SGX-41F
SOLID STATE RELAY 4 AMPS 48 TO 400 VRMS
FEATURES • • • • • • • • Photo isolation Up to 800V blocking voltage Both zero cross or random turn-on High surge capability Built-in snubber UL, CUR file E43203 SCR or Triac Output Circuitry RoHS compliant
INPUT Type
Control Voltage Range Turn On Voltage Turn Off Voltage Max. Input Current Max. Reverse Voltage 1D 3 to 15 VDC 3 VDC max. 1 VDC min. 40 mA at 15 VDC -15 VDC 2D 15 to 32 VDC 15 VDC max. 1 VDC min. 20 mA at 32 VDC -32 VDC
OUTPUT
Type Output Voltage Range Blocking Voltage Max. Leakage Current (off) Max. Voltage Drop (at rated current) Min. Load Current Max. Turn-On Time 240 48 to 264 VAC 600 Vpk 5 mA 1.7 VRMS 100 mA Random Turn On (DC input): 1 ms Zero Cross Turn On (DC input): 1/2 cycles + 1 ms AC Input: 20 ms DC Input: 1/2 cycle + 1 ms AC Input: 40 ms Triac: 200 V/us / SCR: 500 V/us 380 48 to 400 VAC 800 Vpk 5 mA
Max. Turn-Off Time
Min. Off-State (dv/dt)
GENERAL
Dielectric Strength Insulation Resistance Ambient Temperature 4000 Vrms min. (at 50/60 Hz, 1 min.) 1000 Min. (at 500 VDC) Operating: -30°C (-22°F) to 80°C (176°F) Storage: -30°C (122°F) to 100°C (212°F) Termination Weight PCB 15g
3/29/06W
SGX-41F
RELAY ORDERING DATA SGX-41F
MODEL
1D
INPUT VOLTAGE 1D: 3 TO 15 Vdc 2D: 15 to 32 Vdc
240
OPERATING VOLTAGE RANGE 240:48 TO 264 Vac 380: 48 to 400 Vac
A
LOAD TYPE A: AC LOAD
4
LOAD CURRENT 4: 4A
Z
S
G
PACKAGE G: epoxy
ZERO CROSS OUTPUT DEVICE OR RANDOM Z: Zero cross turn on P: Random turn on S: SCR Nil: Triac
MECHANICAL DATA
Outline Dimensions PC Board Layout
1.724MAX [43.8]
.374MAX [9.5]
.100 [2.54] .200 [5.08]
Ø0.047 [1.2]
1.043MAX [26.5MAX]
.118MAX [3.0]
0.200 [5.1] .370 [9.4]
.201 [5.1] Ø.039 [1.0]
0.700 [17.8] 1.100 [27.9]
.701 [17.8] 1.098 [27.9]
.098MAX [2.5]
Wiring Diagram
-4
+3
2
1
Load Input control Power supply
Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010"
INSTALLATION
1. When mounting the relays side by side, provide a space equivalent to the width of a single SSR between two adjacent SSRs. Otherwise, reduce the load current flow to 1/2 to 1/3 of the rated current.
PRECAUTIONS
1. Before connecting a load that generates a high surge current, such as a lamp load to the SSR, make sure that the SSR can withstand the surge current of the load. The product data sheet shows the non-repetitive peak value of the surge current that flows through the SSR. Normally, use 1/2 of the non-repetitive peak surge current as the standard value. If a surge current exceeding that value is expected, connect a quick-blowing fuse to protect the SSR.
2.
3/29/06W
SGX-41F
CHARACTERISTIC CURVES
Figure 1 Maximum load current vs. ambient temperature
3/29/06W