WLT200
The ABC201 Series of open-frame power supplies, with its wide
universal 90-264 VAC input range and high power density, is
available at 200 W of output power and a variety of single output
voltages.
The high efficiency and high power density of the ABC family ensures
minimal power loss in end-use equipment, thereby facilitating higher
reliability, easier thermal management and meets regulatory
approvals for environmentally-friendly end products.
These power supplies are ideal for telecom, datacom, industrial
equipment and other applications.
•
5 x 3 x 1.5 Inch Form Factor
•
200 W with Forced Air Cooling
•
High Efficiency > 88%
•
12 V Fan Output
•
5 V Standby Output
•
Remote Sense
•
Output Voltage Adjustability
•
IEC Protection Class Options:
−
Class I: Earthing Tab J4 (no suffix)
−
Class II: No Earthing Tab (-2 suffix)
•
IEC / EN / UL 62368-1 Compliant
•
Metal Cover Kit Available (optional accessory)
•
Instrumentation
•
Renewable Energy
•
Lighting
•
Test and Measurement
•
Industrial Applications
•
Robotics
ABC201 Series
2
•
MODEL 1
CONNECTOR
ABC201-1005G
JST (Header)
ABC201-1T05G
Screw Terminal
ABC201-1012G
JST (Header)
ABC201-1T12G
Screw Terminal
ABC201-1015G
JST (Header)
ABC201-1T15G
Screw Terminal
ABC201-1024G
JST (Header)
ABC201-1T24G
Screw Terminal
ABC201-1030G
JST (Header)
ABC201-1T30G
Screw Terminal
ABC201-1048G
JST (Header)
ABC201-1T48G
Screw Terminal
COVER-201-XBC 3
1
2
3
•
Applied Computing
MAX LOAD
Wireless Communication
2
OUTPUT
VOLTAGE
CONVECTION
5 VDC
16.67 A
12 VDC
13.33 A
16.67 A
0.0 A
200 W
15 VDC
10.67 A
13.33 A
0.0 A
200 W
24 VDC
6.67 A
8.33 A
0.0 A
200 W
30 VDC
5.33 A
6.67 A
0.0 A
200 W
48 VDC
3.33 A
4.17 A
0.0 A
200 W
MIN LOAD
300 LFM
26.0 A
0.0 A
POWER
130 W
175 W
35.0 A
Metal Cover Kit (accessory)
Class I products have an Earthing tab. For Class II version (without Earthing tab) add suffix -2 (e.g.: ABC201-1012G-2).
Combined output power from V1, VSTBY and VFAN should not exceed the total output power rating.
When used in Cover Kit, de-rate output power to 70 % under all operating conditions.
Specifications are for nominal input voltage, 25°C unless otherwise stated.
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Input Voltage
Universal
90 – 264 VAC / 120 – 390 VDC
Input Frequency
Input Current
Inrush Current
Leakage Current
47 – 63 Hz
120 VAC:
230 VAC:
120 VAC:
230 VAC:
120 VAC:
230 VAC:
No Load Power
Switching Frequency
2.4 A max.
1.2 A max.
35 A max.
65 A max.
< 150 µA
< 300 µA
0.8 W
PFC converter (variable)
Resonant converter (variable)
35 to 250 kHz, 90 kHz typical
35 to 250 kHz, 90 kHz typical
tech.support@psbel.com
ABC201 Series
3
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Output Voltage
Refer to Model Selection table
5 V to 48 V
Output Power 4
Peak Power: 250 W for 2 s
160 to 200 W
Fan Output 5
@5A
120 VAC:
230 VAC:
120 VAC / 230 VAC:
120 VAC:
230 VAC:
12 V
84% typical
86% typical
10 ms
0.99
0.95
± 0.5%
Efficiency
Hold Up Time
Power Factor
Line Regulation
Load Regulation
Transient Response
Ripple
6
50 to 100% load change, 50 Hz, 50% duty cycle, 0.1A / µs
All outputs
Rise Time
± 2.0%
< 10%,
recovery time < 5 ms
1.0 % max
< 100 ms
Set Point Accuracy
Main output
± 1%
Output Voltage Adjustment
V1
±3%
Over Current Protection
110% typical above rating
Over Voltage Protection
V1
Short Circuit Protection
Short term, Automatic recovery
Cooling
4
5
6
110 to 150%
Convection
83 W (5 V model), 160 W (other models)
300 LFM
175 W (5 V model), 200 W (other models)
Derate output power linearly to 80% from 90 VAC to 80 VAC input.
Fan output voltage tolerance is +/-20%. During V1 full load, VFAN needs min. 20 mA load to be within regulation band.
