0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ABC225-1T12L

ABC225-1T12L

  • 厂商:

    POWER-ONE

  • 封装:

    -

  • 描述:

    AC/DC CONVERTER 12V 113W

  • 数据手册
  • 价格&库存
ABC225-1T12L 数据手册
WLP225 The ABC225 Series of open frame power supplies feature a wide universal AC input range of 90 – 264 VAC, offering up to 225 W of output power in a compact 4 x 2 x 1 inch footprint, with a variety of isolated single output voltages. The high efficiency and high power density of the ABC family ensures minimal power loss in end-use equipment, thereby facilitating higher reliability, easier thermal management and meets regulatory approvals for environmentally-friendly end products. These power supplies are ideal for telecom, datacom, industrial equipment and other applications. Key Features & Benefits • 2 x 4 x 1 Inch Form Factor • 225 W with Forced Air Cooling & 130 W with Convection Cooling • Efficiencies up to 94% • No Load Power < 0.5 W • -40 to 70°C Operating Temperature • 12 V / 0.5 A Fan Output, Thermal Shut-Down Feature • 3.37 Million Hours, Telcordia -SR332-Issue 3 MTBF • IEC/EN/UL 62368-1 Certified • CCC (China Compulsory Certification approval) • Approved with metal enclosures/accessories • RoHS Compliant Applications • Instrumentation • Renewable Energy • Lighting • Test and Measurement • Industrial Applications • Robotics • Applied Computing • Wireless Communication ABC225 Series 2 1. MODEL SELECTION MAX. LOAD MODEL NUMBER 1 DESCRIPTION CONVECTION 50˚C (112.5 W) CONVECTION 40˚C (120 W) 13 CFM (225 W) 12 V 9.37 A 10.00 A 18.75 A 225 W 15 V 7.50 A 8.00 A 15.00 A 225 W 24 V 4.68 A 5.00 A 9.37 A 225 W 30 V 3.75 A 4.00 A 7.50 A 225 W 48 V 2.34 A 2.50 A 4.68 A 225 W 58 V 1.94 A 2.07 A 3.88 A 225 W ABC225-1T12L ABC225-1012L ABC225-1T15L ABC225-1015L ABC225-1T24L ABC225-1024L ABC225-1T30L ABC225-1030L ABC225-1T48L ABC225-1048L ABC225-1T58L ABC225-1058L Screw Terminal Molex Connector Screw Terminal Molex Connector Screw Terminal Molex Connector Screw Terminal Molex Connector Screw Terminal Molex Connector Screw Terminal Molex Connector COVER-225-XBC 2 Metal cover kit (accessory) 1 2 2. POWER VOLTAGE Class II version available. Add suffix “-2” at the end of the Model Number When used in Cover Kit, de-rate output power to 70 % under all operating conditions. INPUT SPECIFICATIONS Specifications are for nominal input voltage, 25°C unless otherwise stated. PARAMETER DESCRIPTION / CONDITION SPECIFICATION Input Voltage Universal (Derate from 100% at 100 VAC to 90% at 85 VAC) 85 – 264 VAC / 390 VDC Input Frequency 47 – 63 Hz Input Current 115 VAC: 230 VAC: 2.2 A max. 1.1 A max. No Load Power Typical < 0.5 W 115 VAC: 230 VAC: 264 VAC: Typical (N/A for Class II Option) Touch current: 25 A 45 A 75 A 300 µA < 100 µA Power Factor With Full Load > 0.95 Switching Frequency PFC: PWM: 70 – 130 kHz 50 – 80 kHz Inrush Current Leakage Current tech.support@psbel.com ABC225 Series 3. 3 OUTPUT SPECIFICATIONS PARAMETER Output Voltage Output Power 3 Efficiency Hold-up Time DESCRIPTION / CONDITION SPECIFICATION Refer to Model selection table From 12 V to 58 V With 13 CFM: Convection: 48 V: 24 V, 30 V: 12 V, 15 V: 225 W: 110 W: 225 W Up to 120 W 94% 93% 92% 10 ms 16 ms Line Regulation 5 ± 0.5% Load Regulation 5 ± 0.5% Minimum Load 0.0 A Transient Response Ripple 4, 5 Rise Time Set Point Tolerance 25% step load change, at 0.1A/µs slew rate, 50% duty cycle, 50 Hz = 4% Recovery time < 5 ms For all outputs 1.0 % max Typical 55 ms 5 ± 1% Output Voltage Adjustment 6 ± 3% Over Current Protection >110% Over Voltage Protection 110 to 140% Short Circuit Protection Hiccup mode Cooling With 13 CFM forced air cooling (100 to 264 VAC) 7 With natural convection cooling (100 to 264 VAC) 8 3 4 5 6 7 8 9 4. 225 W Up to 120 W 9 Combined output power of main output, fan supply shall not exceed max. power rating. Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Electrolytic capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. Fan supply output voltage tolerance including set point accuracy, line and load regulation is +/-15 % and ripple and noise is less than 10 %. With V1 fully loaded, Vfan need to have min load of 20 mA to be within regulation band. Adjustment potentiometer is located on the SMT side of the PCB Refer to Mechanical Drawing Refer to Derating Curve For improved thermal performance of ABC225 up to 130 W convection cooling, enquire with Sales Rep prior to placing an order. EMC SPECIFICATIONS PARAMETER DESCRIPTION / CONDITION SPECIFICATION Conducted Emissions EN 55032-B, CISPR22-B, FCC PART15-B Pass Radiated Emissions EN 55032 A; With external core (King core K5B RC 25x12x15-M in input cable) Pass Level B Input Current Harmonics EN 61000-3-2 Class D Voltage Fluctuation and Flicker EN 61000-3-3 Pass ESD Immunity EN 61000-4-2 Level 3, Criterion A Radiated Field Immunity EN 61000-4-3 Level 3, Criterion A Electrical Fast Transient Immunity EN 61000-4-4 Level 3, Criterion A Surge Immunity EN 61000-4-5 Level 3, Criterion A Conducted Immunity EN 61000-4-6 Level 3, Criterion A Magnetic Field Immunity EN 61000-4-8 Level 3, Criterion A Voltage Dips, Interruptions EN 61000-4-11 Criterion A & B Asia-Pacific +86 755 298 85888 Europe, Middle East +353 61 49 8941 North America +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00554_AJ ABC225 Series 4 5. SAFETY SPECIFICATIONS PARAMETER DESCRIPTION / CONDITION SPECIFICATION Isolation Voltage Input to Output: (for ITE application) Input to GND: (N/A for Class II Option) 3000 VAC 1500 VAC Safety Standard(s) IEC 62368-1:2018, IEC 60950-1(ed.2);am1;am2, EN 60950-1:2006;A11;A1;A12;A2, UL 62368-1 and CAN/CSA C22.2 No. 62368-1:19, UL 60950-1 and CAN/CSA C22.2 No. 60950-1-07, GB4943.1-2011;GB9254-2008;GB17625.1-2012 Agency Approvals Nemko, UL, C-UL, CCC CE mark Complies with LVD Directive 6. ENVIRONMENTAL SPECIFICATIONS PARAMETER DESCRIPTION / CONDITION SPECIFICATION Operating Temperature -40 to 0°C startup guaranteed, with spec deviation 10 -40 to +70°C Storage Temperature -40 to +85°C Relative Humidity Non-condensing 5% to 95% Altitude Operating: Non-operating: 16,000 ft. 40,000 ft. Reliability MTBF according to Telcordia -SR332-Issue 3: 3.37 million hours 10 Output ripple can be more than 10% of the output voltage. Convection load: 120 W up to 40 °C De-rate between 40-50 °C @ 0.625% per °C De-rate above 50 °C @ 2.33% per °C Forced air cooled load: 225 W up to 50°C De-rate above 50 °C @ 2.5% per °C Power de-rating with Cover Kit Convection load: 84 W up to 40 °C De-rate between 40-50 °C @ 0.625% per °C De-rate above 50 °C @ 2.33% per °C Figure 1. Derating Curves tech.support@psbel.com ABC225 Series 5 Figure 2. Efficiency Graph at 115 VAC Figure 3. Efficiency Graph at 230 VAC 7. CONNECTOR & PIN DESCRIPTION CONNECTOR PIN DESCRIPTION/CONDITION MANUFACTURER / PN AC Line Not Fitted AC Neutral Molex: 26-60-4030 Mating: 09-50-3031; Pins: 08-50-0106 AC Input Connector J1 Pin 1 Pin 2 Pin 3 DC Output Connector J2 Pin 1,2,3 Pin 4,5,6 V1 +VE V1 - VE Pin 1 Pin 2 FAN +VE FAN - VE Aux (Fan) Output 8. J3 Screw Terminal (Option 1) Molex Connector (Option 2) Molex: 39357 Series or equivalent Molex: 26-60-4060 Mating: 09-50-3061; Pins: 08-50-0106 AMP: 640456-2 Mating: 640440-2 MECHANICAL SPECIFICATIONS PARAMETER DESCRIPTION/CONDITION Weight 200 g approx. Dimensions 50.8 x 101.6 x 25.4 mm (2 x 4 x 1 inch) Asia-Pacific +86 755 298 85888 Europe, Middle East +353 61 49 8941 North America +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00554_AJ ABC225 Series 6 Figure 4. Mechanical Drawing – Screw Terminal (Option 1) Figure 5. Mechanical Drawing – Molex Connector (Option 2) tech.support@psbel.com ABC225 Series 7 Figure 6. Mechanical Drawing – With Cover Kit NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following: 1 2 3 Stand off, used to mount PCB has OD of 5.4 mm max. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. Washer, if used, to have dia of 6.5 mm max. For more information on these products consult: tech.support@psbel.com NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. Asia-Pacific +86 755 298 85888 Europe, Middle East +353 61 49 8941 North America +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00554_AJ
ABC225-1T12L 价格&库存

很抱歉,暂时无法提供与“ABC225-1T12L”相匹配的价格&库存,您可以联系我们找货

免费人工找货