WLT40
The ABC40 Series of open-frame power supplies, with its wide
universal 90 – 264 VAC input range and high power density, is
available at 40 W of output power and a variety of single and multiple
output voltages.
The high efficiency and high power density of the ABC family ensures
minimal power loss in end-use equipment, thereby facilitating higher
reliability, easier thermal management and meets regulatory
approvals for environmentally-friendly end products.
These power supplies are ideal for telecom, datacom, industrial
equipment and other applications.
Key Features & Benefits
•
4 x 2 x 1.2 Inch Form Factor
•
40 W convection-cooled rating
•
Single to Triple Outputs
•
High Efficiency > 85%
•
Low conducted and radiated noise
•
No Load Power < 0.3 W
•
IEC / EN / UL 62368-1 compliant
•
IEC Protection Class Options:
o Class I: Earth pin J4 (no suffix)
o Class II: No Earth pin (-2 suffix)
•
RoHS Compliant
•
Cover Kit Accessory Available
Applications
•
Lighting
•
Automation Controls
•
Industrial Processing
•
Robotics
•
Applied Computing
•
Wireless Communication
•
Instrumentation
•
Test and Measurement
ABC40 Series
2
1.
MODEL SELECTION
MODEL 1
VOLTAGE
RIPPLE 4
ABC40-1005G
5.1 V
8.0 A
POWER
0.0 A
1%
40 W
ABC40-1012G
12 V
3.5 A
0.0 A
1%
40 W
ABC40-1015G
15 V
2.7 A
0.0 A
1%
40 W
ABC40-1024G
24 V
1.7 A
0.0 A
1%
40 W
ABC40-1048G
48 V
0.83 A
0.0 A
1%
40 W
6.0 A
2.0 A
0.5 A
6.0 A
1.0 A
0.5 A
6.0 A
1.5 A
0.5 A
6.0 A
3.0 A
0.5 A
0.5 A
0.1 A
0.0 A
0.5 A
0.1 A
0.0 A
0.5 A
0.1 A
0.0 A
1.0 A
0.1 A
0.0 A
1.5%
1%
1%
1.5%
1%
1%
1.5%
1%
1%
1.5%
1.5%
1%
ABC40-3000G
ABC40-3001G
ABC40-3002G
ABC40-3003G
COVER-40-XBC 5
V1 = 5.2 V
V2 = 12.5 V
V3 = -12.8 V
V1 = 5.2 V
V2 = 24 V
V3 = -12.8 V
V1 = 5.2 V
V2 = 15 V
V3 = -15 V
V1 = 3.3 V
V2 = 5 V
V3 = -12.8 V
2
MIN LOAD
3
40 W
40 W
40 W
40 W
Metal cover kit accessory
1
Class II version available. Add suffix “-2” at the end of the Model Number
2
Maximum current per output channel. Do not exceed total output power rating.
3
Min Load specified to meet cross regulation.
Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Electrolytic capacitor) in parallel with a 0.1 µF capacitor at rated line
voltage and load ranges.
When used in Cover Kit, de-rate output power to 70 % under all operating conditions.
4
5
2.
MAX LOAD
INPUT SPECIFICATIONS
Specifications are for nominal input voltage, 25°C unless otherwise stated.
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Input Voltage
Universal
90 - 264 VAC
Input Frequency 6
Input Current
No Load Power
Inrush Current
Leakage Current
Switching Frequency
6
47 to 400 Hz
0.85 A max.
0.45 A max.
< 0.3 W
< 0.5 W
30 A max.
60 A max.
< 500 µA
10 ms
8
40 W
Line Regulation
± 0.3%
Load Regulation
V1:
V2 & V3:
Transient Response
50% to 100% load change, 50/60 Hz, 50% duty cycle, 0.1 A/µs
Rise Time
± 0.5%
± 5%
< 10%,
recovery time < 5 ms
< 100 ms
Set Point Tolerance
V1:
V2 & V3:
± 3%
± 5%
Output Voltage Adjustment
V1
± 10%
Over Current Protection
Typical, above rating
130%
Over Voltage Protection
Typical, for V1 only
130%
Short Circuit Protection
Short term, autorecovery
Cooling
Convection
7
8
4.
