ABC550-1T58

ABC550-1T58

  • 厂商:

    POWER-ONE

  • 封装:

    -

  • 描述:

    AC/DCCONVERTER58V150/550W

  • 数据手册
  • 价格&库存
ABC550-1T58 数据手册
The ABC550 Series of open frame power supplies feature a wide universal AC input range of 90 – 264 VAC, offering up to 550 W of output power with forced air cooling, or 250 W with conduction cooling in a compact footprint, with a variety of isolated single output voltages. The high efficiency and high power density of the ABC family ensures minimal power loss in end-use equipment, thereby facilitating higher reliability, easier thermal management and meets regulatory approvals for environmentally-friendly end products. These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications. • 5 x 3 x 1.5 Inch Form Factor • Up to 550 Watts with Forced Air Cooling • Efficiencies up to 92% • -40 to 70°C Operating Temperature • 12 V / 0.5 A Fan Output, Thermal Shut-Down Feature • MTBF >3 million hours as per Telcordia SR-332, Issue 3 • RoHS Compliant • CE Marked • Instrumentation • Renewable Energy • Lighting • Test and Measurement • Industrial Applications • Robotics • Applied Computing • Wireless Communication ABC550 Series 2 ABC550-1T12 12 V 9.17 A 16.67 A 41.67 A 500 W ABC550-1T15 15 V 7.33 A 13.33 A 33.33 A 500 W ABC550-1T24 24 V 6.25 A 10.42 A 22.92 A 550 W ABC550-1T30 30 V 5.00 A 8.33 A 18.33 A 550 W ABC550-1T48 48 V 3.13 A 5.21 A 11.46 A 550 W ABC550-1T58 58 V 2.59 A 4.31 A 9.48 A 550 W Specifications are for nominal input voltage, 25°C unless otherwise stated. Input Voltage Universal (Derate from 100% at 115 VAC to 78% at 90 VAC) Input Frequency 90-264 VAC / 390 VDC 47-63 Hz 115 VAC: 230 VAC: 115 VAC: 230 VAC: 115 VAC: 230 VAC: 264 VAC: 115 VAC: 230 VAC: 6 A max. 3 A max. < 0.5 W < 0.7 W 25 A 45 A 75 A < 200 µA < 400 µA Power Factor @ Full Load > 0.95 Switching Frequency PFC Resonant 70 to 130 kHz 68 to 80 kHz Input Current No Load Power Inrush Current Leakage Current Output Power 2 Efficiency (typical @ 230 VAC full load) Hold-up Time (typical) Forced air cooled: Conduction cooled: Convection cooled: 48 V: 24 V: 12 V, 15 V: Full Load Convection Load Conduction Load up to 550 W up to 250 W up to 150 W 92% 91% 90% > 16 ms > 55 ms > 30 ms Line Regulation 4 +/-0.5% Load Regulation 4 +/-1% Minimum Load Transient Response Ripple 3, 4 Output Voltage Adjustment 0.0 A 50-100% step load change, at 0.1A/µs slew rate, 50% duty cycle, 50 Hz = 5% 12 V & 15 V 24 V, 30 V, 48 V & 58 V recovery time < 5 ms 2.0 % max 1.0 % max +/-3% tech.support@psbel.com ABC550 Series Rise Time Set Point 3 Typical 55 ms Tolerance 4 +/-1% Over Current Protection Hiccup mode / Auto recovery > 110% Over Voltage Protection Hiccup mode / Auto recovery 110 to 140% Short Circuit Protection Hiccup mode / Auto recovery Cooling Convection Cooled (refer to Derating Curve) Conduction Cooled (refer to Derating Curve) 400 LFM Forced Air Cooled (refer to Derating Curve) Operating Temperature 5 -40 to 0°C startup guaranteed, with spec deviation 6 Storage Temperature Up to 150 W max Up to 250 W max Up to 550 W max -40 to +70°C -40 to +85°C Relative Humidity Non-condensing 5% to 95% Altitude Operating: Non-operating: 16,000 ft. 40,000 ft. Conducted Emissions EN 55032-B, CISPR22-B, FCC PART15-B Pass Radiated Emissions EN 55032 A; with external core (King core K5B RC 25x12x15-M in input cable) Pass Level B Input Current Harmonics EN 61000-3-2 Class D Voltage Fluctuation and Flicker EN 