLY AIDS, REFER TO PAGE 36.
PACKING DETAILS
CAP AND CONNECTOR SUPPLIED TOGETHER (2 PARTS)
28
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
TDS-BTB-0008 | Rev 1
– board to board connector solutions –
Wire Insulation
Diameter
1.10 to 1.60
1.10 to 1.60
IDC Plug Wire-To-Board: 14-9159-100
5 Position Through Wire Cap
PLUG-WIRED – 5 WAY THROUGH WIRE CAP
NOTES:
1. FOR MORE INFORMATION REFER TO PRODUCT SPEC 201-01-119. FOR WIRE ASSEMBLY REFER TO
APPLICATION NOTES 201-01-123.
Code
2. THROUGH WIRE CAP, FOR TERMINATION OF WIRE IN ANY POSITION.
Wire Gauge
Dimension A
(Page 24)
3. CAP ACTS AS WIRE ASSEMBLY TOOL. WIRE PREFIT TO CAP, NARROW SLOT TO GRIP WIRE,
22AWG
122
0.47
PERMANENT ASSEMBLY.
(Stranded Wire)
4. GENERAL TOLERANCE ±0.20 UNLESS SPECIFIED.
24AWG
132
0.37
5. INSULATOR MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR REFER TO PAGE 25.
(Standed Wire)
6. CONTACT MATERIAL: COPPER ALLOY, PLATING NICKEL BASE ALL OVER, GOLD ON CONTACT, TIN
ON IDC.
7. PACKING IN TAPE AND REEL. QTY PER REEL 700, POCKET CONTAINS 1 CONNECTOR AND 1 CAP.
8. WIRE GAUGE OPTIONS, SEE TABLE.
9. ASSEMBLY AIDS, REFER TO PAGE 36.
Wire Insulation
Diameter
1.10 to 1.60
1.10 to 1.60
PACKING DETAILS
CAP AND CONNECTOR SUPPLIED TOGETHER (2 PARTS)
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
TDS-BTB-0008 | Rev 1
– board to board connector solutions –
29
IDC Plug Wire-To-Board: 14-9159-100
6 Position Through Wire Cap
PLUG-WIRED – 6 WAY THROUGH WIRE CAP
NOTES:
1. FOR MORE INFORMATION REFER TO PRODUCT SPEC 201-01-119. FOR WIRE ASSEMBLY REFER TO
APPLICATION NOTES 201-01-123.
Code
2. THROUGH WIRE CAP, FOR TERMINATION OF WIRE IN ANY POSITION.
Wire Gauge
Dimension A
(Page 24)
3. CAP ACTS AS WIRE ASSEMBLY TOOL. WIRE PREFIT TO CAP, NARROW SLOT TO GRIP WIRE,
22AWG
122
0.47
PERMANENT ASSEMBLY.
(Stranded Wire)
4. GENERAL TOLERANCE ±0.20 UNLESS SPECIFIED.
24AWG
132
0.37
5. INSULATOR MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR REFER TO PAGE 25.
(Standed Wire)
6. CONTACT MATERIAL: COPPER ALLOY, PLATING NICKEL BASE ALL OVER, GOLD ON CONTACT, TIN
ON IDC.
7. PACKING IN TAPE AND REEL. QTY PER REEL 700, POCKET CONTAINS 1 CONNECTOR AND 1 CAP.
8. WIRE GAUGE OPTIONS, SEE TABLE.
9. ASSEMBLY AIDS, REFER TO PAGE 36.
PACKING DETAILS
CAP AND CONNECTOR SUPPLIED TOGETHER (2 PARTS)
30
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
TDS-BTB-0008 | Rev 1
– board to board connector solutions –
Wire Insulation
Diameter
1.10 to 1.60
1.10 to 1.60
IDC Plug Wire-To-Board: 14-9159-100
2 Position Wire Stop Cap
PLUG-WIRED – 2 WAY WIRE STOP CAP
NOTES:
1. FOR MORE INFORMATION REFER TO PRODUCT SPEC 201-01-119.
FOR WIRE ASSEMBLY REFER TO APPLICATION NOTES 201-01-123.
Code
Wire Gauge
Dimension A
2. WIRE STOP CAP, WITH STOP FACE O ONE SIDE TO PROTECT END OF WIRE.
(Page 24)
3. CAP ACTS AS WIRE ASSEMBLY TOOL. WIRE PREFIT TO CAP, NARROW SLOT TO GRIP WIRE,
22AWG
122
0.47
PERMANENT ASSEMBLY.
(Stranded Wire)
4. GENERAL TOLERANCE ±0.20 UNLESS SPECIFIED.
24AWG
132
0.37
5. INSULATOR MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR REFER TO PAGE 25.
(Standed Wire)
6. CONTACT MATERIAL: COPPER ALLOY, PLATING NICKEL BASE ALL OVER, GOLD ON CONTACT, TIN
ON IDC.
