ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input +12 Vdc/5 A, -12 Vdc/1.5 A Dual Outputs 0RXU-75TD10 • • • • • • Isolated Fixed Frequency (300 kHz) High Efficiency High Power Density RoHS Compliant • • • • • • Low Cost SCP/OCP Remote On/Off Rev.A Output Voltage Trim Output Over-Voltage Protection (OVP) Over Temperature Protection Input Under- Voltage Lockout (UVLO) UL60950-1 Recognized (UL/cUL) and CE Mark Description The 0RXU-75TD10 is an isolated dc/dc converter that operates from a nominal 48 Vdc source. It provides up to 78 W of output power with two output voltages. Features include remote on/off, output adjust, short circuit protection, over current protection, over-temperature shutdown, output over voltage protection, and input under voltage lockout. This converter is provided in a compact, though-hole package that is easy to use and provides good thermal performance. Part Selection Output Voltage +12 Vdc/-12 Vdc Input Voltage 36 Vdc - 75 Vdc Max. Output Current 5 A/1.5 A Max. Output Power 78 W Typical Efficiency 90% Model Number 0RXU-75TD10 Notes: 1. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers. 2. Add “G” suffix at the end of the model numbers listed above to indicate “Tray Packaging”. Absolute Maximum Ratings Parameter Input Voltage Remote On/Off Ambient Temperature Storage Temperature Min -0.3 V -0.3 V -40 °C -40 °C Typ Max 100 V 30 V 85 °C 125 °C Notes 100 V for 10 mS Max. Input Specifications Parameter Input Voltage Input Current (no load) Input Current (full load) Remote Off Input Current Input Reflected Ripple Current (rms) Input Reflected Ripple Current (pk-pk) Turn On Voltage Threshold Turn Off Voltage Threshold Min 36 V 32 V 30 V Typ 10 mA 10 mA 50 mA 34 V 31 V Max 75 V 200 mA 3A 20 mA 30 mA 100 mA 35 V 33 V With simulated source impedance of 10 uH, 5 Hz to 20 MHz; use a 100 uF/100 V electrolytic capacitor with ESR=1 ohm max at 200k Hz Notes Note: All specifications are typical at nominal input, full load at 25 °C unless otherwise stated. Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input +12 Vdc/5 A, -12 Vdc/1.5 A Dual Outputs Output Specifications Parameter Output Voltage Set Point VO1=+12 V VO2=-12 V Load Regulation VO1=+12 V VO2=-12 V Line Regulation VO1=+12 V VO2=-12 V Regulation Over Temperature Output Current VO1=+12 V VO2=-12 V Output Current Limit VO1=+12 V VO2=-12 V Short Circuit Protection Startup Time Power Up Remote On/Off Overshoot at Turn On Ripple and Noise (rms) VO1=+12 V VO2=-12 V Ripple and Noise (pk-pk) VO1=+12 V VO2=-12 V Output Capacitance Transient Response 50% ~ 75% Max Load Overshoot Settling Time VO1=+12 V 75% ~ 50% Max Load Overshoot Settling Time Overshoot Settling Time VO2=-12 V 75% ~ 50% Max Load Overshoot Settling Time 300 mV 150 uS 300 mV 150 uS 300 mV 150 uS 300 mV 150 uS 600 mV 300 uS 600 mV 300 uS 600 mV 300 uS 600 mV 300 uS Test conditions: di/dt=0.5 A/us, Vin=48 V 0 uF 75 mV 40 mV 150 mV 150 mV 1,000 uF 25 mV 10 mV 50 mV 50 mV Test conditions: 0-20 MHz Bandwidth, with a 1 uF ceramic capacitor at the output. 10 mS 7 mS 20 mS 20 mS 5% 6A 1.8 A 7.5 A 2.25 A Hiccup Mode Hiccup Mode 0.06 A 0.06 A 5A 1.5 A 1% VO 1% VO 0.02% /°C Io1=50% Imax1; Io2=50% Imax2 (-40 °C to +85 °C) 2% VO 4% VO ΔIo1=50% Imax1; Io2=50% Imax2 ΔIo2=50% Imax2; Io1=50% Imax1 Min +11.76 V -11.86 V Typ +12 V -12.1 V Max +12.24 V -12.34 V Notes Vin=48 V, lo=50% load For both VO1 and VO2 50% ~ 75% Max Load Note: All specifications are typical at nominal input, full load at 25 °C unless otherwise stated. Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input +12 Vdc/5 A, -12 Vdc/1.5 A Dual Outputs General Specifications Parameter Efficiency Switching Frequency I/O Isolation Voltage Isolation Capacitance Output Trim Range Output Over Voltage Protection VO1=+12 V VO2=-12 V Over-temperature MTBF Dimensions Inches (L × W × H) Millimeters (L × W × H) Weight 2.28 x 2.4 x 0.48 57.9 x 61.0 x 12.09 45 g Min 84% 270k Hz 90% +13.5 V -13.5 V Typ 90% 300k Hz 1500 V 1500 pF +15 V -15 V 130 °C 2,366,749 hours Max 330k Hz 110% +17 V -17 V Hiccup Mode Hiccup Mode Calculated Per Bell Core SR-332 (IO = 80% Imax; TA = 25 °C) Notes Vin = 48 V; Full Load - Note: All specifications are typical at nominal input, full load at 25 °C unless otherwise stated. Control Specifications Parameter Remote On/Off Signal Low (Unit On) Signal High (Unit Off) Min -0.3 V 3.5 V Typ Max 1.8 V 12 V Notes Active Low; Remote On/Off pin open, Unit off. Output Trim Equations Equations for calculating the trim resistor (in kΩ) given the desired adjusted voltage (Vadj) and the nominal output voltage of the converter (Vnom) are shown below. The Trim Down resistor should be connected between the Trim pin and Vo1. The Trim Up resistor should be connected between the Trim pin and COM. Only one of the resistors should be used for any given application. Rtrim _ down = 99.86 − 20.5 Vnom − Vadj Vout1 Rtrim_down Module Trim COM Rtrim _ up = 26.25 − 10 Vadj − Vnom Vout1 Module Trim Rtrim_up Note: Output voltage Vo=12.012 V COM Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input +12 Vdc/5 A, -12 Vdc/1.5 A Dual Outputs Efficiency Data 0RXU-75TD10 module 0.950 0.900 Efficiency 0.850 0.800 0.750 0.700 0.650 0.600 10%load 25%load 50%load 75%load 100%load Vin=36V Vin=48V Vin=75V Output Current Thermal Derating Curve (Vin=48 V) Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input +12 Vdc/5 A, -12 Vdc/1.5 A Dual Outputs Ripple and Noise Waveforms Ripple and noise at full load, 36 V input, ch1 (+)12 V/5 A output, (-)12 V/1.5 A Ripple and noise at full load, 48 V input, ch1 (+)12 V/5 A output, (-)12 V/1.5 A Ripple and noise at full load, 75 V input, ch1 (+)12 V/5 A output, (-)12 V/1.5 A Note: With a 1uF ceramic capacitor at the output, Ta=25 deg C. Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input +12 Vdc/5 A, -12 Vdc/1.5 A Dual Outputs Transient Response Waveforms Vout=(+)12 V 50%-75% Load Transients at Vin=36 V Vout=(+12) V 75%-50% Load Transients at Vin=36 V Vout=(-)12 V 50% - 75% Load Transients at Vin=36 V Vout=(-)12 V 75% -50% Load Transients at Vin=36 V Vout=(+)12 V 50%-75% Load Transients at Vin=48 V Vout=(+12) V 75%-50% Load Transients at Vin=48 V Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input +12 Vdc/5 A, -12 Vdc/1.5 A Dual Outputs Transient Response Waveforms (continued) Vout=(-)12 V 50% - 75% Load Transients at Vin=48 V Vout=(-)12 V 75% -50% Load Transients at Vin=48 V Vout=(+)12 V 50%-75% Load Transients at Vin=75 V Vout=(+12) V 75%-50% Load Transients at Vin=75 V Vout=(-)12 V 50% - 75% Load Transients at Vin=75 V Vout=(-)12 V 75% -50% Load Transients at Vin=75 V Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input +12 Vdc/5 A, -12 Vdc/1.5 A Dual Outputs Mechanical Outline Pin Connections Pin 1 2 3 4 5 Function -Vin FG REM +Vin +Vo1 (+12 V) Pin 6 7 8 9 10 Function COM Trim COM -Vo1 (-12 V) No Connection RoHS Compliance Complies with the European Directive 2002/95/EC, calling for the elimination of lead and other hazardous substances from electronic products. ©2007 Bel Fuse Inc. Specifications subject to change without notice. 030107 CORPORATE Bel Fuse Inc. 206 Van Vorst Street Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com FAR EAST Bel Fuse Ltd. 8F/ 8 Luk Hop Street San Po Kong Kowloon, Hong Kong Tel 852-2328-5515 Fax 852-2352-3706 www.belfuse.com EUROPE Bel Fuse Europe Ltd. Preston Technology Management Centre Marsh Lane, Suite G7, Preston Lancashire, PR1 8UD, U.K. Tel 44-1772-556601 Fax 44-1772-888366 www.belfuse.com
0RXU-75TD10_07
1. 物料型号: - 型号:ORXU-75TD10 - 特点:符合RoHS标准,具有远程开关、输出调整、短路保护、过流保护、过温保护、输出过压保护和输入欠压锁定功能。

