PT8A3361/62/63/64
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
NTC+LCD Heating Controller
Features
Description
LCD screen showing temperature setting
The PT8A336x is a mixed signal CMOS LSI chip
Dual Temperature (Fahrenheit/Centigrade) Display
designed as heating controller with help of external NTC
Backlights indicating work status
(Negative
Auto temperature control with NTC
protection is implemented for device safety and 11
8 and 11 temperature levels option
Three keys: On/Off, Up and Down
NTC open protection
Pulse trigger for high current SCR/TRIAC (up to
15mA)
Temperature
Component).
NTC
open
temperature levels. It can drive TRIAC or SCR directly.
It has 3 keys function setting. LCD displays and
backlight indicate the working status.
This device can be used in both 120V and 240V power
1 hour auto power off.
line supplier, as it will automatically adjust the heating
Dual Voltage (120V/240V) operations
power according to the power line voltage to avoid
Internal 5V zener
heating appliance damage or long heating time.
Lead free and Green QFN-24, TSSOP-24 and
The PT8A336x build-in timer will be auto-power off
SOIC-24 package; Lead free DIP-24 package
after power on 1 hour both 60Hz and 50Hz.
Applications
Heating Controller
Block Diagram
12-07-0006
PT0356-1
1
07/06/12
PT8A3361/62/63/64
NTC+LCD Heating Controller
||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pin Information
Pin Configuration
PT8A3361/62/63/64
Pin Description
Pin No.
Name
Type
Description
1, 19
SEL2,SEL1
I
Select temperature setting: 00: 100C~200C; 01: 130C~230C;10:
120C~220C; 11: 160C~230C.
O
LCD digits control output.
O
LCD digits control output.
O
Internal pull up, default for LCD shows C; Low level: LCD shows F.
7
SEG1,SEG2,
SEG3,SEG4,
SEG5,SEG6,
COM1,COM2
COM3,COM4
C/F
8
NTC1
I
NTC voltage input, NTC open detection input.
9
NTC2
O
Output signal for NTC open detection.
10
GND
Power
11
CLK
I
Clock input from power line.
12
K2
I
Power on/off key inputs.
13
K1
I
Up and down key inputs.
14
VDD
Power
15
GATE
O
TRIAC and SCR trigger output.
16
BL1
O
Drive LCD backlight.
17, 18
NC
-
No connection.
20, 21, 22,
24, 23, 2
3,4,5,6
Ground.
Power.
12-07-0006
PT0356-1
2
07/06/12
PT8A3361/62/63/64
NTC+LCD Heating Controller
||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Maximum Ratings
Storage Temperature ................................................................................... -55oC to +150oC
Supply Voltage to Ground Potential (Input & VDD Only)........................-0.5V to +6.5V
Supply Voltage to Ground Potential (Output s Only) ...............................-0.5V to +6.5V
DC Input Voltage .............................................................................................-0.5V to +6.5V
Input/Output Current ................................................................... 50mA
Input/Output Current (Pin VDD only) ...................................... 200mA
Power Dissipation ......................................................................................................... 500mW
Note:
Stresses greater than those listed under MAXIMUM
RATINGS may cause permanent damage to the
device. This is a stress rating only and functional
operation of the device at these or any other
conditions above those indicated in the operational
sections of this specification is not implied.
Exposure to absolute maximum rating conditions
for extended periods may affect reliability.
