Bel Power Solutions 350DNC40-24 is a 4 kW DC/DC Converter
Series that creates DC voltages in hybrid and electric vehicles
suitable to power low voltage accessories.
Liquid cooled or convection cooled DC/DC converter operates at
input voltages from 240 to 430 VDC or 300 to 450 VDC and delivers
power range up to 4000 W / 3300 W (liquid / convection cooled
model).
Features include very high efficiency, high reliability, low output
voltage noise, and excellent dynamic response to load/input changes.
•
Very high efficiency up to 93 %
•
Input voltage range: 240 – 430 VDC (300 – 450 VDC)
•
Up to 4 kW power
•
Full galvanic isolation between input and output
•
Liquid or convection cooled models available
•
CAN bus serial interface
•
Adjustable output voltage
•
Over temperature, output overvoltage and overcurrent protection,
input and output reverse polarity protection
•
Protection degree IP65 and IP67
•
E-Mark approval no.: E13*10R00*10R05*13602*00
•
Hybrid and Electric Vehicles
350DNC40-24 SERIES
2
MODEL
DESCRIPTION
350DNC40-24-8G
Liquid cooled model
350DNC40-24-CG
Convection cooled model
300DNC40-24-8S419
Liquid cooled model
350DNC40-CON-KIT-8G
Mating connectors kit – Signal connector housing and pins, HV connector assembled with 3 m cable
350DNC40-CON-KIT-9G
Mating connectors kit - housing and pins
PARAMETER
DESCRIPTION / CONDITION
MIN
350DNC40-24-8G, 350DNC40-24-CG
300DNC40-24-8S419
350DNC40-24-8G, 350DNC40-24-CG
300DNC40-24-8S419
Input Voltage
Input Current
Efficiency
@ Vin = 350 VDC, Vo = 28 V, Ionom = 143 A
Input Line Interruption
Converter
shutdown
240
300
NOM
350
MAX
430
450
19
16
92
240
300
30
Inrush Current
External pre-charging circuit required
PARAMETER
DESCRIPTION / CONDITION
Output Voltage
Vo to be trimmed via CAN BUS, 10 bit resolution
Output Power
ADC
VDC
µF
MIN
NOM
MAX
UNIT
22
28
32
VDC
Liquid cooled model
Convection cooled model
Liquid cooled model
Convection cooled model
Output Current
VDC
%
350DNC40-24-8G, 350DNC40-24-CG
300DNC40-24-8S419
Input Capacitance
UNIT
143
120
ADC
4000
3300
W
Line Regulation
Vinmin - Vinmax, @ 60 A, T_coolant = 70°C
- 0.10
+ 0.10
VDC
Load Regulation
Iout 10 to 90% load, T_coolant = 70°C
- 0.15
+ 0.15
VDC
Output Voltage Set Point
@ 60 A, T_coolant = 25°C
28.1
VDC
+0.05
%/°C
460 *
300 *
mVp-p
+1400
1000
mV
μs
Thermal Drift
Periodic and Random Deviation
Transient Response
27.9
28
-0.05
@ 28 VDC / Nominal load (Differential Mode 20 MHz)
CAN high / low (Differential Mode 20 MHz)
Load step 1: 10 to 50 % and back
Load step 2: 50 to 100 % and back
Voltage over/under shoot:
Response time within 1 % of VoSET:
-1400
Turn-on Overshoot
Vonom,
很抱歉,暂时无法提供与“350DNC40-24-8G”相匹配的价格&库存,您可以联系我们找货
免费人工找货