61000-3-3 Pass ESD Immunity EN 61000-4-2 Level 3, Criterion A Radiated Field Immunity EN 61000-4-3 Level 3, Criterion A Electrical Fast Transient Immunity EN 61000-4-4 Level 3, Criterion A Surge Immunity EN 61000-4-5 Level 3, Criterion A Conducted Immunity EN 61000-4-6 Level 3, Criterion A Magnetic Field Immunity EN 61000-4-8 Level 3, Criterion A Voltage Dips, Interruptions EN 61000-4-11 Criterion A & B Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2020 Bel Power Solutions & Protection BCD.00831_AC Asia-Pacific +86 755 298 85888 ABC550 Series 4 Input to Output: (for ITE applications) 3000 VAC Input to GND: 1500 VAC UL 62368-1 & CAN/CSA C22.2 No. 62368-1:19, UL 60950-1 and CAN/CSA C22.2 No. 60950-1-07 IEC 62368-1:2018, IEC 60950-1(ed.2);am1;am2 EN 62368-1:2014;A11, EN 60950-1:2006;A11;A1;A12;A2 Isolation Voltage Safety Standard(s) Agency Approvals Nemko, UL, C-UL CE mark Complies with LVD Directive AC Input Connector J1 Pin 1 Pin 2 Pin 3 AC Line Not Fitted AC Neutral DC Output Connector (Screw Terminal) J2 Pin 1 Pin 2 V1 +VE V1 -VE Aux (Fan) Output J3 Pin 1 Pin 2 FAN +VE FAN -VE Earth J4 JST : B3P-VH-B(LF)(SN) or equivalent Mating: VHR-3M or equivalent Pins : SVH-41T-P1.1 or equivalent 6-32 inches Screw Pan HD Mating: Designed to accept Ring Tongue Terminal AMP: 8-31886-1, wherein one 16 AWG (max) wire can be crimped. Note: One Ring Tongue Terminal with 16 AWG is recommended for current up to 11 A only. Use multiple tongue terminals with wire for more current. AMP: 640456-2 Mating: 640440-2 Molex: 19705-4301 Mating: 19003-0001 Weight approx. 500 g Dimensions 127 x 76.2 x 38.1 mm (5 x 3 x 1.5 inches) Figure 1. Mechanical Drawing tech.support@psbel.com ABC550 Series 5 De-rate linearly from 100% at 115 VAC to 78% at 90 VAC Convection load: 110 W up to 50 °C De-rate above 50 °C @ 2.5% per °C Conduction load: 200 W up to 50 °C De-rate above 50 °C @ 2.5% per °C Forced air cooled load: 500 W up to 50°C De-rate above 50 °C @ 2.5% per °C Convection load: 150 W up to 50 °C De-rate above 50 °C @ 2.5% per °C Conduction load: 250 W up to 50 °C De-rate above 50 °C @ 2.5% per °C Forced air cooled load: 550 W up to 50°C De-rate above 50 °C @ 2.5% per °C Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2020 Bel Power Solutions & Protection BCD.00831_AC Asia-Pacific +86 755 298 85888 ABC550 Series 6 For reliable and safe operation, please make sure the maximum component temperatures given in table below is not exceeded. TOP PCB BOTTOM PCB INDENT NO DESCRIPTION MAXIMUM TEMP. ALLOWED (°C) 1 Common mode chokes 95 2 Input Bulk Capacitors 90 3 Differential choke 110 4 Boost Choke 110 5 Output Transformer 125 (for 12 V & 15 V) 110 (for 24 V,30 V,48 V,58 V) 6 Output Capacitor 90 7 Bridge Rectifier 120 8 Aluminum Clad PCB 105 9 Output Rectifiers 110 tech.support@psbel.com ABC550 Series 7 FIXING OPTION - 2 FIXING OPTION - 1 Figure 2. Mounting Options Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2020 Bel Power Solutions & Protection BCD.00831_AC Asia-Pacific +86 755 298 85888 8 ABC550 Series Conduction power rating mentioned in the table is with additional aluminum base plate of 3 mm thickness with 177.8 mm (7in) length & 101.6 mm (4in) width. Clearance of minimum 15 mm above the component height is recommended for better thermal management. NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. tech.support@psbel.com
ABC550-1T58 价格&库存

很抱歉,暂时无法提供与“ABC550-1T58”相匹配的价格&库存,您可以联系我们找货

免费人工找货