0RCR-30S12X 数据手册
ISOLATED DC/DC CONVERTERS 48 VDC Input 11.8 VDC/25 A Output, 1/8 Brick 0RCR-30S12x • • • • • Isolated Fixed Frequency High Efficiency High Power Density Low Cost RoHS Compliant • • • • • Rev.E Input Under-Voltage Lockout Input Over-Voltage Shutdown OCP/SCP Over Temperature Protection Remote On/Off Description The 0RCR-30S12x are isolated DC/DC converters that operate from a nominal 48 VDC source. These converters use a full bridge power train to provide isolation and step down. These units will provide up to 300 W of output power from a nominal 48 VDC input. These units are designed to be highly efficient and low cost. Features include remote on/off, over current protection and under voltage lockout. These converters are provided in an industry standard eighth-brick package. Part Selection Output Voltage 11.8 V Input Voltage 48 V Max. Output Current 25 A Max. Output Power 300 W Typical Efficiency 96% Model Number Active Low 0RCR-3012L Model Number Active High 0RCR-30S120 Notes: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging. 2. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers. Absolute Maximum Ratings Parameter Input Voltage (continuous) Remote On/Off (Active Low) Remote On/Off (Active High) Ambient Temperature Storage Temperature Min -0.3 V -0.3 V 2V 0V 2V 0V -40 °C -55 °C Typ Max 80 V 57 V 20 V 0.4 V 20 V 0.4 V 85 °C 125 °C Notes Non-operating Operating Module Off Module On Module On Module Off Input Specifications Parameter Input Voltage Input Current (full load) Input Current (no load) Remote Off Input Current Input Reflected Ripple Current (pk-pk) Input Reflected Ripple Current (rms) I2t Inrush Current Transient Min 38 V Typ 90 mA 8 mA 25 mA 5 mA TBD Max 55 V 8.5 A 150 mA 15 mA 50 mA 10 mA Tested with simulated source impedance of 12 uH, 5 Hz to 20 MHz; use a 100 uF/100 V electrolytic capacitor and 1 uF/100 V ceramic capacitor at the input. Vin=38 V Notes Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 48 VDC Input 11.8 VDC/25 A Output, 1/8 Brick Input Specifications (continued) Parameter Input Over-Voltage Protection Threshold Turn On Voltage Threshold Turn Off Voltage Threshold Min 58 V 57 V 33 V 32 V Typ 60 V 59 V 35 V 33.5 V Max 62 V 61 V 36.5 V 35 V Notes Turn-Off Voltage Threshold Turn-On Voltage Threshold Note: All specifications are typical at 25 °C unless otherwise stated. Output Specifications Parameter Output Voltage Set Point Vin=38 V Vin=48 V Vin=55 V Load Regulation Output Current Operating Output Power Range Current Limit Threshold Short Circuit Surge Transient Ripple and Noise (rms) Ripple and Noise (pk-pk) Turn on Time Overshoot at Turn on Output Capacitance Transient Response 50% ~ 75% Max Load 75% ~ 50% Max Load Overshoot Settling Time Overshoot Settling Time Vin=48 V 200 mV 100 uS 200 mV 100 uS Test conditions: di/dt = 0.1 A/uS, Vin=48 V, with a 1 uF ceramic cap and a 47 uF tantalum cap at the output. Min 0A 0W 110%Po 0 uF Typ 9.4 V 11.8 V 13.5 V 400 mV TBD 15 mV 50 mV 15 mS Max 600 mV 25 A 300 W 165%Po 50 mV 120 mV 20 mS 5% 3300 uF Test conditions: 0-20 MHz BW, with a 1 uF ceramic cap and a 47 uF tantalum cap at the output. lo=no load Notes Vin=48 V Note: All specifications are typical at 25 °C unless otherwise stated. Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 48 VDC Input 11.8 VDC/25 A Output, 1/8 Brick General Specifications Parameter Efficiency Switching Frequency Isolation Capacitance Isolation Voltage Over Temperature Protection MTBF Dimensions Inches (L × W × H) Millimeters (L × W × H) Weight 2.30 x 0.896 x 0.50 58.41 x 22.76 x 12.7 42 g Min 95% Typ 96% 250 kHz 3900 pF 1500 V 125 °C TBD Max Calculated Per Bell Core SR-332 (Vin=48 V; IO=80% full load; Ta = 25 °C) Notes Vin=48 V, full load, 25°C - Note: All specifications are typical at 25 °C unless otherwise stated. Control Specifications Parameter Remote On/Off Signal High (Unit Off) Signal Low (Unit On) Signal High (Unit On) Active High Signal Low (Unit Off) 0V 0.4 V Active Low 2V 0V 2V 20 V 0.4 V 20 V The remote on/off pin is open: If active low, the Unit Off; If active high, the Unit On. Min Typ Max Notes Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 48 VDC Input 11.8 VDC/25 A Output, 1/8 Brick Efficiency Data 99.0% 98.0% 97.0% Efficiency 96.0% 95.0% 94.0% 93.0% 92.0% 91.0% 90.0% 3.2 6.4 9.6 12.8 16 19.2 22.4 25.6 28.8 32 38 V 48 V 55V Output current Thermal Derating Curve This derating curve is tested when Vin=48 Vdc Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 48 VDC Input 11.8 VDC/25 A Output, 1/8 Brick Ripple and Noise Waveforms 38 Vdc input 48Vdc input 55 Vdc input Note: Ripple and noise at full load, with 1 uF ceramic cap and 47 uF Tan cap at the output, and Ta=25 deg C. Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 48 VDC Input 11.8 VDC/25 A Output, 1/8 Brick Transient Response Waveforms 50% to 75% load Transient at 38 Vdc input 75% to 50% load Transient at 38 Vdc input 50% to 75% load Transient at 48 Vdc input 75% to 50% load Transient at 48 Vdc input 50% to 75% load Transient at 55 Vdc input 75% to 50% load Transient at 55 Vdc input Note: Transient response at di/dt=0.1 A/uS, with 1 uF ceramic cap and 47 uF Tan cap at the output, and Ta=25 deg C. Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 48 VDC Input 11.8 VDC/25 A Output, 1/8 Brick Mechanical Outline Pin Connections Pin 1 2 3 4 5 Function Vin+ On/Off VinVoutVout+ Pin Size 0.040’’ 0.040’’ 0.040’’ 0.062’’ 0.062’’ RoHS Compliance Complies with the European Directive 2002/95/EC, calling for the elimination of lead and other hazardous substances from electronic products. ©2008 Bel Fuse Inc. Specifications subject to change without notice. 121808 CORPORATE Bel Fuse Inc. 206 Van Vorst Street Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com FAR EAST Bel Fuse Ltd. 8F/ 8 Luk Hop Street San Po Kong Kowloon, Hong Kong Tel 852-2328-5515 Fax 852-2352-3706 www.belfuse.com EUROPE Bel Fuse Europe Ltd. Preston Technology Management Centre Marsh Lane, Suite G7, Preston Lancashire, PR1 8UD, U.K. Tel 44-1772-556601 Fax 44-1772-888366 www.belfuse.com
0RCR-30S12X
1. 物料型号: - 型号包括0RCR-30S12x系列,不同型号对应的输出电压和电流有所不同。例如,0RR 30提供30W功率和25A电流。

2. 器件简介: - 0RCR-30S12x是隔离式DC/DC转换器,工作电压为48VDC,使用全桥功率列车提供隔离和降压功能,输出功率高达300W,设计高效且低成本,具备远程开关、过流保护和欠压锁定等功能,并采用行业标准的八分之一砖封装。

3. 引脚分配: - Pin 1: Vin+(输入正) - Pin 2: On/Off(远程开关控制) - Pin 3: Vin-(输入负) - Pin 4: Vout-(输出负) - Pin 5: Vout+(输出正)

4. 参数特性: - 输入电压范围:38V至55V - 输出电压设定点:在不同输入电压下的输出电压分别为9.4V、11.8V和13.5V - 效率:95%至96% - 开关频率:250kHz - 隔离电容:3900pF - 隔离电压:1500V

5. 功能详解: - 这些转换器具备输入欠压锁定、输入过压关闭、过流保护/短路保护、高温保护、远程开关等功能。

6. 应用信息: - 适用于需要隔离和降压的DC/DC转换的应用场合,特别是在工业和通信领域。

7. 封装信息: - 采用1/8砖封装,尺寸为2.30英寸x0.896英寸x0.50英寸(58.41mm x 22.76mm x 12.7mm),重量约为42克。