WLT300
The ABC300 Series of open-frame power supplies, with its wide
universal 90-264 VAC input range and high power density, is available
at 300 W of output power and a variety of single output voltages.
The high efficiency and high power density of the ABC family ensures
minimal power loss in end-use equipment, thereby facilitating higher
reliability, easier thermal management and meets regulatory approvals
for environmentally-friendly end products.
These power supplies are ideal for telecom, datacom, industrial
equipment and other applications.
Key Features & Benefits
•
5 x 3 x 1.5 inch form factor
•
200 W convection cooled
•
No minimum load required
•
5 V Standby output
•
12 V Fan output
•
Inhibit & Power Good signals
•
IEC Protection Class Options:
o Class I: Earth pin J4 (no suffix)
o Class II: No Earth pin (-2 suffix)
•
IEC / EN / UL 62368-1 Compliant
•
RoHS Compliant
•
CE marked
Applications
•
Instrumentation
•
Renewable Energy
•
Lighting
•
Test and Measurement
•
Industrial Applications
•
Robotics
•
Applied Computing
•
Wireless Communication
ABC300 Series
2
1.
MODEL SELECTION
MODEL
CONNECTOR
OUTPUT
VOLTAGE
MAX LOAD
300 LFM
MINIMUM
LOAD
RIPPLE &
NOISE 1
POWER
CONVECTION
ABC300-1T05G
Screw Terminal
5 VDC
28.0 A
40.0 A
0.0 A
2%
200 W
ABC300-1T12G
Screw Terminal
12 VDC
16.67 A
25.0 A
0.0 A
2%
300 W
ABC300-1T15G
Screw Terminal
15 VDC
13.33 A
20.0 A
0.0 A
2%
300 W
ABC300-1T24G
Screw Terminal
24 VDC
8.33 A
13.54 A
0.0 A
2%
325 W
ABC300-1T30G
Screw Terminal
30 VDC
6.67 A
10.83 A
0.0 A
2%
325 W
ABC300-1T48G
Screw Terminal
48 VDC
4.17 A
6.77 A
0.0 A
2%
325 W
Cover-300-XBC 2
Metal cover kit accessory
1
2
2.
Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Electrolytic capacitor) in parallel with a 0.1 µF capacitor at rated line voltage
and load ranges.
When used in Cover Kit, de-rate output power to 70 % under all operating conditions.
INPUT SPECIFICATIONS
Specifications are for nominal input voltage, 25°C unless otherwise stated.
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Input Voltage
Universal
90 – 264 VAC / 120 – 390 VDC
Input Frequency
Input Current
120 VAC
230 VAC
No Load Power
Inrush Current
Leakage Current
Switching Frequency
120 VAC
230 VAC
120 VAC
230 VAC
PFC converter (fixed)
Resonant converter (variable)
47 to 63 Hz
3.2 A max
1.65 A max
0.8 W
35 A max
65 A max
< 150 μA
< 300 μA
80 kHz typical
35 to 250 kHz, 90 kHz typical
tech.support@psbel.com
ABC300 Series
3.
3
OUTPUT SPECIFICATIONS
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Output Voltage 3
12 to 48 V
Stand-by Output 4
5 VDC
Output Power
5, 6
Efficiency
Hold Up Time
Power Factor
Derate linearly to 80% from 90 VAC to 80 VAC input.
120 VAC
230 VAC
120 / 230 VAC
120 VAC
230 VAC
200 to 325 W
88% typical
92% typical
10 ms
0.98
0.95
± 0.5 %
Line Regulation
Load Regulation
Transient Response
±2%
50% to 100% load change, 50 Hz, 50% duty cycle, 0.1 A/μs,
< 10 %, recovery time < 5 ms
Rise Time
< 100 ms
Set Point Tolerance
±1%
Voltage Output Adjustment
Over Voltage Protection
±3%
Automatic recovery
110 to 150 %
Over Current Protection
110 to 150 %
Short Circuit Protection
Short term, automatic recovery
Over Temperature Protection
Automatic Recovery
Convection
Cooling
7
With 300 LFM
3
4
5
6
7
4.
5 V model
12, 15, 24, 30 & 48 V models
5 V model
12 &15 V models
24, 30 & 48 V models
110° C primary heat sink
140 W max
200 W max
200 W max
300 W max
325 W max
Peak current rating on main output is 120% of max., lasting < 30 s with a maximum 10% duty cycle.
Standby output voltage tolerance including set point accuracy, line and load regulation is +/-10%. Ripple and noise is less than 5%.
Combined output power of main output, fan supply and standby supply shall not exceed max. power rating.
Derate output power linearly to 80% from 90 VAC to 80 VAC input.
