WLT60
The ABC60 Series of AC-DC open-frame power supplies, with its
wide universal 90-264 VAC input range and high power density, is
available at 60 W of output power and a variety of single and multiple
output voltages.
The high efficiency and high power density of the ABC family ensures
minimal power loss in end-use equipment, thereby facilitating higher
reliability, easier thermal management and meets regulatory
approvals for environmentally-friendly end products.
These power supplies are ideal for telecom, datacom, industrial
equipment and other applications.
•
4 x 2 x 1.2 Inch Form Factor (101.6 x 50.8 x 30.48 mm)
•
50 - 65 W Convection Cooled
•
Single to Triple Outputs
•
High Efficiency > 85%
•
No Load Power < 0.3 W
•
IEC Protection Class Options:
o Class I: Earth pin J4 (no suffix)
o Class II: No Earth pin (-2 suffix)
•
Conducted EMI EN 55022-B, FCC Part 15 Level B
•
IEC / EN / UL 62368-1 Compliant
•
RoHS Compliant
•
Cover Kit Accessory Available
•
Instrumentation
•
Renewable Energy
•
Lighting
•
Test and Measurement
•
Industrial Applications
•
Robotics
•
Applied Computing
•
Wireless Communication
ABC60 Series
2
MODEL 1
VOLTAGE
RIPPLE 4
ABC60-1005G
5.0 V
10.0 A
POWER
0.0 A
1.5%
50 W
ABC60-1012G
12 V
5.42 A
0.0 A
1%
65 W
ABC60-1015G
15 V
4.33 A
0.0 A
1%
65 W
ABC60-1024G
24 V
2.71 A
0.0 A
1%
65 W
ABC60-1048G
48 V
1.35 A
0.0 A
1%
65 W
V1 = 5.2 V
8.0 A
0.5 A
1.5%
V2 = 12.5 V
3.0 A
0.1 A
1%
V3 = -12.8 V
0.5 A
0.0 A
1%
V1 = 5.2 V
8.0 A
0.5 A
1.5%
V2 = 24 V
1.5 A
0.1 A
1%
V3 = -12.8 V
0.5 A
0.0 A
1%
V1 = 5.2 V
8.0 A
0.5 A
1.5%
V2 = 15 V
2.5 A
0.1 A
1%
V3 = -15 V
0.5 A
0.0 A
1%
V1 = 3.3 V
6.0 A
1.0 A
1.5%
V2 = 5 V
3.0 A
0.1 A
1%
V3 = -12.8 V
0.5 A
0.0 A
1%
ABC60-3000G
ABC60-3001G
ABC60-3002G
ABC60-3003G
COVER-60-XBC 5
1
2
3
4
5
MAX LOAD
2
MIN LOAD
3
60 W
60 W
60 W
45 W
Metal cover kit accessory
Class II version available. Add suffix “-2” at the end of the Model Number
Maximum current per output channel. Do not exceed total output power rating.
Min Load specified to meet cross regulation.
Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Electrolytic capacitor) in parallel with a 0.1 µF capacitor at rated line voltage
and load ranges.
When used in Cover Kit, de-rate output power to 70 % under all operating conditions.
Specifications are for nominal input voltage, 25°C unless otherwise stated.
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Input Voltage
Universal
90 - 264 VAC
Input Frequency
6
Input Current
No Load Power
Inrush Current
Leakage Current
Switching Frequency
6
47 to 400 Hz
1.5 A max.
0.75 A max.
< 0.3 W
< 0.5 W
30 A max.
60 A max.
< 500 µA
10 ms
Output Power 8
50 - 65 W
Line Regulation
Output Voltage Adjustment
V1:
V2 & V3:
V1
± 0.3%
± 0.5%
± 5%
< 10%,
recovery time < 5 ms
< 100 ms
± 3%
± 5%
± 10%
Over Current Protection
Typical above rating
130%
Over Voltage Protection
Typical for V1 only
130%
Short Circuit Protection
Short term, autorecovery
Cooling
Convection
Load Regulation
V1:
V2 & V3:
Transient Response
50% to 100% load change, 50/60 Hz, 50% duty cycle, 0.1 A/µs
Rise Time
Set Point Tolerance
7
8
For ABC60-3003G efficiency is 75% typical
Derate output power linearly to 80% from 90 VAC to 80 VAC input.
