Issue: 01 Specification AXIOM40S Oscillator type : OCXO with Stratum 3E stabilitiy Parameter
Frequency range Standard frequencies Frequency stability overall Initial tolerance vs. temperature in operating temperature range operating temperature range vs. supply voltage variation vs. load change Holdover 24 hours, full temp. range 24 hours drift (after 30 days) long term stability over 15 years Frequency adjustment range Electronic Frequency Control (EFC) RF output Signal waveform Load Rise & decay time Symmetry (duty cycle) Warm-up time @25°C Phase noise @ 12.8 MHz
Date: 2005-07-15
min.
5
typ.
10 / 12.8 / 20
max.
20 ± 4.6 ± 500 ± 10
Unit Condition
MHz MHz ppm ppb ppb °C °C ppb ppb ppb ppb ppm Note 2 at time of shipment steady state Option II = “070” Option II = “2070” VS ± 5% ± 5% Telcordia GR-1244 CORE or ITU-T G.813 Option 1 15 years N.A.
0 -20
+70 +70 ±1 ±1 ± 12 ±1 ± 3.5 N.A. HCMOS 15
40 -90 -120 -140 -145 3.3 5.0
10 60 5
Supply voltage VS Current consumption (steady state) @25°C Current consumption (warm-up)
Operable temperature range Storage temperature range Enclosure (see drawing) LxWxH (Note 3) IEC 60679-3 CO 08 Weight Packing V HBM IEC 61000-4-2 ESD Sensitivity Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated 2. Overall frequency stability = initial tolerance + temp.stability + supply & load change + 15 years aging 3. Lower package height (15 mm, 13 mm) on request
3.65 5.25 350 250 800 500 -30 +75 -40 +85 36.1x27.2x19.4 max. 30 Bulk 1500
3.15 4.75
pF ns % min dBc dBc dBc dBc V V mA mA mA mA °C °C mm gram
@ VS/2 ∆ffinal/f0 < ±0.1 ppm 1 Hz 10 Hz 100 Hz 1000 Hz Option I = “33” Option I = “50” Option I = “33” Option I = “50” Option I = “33” Option I = “50”
Ordering Code:
Model (Specification) AXIOM40S Option I Option II
50
070
Frequency [MHz] 12.800
GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany
AXIOM40S page 1(2)
www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com
Enclosure:
Pin connections
Pin # Symbol 1 N.C. 2 N.C. 3 VS 4 RF OUT 5 GND Function No Connection No Connection Supply Voltage RF Output Ground
Environmental conditions:
Test Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* Bump* Free fall* IEC 60068 Part ... IEC 60679-1 clause ... 4.3 4.6.2 4.6.3 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55°C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days
2-17 2-20 2-58 2-27 2-29 2-32
4.6.8 4.6.6 4.6.9 4.6.7
Vibration, sinusoidal* 2-6
Rapid change of temperature Dry heat Damp heat, cyclic* Cold Climatic sequence* Damp heat, steady state* Endurance tests - ageing - extended aging
2-14 2-2 2-30 2-1 1-7 2-3
4.6.5 4.6.14 4.6.15 4.6.16 4.6.17 4.6.18
4.7.1 4.7.2
30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C
GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany
AXIOM40S page 2(2)
www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com
很抱歉,暂时无法提供与“AXIOM40S”相匹配的价格&库存,您可以联系我们找货