AZ166-1CT-48D

AZ166-1CT-48D

  • 厂商:

    AZETTLER

  • 封装:

  • 描述:

    AZ166-1CT-48D - MINIATURE POWER RELAY - American Zettler, Inc.

  • 详情介绍
  • 数据手册
  • 价格&库存
AZ166-1CT-48D 数据手册
AZ166 MINIATURE POWER RELAY FEATURES • • • • • • • Top panel mount SPDT through 4PDT arrangement High switching capacity AC and DC coils CE marked UL, CUR file E43203 TÜV pending CONTACTS Arrangement SPDT (1 Form C) DPDT (2 Form C) 3PDT (3 Form C) 4PDT (4 Form C) See chart on page 2 See chart on page 2 5 VDC, 0.1 A -1CT contact -2C and 2CT contact -3C contact -4C contact Silver Silver Silver Silver cadmium oxide cerium cerium cerium GENERAL DATA Life Expectancy Mechanical Electrical Operate Time Release Time Minimum operations 2 x 107 operations See UL/CUR ratings on page 2 25 msec max. at nominal coil voltage 25 msec at nominal coil voltage (without suppression) Ratings UL, CUR Minimum Load Material Dielectric Strength 1500 Vrms coil to contact (at sea level for 1 min.) 1000 Vrms contact to contact 1000 Vrms between contact sets Insulation Resistance Dropout Ambient Temperature Operating Storage Vibration 100 megohms min. at 20°C, 500 VDC, 50% RH DC: > 10% of nominal coil voltage AC: > 30% of nominal coil voltage -55°C (-67°F) to 70°C (158°F) -55°C (-67°F) to 105°C (221°F) 0.062" DA at 10–55 Hz 20g Polycarbonate Plug-in 250°C (482°F) 5 seconds 37 grams Resistance < 50 milliohms initially (24 V, 1 A voltage drop method) COIL Power At Pickup Voltage (typical) Max. Continuous Dissipation Temperature DC: 576 mW, 6 to 48 VDC 704 mW, 110 VDC AC: .768 VA DC: 1.2 W (110 V : 1.5 W) at 20°C (68°F) AC: 1.7 VA at 20°C (68°F) 105°C (221°F) Shock Enclosure Terminals Max. Solder Temp. Max. Solder Time Weight NOTES 1. All values at 20°C (68°F). 2. Relay may pull in with less than “Must Operate” value. 3. Specifications subject to change without notice. 8/11/03W AZ166 CONTACT RATINGS Maximum Ratings SPDT Heavy duty, resistive load: Max. Switched Power: 450 W, 3750 VA Max. Switched Current: 15 A Max. Switched Voltage: 30 VDC, 250 VAC DPDT Heavy duty, resistive load: Max. Switched Power: 300 W, 2500 VA Max. Switched Current: 10 A Max. Switched Voltage: 30 VDC, 250 VAC DPDT Standard duty, resistive load: Max. Switched Power: 210 W, 1750 VA Max. Switched Current: 7 A Max. Switched Voltage: 30 VDC, 250 VAC 3PDT, 4PDT, Standard duty, resistive load: Max. Switched Power: 150 W, 1250 VA Max. Switched Current: 5 A Max. Switched Voltage: 30 VDC, 250 VAC UL/CUR Ratings SPDT Heavy duty: 15 A, 250 VAC 100k, Resistive 15 A, 30 VDC, 100k N.O., 30k N.C., Resistive DPDT Heavy duty: 10 A, 250 VAC, 100k, General use 10 A, 30 VDC, 100k, Resistive 1/3 HP, 120/240 VAC, 100k Motor load DPDT, Standard duty: 7A, 250 VAC, 100k Resistive 7A, 30 VDC, 100k, Resistive 3A, 240 VAC/30 VDC, 100k, General use 3PDT, 4PDT, Standard duty: 5A, 250 VAC, 100k, Resistive 5A, 30 VDC, 100k, Resistive 3A, 240 VAC/30 VDC, 100k, General use MECHANICAL DATA AZ166-_C .047 [1.2] .098 [2.5] .846 [21.5] .138 [3.5] .846 [21.5] ø.098 [ø2.5] AZ166-_CT .197 [5.0] .138 [3.5] 1.378 [35.0] .209 [5.3] .134 [3.4] 1.102 [28.0] 1.496 [38.0] 1.693 [43.0] .098 [2.5] .252 [6.4] 1.378 [35.0] 1.102 [28.0] 1.496 [38.0] 1.693 [43.0] .098 [2.5] .020 [0.5] .020 [0.5] .079 [2.0] .079 [2.0] WIRING DIAGRAM 1 5 9 2 6 10 3 7 11 4 8 12 1 4 7 13 2 5 8 3 6 9 14 1 5 9 13 4 8 12 14 7 1 3 5 2 4 6 Viewed Towards Terminal 1 4 7 2 5 8 3 6 9 1 5 9 4 8 12 1 3 5 2 4 6 1 3 5 2 4 6 1 3 5 2 4 6 1 5 9 2 6 10 3 7 11 4 8 12 13 14 8 7 8 13 14 13 14 13 14 7 8 7 8 4C 4C 3C 2C 2CT 1CT + 3C + 2C + 2CT + 1CT + WITH LED TERMINAL LAYOUTS .169 [4.3] .161 [4.1] Viewed Towards Terminal .226 [5.7] .520 [13.2] .173 [4.4] .169 [4.3] .163 [4.1] .520 [13.2] .161 [4.1] .260 [6.6] .163 [4.1] .169 [4.3] .161 [4.1] .520 [13.2] .163 [4.1] .394 [10.0] .156 [4.0] .181 [4.6] .661 [16.8] .409 [10.4] .661 [16.8] .409 [10.4] .409 .661 [10.4] [16.8] .417 [10.6] .699 [17.75] .559 [14.2] 4C 3C 2C 1CT & 2CT 8/11/03W AZ166 RELAY ORDERING DATA STANDARD RELAYS: DC Coil COIL SPECIFICATIONS Nominal Coil VDC 5 6 12 24 48 110 Must Operate VDC 4.0 4.8 9.6 19.2 38.4 88.0 Max. Continuous VDC 5.5 6.6 13.2 26.4 52.8 121.0 Nominal Current mA ± 10% 181.0 150.0 75.0 36.9 18.5 10.0 Coil Resistance 27.5 ± 10% 40.0 ± 10% 160 650 2600 11,000 ± 10% ± 10% ± 15% ± 15% ORDER NUMBER* AZ166–2C–5D AZ166–2C–6D AZ166–2C–12D AZ166–2C–24D AZ166–2C–48D AZ166–2C–110D STANDARD RELAYS: AC Coil (50/60 Hz) COIL SPECIFICATIONS Nominal Coil VAC 6 12 24 48 120 220 240 Must Operate VAC 4.8 9.6 19.2 38.4 96.0 176.0 192.0 Max. Continuous VAC 7.1 14.3 28.6 57.1 143.0 261.0 288.0 Nominal Current mA ± 10% 200.0 100.0 50.0 25.0 10.0 5.5 5.0 Coil Resistance 11.5 ± 10% 46.0 ± 10% 184 735 4,550 14,400 22,000 ± 10% ± 10% ± 10% ± 15% ± 15% ORDER NUMBER* AZ166–2C–6A AZ166–2C–12A AZ166–2C–24A AZ166–2C–48A AZ166–2C–120A AZ166–2C–220A AZ166–2C–240A * For 3PDT or 4PDT substitute “-3C” or “-4C” for “-2C”. For LED add “1” to the end of p/n. RELAY ORDERING DATA HEAVY DUTY RELAYS: DC Coil COIL SPECIFICATIONS Nominal Coil VDC 5 6 12 24 48 110 Must Operate VDC 4.0 4.8 9.6 19.2 38.4 88.0 Max. Continuous VDC 5.5 6.6 13.2 26.4 52.8 121.0 Nominal Current mA ± 10% 181.0 150.0 75.0 36.9 18.5 10.0 Coil Resistance 27.5 ± 10% 40.0 ± 10% 160 650 2600 11,000 ± 10% ± 10% ± 15% ± 15% ORDER NUMBER* AZ166–1CT–5D AZ166–1CT–6D AZ166–1CT–12D AZ166–1CT–24D AZ166–1CT–48D AZ166–1CT–110D HEAVY DUTY RELAYS: AC Coil (50/60 Hz) COIL SPECIFICATIONS Nominal Coil VAC 6 12 24 48 120 220 240 Must Operate VAC 4.8 9.6 19.2 38.4 96.0 176.0 192.0 Max. Continuous VAC 7.1 14.3 28.6 57.1 143.0 261.0 288.0 Nominal Current mA ± 10% 200.0 100.0 50.0 25.0 10.0 5.5 5.0 Coil Resistance 11.5 ± 10% 46.0 ± 10% 184 735 4,550 14,400 22,000 ± 10% ± 10% ± 10% ± 15% ± 15% ORDER NUMBER* AZ166–1CT–6A AZ166–1CT–12A AZ166–1CT–24A AZ166–1CT–48A AZ166–1CT–120A AZ166–1CT–220A AZ166–1CT–240A * For DPDT substitute “-2CT” for “-1CT”. For LED add “1” to the end of p/n. 8/11/03W
AZ166-1CT-48D
### 物料型号 - 型号:AZ166