2. 器件简介: - ORXU-75TD10是一款隔离型直流/直流转换器,工作电压范围为36 Vdc至75 Vdc,提供双输出电压,分别为+12 Vdc/5 A和-12 Vdc/1.5 A。该转换器具有高效率、高功率密度和良好的热性能。

3. 引脚分配: - 1号引脚:-Vin(负输入电压) - 2号引脚:FG(工厂调整引脚) - 3号引脚:REM(远程控制引脚) - 4号引脚:+Vin(正输入电压) - 5号引脚:+Vo1(+12V输出) - 6号引脚:COM(公共地) - 7号引脚:Trim(输出电压调整引脚) - 8号引脚:COM(公共地) - 9号引脚:-Vo1(-12V输出) - 10号引脚:无连接

4. 参数特性: - 输入电压范围:36V至75V - 输出电压:+12Vdc/-12Vdc - 最大输出电流:+12V侧5A,-12V侧1.5A - 最大输出功率:78W - 典型效率:90%

5. 功能详解: - 该转换器具备固定频率(300 kHz)、SCP/OCP(短路/过流保护)、远程开关、输出电压调整、输入欠压锁定(UVLO)、输出过压保护(OVP)和过温保护功能。

6. 应用信息: - 适用于需要隔离型直流/直流转换的应用场合,如工业控制系统、通信设备和医疗设备等。

7. 封装信息: - 封装尺寸:2.28英寸 x 2.4英寸 x 0.48英寸(57.9毫米 x 61.0毫米 x 12.09毫米) - 重量:45克