ULP180
The ABC180 Series of ultra low profile open frame power supplies
feature a wide universal AC input range of 80 – 264 VAC, offering up
to 180 W of output power with 13 CFM, or up to 120 W with convection
cooling in a compact footprint, with a variety of isolated single output
voltages.
The high efficiency and high power density of the ABC family ensures
minimal power loss in end-use equipment, thereby facilitating higher
reliability, easier thermal management and meets regulatory approvals
for environmentally-friendly end products.
These power supplies are ideal for broad range of telecom, datacom,
industrial equipment and other applications.
•
4 x 2 x 0.75 Inch Form Factor
•
180 Watts with Forced Air Cooling
•
Efficiencies up to 92%
•
-40 to 70 °C Operating Temperature
•
IEC / EN / UL 62368-1 Compliant
•
12 V / 0.5 A Fan Output
•
Thermal Shut-Down Feature
•
3.37 million hours, Telcordia -SR332-issue 3 MTBF
•
No Load Power < 0.5 W
•
Instrumentation
•
Renewable Energy
•
Lighting
•
Test and Measurement
•
Industrial Applications
•
Robotics
ABC180 Series
2
•
ABC180-1T12L
Screw Terminal
ABC180-1012L
Header Molex Connector
ABC180-1T15L
Screw Terminal
ABC180-1015L
Header Molex Connector
ABC180-1T24L
Screw Terminal
ABC180-1024L
Header Molex Connector
ABC180-1T30L
Screw Terminal
ABC180-1030L
Header Molex Connector
ABC180-1T48L
Screw Terminal
ABC180-1048L
Header Molex Connector
ABC180-1T58L
Screw Terminal
ABC180-1058L
Header Molex Connector
COVER-180-XBC 2
Metal Cover Kit (accessory)
1
2
Applied Computing
•
Wireless Communication
12 V
9.37 A
10 A
15 A
180 W
15 V
7.5 A
8A
12 A
180 W
24 V
4.68 A
5A
7.5 A
180 W
30 V
3.75 A
4A
6A
180 W
48 V
2.34 A
2.5 A
3.75 A
180 W
58 V
1.94 A
2.07 A
3.1 A
180 W
Class II version available. Add suffix “-2” at the end of the Model Number
When used in Cover Kit, de-rate output power to 70 % under all operating conditions.
Specifications are for nominal input voltage, 25°C unless otherwise stated.
Input Voltage
Universal
(Derate from 100% at 100 VAC to 77% at 80 VAC)
Input Frequency
80 – 264 VAC / 390 VDC
47 – 63 Hz
Input Current
115 VAC:
230 VAC:
2.2 A max.
1.1 A max.
No Load Power
Typical
< 0.5 W
115 VAC:
230 VAC:
264 VAC:
Typical (N/A For Class II Option)
Touch current
PFC
PWM
25 A
45 A
75 A
300 µA
< 100 µA
70 – 130 kHz
50 – 80 kHz
Inrush Current
Leakage Current
Switching Frequency
tech.support@psbel.com
ABC180 Series
Output Voltage
3
Line Regulation 4
From 12 V to 58 V
180 W
up to 120 W
92%
90%
88%
10 ms
16 ms
> 0.95
0.90
± 0.5%
Load Regulation 4
± 1%
Output Power 3
Efficiency
Hold-up Time
Power Factor
Refer to Model selection table
13 CFM (forced air cooling)
Convection (natural cooling)
48 V, 58 V:
24 V, 30 V:
12 V, 15 V:
At 180 W:
At 120 W:
115 VAC:
230 VAC:
Minimum Load
Transient Response
Ripple
4, 5
0.0 A
25% step load change, at 0.1 A/ µs slew rate,
50% duty cycle, 50 Hz = 4%
24, 30, 48 & 58 V outputs
12 V & 15 V outputs
Output Voltage Adjustment 6
Rise Time
Typical
recovery time < 5 ms
1.0 % max.
2.0 % max.