### 器件简介 - 特点:顶面安装、SPDT至4PDT的切换、高切换能力、适用于交流和直流线圈、CE标记、UL和CUR文件E43203、TÜV待定。

### 引脚分配 - SPDT (1 Form C):单刀双掷 - DPDT (2 Form C):双刀双掷 - 3PDT (3 Form C):三刀双掷 - 4PDT (4 Form C):四刀双掷

### 参数特性 - 最小负载:5 VDC, 0.1 A - 材料:1CT接触-银镉氧化物、2C和2CT接触-银铈、3C接触-银铈、4C接触-银铈 - 电阻:初始小于50毫欧姆(24V,1A电压降法)

### 功能详解 - 线圈功率: - 接通电压(典型):DC: 0.4 mW, 110VDC AC: 0.768VA - 最大连续耗散:DC: 1.2 W(110 V:1.5 W) at 20°C、AC: 1.7 VA at 20°C - 温度:105°C - 寿命:机械电气最小操作2x10^7次操作,详见UL/CUR等级 - 操作时间:最大25毫秒在额定线圈电压下 - 释放时间:25毫秒在额定线圈电压下(无抑制) - 耐压:1500 Vrms线圈至接触、1000 Vrms接触至接触、1000 Vrms接触集之间 - 绝缘电阻:最小100兆欧姆在20°C, 500 VDC, 50% RH - Dropout:DC:> 10%的额定线圈电压、AC:> 30%的额定线圈电压 - 环境温度:操作-55°C至70°C、存储-55°C至105°C - 振动:0.062"DA在10-55Hz - 冲击:20g - 外壳:聚碳酸酯 - 端子:插入式 - 最大焊接温度:250°C - 最大焊接时间:5秒 - 重量:37克

### 应用信息 - 最大额定值: - SPDT重型、电阻负载:最大切换功率450W, 3750VA、最大切换电流15A、最大切换电压30VDC, 250VAC - DPDT重型、电阻负载:最大切换功率300W, 2500VA、最大切换电流10A、最大切换电压30VDC, 250VAC - DPDT标准负载、电阻负载:最大切换功率210W, 1750VA、最大切换电流7A、最大切换电压30VDC, 250VAC - 3PDT, 4PDT, 标准负载、电阻负载:最大切换功率150W, 1250VA、最大切换电流5A、最大切换电压30VDC, 250VAC

### 封装信息 - 封装材料:聚碳酸酯 - 端子类型:插入式 - 最大焊接温度:250°C - 最大焊接时间:5秒 - 重量:37克
AZ166-1CT-48D 价格&库存

很抱歉,暂时无法提供与“AZ166-1CT-48D”相匹配的价格&库存,您可以联系我们找货