0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PT8A3362SE

PT8A3362SE

  • 厂商:

    BCDSEMI(美台)

  • 封装:

    SOIC24

  • 描述:

    HEATER CONTROLLER SO-24

  • 数据手册
  • 价格&库存
PT8A3362SE 数据手册
||||||||||||||||||||||||||||||||||||||||||||||||||| PT8A3361/62/63/64 |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| NTC+LCD Heating Controller Features Description  LCD screen showing temperature setting The PT8A336x is a mixed signal CMOS LSI chip  Dual Temperature (Fahrenheit/Centigrade) Display designed as heating controller with help of external NTC  Backlights indicating work status (Negative  Auto temperature control with NTC  protection is implemented for device safety and 11 8 and 11 temperature levels option  Three keys: On/Off, Up and Down  NTC open protection  Pulse trigger for high current SCR/TRIAC (up to 15mA) Temperature Component). NTC open temperature levels. It can drive TRIAC or SCR directly. It has 3 keys function setting. LCD displays and backlight indicate the working status. This device can be used in both 120V and 240V power  1 hour auto power off. line supplier, as it will automatically adjust the heating  Dual Voltage (120V/240V) operations power according to the power line voltage to avoid  Internal 5V zener heating appliance damage or long heating time.  Lead free and Green QFN-24, TSSOP-24 and The PT8A336x build-in timer will be auto-power off SOIC-24 package; Lead free DIP-24 package after power on 1 hour both 60Hz and 50Hz. Applications  Heating Controller Block Diagram 12-07-0006 PT0356-1 1 07/06/12 PT8A3361/62/63/64 NTC+LCD Heating Controller |||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| Pin Information Pin Configuration PT8A3361/62/63/64 Pin Description Pin No. Name Type Description 1, 19 SEL2,SEL1 I Select temperature setting: 00: 100C~200C; 01: 130C~230C;10: 120C~220C; 11: 160C~230C. O LCD digits control output. O LCD digits control output. O Internal pull up, default for LCD shows C; Low level: LCD shows F. 7 SEG1,SEG2, SEG3,SEG4, SEG5,SEG6, COM1,COM2 COM3,COM4 C/F 8 NTC1 I NTC voltage input, NTC open detection input. 9 NTC2 O Output signal for NTC open detection. 10 GND Power 11 CLK I Clock input from power line. 12 K2 I Power on/off key inputs. 13 K1 I Up and down key inputs. 14 VDD Power 15 GATE O TRIAC and SCR trigger output. 16 BL1 O Drive LCD backlight. 17, 18 NC - No connection. 20, 21, 22, 24, 23, 2 3,4,5,6 Ground. Power. 12-07-0006 PT0356-1 2 07/06/12 PT8A3361/62/63/64 NTC+LCD Heating Controller |||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| Maximum Ratings Storage Temperature ................................................................................... -55oC to +150oC Supply Voltage to Ground Potential (Input & VDD Only)........................-0.5V to +6.5V Supply Voltage to Ground Potential (Output s Only) ...............................-0.5V to +6.5V DC Input Voltage .............................................................................................-0.5V to +6.5V Input/Output Current ................................................................... 50mA Input/Output Current (Pin VDD only) ...................................... 