Recommended operation conditions
Sym
Parameter
Min
Typ
Max
Unit
VDD
TA
Operating Voltage
Operating temperature
4.0
-20
-
VZ
85
V
°C
Electrical Characteristics (VDD = 4.0~Vz, TA = -20 ~ 85ºC, unless otherwise noted)
DC Input Characteristics
Symbol
VNTCADC
Description
Voltage of
ADC
Test Conditions
Step
Step 0
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
Step 10
Step 11
Step 12
Step 13
Step 14
Pin:NTC1
Step 15
VDD=4.5V
Step 16
Step 17
Step 18
Step 19
Step 20
Step 21
Step 22
Step 23
Step 24
Step 25
Step 26
Step 27
Step 28
Step 29
Step 30
Step 31
Temp(ºC)
25
50
75
90
100
105
110
115
120
125
130
135
140
145
150
155
160
165
170
175
180
185
190
195
200
205
210
215
220
225
230
234
Min
Type
Max
Unit
0.08
0.2375
0.575
0.8675
1.089
1.2163
1.33
1.45
1.5875
1.70
1.81
1.93
2.05
2.17
2.25
2.3525
2.43
2.52
2.60
2.645
2.72
2.79
2.8450
2.89
2.94
2.98
3.0133
3.0472
3.08
3.116
3.138
3.16
0.09
0.2475
0.585
0.8775
1.099
1.2263
1.34
1.46
1.5975
1.71
1.82
1.94
2.06
2.16
2.26
2.35
2.44
2.53
2.61
2.655
2.73
2.80
2.8550
2.9
2.95
2.99
3.0233
3.0572
3.09
3.126
3.148
3.17
0.1
0.2575
0.595
0.8875
1.109
1.2363
1.35
1.47
1.6075
1.72
1.83
1.95
2.07
2.17
2.27
2.3725
2.45
2.54
2.62
2.665
2.74
2.81
2.8650
2.91
2.96
3.0
3.0333
3.0672
3.1
3.136
3.158
3.18
V
To be continued
12-07-0006
PT0356-1
3
07/06/12
PT8A3361/62/63/64
NTC+LCD Heating Controller
||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Continued
Symbol
Description
IIH
IIL
Input high
current
Input low
current
Test Conditions
VIN = VDD, VCLK=GND
Pin:K1
VIN = VDD, VCLK=VDD
Pin: C/F,
SEL2,
VIN = VDD
SEL1
Pin: K2
VIN = VDD
Pin: CLK VIN = VDD
Pin:NTC1 VIN = VDD
VIN =VDD ,Output High
Pin:NTC2
impedance
VIN = GND, VCLK =-1V
Pin:K1
VIN = GND, VCLK =1V
Pin: C/F
VIN = GND
Pin:K2
SEL1,
VIN = GND
SEL2
VIN = GND
Pin: CLK
VIN =-0.35V
Pin:NTC1 VIN = GND
VIN = GND, Output High
Pin:NTC2
impedance
Min
-
Type
-
Max
60
5
Unit
-
-
5
A
-
-
80
1
100
A
A
nA
-
-
100
nA
-
-
-5
-60
-50
A
-
-
-5
A
-
-
-5
-10
-100
A
A
nA
-10
-
-100
nA
A
A
DC Output Electrical Characteristics
Symbol
IOH
Description
Test Conditions
Pin: GATE
Output High
Current
Pin: BL1, BL2, BL3
Pin: GATE
IOL
VLCD
Output Low
Current
Output High
Voltage
Pin: BL
Pin:COM1,COM2, COM3, COM4,
SEG1, SEG2, SEG3, SEG4,
SEG,5,SEG6,
VDD = 4.5V
VOUT = 2.5V
VDD =4.5V
VOUT =4.0V
VDD = 4.5V
VOUT =0.5V
VDD =4.5V
VOUT =0.5V
Level3
Level2
VDD =
4.5V
Level1
Min
Type
Max
-15
-
-
-3.0
-
-
4.0
-
-
4.0
-
-
0.54VDD
0.6VDD
0.66VDD
0.36VDD
0.4VDD
0.44VDD
0.18VDD
0.2VDD
0.22VDD
Unit
mA
mA
Power Supply Characteristics
Symbol
VPOR
IDD
VDD
VZ
TPOoff
Description
Voltage of POR
Current consumption
Supply voltage
Voltage of Zener
Power off timer
Test Conditions
No loading, V DD =4.5V
Control function normal
IDD=1mA ~20mA
FCLK= 50Hz/60Hz
12-07-0006
Min
2
4.0
4.5
55
Type
5.0
60
Max
3
800
VZ
5.5
65
PT0356-1
4
Unit
V
A
V
V
Minute
07/06/12
PT8A3361/62/63/64
NTC+LCD Heating Controller
||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Line Clock Synchronization Characteristics
Symbol
Description
VT_CLK
Input Threshold
Voltage of CLK Pin
FCLK
