G40C120CTFW
REVERSE VOLTAGE
FORWARD CURRENT
TRENCH SCHOTTKY RECTIFIER
– 120 Volts
– 40 Amperes
ITO-220(S)AB
FEATURES
• High efficiency
• Reduced high temperature reverse leakage
• Reduced ultra-low forward voltage drop
• Qualification is according to AEC-Q101 Rev_C
ITO-220(S)AB
DIM
MIN
MAX
A
14.95
15.95
B
10.00
10.40
C
2.76
3.36
D
8.50
8.80
E
2.10
2.50
F
13.00
13.70
G
1.15
1.37
H
2.40
2.70
I
0.50
0.80
J
0.45
0.70
K
3.00
3.30
L
4.46
4.87
M
2.48
2.80
N
2.50
2.80
All dimension in millimeter
APPLICATION
• DC to DC converter
• AC to DC Adaptors
MECHANICAL DATA
• Case: JEDEC TO-220ABFP
• Case Material: “Green” molding compound, UL
flammability classification 94V-0,(No Br. Sb. Cl.)
“Halogen-free”.
• Lead free finish, RoHS compliant
• Weight: 1.558 grams (Approximate)
• Marking code: G40C120CTFW
P IN 1
P IN 2
P IN 3
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
ABSOLUTE RATINGS
SYMBOL
VALUE
UNIT
Maximum repetitive peak reverse voltage
PARAMETER
VRRM
120
V
Maximum DC blocking voltage
VDC
120
V
I(AV)
40
A
IFSM
250
A
TJ, TSTG
-55 ~ +150
°C
Maximum Average rectified output current
@TC=20°C
Peak forward surge current 8.3ms single half sine-wave
superimposed on rated load.
Operating junction and Storage Temperature range
STATIC ELECTRICAL CHARACTERISTICS
PARAMETER
TEST CONDITIONS
Forward voltage (Note1)
IF=20A
TJ=25°C
TJ=125°C
Leakage current
VR=120V
TJ=25°C
TJ=125°C
Typical junction capacitance (Note 2)
SYMBOL
TYP
MAX
UNIT
VF
-0.74
0.98
0.75
V
IR
-5.71
50
25
uA
mA
CJ
510
pF
SYMBOL
TYP
UNIT
RthJC
4.2
RthJL
3.2
THERMAL CHARACTERISTICS
PARAMETER
Typical thermal resistance (Note 3,4)
Note :
(1)
(2)
(3)
(4)
300us pulse width, 2% duty cycle.
Measured at 1.0MHz and applied voltage of 4.0V DC.
Thermal resistance test performed in accordance with JESD-51.
The unit mounted on fin-type heatsink ( 75mm x 100mm x 26.8mm ) with copper heatsink ( 19.9mm x 12.1 mm x
12.6mm) in free air condition
.
°C/W
REV-0 , May-2018, KTHC190
RATING AND CHARACTERISTIC CURVES
G40C120CTFW
FIG.2 MAXIMUM NON-REPETITIVE SURGE CURRENT
FIG.1 FORWARD CURRENT DERATING CURVE
PEAK FORWARD SURGE CURRENT,(A)
AVERAGE FORWARD CURRENT, (A)
50
40
30
20
10
0
0
25
50
75
100
125
300
250
8.3ms single half sine-wave
200
150
100
50
0
150
1
FIG.3 TYPICAL FORWARD CHARACTERISTICS
10000
1000
10
CAPACITANCE, (pF)
INSTANTANEOUS FORWARD CURRENT,
(A)
100
FIG.4 TYPICAL JUNCTION CAPACITANCE
100
TJ =150°C
TJ =0°C
1
TJ =25°C
100
TJ =25°C, f=1MHz, level =1V
10
TJ =100°C
TJ=125°C
0.1
1
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
FIG.5 TYPICAL REVERSE CHARACTERISTICS
100000
TJ =150°C
10000
1000
TJ =125°C
100
TJ =100°C
10
TJ =25°C
1
TJ =0°C
0.1
0.01
0
24
48
72
96
RATED PEAK REVERSE VOLTAGE, (V)
120
0.1
1
10
REVERSE VOLTAGE, (V)
INSTANTANEOUS FORWARD VOLTAGE, (V)
INSTANTANEOUS REVERSE CURRENT,
(uA)
10
NUMBER OF CYCLES AT 60Hz
CASE TEMPERATURE, ( °C)
144
100
LEGAL DISCLAIMER NOTICE
Important Notice and Disclaimer
LSC reserves the right to make changes to this document and its products and specifications at
any time without notice. Customers should obtain and confirm the latest product information and
specifications before final design, purchase or use.
LSC makes no warranty, representation or guarantee regarding the suitability of its products for
any particular purpose, nor does LSC assume any liability for application assistance or
customer product design. LSC does not warrant or accept any liability with products which are
purchased or used for any unintended or unauthorized application.
No license is granted by implication or otherwise under any intellectual property rights of LSC.
LSC products are not authorized for use as critical components in life support devices or
systems without express written approval of LSC.
很抱歉,暂时无法提供与“G40C120CTFW”相匹配的价格&库存,您可以联系我们找货
免费人工找货