200mA Power Dissipation ......................................................................................................... 500mW Note: Stresses greater than those listed under MAXIMUM RATINGS may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. Recommended operation conditions Sym Parameter Min Typ Max Unit VDD TA Operating Voltage Operating temperature 4.0 -20 - VZ 85 V °C Electrical Characteristics (VDD = 4.0~Vz, TA = -20 ~ 85ºC, unless otherwise noted) DC Input Characteristics Symbol VNTCADC Description Voltage of ADC Test Conditions Step Step 0 Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Step 11 Step 12 Step 13 Step 14 Pin:NTC1 Step 15 VDD=4.5V Step 16 Step 17 Step 18 Step 19 Step 20 Step 21 Step 22 Step 23 Step 24 Step 25 Step 26 Step 27 Step 28 Step 29 Step 30 Step 31 Temp(ºC) 25 50 75 90 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 234 Min Type Max Unit 0.08 0.2375 0.575 0.8675 1.089 1.2163 1.33 1.45 1.5875 1.70 1.81 1.93 2.05 2.17 2.25 2.3525 2.43 2.52 2.60 2.645 2.72 2.79 2.8450 2.89 2.94 2.98 3.0133 3.0472 3.08 3.116 3.138 3.16 0.09 0.2475 0.585 0.8775 1.099 1.2263 1.34 1.46 1.5975 1.71 1.82 1.94 2.06 2.16 2.26 2.35 2.44 2.53 2.61 2.655 2.73 2.80 2.8550 2.9 2.95 2.99 3.0233 3.0572 3.09 3.126 3.148 3.17 0.1 0.2575 0.595 0.8875 1.109 1.2363 1.35 1.47 1.6075 1.72 1.83 1.95 2.07 2.17 2.27 2.3725 2.45 2.54 2.62 2.665 2.74 2.81 2.8650 2.91 2.96 3.0 3.0333 3.0672 3.1 3.136 3.158 3.18 V To be continued 12-07-0006 PT0356-1 3 07/06/12 PT8A3361/62/63/64 NTC+LCD Heating Controller |||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| Continued Symbol Description IIH IIL Input high current Input low current Test Conditions VIN = VDD, VCLK=GND Pin:K1 VIN = VDD, VCLK=VDD Pin: C/F, SEL2, VIN = VDD SEL1 Pin: K2 VIN = VDD Pin: CLK VIN = VDD Pin:NTC1 VIN = VDD VIN =VDD ,Output High Pin:NTC2 impedance VIN = GND, VCLK =-1V Pin:K1 VIN = GND, VCLK =1V Pin: C/F VIN = GND Pin:K2 SEL1, VIN = GND SEL2 VIN = GND Pin: CLK VIN =-0.35V Pin:NTC1 VIN = GND VIN = GND, Output High Pin:NTC2 impedance Min - Type - Max 60 5 Unit - - 5 A - - 80 1 100 A A nA - - 100 nA - - -5 -60 -50 A - - -5 A - - -5 -10 -100 A A nA -10 - -100 nA A A DC Output Electrical Characteristics Symbol IOH Description Test Conditions Pin: GATE Output High Current Pin: BL1, BL2, BL3 Pin: GATE IOL VLCD Output Low Current Output High Voltage Pin: BL Pin:COM1,COM2, COM3, COM4, SEG1, SEG2, SEG3, SEG4, SEG,5,SEG6, VDD = 4.5V VOUT = 2.5V VDD =4.5V VOUT =4.0V VDD = 4.5V VOUT =0.5V VDD =4.5V VOUT =0.5V Level3 Level2 VDD = 4.5V Level1 Min Type Max -15 - - -3.0 - - 4.0 - - 4.0 - - 0.54VDD 0.6VDD 0.66VDD 0.36VDD 0.4VDD 0.44VDD 0.18VDD 0.2VDD 0.22VDD Unit mA mA Power Supply Characteristics Symbol VPOR IDD VDD VZ TPOoff Description Voltage of POR Current consumption Supply voltage Voltage of Zener Power off timer Test Conditions No loading, V DD =4.5V Control function normal IDD=1mA ~20mA FCLK= 50Hz/60Hz 12-07-0006 Min 2 4.0 4.5 55 Type 5.0 60 Max 3 800 VZ 5.5 65 PT0356-1 4 Unit V A V V Minute 07/06/12 PT8A3361/62/63/64 NTC+LCD Heating Controller |||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| Line Clock Synchronization Characteristics Symbol Description VT_CLK Input Threshold Voltage of CLK Pin FCLK