Frequency of CLK
Test Conditions
Level2
VTL_Level1
VDD =4.5V
VT_Level2 is high
VTH_Level1
VTL_Level1
VDD =4.5V
VT_Level2 is low
VTH_Level1
VTL_Level2
VDD =4.5V
VT_Level2 is high
VTL_Level2
VTL_Level2
VDD =4.5V
VT_Level2 is high
VTL_Level2
-
Min
1.7
-200
-100
-125
-40
105
210
70
145
-
Type
1.88
-250
-150
-175
-90
145
250
90
185
50/60
Max
2.1
-300
-200
-225
-140
185
290
110
225
-
Unit
V
Test Conditions
TA=25 ºC, VDD = 4.5V
VDD = 4.0 ~ Vz
TA = -20 ~ 85ºC
Min
291
Type
300
Max
309
Unit
s
285
-
315
s
mV
Hz
GATE Pulse Characteristics
Symbol
Tal_Gate
Description
Width of Gate trigger
pulse
12-07-0006
PT0356-1
5
07/06/12
PT8A3361/62/63/64
NTC+LCD Heating Controller
||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Function Description
The PT8A336x is a mixed signal CMOS LSI chip designed as heating controller with help of external NTC (Negative
Temperature Component). NTC open protection is implemented for device safety and 11 temperature levels 100℃, 110℃, 120℃,
130℃, 140℃, 150℃, 160℃, 170℃, 180℃, 190℃, 200℃. It can drive TRIAC or SCR directly. It has 3 keys function setting.
LCD displays and backlight indicate the working status.
This device can be used in both 120V and 240V power line supplier, as it will automatically adjust the heating power according
to the power line voltage to avoid heating appliance damage or long heating time.
The PT8A3361/2/3/4 build-in timer will be auto-power off after power on 1 hour both 60Hz and 50Hz.
Temperature setting is as below:
Pin C/F is pulled to low level. Unit: F
For PT8A3361/2/3/4:
Pin1:SEL2 Pin19:SEL1 Level1 Level2 Level3 Level4 Level5 Level6 Level7 Level8 Level9 Level10 Level11
0
0
210
230
250
265
285
300
320
340
355
375
395
0
1
265
285
300
320
340
355
375
395
410
430
445
1
0
250
265
285
300
320
340
355
375
395
410
430
1
1
320
340
355
375
395
410
430
445
\
\
\
Pin C/F is pulled to high level. Unit: C
For PT8A3361/2/3/4:
Pin1:SEL2 Pin19:SEL1 Level1 Level2
Level3
Level4
Level5
Level6
Level7
Level8
Level9
Level10
Level11
0
0
100
110
120
130
140
150
160
170
180
190
200
0
1
130
140
150
160
170
180
190
200
210
220
230
1
0
120
130
140
150
160
170
180
190
200
210
220
1
1
160
170
180
190
200
210
220
230
\
\
\
1 Input Button
On/Off: This button will toggle Heating-on or Heating-off.
1). For PT8A3361; 3362; 3363; 3364;
After power on, then push on/off button to heating-on, the level of temperature setting selected is as below:
For PT8A3361/4
Pin1: SEL2
Pin19: SEL1 Pin C/F :low Pin C/F :High
0
0
150°C
300F
0
1
180°C
355F
1
0
170°C
340F
1
1
200°C
395F
Push on/off button to heating-off without power-off then push on/off button to heating-on, the level of temperature
setting selected is as former setting before heating-off.
2). Once heating-on, the level of temperature setting selected is as below:
For PT8A3362/3
Pin1: SEL2 Pin19: SEL1 Pin C/F :low Pin C/F :High
0
0
150°C
300F
0
1
180°C
355F
1
0
170°C
340F
1
1
200°C
395F
Up: Temperature up adjusts. Push Up button once, the temperature setting will increase one level until the highest level is
reached.