Peak current for fan output is 1 A.
Ripple is 2% up to 20% load and < 1% above 20% load. Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Electrolytic
capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
Conducted Emissions
EN 55032-B, CISPR22-B, FCC PART15-B
Pass
Radiated Emissions
EN 55032 B
Pass
Input Current Harmonics
EN 61000-3-2
Class D
Voltage Fluctuation and Flicker
EN 61000-3-3
Pass
ESD Immunity
EN 61000-4-2
Level 3, Criterion A
Radiated Field Immunity
EN 61000-4-3
Level 3, Criterion A
Electrical Fast Transient Immunity
EN 61000-4-4
Level 3, Criterion A
Surge Immunity
EN 61000-4-5
Level 3, Criterion A
Conducted Immunity
EN 61000-4-6
Level 3, Criterion A
Magnetic Field Immunity
EN 61000-4-8
Level 3, Criterion A
Voltage Dips, Interruptions
EN 61000-4-11
Criterion A & B
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00284_AG
ABC201 Series
4
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Isolation Voltage
Input to Output:
Min. 4000 VDC
Safety Standards
EN / IEC / UL 62368-1 (Ed.3)
Agency Approvals
Nemko, UL
CE mark
Complies with LVD Directive
PARAMETER
Operating Temperature
7
DESCRIPTION / CONDITION
SPECIFICATION
-20 to 0°C start-up is guaranteed
-20 to 70°C
Storage Temperature
-40 to 85° C
Humidity
Non Condensing
95%
Altitude
Operating:
Non-Operating:
10,000 ft.
40,000 ft.
Reliability
MTBF according to Telcordia –SR332-Issue 3
1.6 million hours
7
Refer to derating curves
Convection load: 83 W up to 40 °C
De-rate above 40 °C @ 1.89% per °C
Forced air cooled load: 130 W up to 50°C
(for screw terminal version)
De-rate above 50 °C @ 1.63% per °C
Forced air cooled load: 175 W up to 50°C
(for JST connector version)
De-rate above 50 °C @ 2.5% per °C
Convection load: 160 W up to 40 °C
De-rate above 40 °C @ 2% per °C
Forced air cooled load: 200 W up to 50°C
De-rate above 50 °C @ 2.5% per °C
Figure 1. Derating Curves
tech.support@psbel.com
ABC201 Series
5
PARAMETER
DESCRIPTION / CONDITION
Power Good Signal
TTL signal goes high after main output is in regulation band. Delay is 0.1 to 0.3 sec.
Power Fail Signal
TTL signal goes low 1 ms advance before output goes out of regulation due to mains failure
Remote Sense
Compensates for 200 mV cable drop
Remote ON / OFF
To turn on PSU short remote pin to ground
CONNECTOR
PIN
DESCRIPTION / CONDITION
Pin 1
AC Neutral
Pin 2
AC Line
MANUFACTURER / PN
Molex: 26-60-4030 or equivalent;
Mating: 09-50-3031; Pins: 08-50-0106
Option 1:
Tyco: 2-1776112-3 or equivalent
Mating: 13 AWG wire
Option 2:
JST: B6P-VH-B (LF) (SN) or B6P-VH (LF) (SN) or equivalent
Mating: VHR-6M; Pins: SVH-41T-P1.1
AC Input Connector
J1
DC Output Connector
J2
Pin 1,2,3
Pin 4,5,6
RTN
Vout
Signals & Aux Power 8
J3
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
+VE Remote Sense
VFAN (+12 V/0.5 A)
-VE Remote Sense
Remote ON/OFF
VSTBY (+5 V/1 A, +/-5%)
RTN (Signal)
Power Fail
Power Good
Earth 8 (Spade Connector)
J4
8
9
Molex: 22-23-2081 or equivalent
Mating: 22-01-2087, Pins: 08-50-0113
Molex: 19705-4301 or equivalent
Mating: 190030001
PSU is supplied with J3 housing, pin-4 and pin-6 shorted to enable main output without remote on/off feature
Class I product only
PARAMETER
DESCRIPTION / CONDITION
Weight
325 g (0.72 lbs.)
Dimensions
127.0 x 76.2 x 38.1 mm (5 x 3 x 1.5 in)
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00284_AG
ABC201 Series
6
Figure 2. Mechanical Drawing
1
2
3
NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following:
Stand off, used to mount PCB has OD of 5.4 mm max.
Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
Washer, if used, to have dia of 6.5 mm max.
tech.support@psbel.com
ABC201 Series
7
Figure 3. Mechanical Drawing with Cover Kit
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00284_AG