Frequency of CLK Test Conditions Level2 VTL_Level1 VDD =4.5V VT_Level2 is high VTH_Level1 VTL_Level1 VDD =4.5V VT_Level2 is low VTH_Level1 VTL_Level2 VDD =4.5V VT_Level2 is high VTL_Level2 VTL_Level2 VDD =4.5V VT_Level2 is high VTL_Level2 - Min 1.7 -200 -100 -125 -40 105 210 70 145 - Type 1.88 -250 -150 -175 -90 145 250 90 185 50/60 Max 2.1 -300 -200 -225 -140 185 290 110 225 - Unit V Test Conditions TA=25 ºC, VDD = 4.5V VDD = 4.0 ~ Vz TA = -20 ~ 85ºC Min 291 Type 300 Max 309 Unit s 285 - 315 s mV Hz GATE Pulse Characteristics Symbol Tal_Gate Description Width of Gate trigger pulse 12-07-0006 PT0356-1 5 07/06/12 PT8A3361/62/63/64 NTC+LCD Heating Controller |||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| Function Description The PT8A336x is a mixed signal CMOS LSI chip designed as heating controller with help of external NTC (Negative Temperature Component). NTC open protection is implemented for device safety and 11 temperature levels 100℃, 110℃, 120℃, 130℃, 140℃, 150℃, 160℃, 170℃, 180℃, 190℃, 200℃. It can drive TRIAC or SCR directly. It has 3 keys function setting. LCD displays and backlight indicate the working status. This device can be used in both 120V and 240V power line supplier, as it will automatically adjust the heating power according to the power line voltage to avoid heating appliance damage or long heating time. The PT8A3361/2/3/4 build-in timer will be auto-power off after power on 1 hour both 60Hz and 50Hz. Temperature setting is as below: Pin C/F is pulled to low level. Unit: F For PT8A3361/2/3/4: Pin1:SEL2 Pin19:SEL1 Level1 Level2 Level3 Level4 Level5 Level6 Level7 Level8 Level9 Level10 Level11 0 0 210 230 250 265 285 300 320 340 355 375 395 0 1 265 285 300 320 340 355 375 395 410 430 445 1 0 250 265 285 300 320 340 355 375 395 410 430 1 1 320 340 355 375 395 410 430 445 \ \ \ Pin C/F is pulled to high level. Unit: C For PT8A3361/2/3/4: Pin1:SEL2 Pin19:SEL1 Level1 Level2 Level3 Level4 Level5 Level6 Level7 Level8 Level9 Level10 Level11 0 0 100 110 120 130 140 150 160 170 180 190 200 0 1 130 140 150 160 170 180 190 200 210 220 230 1 0 120 130 140 150 160 170 180 190 200 210 220 1 1 160 170 180 190 200 210 220 230 \ \ \ 1 Input Button On/Off: This button will toggle Heating-on or Heating-off. 1). For PT8A3361; 3362; 3363; 3364; After power on, then push on/off button to heating-on, the level of temperature setting selected is as below: For PT8A3361/4 Pin1: SEL2 Pin19: SEL1 Pin C/F :low Pin C/F :High 0 0 150°C 300F 0 1 180°C 355F 1 0 170°C 340F 1 1 200°C 395F Push on/off button to heating-off without power-off then push on/off button to heating-on, the level of temperature setting selected is as former setting before heating-off. 2). Once heating-on, the level of temperature setting selected is as below: For PT8A3362/3 Pin1: SEL2 Pin19: SEL1 Pin C/F :low Pin C/F :High 0 0 150°C 300F 0 1 180°C 355F 1 0 170°C 340F 1 1 200°C 395F Up: Temperature up adjusts. Push Up button once, the temperature setting will increase one level until the highest level is reached. Down: Temperature down adjusts. Push Down button once, the temperature setting will reduce one level until the lowest level is reached. 