± 3%
55 ms
Set Point Tolerance 4
± 1%
Over Current Protection
> 110%
Over Voltage Protection
110 to 140%
Short Circuit Protection
Cooling
3
4
5
6
7
8
Hiccup mode
With 13 CFM forced air cooling (100 to 264 VAC) 7
With natural convection cooling (100 to 264 VAC) 8
180 W
Up to 120 W
Combined output power of main output, fan supply shall not exceed max. power rating.
Fan supply output voltage tolerance including set point accuracy, line and load regulation is ± 10% and ripple and noise
is less than 10%.
Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Electrolytic capacitor) in parallel with a 0.1 µF capacitor at rated line
voltage and load ranges.
Adjustment potentiometer is located on the SMT side of the PCB
Refer to Mechanical Drawing
Refer to Derating Curve
Conducted Emissions
Input Current Harmonics
EN 55032-B, CISPR22-B, FCC PART15-B
EN 55032 A
with external core (King core K5B RC 25x12x15-M in input cable)
EN 61000-3-2
Pass
Pass
Level B
Class D
Voltage Fluctuation and Flicker
EN 61000-3-3
Pass
ESD Immunity
EN 61000-4-2
Level 3, Criterion A
Radiated Field Immunity
EN 61000-4-3
Level 3, Criterion A
Electrical Fast Transient Immunity
EN 61000-4-4
Level 3, Criterion A
Surge Immunity
EN 61000-4-5
Level 3, Criterion A
Conducted Immunity
EN 61000-4-6
Level 3, Criterion A
Magnetic Field Immunity
EN 61000-4-8
Level 3, Criterion A
Voltage Dips, Interruptions
EN 61000-4-11
Criterion A & B
Radiated Emissions
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00879_AF
ABC180 Series
4
Isolation Voltage
Input to Output: (for ITE applications)
Input to GND: (Not Applicable for Class II Option)
Safety Standard(s)
EN / IEC / UL 62368-1(Ed .3)
Agency Approvals
Nemko, UL, C-UL
CE mark
Complies with LVD Directive
Operating Temperature
-40 to 0°C startup guaranteed, with spec deviation 9
Storage Temperature
Relative Humidity
Altitude
MTBF
9
4000 VDC
2500 VDC
-40 to +70°C
-40 to +85°C
Non-condensing
Operating:
Non-operating:
Telcordia -SR332-issue 3
5% to 95%
16,000 ft.
40,000 ft.
3.37 million hours
Output ripple can be more than 10% of the output voltage.
Figure 1. Power Derating Curves
tech.support@psbel.com
ABC180 Series
5
AC Input Connector
J1
Pin 1
Pin 2
Pin 3
AC Line
Not Fitted
AC Neutral 10
DC Output Connector
J2
Pin 1, 2, 3
Pin 4. 5. 6
V1 +VE
V1 -VE
Aux (Fan) Output
J3
Pin 1
Pin 2
FAN +VE
FAN -VE
10
Molex: 26-60-4030
Mating: 09-50-3031; Pins: 08-50-0106
Option 1 (Screw Terminal): Molex: 39357 Series or equivalent
Option 2 (Molex Connector): Molex: 26-60-4060
Mating: 09-50-3061; Pins: 08-50-0106
AMP: 640456-2
Mating: 640440-2
Fusing on neutral for ITE model is optional.
Weight
approx. 200 g
Dimensions
101.6 x 50.8 x 19.05 mm (4 x 2 x 0.75 in)
Figure 2. Mechanical Drawing – Option 1 (Output Connector – Screw Terminal)
NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following:
1
Stand off, used to mount PCB has OD of 5.4 mm max.
2
Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
3
Washer, if used, to have dia of 6.5 mm max.
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00879_AF
6
ABC180 Series
Figure 3. Mechanical Drawing – Option 2 (Output Connector – Header Molex)
NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following:
4
Stand off, used to mount PCB has OD of 5.4 mm max.
5
Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
6
Washer, if used, to have dia of 6.5 mm max.
tech.support@psbel.com
ABC180 Series
7
Figure 4. Mechanical Drawing – Cover Kit Option
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00879_AF