Specification AXLE20 Oscillator type : TCXO
Parameter
Frequency range Standard frequencies Frequency stability Initial tolerance vs. temperature in operating temperature range (steady state)
Issue: 03
Date: 2005-05-22
min.
9
typ.
max.
Unit
MHz MHz ppm ppm ppm ppm ppm ppm ppm ppm ppm V V % kΩ
Condition
33 10 / 16.384 /19.44 ±1 Frequency stability ± 2.5 ± 1.5 ± 0.8 ± 0.2 ± 0.2 ±1
@+25°C Temperature -40°~+85°C -20°~+70°C 0°~+50°C
Option I
“25” “15” “08”
vs. supply voltage variation vs. load change long term (aging) per year Frequency adjustment range Electronic Frequency Control (EFC) EFC voltage VC EFC slope (∆f / ∆VC) EFC linearity EFC input impedance RF output Signal waveform Load Amplitude Start-up time Phase noise @16.384 MHz
@ +40°C
±5 0.25 0.30 negative 100 Clipped Sinus 10 kΩ // 10 pF 0.8
4.75 3.0
Option II = ”50” Option II = ”33”
4 -85 -115 -130 -145 5.0 3.3
Supply voltage VS
Current consumption (steady state) mA °C Operable temperature range °C Storage temperature range mm IEC 61837 CO 30 Enclosure (see drawing) gram Weight IEC 60286-3 Packing V HBM as IEC 61000-4-2 ESD Sensitivity Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated 2. Overall frequency stability = initial tolerance + temp.stability + supply & load change + aging
5.25 3.47 5 -45 +90 -45 +90 19.1x13.1x5 max 5 Tape & reel 1500
4.75 3.13
V ms dBc dBc dBc dBc V
peak-to-peak 10 Hz 100 Hz 1000 Hz 10000 Hz Option II = ”50” Option II = ”33” @ +25°C
Ordering Code:
Model (Specification) AXLE20 Option I 25 Option II Frequency [MHz] 33 12.800
GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany
AXLE20 page 1(2)
www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com
Enclosure drawing
Pin connections
Pin # Symbol Function 1 VC Control Voltage (EFC) 2 GND Ground 4 RF OUT RF Output 5 VS Supply Voltage Other pins: Internal connections
Environmental conditions
Test Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* Bump* Free fall* IEC 60068 Part ... IEC 60679-1 clause ... 4.3 4.6.2 4.6.3 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55°C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days
2-17 2-20 2-58 2-27 2-29 2-32
4.6.8 4.6.6 4.6.9 4.6.7
Vibration, sinusoidal* 2-6
Rapid change of temperature Dry heat Damp heat, cyclic* Cold Climatic sequence* Damp heat, steady state* Endurance tests - ageing - extended aging
2-14 2-2 2-30 2-1 1-7 2-3
4.6.5 4.6.14 4.6.15 4.6.16 4.6.17 4.6.18
4.7.1 4.7.2
30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C
GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany
AXLE20 page 2(2)
www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com
很抱歉,暂时无法提供与“AXLE20”相匹配的价格&库存,您可以联系我们找货