12-07-0006 PT0356-1 6 07/06/12 PT8A3361/62/63/64 NTC+LCD Heating Controller |||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| 2 LCD Indicator Default described: The display on LCD indicates the temperature settings. During heating-up, LCD flashes, its frequency is 1.5Hz. When the temperature reaches 27°F -45°F (15°C -25°C) less than the level of temperature setting, LCD will turn always on. When adjust from low temperature setting level to high, LCD will flash twice. Its frequency is 1.5Hz. Class for LCD indicator Heating-UP level TEMP setting adjust TEMP Keep Heating-Down level 3 LCD Number LCD Signal bar Flash for 1.5Hz \ Up for flash twice Down to ON \ ON \ ON \ LCD Number LCD Signal bar LCD Number LCD Signal bar LCD Number LCD Signal bar Reset After power on, the chip will be reset by internal POR circuit, LCD is disabled. GATE and Backlight pins output low level. 4 LCD Backlight LCD backlight for heating-up or heating down and TEMP setting or TEMP keep, the show follow: P/N PT8A3361/2/3/4 BL1 Key on state PIN BL2 PIN \ BL3 PIN \ Note: Pin BL1 outputs high level under 100% hot up .key on state, and low level under power off state. Pin BL2 outputs high level under key on state keep 6s. Pin BL3 outputs high level under keep Temp. 5 Timer Once IC enters Heating-on state, internal timer will start to count. It’ll be timeout and auto heating-off about 1 hour both 60Hz and 50Hz. 6 Control signal output When working in Heating-on state, Gate output will be related to NTC1 input and CLK input amplitude. 1) Effect of NTC and VTCLK (Level 2) on GATE Working State CLK input voltage NTC (NTC open detection) High for level 2 (220V) ON V NTCO~ VDD Low for level 2 (110V) Off X* ON X 0~V NTCO NTC (Normal temp detection) Temperature lower than 100% settings Temperature between 90% to 100% settings Temperature is reached settings Temperature lower than 100% settings Temperature between 90% to 100% settings Temperature is reached settings X GATE (trigger to SCR/TRIAC) X 0 LCD 25% 12.5% 0 Normal 100% 50% 0 0 Display off ( flashes, its frequency is 3Hz) *Note: 1) X means any input. 12-07-0006 PT0356-1 7 07/06/12 PT8A3361/62/63/64 NTC+LCD Heating Controller |||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| Effect of NTC and Pulse Trigger on GATE 300s 300s 300s a. High trigger peak current (>20mA), enough trigger 20A triac b. Pulse triggering current to reduce the false self trigger by the leakage of triac at high temperature environment. c. Tal_GATE = 300s LCD Panel Specification Front Polarizer: Transmissive, Adhesive Polarizer Mode: Transflective/Positive Storage Temp : -10oC to +80oC Operating Temp : 0oC to +80oC Viewing Direction : 6 O’CLOCK Drive Condition : 1/4 Duty, 1/3 Bias, 5V Display Mode : TN, Positive Mode Vrms_on = 0.577VDD Vrms_off = 0.236VDD 12-07-0006 PT0356-1 8 07/06/12 PT8A3361/62/63/64 NTC+LCD Heating Controller |||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| 1) LCD signaling 2) Support 10 PIN 5V LCD 3) Support 12 PIN Pin 1 2 3 4 5 6 COM4 T 1D T1 2D T2 3D COM3 1E 1C 2E 2C 3E 3C COM2 1G 1B 2G 2B 3G 3B COM1 1F 1A 2F 2A 3F 3A 12-07-0006 7 8 9 10 COM4 5V LCD COM3 COM2 COM1 PT0356-1 9 07/06/12 PT8A3361/62/63/64 NTC+LCD Heating Controller |||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| Pin 