Issue: 01 Date: 2006-07-11 Specification AXIS45 Oscillator type : Wideband VCXO in double-sealed DIL package Direct replacement of Fujitsu M2 (F100) Parameter
Frequency range Standard frequencies Frequency stability Initial tolerance vs. temperature in operating temperature range vs. supply voltage variation vs. load change long term (aging) Frequency adjustment range Electronic Frequency Control (EFC) (Pulling range) See Note 2
min.
typ.
max.
Unit
MHz MHz ppm ppm ppm
Condition
5 30 16.384 / 24.576 / 27.000 / 28.224
± 100 ± 10 ±5 ± 10 ± 500 ± 1000 ± 1500* ± 2000* ± 2500* ± 3000* 0.25 0.15 positive 100 HCMOS 15 10 40 60 4 4.75 5.0 5.25 3.13 3.3 3.47 30 -20 +70 -40 +85 -45 +90 20.7x13.1x7.5 max. 3 sticks 1500 Full
-20°C ~+70°C
ppm ppm ppm/year @ 40°C ppm ppm ppm ppm ppm ppm V v % kΩ Option 2 = “ ” Option 2 = “1000” Option 2 = “1500” * Option 2 = “2000” * Option 2 = “2500” * Option 2 = “3000” * Option 1 = “50“ (5 V) Option 1 = “33” (3.3 V)
EFC voltage VC EFC slope (∆f / ∆VC) EFC linearity EFC input impedance RF output Signal waveform Load Rise & decay time Symmetry (duty cycle) Start-up time Supply voltage VS Current consumption Operating temperature range Operable temperature range Storage temperature range Enclosure (see drawing) LxWxH Weight Packing ESD Sensitivity RoHS compliance
4.75 3.15
pF ns % ms V V mA °C °C °C mm gram V
@ VS/2 Option 1 = “50“ (5 V) Option 1 = “33” (3.3 V) @ +25°C
IEC 60679-3 CO 02 IEC 60286-3 HBM, IEC 61000-4-2
Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated 2. *Pulling Range Option 3 > 1000 only possible with EFC voltage 0.25V ~ 4.75 V
Ordering Code:
Model (Specification) AXIS45
GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany
Option 1 Supply 50
Option 2 Pulling Range 2000
AXIS45 page 1(2)
Frequency [MHz] 28.224
www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com
Enclosure drawing
Pin connections
Pin # 1 7 8 14 Symbol VC GND RF OUT VS Function Control Voltage (EFC) Ground RF Output Supply Voltage
Environmental conditions
Test Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* Bump* Free fall* IEC 60068 Part ... IEC 60679-1 clause ... 4.3 4.6.2 4.6.3 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55°C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days
2-17 2-20 2-58 2-27 2-29 2-32
4.6.8 4.6.6 4.6.9 4.6.7
Vibration, sinusoidal* 2-6
Rapid change of temperature Dry heat Damp heat, cyclic* Cold Climatic sequence* Damp heat, steady state* Endurance tests - ageing - extended aging
2-14 2-2 2-30 2-1 1-7 2-3
4.6.5 4.6.14 4.6.15 4.6.16 4.6.17 4.6.18
4.7.1 4.7.2
30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C
GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany
AXIS45 page 2(2)
www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com
很抱歉,暂时无法提供与“AXIS45”相匹配的价格&库存,您可以联系我们找货