For ABC40-3003G efficiency is 75% typical
Derate output power linearly to 80% from 90 VAC to 80 VAC input.
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Operating Temperature
Refer to derating curve, Fig. 1
-20 to 0°C start-up is guaranteed
-20 to 70°C
Storage Temperature
-40 to +70°C
Relative Humidity
Non Condensing
95%
Altitude
Operating:
Non-Operating:
10,000 ft.
40,000 ft.
Reliability
MTBF according to Telcordia -SR332-Issue 3
1.87 million hours
Figure 1. Derating Curve
De-rate linearly from 100% at 50°C to 75% at 70°C
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00281_G
ABC40 Series
4
5.
EMC SPECIFICATIONS
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Conducted Emissions
EN 55032-B, CISPR22-B, FCC PART15-B
Pass
Radiated Emissions
EN 55032 B
Pass
Input Current Harmonics
EN 61000-3-2
Class A
Voltage Fluctuation and Flicker
EN 61000-3-3
Pass
ESD Immunity
EN 61000-4-2
Level 3, Criterion A
Radiated Field Immunity
EN 61000-4-3
Level 3, Criterion A
Electrical Fast Transient Immunity
EN 61000-4-4
Level 3, Criterion A
Surge Immunity
EN 61000-4-5
Level 3, Criterion A
Conducted Immunity
EN 61000-4-6
Level 3, Criterion A
Magnetic Field Immunity
EN 61000-4-8
Level 3, Criterion A
Voltage Dips, Interruptions
EN 61000-4-11
Criterion A & B
6.
SAFETY SPECIFICATIONS
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Isolation Voltage
Input to Output
4000 VAC / VDC
Safety Standards
IEC60950-1(ed.2), EN 60950-1, UL60950-1 (2nd Edition), CSA C22.2 No. 60950-1 (2nd Edition),
UL 62368-1, 2nd Ed, 2014-12-01 CAN/CSA C22.2 No. 62368-1-14, (2nd Edition), Class1 SELV
IEC 62368-1:2014, EN 62368-1:2014 ;A11
Agency Approvals
Nemko, UL, C-UL
CE mark
Complies with LVD Directive
7. CONNECTOR & PIN DESCRIPTION
CONNECTOR
PIN
AC Input Connector
J1
DC Output Connector
J2
Signal Connector
J3
Earth (Spade Connector)
J4
8.
DESCRIPTION / CONDITION
Pin 1
Pin 2
Pin 1,2
Pin 3,4
Pin 5
Pin 6
Pin 1
Pin 2
AC Line
AC Neutral
V1
RTN
V3
V2
+V1 Sense
-V1 Sense
MANUFACTURER / PN
Molex: 26-60-4030 or equivalent
Mating: 09-50-3031; Pins: 08-50-0106
Tyco: 640445-6 or equivalent
Mating: 647402-6; Pins: 3-647409-1
Molex: 22-23-2021 or equivalent
Mating: 22-01-2021
Molex: 19705-4301
Mating: 190030001
MECHANICAL SPECIFICATIONS
PARAMETER
DESCRIPTION / CONDITION
Weight
150 g (0.33 lbs.)
Dimensions
101.6 x 50.8 x 30.48 mm (4 x 2 x 1.2 inch)
tech.support@psbel.com
ABC40 Series
5
Figure 2. Mechanical Drawing ABC40-1xxxG
Figure 3. Mechanical Drawing ABC40-3xxxG
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00281_G
ABC40 Series
6
Figure 4. Mechanical Drawing with Cover Kit
NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following:
1
Stand off, used to mount PCB has OD of 5.4 mm max.
2
Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
3
Washer, if used, to have dia of 6.5 mm max.
For more information on these products consult: tech.support@psbel.com
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
tech.support@psbel.com