1 2 3 4 5 6 7 COM4 K4 K1 1D K2 2D K3 3D COM3 K5 1E 1C 2E 2C 3E 3C T2 COM2 K6 1G 1B 2G 2B 3G 3B T1 COM1 K7 1F 1A 2F 2A 3F 3A T 12-07-0006 8 9 10 11 12 COM4 COM3 COM2 COM1 PT0356-1 10 07/06/12 PT8A3361/62/63/64 NTC+LCD Heating Controller |||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| Application Circuit PT8A3361/62/63/64 Application Circuit 12-07-0006 PT0356-1 11 07/06/12 PT8A3361/62/63/64 NTC+LCD Heating Controller |||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| Mechanical Information PE (Lead free and Green DIP-24) 12-07-0006 PT0356-1 12 07/06/12 PT8A3361/62/63/64 NTC+LCD Heating Controller |||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| SE (Lead free and Green SOIC-24) PKG. DIMENSIONS(MM) SYMBOL MIN MAX A 2.35 2.65 A1 0.10 0.30 A2 2.10 2.50 b 0.33 0.51 c 0.20 0.33 D 15.20 15.60 E 7.40 7.60 E1 10.21 10.61 e 1.27 BSC L 0.40 1.27 θ 0° 8° Note: 1) Controlling dimensions in millimeters. 2) Ref : JEDEC MS-013E/AD 12-07-0006 PT0356-1 13 07/06/12 PT8A3361/62/63/64 NTC+LCD Heating Controller |||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| LE (Lead free and Green TSSOP-24) PKG. DIMENSIONS(MM) SYMBOL MIN MAX A 1.100 A1 0.020 0.150 A2 0.800 1.000 b 0.190 0.300 c 0.090 0.200 D 7.700 7.900 E 4.300 4.500 E1 6.250 6.550 e 0.65 BSC L 0.500 0.700 θ 1° 7° Note: 1)) Ref : JEDEC MO-153F/AD 12-07-0006 PT0356-1 14 07/06/12 PT8A3361/62/63/64 NTC+LCD Heating Controller |||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| ZDE (Lead free and Green QFN-24) 12-07-0006 PT0356-1 15 07/06/12 PT8A3361/62/63/64 NTC+LCD Heating Controller |||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| Ordering Information Part No. Package Code Package PT8A336xPE P Lead free DIP-24 PT8A336xSE S Lead free and Green SOIC-24 PT8A336xZDE D Lead free and Green QFN-24 PT8A336xLE L Lead free and Green TSSOP-24 Note:  “X” shows 1-4, see below function comparison table.  E = Pb-free and Green  Adding X Suffix= Tape/Reel  Contact Pericom for availability. Function Comparison Table P/N Timer(1H) Keep TEMP Setting PT8A3361 Y Y PT8A3362 Y N PT8A3363 N N PT8A3364 N Y TEMP Step TEMP(℃) 11 11 11 8 11 11 11 8 11 11 11 8 11 11 11 8 100-200 130-230 120-220 160-230 100-200 130-230 120-220 160-230 100-200 130-230 120-220 160-230 100-200 130-230 120-220 160-230 LCD Backlight LCD Pin ℃/F Change for UP/DOWN Key 1 10 N 1 10 N 1 10 N 1 10 N Note: Keep TEMP Setting: Push on/off button to heating-off without power-off then push on/off button to heating-on, the level of temperature setting selected is as former setting before heating-off. Pericom Semiconductor Corporation  1-800-435-2336  www.pericom.com Pericom reserves the right to make changes to its products or specifications at any time, without notice, in order to improve design or performance and to supply the best possible product. Pericom does not assume any responsibility for use of any circuitry described other than the circuitry embodied in Pericom product. The company makes no representations that circuitry described herein is free from patent infringement or other rights, of Pericom. 12-07-0006 PT0356-1 16 07/06/12
PT8A3362SE 价格&库存

很抱歉,暂时无法提供与“PT8A3362SE”相匹配的价格&库存,您可以联系我们找货

免费人工找货