Down: Temperature down adjusts. Push Down button once, the temperature setting will reduce one level until the lowest
level is reached.
12-07-0006
PT0356-1
6
07/06/12
PT8A3361/62/63/64
NTC+LCD Heating Controller
||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2 LCD Indicator
Default described:
The display on LCD indicates the temperature settings.
During heating-up, LCD flashes, its frequency is 1.5Hz. When the temperature reaches 27°F -45°F (15°C -25°C) less than the
level of temperature setting, LCD will turn always on.
When adjust from low temperature setting level to high, LCD will flash twice. Its frequency is 1.5Hz.
Class for LCD indicator
Heating-UP level
TEMP setting adjust
TEMP Keep
Heating-Down level
3
LCD Number
LCD Signal bar
Flash for 1.5Hz
\
Up for flash twice
Down to ON
\
ON
\
ON
\
LCD Number
LCD Signal bar
LCD Number
LCD Signal bar
LCD Number
LCD Signal bar
Reset
After power on, the chip will be reset by internal POR circuit, LCD is disabled. GATE and Backlight pins output low level.
4 LCD Backlight
LCD backlight for heating-up or heating down and TEMP setting or TEMP keep, the show follow:
P/N
PT8A3361/2/3/4
BL1
Key on state
PIN
BL2 PIN
\
BL3 PIN
\
Note: Pin BL1 outputs high level under 100% hot up .key on state, and low level under power off state.
Pin BL2 outputs high level under key on state keep 6s.
Pin BL3 outputs high level under keep Temp.
5 Timer
Once IC enters Heating-on state, internal timer will start to count. It’ll be timeout and auto heating-off about 1 hour both
60Hz and 50Hz.
6 Control signal output
When working in Heating-on state, Gate output will be related to NTC1 input and CLK input amplitude.
1) Effect of NTC and VTCLK (Level 2) on GATE
Working
State
CLK input
voltage
NTC (NTC
open detection)
High for level
2 (220V)
ON
V NTCO~ VDD
Low for level
2 (110V)
Off
X*
ON
X
0~V NTCO
NTC
(Normal temp detection)
Temperature lower than
100% settings
Temperature between 90%
to 100% settings
Temperature is reached
settings
Temperature lower than
100% settings
Temperature between 90%
to 100% settings
Temperature is reached
settings
X
GATE (trigger to
SCR/TRIAC)
X
0
LCD
25%
12.5%
0
Normal
100%
50%
0
0
Display off
( flashes, its
frequency is 3Hz)
*Note: 1) X means any input.
12-07-0006
PT0356-1
7
07/06/12
PT8A3361/62/63/64
NTC+LCD Heating Controller
||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Effect of NTC and Pulse Trigger on GATE
300s
300s
300s
a. High trigger peak current (>20mA), enough trigger 20A triac
b. Pulse triggering current to reduce the false self trigger by the leakage of triac at high temperature environment.