7. PACKING IN TAPE AND REEL. QTY PER REEL 700, POCKET CONTAINS 1 CONNECTOR AND 1 CAP.
8. WIRE GAUGE OPTIONS, SEE TABLE.
9. SHOWN WITH WIRE ENTRY FROM UNDERSIDE, CAP CAN BE ASSEMBLED FOR EITHER TOP OR
UNDERSIDE WIRE ENTRY.
10. ASSEMBLY AIDS, REFER TO PAGE 36.
Wire Insulation
Diameter
1.10 to 1.60
1.10 to 1.60
PACKING DETAILS
CAP AND CONNECTOR SUPPLIED TOGETHER (2 PARTS)
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
TDS-BTB-0008 | Rev 1
– board to board connector solutions –
31
IDC Plug Wire-To-Board: 14-9159-100
3 Position Wire Stop Cap
PLUG-WIRED – 3 WAY WIRE STOP CAP
NOTES:
1. FOR MORE INFORMATION REFER TO PRODUCT SPEC 201-01-119.
FOR WIRE ASSEMBLY REFER TO APPLICATION NOTES 201-01-123.
Code
Wire Gauge
Dimension A
2. WIRE STOP CAP, WITH STOP FACE O ONE SIDE TO PROTECT END OF WIRE.
(Page 24)
3. CAP ACTS AS WIRE ASSEMBLY TOOL. WIRE PREFIT TO CAP, NARROW SLOT TO GRIP WIRE,
22AWG
122
0.47
PERMANENT ASSEMBLY.
(Stranded Wire)
4. GENERAL TOLERANCE ±0.20 UNLESS SPECIFIED.
24AWG
132
0.37
5. NSULATOR MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR REFER TO PAGE 25.
(Standed Wire)
6. CONTACT MATERIAL: COPPER ALLOY, PLATING NICKEL BASE ALL OVER, GOLD ON CONTACT, TIN
ON IDC.
7. PACKING IN TAPE AND REEL. QTY PER REEL 700, POCKET CONTAINS 1 CONNECTOR AND 1 CAP.
8. WIRE GAUGE OPTIONS, SEE TABLE.
9. SHOWN WITH WIRE ENTRY FROM UNDERSIDE, CAP CAN BE ASSEMBLED FOR EITHER TOP OR
UNDERSIDE WIRE ENTRY.
10. ASSEMBLY AIDS, REFER TO PAGE 36.
PACKING DETAILS
CAP AND CONNECTOR SUPPLIED TOGETHER (2 PARTS)
32
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
TDS-BTB-0008 | Rev 1
– board to board connector solutions –
Wire Insulation
Diameter
1.10 to 1.60
1.10 to 1.60
IDC Plug Wire-To-Board: 14-9159-100
4 Position Wire Stop Cap
PLUG-WIRED – 4 WAY WIRE STOP CAP
NOTES:
1. FOR MORE INFORMATION REFER TO PRODUCT SPEC 201-01-119.
FOR WIRE ASSEMBLY REFER TO APPLICATION NOTES 201-01-123.
2. WIRE STOP CAP, WITH STOP FACE O ONE SIDE TO PROTECT END OF WIRE.
Code
Wire Gauge
Dimension A
3. CAP ACTS AS WIRE ASSEMBLY TOOL. WIRE PREFIT TO CAP, NARROW SLOT TO GRIP WIRE,
(Page 24)
PERMANENT ASSEMBLY.
22AWG
122
0.47
4. GENERAL TOLERANCE ±0.20 UNLESS SPECIFIED.
(Stranded Wire)
5. INSULATOR MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR REFER TO PAGE 25.
24AWG
132
0.37
6. CONTACT MATERIAL: COPPER ALLOY, PLATING NICKEL BASE ALL OVER, GOLD ON CONTACT,
(Standed Wire)
TIN ON IDC.
7. PACKING IN TAPE AND REEL. QTY PER REEL 700, POCKET CONTAINS 1 CONNECTOR AND 1 CAP.
8. WIRE GAUGE OPTIONS, SEE TABLE.
9. SHOWN WITH WIRE ENTRY FROM UNDERSIDE, CAP CAN BE ASSEMBLED FOR EITHER TOP OR
UNDERSIDE WIRE ENTRY.
10. ASSEMBLY AIDS, REFER TO PAGE 36.
Wire Insulation
Diameter
1.10 to 1.60
1.10 to 1.60
PACKING DETAILS
CAP AND CONNECTOR SUPPLIED TOGETHER (2 PARTS)
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
TDS-BTB-0008 | Rev 1
– board to board connector solutions –
33
IDC Plug Wire-To-Board: 14-9159-100
5 Position Wire Stop Cap
PLUG-WIRED – 5 WAY WIRE STOP CAP
NOTES:
1. FOR MORE INFORMATION REFER TO PRODUCT SPEC 201-01-119.
FOR WIRE ASSEMBLY REFER TO APPLICATION NOTES 201-01-123.
2. WIRE STOP CAP, WITH STOP FACE O ONE SIDE TO PROTECT END OF WIRE.
Code
Wire Gauge
Dimension A
3. CAP ACTS AS WIRE ASSEMBLY TOOL. WIRE PREFIT TO CAP, NARROW SLOT TO GRIP WIRE,
(Page 24)
PERMANENT ASSEMBLY.
