ISOLATED DC/DC CONVERTERS
48 Vdc Input 3.3 Vdc /30 A Output
0RCY-C2T03x
• • • • • • •
RoHS Compliant
• • • • • •
Rev.B
Isolated High Efficiency High Power Density Fixed Frequency (300 kHz) Low Cost Input Under-Voltage Lockout Output Over-Voltage Protection
Output Voltage Trim OCP/SCP Over Temperature Protection Remote On/Off Positive/Negative Remote Sense Basic Insulation
Description
The 0RCY-C2T03x is isolated dc/dc converter that operates from a nominal 48 Vdc source. This unit will provide up to 99 W of output power from a nominal 48 Vdc input. This unit is designed to be highly efficient and low cost. Features include remote on/off, over current protection and under-voltage lockout. This converter is provided in an industry standard eighth brick package.
Part Selection
Output Voltage 3.3 Vdc Input Voltage 48 Vdc Max. Output Current 30 A Max. Output Power 99 W Typical Efficiency 93% Model Number Active High 0RCY-C2T030 Model Number Active Low 0RCY-C2T03L
Notes: 1. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers. 2. Add “G” suffix at the end of the model number to indicate Tray Packaging.
Absolute Maximum Ratings
Parameter Input Voltage (continuous) Remote On/Off I/O Isolation Voltage Ambient Temperature Storage Temperature Min -0.3 V -0.3 V 1500 V -40 °C -55 °C Typ Max 80 V 18 V 85 °C 125 °C Notes
Input Specifications
Parameter Input Voltage Input Current (full load) Input Current (no load) Remote Off Input Current Input Reflected Ripple Current (rms) Input Reflected Ripple Current (pkpk) I t Inrush Current Transient Turn-on Voltage Threshold Turn-off Voltage Threshold
2
Min 36 V 33 V 32 V
Typ 48 V 70 mA 10 mA 5 mA -
Max 75 V 4.5 A 120 mA 15 mA 10 mA 30 mA 0.1 A s 35.5 V 34.5 V
2
Notes
With simulated source impedance of 10 uH, 5Hz to 20MHz. Use a 100 uF/100 V electrolytic cap with ESR=1 ohm max, at 200 KHz@25°C.
Note: All specifications are typical at 25 °C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 3.3 Vdc /30 A Output
Min 3.234 V 0A 33 A 470 uF Typ 3.30 V ±4 mV ±8 mV ±30 mV 10 mV 55 mV 2 2A s 0% Max 3.366 V ±9 mV ±16.5 mV ±50 mV 20 mV 90 mV 30 A 44 A 2 4A s 25 mS 5600 uF 50 mV 150 uS 50 mV 150 uS 100 mV 250 uS 100 mV 250 uS di/dt=0.1 A/us, Vin=48 Vdc, with a 1µF ceramic capacitor and the minimum external Tantalum cap at output. 0-20MHz BW, with a 1µF ceramic capacitor and the minimum external Tantalum cap at output. Notes Vin=48 V, Io=50%load
Output Specifications
Parameter Output Voltage Set Point Load Regulation line Regulation Regulation Over Temperature (-40deg.C-85deg.C) Ripple and Noise (rms) Ripple and Noise (pk-pk) Output Current Range Output DC Current Limit Short Circuit Surge Transient Turn on Time Overshoot at Turn on Output Capacitance Transient Response Overshoot 25% ~ 50% Max Load Settling Time Overshoot 50% ~ 25% Max Load Settling Time
VO=3.3 V
Note: All specifications are typical at 25 °C unless otherwise stated.
General Specifications
Parameter Efficiency Switching Frequency Isolation capacitance Output Voltage Trim Range Remote Sense Compensation Over Temperature Protection Over Voltage Protection MTBF Dimensions Inches (L × W × H) Millimeters (L × W × H) Weight 2.30 x 0.90 x 0.37 58.42 x 22.78 x 9.50 28 g Min 90% 270 kHz 90% 3.8 V Typ 93% 300 kHz 2200 pF 125 °C TBD Max 330 kHz 110% 10% 4.5 V Notes Measured at Vin=48 V, full load.
Vin=48V, full load and short feedback optocoupler. Vin=48 V, full load, in hiccup Mode Calculated Per Bell Core SR-332 (Io=80%load, Ta = 25 °C)
Note: All specifications are typical at 25 °C unless otherwise stated.
Control Specifications
Parameter Remote On/Off Signal Low (Unit On) Signal High (Unit Off) Signal Low (Unit Off) Signal High (Unit On) Current Sink Active Low Active High Min -0.7 V 2.4 V -0.7 V 2.4 V 0 mA Typ Max 0.8 V 18 V 0.8 V 18 V 1 mA Notes When Remote On/Off pin is open, unit is off. When Remote On/Off pin is open, unit is on.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 3.3 Vdc /30 A Output
Output Trim Equations
Equations for calculating the trim resistor are shown below. The Trim Down resistor should be connected between the Trim pin and GND pin. The Trim Up resistor should be connected between the Trim pin and the Vout pin. Only one of the resistors should be used for any given application.
511 Rtrimdown = − 10.22[kΩ] delta
Vout Module Trim GND Rtrimdown
Rtrimup =
(100 + delta) ⋅ Vo ⋅ 5.11 − 626 − 10.22[kΩ ] 1 .225 ⋅ delta
Module
Vout Trim GND Rtrimup
Note:
delta =
(Vo _ req − Vo ) × 100 [% ]
Vo
Vo_req=Desired (trimmed) output voltage [V] Output voltage Vo=3.3 V
Efficiency Data
Efficiency Curve 94% 92% 90% 88% 86% 84% 82% 80% 78% 76% 74% 72% 70% 3.00
Efficiency
36 V 48 V 75 V
7.50
15.00
22.50
30.00
Output Current (A)
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 3.3 Vdc /30 A Output
Thermal Derating Curve
Vin=48V, with maximum junction temperature of semiconductors derated to 120 degree C
Ripple and Noise Waveforms
Io=0A Vin=48V
Io=30A Vin=48V
Note: Ripple and noise with a 1uF ceramic cap and a 10 uF Tantalum cap at output, and Ta=25 deg C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 3.3 Vdc /30 A Output
Transient Response Waveforms
Vout=3.3V 75% to 50% Load Transients at Vin=48V
Vout=3.3V 50% to 75% Load Transients at Vin=48V
Note: Transient Response at di/dt=0.1A/uS, External 330uF Tantalum Cap, Ta=25deg C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 3.3 Vdc /30 A Output
Mechanical Outline
Pin Connections
Pin 1 2 3 4 5 6 7 8 Name Vin+ On/Off VinVoutSenseTrim Sense+ Vout+ Pin Dia 0.040’’ 0.040’’ 0.040’’ 0.060’’ 0.040’’ 0.040’’ 0.040’’ 0.060’’
RoHS Compliance
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and other hazardous substances from electronic products.
©2010 Bel Fuse Inc. Specifications subject to change without notice. 011310
CORPORATE Bel Fuse Inc. 206 Van Vorst Street Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com
FAR EAST Bel Fuse Ltd. 8F/ 8 Luk Hop Street San Po Kong Kowloon, Hong Kong Tel 852-2328-5515 Fax 852-2352-3706 www.belfuse.com
EUROPE Bel Fuse Europe Ltd. Preston Technology Management Centre Marsh Lane, Suite G7, Preston Lancashire, PR1 8UD, U.K. Tel 44-1772-556601 Fax 44-1772-888366 www.belfuse.com
很抱歉,暂时无法提供与“0RCY-C2T030”相匹配的价格&库存,您可以联系我们找货
免费人工找货