Issue: 01 Date: 2005-02-01 Specification AXMW8596 Oscillator type : Crystal Controlled Microwave Oscillator
Parameter
Frequency range Standard frequencies Frequency stability Initial tolerance vs. temperature in operating frequency range (steady state) medium term (aging) over 24 hours Frequency selection Electronic Frequency Control RF output Signal waveform Load Load VSWR Output Power Output Power Variation
min.
typ.
max.
Unit
GHz ppm ppm ppm ppm
Condition
8.5 9.6 6 frequencies within 4% -50 -100 -1 50 100 1
@25°C -40°~+70°C @ constant temp. Note 2
By grounding of appropriate selection pin SINUS 50 1.5 50 2 3 2 50 90 65 -90 -75 -68 10 28.5 600 500 80 100 +85 TBD bulk 1500 V mW dB dB dB dB dBc dBc dBc Hz / g V mA mV % % °C mm gram
Ohm
Spurious Outputs (Note 1) AM Noise (Note 1) FM Noise (Note 1) Vibration Sensitivity Supply voltage VS Current consumption (steady state) Power line Ripple Noise (pk-pk) Relative Humidity Storage temperature range Enclosure L x W x H (see drawing) Weight Packing ESD Sensitivity
0°C ~ +70°C -30°C ~ +70°C between 6 frequencies Fc ± 5 MHz Outside fc ± 5 MHz fc ± 30 MHz ~60 MHz elsewhere fc ± 30 MHz ~60 MHz See graph 1
27.5
28.0
-55 100 x 70 x 30
50 Hz ~ 200 MHz Continuous During warm-up 95% R.H.
HBM as in IEC 610004-2
Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated 2. Channel selection by connecting ground (pin 7) to one of the 6 pins in Viking connector VR7/4AB13 The six nominated frequencies to be determined by the purchasing-order
GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany
AXMW 8596 page 1(5)
www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com
Enclosure drawing:
Pin connections:
VR7/4AB13 connector: Pin # Symbol Function 1 CH1 Channel 1 select 2 CH2 Channel 2 select 3 CH3 Channel 3 select 4 CH4 Channel 4 select 5 CH5 Channel 5 select 6 CH6 Channel 6 select 7 Ground SMA Connector: RF Output BNC Connector : VS Supply Voltage
Mounting plate:
Marking: AXMW8596
AXTAL ww/xx & serial number
Environmental conditions: Vibration : Specification must be met under the vibration conditions of the chart below (Graph 1).
Shock : Half Sine 15 g, 11 ms in 3 mutually perpendicular axes. No damage. Shock not applied to short term stability requirements
GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany
AXMW 8596 page 2(5)
www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com
Typical spectrum drawing 1:
Typical spectrum drawing 2:
* RBW 10 kHz * VBW 50 Hz
Ref
20
20 dBm
Att
45 dB
SWT 8 s
10 1 AP CLRWR
A
0
-10
-20
-30
-40
-50
-60
-70
-80
Center
9.07 GHz
200 kHz/
Span 2 MHz
AXTAL GmbH & Co. KG Wasemweg 5 D-74821 Mosbach
AXMW8596 page 3(5)
www.axtal.com info@axtal.com fon: +49 6261 939834 fax: +49 6261 939836
Ref 20 10 1 SA CLRWR
20 dBm PHN 17.616 dBm
Att
45 dB 1
RBW 20 kHz VBW 2 kHz SWT 50 ms
Delta 2 [T1 PHN] -91.37 dBc/Hz 99.358974360 kHz Marker 1 [T1 FXD] 17.66 dBm 9.015004397 GHz
A
0
-10
-20
-30 2 -40
-50
-60
-70 PHN -80 Center 9.015006 GHz 100 kHz/ Span 1 MHz
RBW 3 MHz Ref
20
20 dBm
Att
45 dB
VBW 300 kHz SWT 155 ms
Marker 1 [T1 ] -39.28 dBm 500.000000000 MHz
10 1 AP CLRWR
A
0
-10
-20
-30
1
-40
-50
-60
-70
-80
Center
13.25 GHz
2.65 GHz/
Span 26.5 GHz
AXTAL GmbH & Co. KG Wasemweg 5 D-74821 Mosbach
AXMW8596 page 4(5)
www.axtal.com info@axtal.com fon: +49 6261 939834 fax: +49 6261 939836
Typical PLL settling time during switch from channel 1 to channel 6:
Typical PLL settling time during switch from channel 6 to channel 1:
Typical PLL settling time during switch from channel 2 to channel 3:
AXTAL GmbH & Co. KG Wasemweg 5 D-74821 Mosbach
AXMW8596 page 5(5)
www.axtal.com info@axtal.com fon: +49 6261 939834 fax: +49 6261 939836