22AWG
122
0.47
(Stranded Wire)
4. GENERAL TOLERANCE ±0.20 UNLESS SPECIFIED.
5. INSULATOR MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR REFER TO PAGE 25.
24AWG
132
0.37
(Standed Wire)
6. CONTACT MATERIAL: COPPER ALLOY, PLATING NICKEL BASE ALL OVER, GOLD ON CONTACT,
TIN ON IDC.
7. PACKING IN TAPE AND REEL. QTY PER REEL 700, POCKET CONTAINS 1 CONNECTOR AND 1 CAP.
8. WIRE GAUGE OPTIONS, SEE TABLE.
9. SHOWN WITH WIRE ENTRY FROM UNDERSIDE, CAP CAN BE ASSEMBLED FOR EITHER TOP OR
UNDERSIDE WIRE ENTRY.
10. ASSEMBLY AIDS, REFER TO PAGE 36.
PACKING DETAILS
CAP AND CONNECTOR SUPPLIED TOGETHER (2 PARTS)
34
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
TDS-BTB-0008 | Rev 1
– board to board connector solutions –
Wire Insulation
Diameter
1.10 to 1.60
1.10 to 1.60
IDC Plug Wire-To-Board: 14-9159-100
6 Position Wire Stop Cap
PLUG-WIRED – 6 WAY WIRE STOP CAP
NOTES:
1. FOR MORE INFORMATION REFER TO PRODUCT SPEC 201-01-119.
FOR WIRE ASSEMBLY REFER TO APPLICATION NOTES 201-01-123.
2. WIRE STOP CAP, WITH STOP FACE O ONE SIDE TO PROTECT END OF WIRE.
3. CAP ACTS AS WIRE ASSEMBLY TOOL. WIRE PREFIT TO CAP, NARROW SLOT TO GRIP WIRE,
Code
Wire Gauge
Dimension A
PERMANENT ASSEMBLY.
(Page 24)
4. GENERAL TOLERANCE ±0.20 UNLESS SPECIFIED.
22AWG
122
0.47
(Stranded Wire)
5. INSULATOR MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR REFER TO PAGE 25.
6. CONTACT MATERIAL: COPPER ALLOY, PLATING NICKEL BASE ALL OVER, GOLD ON CONTACT,
24AWG
132
0.37
(Standed Wire)
TIN ON IDC.
7. PACKING IN TAPE AND REEL. QTY PER REEL 700, POCKET CONTAINS 1 CONNECTOR AND 1 CAP.
8. WIRE GAUGE OPTIONS, SEE TABLE.
9. SHOWN WITH WIRE ENTRY FROM UNDERSIDE, CAP CAN BE ASSEMBLED FOR EITHER TOP OR
UNDERSIDE WIRE ENTRY.
10. ASSEMBLY AIDS, REFER TO PAGE 36.
Wire Insulation
Diameter
1.10 to 1.60
1.10 to 1.60
PACKING DETAILS
CAP AND CONNECTOR SUPPLIED TOGETHER (2 PARTS)
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
TDS-BTB-0008 | Rev 1
– board to board connector solutions –
35
IDC Plug Wire-To-Board: 14-9159-100
Assembly Support Block / Insertion Tool
PLUG-WIRED – ASSEMBLY SUPPORT BLOCK
SECTION ON A-A
SECTION ON A-A
NOTES:
1. BLOCK TO SUPPORT 9159 IDC WIRED CONNECTORS DURING ASSEMBLY OF CAP/WIRE.
2. PART NUMBER 06-9159-7026-01-000, MATERIAL ALUMINUM. PART NUMBER 06-9159-7026-02-000,
MATERIAL NYLON 46.
3. CAN BE USED WITH EITHER THE PLUG OR SOCKET CONNECTORS, USE THE CORRECT SLOT AS IDENTIFIED.
4. FOR FULL WIRE ASSEMBLY DETAILS REFER TO APPLICATION NOTES 201-01-123.
5. ONLY A SIMPLE FLAT BOTTOMED TOOL REQUIRED TO PUSH THE CAP DOWN (NOT SUPPLIED.)
6. ALL DIMENSIONS ±0.20 UNLESS TOLERANCED.
7. 06-9159-7026-02-000 HAS RIBS TO HELP LOCATE CONTACT\/INSULATOR SUB-ASSEMBLY.
PLUG-WIRED – WIRE INSERTION TOOL
UNIVERSAL HANDLE 06-7000-7730-01-000
WIRE INSERTION TOOL 06-9159-7027-01-000
NOTES:
1. TOOL 06-9159-7027-01-000 TO INSERT WIRES INTO CAP.
2. FOR USE WITH UNIVERSAL HANDLE 06-7000-7720-01-000.
3. CAN BE USED WITH BOTH THROUGH WIRE AND WIRE STOP CAPS.
4. REFER TO APPLICATION NOTES 201-01-123 FOR FURTHER DETAILS.
36
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
TDS-BTB-0008 | Rev 1
– board to board connector solutions –