c. Tal_GATE = 300s
LCD Panel Specification
Front Polarizer: Transmissive, Adhesive
Polarizer Mode: Transflective/Positive
Storage Temp : -10oC to +80oC
Operating Temp : 0oC to +80oC
Viewing Direction : 6 O’CLOCK
Drive Condition : 1/4 Duty, 1/3 Bias, 5V
Display Mode : TN, Positive Mode
Vrms_on = 0.577VDD
Vrms_off = 0.236VDD
12-07-0006
PT0356-1
8
07/06/12
PT8A3361/62/63/64
NTC+LCD Heating Controller
||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1) LCD signaling
2) Support 10 PIN 5V LCD
3) Support 12 PIN
Pin
1
2
3
4
5
6
COM4
T
1D
T1
2D
T2
3D
COM3
1E
1C
2E
2C
3E
3C
COM2
1G
1B
2G
2B
3G
3B
COM1
1F
1A
2F
2A
3F
3A
12-07-0006
7
8
9
10
COM4
5V LCD
COM3
COM2
COM1
PT0356-1
9
07/06/12
PT8A3361/62/63/64
NTC+LCD Heating Controller
||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pin
1
2
3
4
5
6
7
COM4
K4
K1
1D
K2
2D
K3
3D
COM3
K5
1E
1C
2E
2C
3E
3C
T2
COM2
K6
1G
1B
2G
2B
3G
3B
T1
COM1
K7
1F
1A
2F
2A
3F
3A
T
12-07-0006
8
9
10
11
12
COM4
COM3
COM2
COM1
PT0356-1
10
07/06/12
PT8A3361/62/63/64
NTC+LCD Heating Controller
||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Application Circuit
PT8A3361/62/63/64 Application Circuit
12-07-0006
PT0356-1
11
07/06/12
PT8A3361/62/63/64
NTC+LCD Heating Controller
||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Mechanical Information
PE (Lead free and Green DIP-24)
12-07-0006
PT0356-1
12
07/06/12
PT8A3361/62/63/64
NTC+LCD Heating Controller
||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SE (Lead free and Green SOIC-24)
PKG. DIMENSIONS(MM)
SYMBOL
MIN
MAX
A
2.35
2.65
A1
0.10
0.30
A2
2.10
2.50
b
0.33
0.51
c
0.20
0.33
D
15.20
15.60
E
7.40
7.60
E1
10.21
10.61
e
1.27 BSC
L
0.40
1.27
θ
0°
8°
Note:
1) Controlling dimensions in millimeters.
2) Ref : JEDEC MS-013E/AD
12-07-0006
PT0356-1
13
07/06/12
PT8A3361/62/63/64
NTC+LCD Heating Controller
||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
LE (Lead free and Green TSSOP-24)
PKG. DIMENSIONS(MM)
SYMBOL
MIN
MAX
A
1.100
A1
0.020
0.150
A2
0.800
1.000
b
0.190
0.300
c
0.090
0.200
D
7.700
7.900
E
4.300
4.500
E1
6.250
6.550
e
0.65 BSC
L
0.500
0.700
θ
1°
7°
Note:
1)) Ref : JEDEC MO-153F/AD
12-07-0006
PT0356-1
14
07/06/12
PT8A3361/62/63/64
NTC+LCD Heating Controller
||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
ZDE (Lead free and Green QFN-24)
12-07-0006
PT0356-1
15
07/06/12
PT8A3361/62/63/64
NTC+LCD Heating Controller
||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ordering Information
Part No.
Package Code
Package
PT8A336xPE
P
Lead free DIP-24
PT8A336xSE
S
Lead free and Green SOIC-24
PT8A336xZDE
D
Lead free and Green QFN-24
PT8A336xLE
L
Lead free and Green TSSOP-24
Note:
“X” shows 1-4, see below function comparison table.
E = Pb-free and Green
Adding X Suffix= Tape/Reel
Contact Pericom for availability.
Function Comparison Table
P/N
Timer(1H)
Keep TEMP
Setting
PT8A3361
Y
Y
PT8A3362
Y
N
PT8A3363
N
N
PT8A3364
N
Y
TEMP Step
TEMP(℃)
11
11
11
8
11
11
11
8
11
11
11
8
11
11
11
8
100-200
130-230
120-220
160-230
100-200
130-230
120-220
160-230
100-200
130-230
120-220
160-230
100-200
130-230
120-220
160-230
LCD
Backlight
LCD Pin
℃/F Change for
UP/DOWN Key
1
10
N
1
10
N
1
10
N
1
10
N
Note:
Keep TEMP Setting: Push on/off button to heating-off without power-off then push on/off button to heating-on, the level of
temperature setting selected is as former setting before heating-off.
Pericom Semiconductor Corporation 1-800-435-2336 www.pericom.com
Pericom reserves the right to make changes to its products or specifications at any time, without notice, in order to improve design or performance and to supply
the best possible product. Pericom does not assume any responsibility for use of any circuitry described other than the circuitry embodied in Pericom product. The
company makes no representations that circuitry described herein is free from patent infringement or other rights, of Pericom.
12-07-0006
PT0356-1
16
07/06/12