Refer de-rating curves to determine output power over the entire operating temperature range
EMC SPECIFICATIONS
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Conducted Emissions
EN 55032-B, CISPR22-B, FCC PART15-B
Pass
Radiated Emissions
EN 55032 A;
With external core (King core K5B RC 25x12x15-M in input cable)
Pass
Level B
Input Current Harmonics
EN 61000-3-2
Class D
Voltage Fluctuation and Flicker
EN 61000-3-3
Pass
ESD Immunity
EN 61000-4-2
Level 3, Criterion A
Radiated Field Immunity
EN 61000-4-3
Level 3, Criterion A
Electrical Fast Transient Immunity
EN 61000-4-4
Level 3, Criterion A
Surge Immunity
EN 61000-4-5
Level 3, Criterion A
Conducted Immunity
EN 61000-4-6
Level 3, Criterion A
Magnetic Field Immunity
EN 61000-4-8
Level 3, Criterion A
Voltage Dips, Interruptions
EN 61000-4-11
Criterion A & B
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00285_AG
ABC300 Series
4
5.
SAFETY SPECIFICATIONS
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Isolation Voltage
4000 VAC / VDC
Agency Approvals
Input to Output:
IEC 62368-1:2014, EN 62368-1:2014; A11, UL 62368-1 and
CAN/CSA C22.2 No. 62368-1-14
Nemko, UL
CE mark
Complies with LVD Directive
Safety Standards
6.
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Operating Temperature
Refer to de-rating curves
-20 to 0°C start-up is guaranteed
-20 to 70°C
Storage Temperature
-40 to 85° C
Relative Humidity
Non-Condensing
Operating:
Non-Operating:
MTBF according to Telcordia –SR332-issue 3
Altitude
Reliability
7.
95% Rh
10,000 ft.
40,000 ft.
1.77 million hours
SIGNALS
PARAMETER
DESCRIPTION / CONDITION
Power Good 8
TTL signal goes high after main output is within regulation band, delay is 0.1 to 0.3 s
Remote On/ Off
To turn on PSU short remote pin to ground
Remote Sense
Compensates for 200 mV drop
8
Power good signal cannot be used as a current source. Internal pull up resistor from PG signal to 5V is 10K. It is recommended to use
external transistor if intended to source current.
8. CONNECTOR & PIN DESCRIPTION
CONNECTOR
PIN
DESCRIPTION / CONDITION
AC Input Connector
J1
DC Output Connector
J2
Pin 1
Pin 2
RTN
V1
J3 9
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
REMOTE ON/OFF
RTN
VFAN (+12 V/0.5 A)
-VE REMOTE SENSE
VSTBY (+5 V/2 A, +/-5%)
+VE REMOTE SENSE
RTN
POWER GOOD
Molex: 22-23-2081
Mating: 22-01-2087; Pins: 08-50-0113
(Class I product only)
Molex: 19705-4301
Mating: 190030001
Signal Connector
Earth (Spade Connector)
9
J4
AC LINE
AC NEUTRAL
MANUFACTURER / PN
Pin 1
Pin 2
Molex: 26-60-4030
Mating: 09-50-3031; Pins: 08-50-0106
6-32 inches Screw Pan HD
Mating: Designed to accept Ring Tongue Terminal AMP : 8-31886-1,
wherein one 16 AWG (max) wire can be crimped.
Note: One Ring Tongue Terminal with 16 AWG is recommended for
current up to 11 A only.
Use multiple tongue terminals with wire for more current.
PSU is supplied with J3 housing, pin-1 and pin-2 shorted to enable main output without remote on/off feature.
tech.support@psbel.com
ABC300 Series
5
9. DERATING CURVES
The de-rating curves are valid for input voltages of 115 to 264 VAC. Below 115 VAC to 90 VAC the convection rating is 180 W max.
Forced air cooled load: 200 W up to 40°C
De-rate above 40 °C @ 1.67% per °C
Convection load: 140 W up to 40 °C
De-rate above 40 °C @ 1.67% per °C
Forced air cooled load: 300 W up to 50°C
De-rate above 50 °C @ 2.5% per °C
Convection load: 200 W up to 40 °C
De-rate between 40-50 °C @ 1% per °C
De-rate above 50 °C @ 2.5% per °C
Forced air cooled load: 325 W up to 50°C
De-rate above 50 °C @ 2.5% per °C
Convection load: 200 W up to 40 °C
De-rate between 40-50 °C @ 1% per °C
De-rate above 50 °C @ 2.5% per °C
Figure 1. Derating Curves
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00285_AG
ABC300 Series
6
10. MECHANICAL SPECIFICATIONS
PARAMETER
DESCRIPTION / CONDITION
Weight
450 g (0.99 lbs)
Dimensions
127.0 x 76.2 x 38.1 mm (5.0 x 3.0 x 1.5 inch)
Figure 2. Mechanical Drawing
tech.support@psbel.com
ABC300 Series
7
Figure 3. Mechanical Drawing with Cover Kit
NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following:
1
Stand off, used to mount PCB has OD of 5.4 mm max.
2
Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
3
Washer, if used, to have dia of 6.5 mm max.
For more information on these products consult: tech.support@psbel.com
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00285_AG