Specification Oscillator type :
Issue: 02 Date: 2006-03-18 AXX2016 Quartz Crystal Unit in SMD package 2.0x1.6 mm RoHS compliant
Parameter
Frequency range Actual frequency f0 Crystal cut / Vibration mode Load capacitance CL Overtone Adjustment tolerance Frequency stability Frequency stability over temperature range operating temperature range (steady state)
min. typ. max. Unit
20 80 MHz MHz AT 8 pF, 10 pF or Series 1 ±15 / ±20 / ±50/ ±100 ppm ppm ± 10 ~ ± 100 ppm 0 +50 °C -10 +60 °C -20 +70 °C -40 +85 °C ±5 ppm 200 Ω 100 Ω 60 Ω fF 5 pF 20 100 µW 500 MΩ -40 +85 °C 2.0 x 1.6 x 0.5 Frequency (MHz) + Date Code Tape & Reel
Condition
@ 25°C +-5°C Overall (Note 1) See table below
long term (aging) Resonance resistance Rr
@ 20 ~ 25 MHz @ >25 ~ 40 MHz @ >40 ~ 80 MHz
Motional capacitance C1 Static capacitance C0 Drive level Insulation resistance Storage temperature range Enclosure (see drawing) marking
100 V DC IEC 61637
IEC 60286-3 Packing Notes: 1. Overall frequency stability = initial tolerance + temp. stability + aging (1st year) 2. Terminology and test conditions are according to IEC standard IEC60122-1, unless otherwise stated 3. Measurement technique according to IEC 60444-5 or equivalent
Frequency vs. Temperature Stabilities 0° ~ +50°C ± 10 ppm ± 30 ppm ± 50 ppm ± 100 ppm -10° ~ +60°C ± 15 ppm ± 30 ppm ± 50 ppm ± 100 ppm -20° ~ +70°C ± 20 ppm ± 30 ppm ± 50 ppm ± 100 ppm -40 ~ +85°C ± 30 ppm ± 50 ppm ± 100 ppm
GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany
AXX2016 page 1(2)
www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com
Enclosure drawing
Environmental conditions
Test Visual inspection, dimensions Sealing tests Solderability Resistance to soldering heat Shock Bump Free fall Vibration, sinusoidal IEC 60068 Part ... IEC 61178-1 clause ... 4.5 4.6 4.8.2 4.8.3 Test conditions Enclosure styles as in IEC 60122-3, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz 1 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55°C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.8.11, 4.8.12 (1st cycle), 4.8.13, 4.8.12 (5 cycles) Test Ca, 56 days
2-17 2-20
2-27 2-29 2-32 2-6
4.8.8 4.8.6 4.8.9 4.8.7
Rapid change of temperature Dry heat
2-14 2-2
4.8.5 4.8.11
Damp heat, cyclic Cold
2-30 2-1
4.8.12 4.8.13
Climatic sequence Damp heat, steady state Endurance tests - ageing - extended aging
1-7 2-3
4.8.14 4.8.15
4.9.1 4.9.2
30 days @ 85°C 1000h, 2000h, 8000h @85°C
GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany
AXX2016 page 2(2)
www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com
很抱歉,暂时无法提供与“AXX2016”相匹配的价格&库存,您可以联系我们找货
免费人工找货