Single output models deliver 65 W, except for ABC60-1005G (50 W).
Triple output models deliver 60 W, except for ABC60-3003G (45 W).
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Operating Temperature
Refer to derating curve, Fig. 1
-20 to 0°C start-up is guaranteed
-20 to 70°C
Storage Temperature
-40 to +85°C
Relative Humidity
Non Condensing
95%
Altitude
Operating:
Non-Operating:
10,000 ft.
40,000 ft.
Reliability
MTBF according to Telcordia -SR332-Issue 3
1.87 million hours
Cooling
Convection
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00282_G
ABC60 Series
4
Figure 1. Derating Curve
De-rate linearly from 100% at 50°C to 50% at 70°C
Figure 2. Derating Curve with Cover Kit
Conducted Emissions
EN 55032-B, CISPR22-B, FCC PART15-B
Pass
Radiated Emissions
EN 55032 B
Pass
Input Current Harmonics
EN 61000-3-2
Class A
Voltage Fluctuation and Flicker
EN 61000-3-3
Pass
ESD Immunity
EN 61000-4-2
Level 3, Criterion A
Radiated Field Immunity
EN 61000-4-3
Level 3, Criterion A
Electrical Fast Transient Immunity
EN 61000-4-4
Level 3, Criterion A
Surge Immunity
EN 61000-4-5
Level 3, Criterion A
Conducted Immunity
EN 61000-4-6
Level 3, Criterion A
Magnetic Field Immunity
EN 61000-4-8
Level 3, Criterion A
Voltage Dips, Interruptions
EN 61000-4-11
Criterion A & B
tech.support@psbel.com
ABC60 Series
5
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Isolation Voltage
Input to Output:
4000 VAC/VDC
Safety Standards
IEC 60950-1(ed.2), EN 60950-1, UL 60950-1 (2nd Edition), CSA C22.2 No. 60950-1 (2nd Edition),
UL 62368-1, 2nd Ed, 2014-12-01 CAN/CSA C22.2 No. 62368-1-14, 2nd Ed, Class 1 SELV
IEC 62368-1:2014, EN 62368-1:2014; A11
Agency Approvals
Nemko, UL, C-UL
CE mark
Complies with LVD Directive
CONNECTOR
PIN
AC Input Connector
J1
DC Output Connector
J2
Signal Connector
J3
Earth (Spade Connector)
J4
DESCRIPTION / CONDITION
Pin 1
Pin 2
Pin 1,2
Pin 3,4
Pin 5
Pin 6
Pin 1
Pin 2
AC Line
AC Neutral
V1
RTN
V3
V2
+V1 Sense
-V1 Sense
MANUFACTURER / PN
Molex: 26-60-4030 or equivalent
Mating: 09-50-3031; Pins: 08-50-0106
Tyco: 640445-6 or equivalent
Mating: 647402-6; Pins: 3-647409-1
Molex: 22-23-2021 or equivalent
Mating: 22-01-2021
Molex: 19705-4301
Mating: 190030001
PARAMETER
DESCRIPTION / CONDITION
Weight
150 g (0.33 lbs.)
Dimensions
101.6 x 50.8 x 30.48 mm (4 x 2 x 1.2 inch)
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00282_G
ABC60 Series
6
L
N
Figure 3. Mechanical Drawing ABC60-1xxxG
1
L
N
Figure 4. Mechanical Drawing ABC60-3xxxG
tech.support@psbel.com
ABC60 Series
7
Figure 5. Mechanical Drawing wit Cover Kit
NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following:
1
Stand off, used to mount PCB has OD of 5.4 mm max.
2
Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
3
Washer, if used, to have dia of 6.5 mm max.
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection