VRLA Rechargeable Battery
Measures
HR50-12
FEATURES
Technology
Values
Innovation
APPLICATION
UPS
Wheelchairs
Golf-Carts
Maintenance free(no water topping-up required).
No free acid(Non-spillable battery).
Low self-discharge rate, lower than 3% capacity loss per month.
Can be used in any orientation(excluding used inverted).
The battery is designed for high rate usage.
Absorbent Glass Mat technology for efficient gas recombination.
The power density at 5 min~15min discharging rate is 30% higher
than BP series.
SPECIFICATIONS
Nominal Voltage
Nominal Capacity
Approx. Weight
Terminals
Internal Resistance
Max. Discharge Current
Max. Charge Current
12 V
48Ah @ 10 hour rate F.V.(1.75V/cell)
15.3Kg(33.74lbs.)
B2 (Fitting M5 bolt & nut) , I1 and I2 are optional
Operating Temperature Range
Charge 0oC~40oC(32oF~104oF)
Discharge -20oC~50oC(-4oF~122oF)
Storage. -20oC~40oC(-4oF~104oF)
Container Material
Standard: ABS( UL 94-HB) HR50-12
Optional: Flame Retardant ABS(UL 94-V0) HR50-12FR
5m (Fully Charged )
600 A (5 sec.)
14.4 A
DIMENSION(mm/inch)
OUTER DIMENSIONS
IEC 61056-1
JIS C 8702-1
GB/T 19639.1
TERMINAL TYPE
Length
Total Height
171±1.5 (6.73±0.06)
[M5 BOLT & NUT]
o
1.80V
1.70V
1.60V
1.50V
1.40V
1.30V
o
Unit: W
1.80V
1.70V
1.60V
1.50V
1.40V
1.30V
[M6 BOLT]
5 Min
10 Min
15 Min
20 Min
30 Min
40 Min
50 Min
60 Min
120 Min
1400.0
1014.0
865.0
658.0
500.0
418.0
368.0
202.8
2450.0
1563.0
1103.0
916.0
685.0
519.0
431.0
376.0
206.7
2625.0
1644.0
1153.0
950.0
700.0
531.0
440.0
383.0
210.0
2700.0
1675.0
1178.0
965.0
709.0
538.0
445.0
386.0
211.1
2750.0
1698.0
1191.0
974.0
714.0
541.0
449.0
389.0
211.7
2775.0
1713.0
1200.0
980.0
718.0
544.0
451.0
390.0
212.2
o
Constant current discharge characteristics at 25 C/77 F
F.V.
(V/cell)
[M5 BOLT & NUT]
2050.0
o
Discharge
Time
M6x1.0
Terminal Hardware Initial Torque: B2/ I1(4.0Nm±5%),I2(5.5Nm±5%)
Constant power discharge characteristics at 25 C/77 F
F.V.
(V/cell)
2.0(0.08)
171 1.5(6.73 0.06)
165 1.5(6.50 0.06)
5.5(0.22)
197 1.5(7.76 0.06)
Container Height
171±1.5 (6.73±0.06)
Terminal I2
M5x0.8
5.2(0.20)
17.0(0.67)
7.5(0.30)
15.0(0.59)
165±1.5 (6.50±0.06)
Discharge
Time
Terminal I1
Terminal B2
2.0(0.08)
197±1.5 (7.76±0.06)
Width
5 Min
10 Min
15 Min
183.04
122.81
87.72
222.73
137.11
95.42
238.64
144.21
245.45
20 Min
W
Unit: A
30 Min
40 Min
50 Min
60 Min
120 Min
74.19
55.76
42.05
34.98
30.67
16.90
78.56
58.05
43.65
36.07
31.33
17.23
99.74
81.48
59.32
44.66
36.82
31.92
17.50
146.93
101.90
82.76
60.08
45.25
37.24
32.17
17.59
250.00
148.95
103.03
83.53
60.51
45.50
37.57
32.42
17.64
252.27
150.26
103.81
84.05
60.85
45.75
37.74
32.50
17.68
All data and artworks shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto.
A/2
REV. Jun. 2013
Powered by
B.B. Battery Co., Ltd.
很抱歉,暂时无法提供与“HR50-12-B2”相匹配的价格&库存,您可以联系我们找货