BM1501-9R

BM1501-9R

  • 厂商:

    POWER-ONE

  • 封装:

    -

  • 描述:

    DC/DCCONVERTER15V3.4A

  • 数据手册
  • 价格&库存
BM1501-9R 数据手册
M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Features • Extremly wide operating input voltage ranges from 8 to 385 VDC and 85 to 264 VAC, 47 to 440 Hz • RoHS lead-free-solder and lead-solder-exempted products available • 5 year warranty for RoHS compliant products with an extended temperature range • Class I equipment • Input over- and undervoltage lockout • 1, 2, or 3 individually isolated outputs up to 72 V • Outputs: SELV, no load, overload, short-circuit proof, rectangular current limiting characteristic • Adjustable output voltages with remote on/off • Immunity according to IEC/EN 61000-4-2, -3, -4, -5, -6 • Emissions according to EN 55011/55022 • According to EN 45545 and NF-F-16 (Version V107 or later) 111 4.37" 3U 39 1.54" 8 TE • All PCBs boards coated by protective lacquer • Very high reliability 168 6.6" • Battery charger models available Safety-approved to the latest edition of IEC/EN 60950-1 and UL/CSA 60950-1 Description The M Series of DC-DC and AC-DC converters represents a broad and flexible range of power supplies for use in advanced industrial electronic systems. Features include high efficiency, reliability, low output voltage noise and excellent dynamic response to load/line changes due to individual regulation of each output. The converter inputs are protected against surges and transients occurring at the source lines. An input over- and undervoltage lockout circuit disables the outputs, if the input voltage is outside the specified range. An inrush current limitation prevents circuit breakers and fuses from tripping at switch-on. All outputs are open- and short-circuit proof, and are protected against overvoltages by means of built-in suppressor diodes. The outputs can be inhibited by a logic signal applied to the connector (pin 2). If the inhibit function is not used, pin 2 should be connected to pin 23 to enable the outputs. LED indicators display the status of the converter and allow visual monitoring of the system at any time. Table of Contents Full input to output, input to case, output to case, and output to output isolation is provided. The case design allows operation at nominal load up to 71 °C in a free-air ambient temperature. If forced cooling is provided, the ambient temperature may exceed 71 °C but the case temperature should remain below 95 °C under all conditions. A temperature sensor generates an inhibit signal, which disables the outputs, when the case temperature TC exceeds the limit. The outputs automatically recover, when the temperature drops below the limit. Various options are available to adapt the converters to individual applications. The converters may either be plugged into a 19" rack system according to IEC 60927-3 or be mounted onto a chassis or a plate. Page Description ............................................................................. 1 Model Selection ..................................................................... 2 Functional Description ........................................................... 5 Electrical Input Data ............................................................... 6 Electrical Output Data ............................................................ 8 Auxiliary Functions ............................................................... 11 Page Electromagnetic Compatibility (EMC) .................................. 14 Immunity to Environmental Conditions ................................ 16 Mechanical Data .................................................................. 17 Safety and Installation Instructions ...................................... 18 Description of Options ......................................................... 20 Accessories .......................................................................... 26 Copyright © 2018, Bel Power Solutions Inc. All rights reserved. BCD20018-G Rev AE1, 16-Apr-2018 MELCHER The Power Partners. Page 1 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Model Selection Non-standard input / output configurations or special custom adaptions are available on request. Table 1 provides an overview of the basic input and output configurations. More than 1000 different model types have been manufactured with different input /output configurations and customized specialties. Please consult the company for additional model types! Table 1a: Standard models AM, BM, FM Output 1 Output 2 Output 3 Vo nom Io nom [VDC] [A] Vo nom Io nom [VDC] [A] V nom Io nom [VDC] [A] Operating input voltage range and efficiency Options Vi min – Vi max 8 – 35 VDC η min1 [%] Vi min – Vi max 14 – 70 VDC η min1 [%] Vi min – Vi max 20 – 100 VDC η min1 [%] 5.1 12 15 24 48 8.0 4.0 3.4 2.0 1.0 - - - - AM1001-9RG AM1301-9RG AM1501-9RG AM1601-9RG AM1901-9RG 72 79 79 81 81 BM1001-9RG BM1301-9RG BM1501-9RG BM1601-9RG BM1901-9RG 74 80 81 83 83 FM1001-9RG FM1301-9RG FM1501-9RG FM1601-9RG FM1901-9RG 74 80 81 82 83 -7, P D0 – D9, V0 – V3 3 F, A, K, H non-G 5.1 5.1 12 15 24 4.0 4.0 2.0 1.7 1.0 5.1 24 12 15 24 4.0 1.0 2.0 1.7 1.0 - - AM2001-9G AM2060-9G AM2320-9G AM2540-9G AM2660-9G 77 78 - BM2001-9G BM2060-9G BM2320-9G BM2540-9G BM2660-9G 79 80 - FM2320-9G FM2540-9G -- 80 79 -7, P D0 – D9 A, K, H non-G 5.1 5.1 5.1 5.0 5.0 5.0 12 15 24 0.7 0.6 0.35 12 15 24 0.7 0.6 0.35 AM3020-9G AM3040-9G AM3060-9G 75 75 - BM3020-9G BM3040-9G BM3060-9G 76 76 - FM3020-9G FM3040-9G - 76 76 - -7, P D0 – D9, A K, H, non-G Table 1b: Standard models CM, DM, LM Output 1 Vo nom Io nom [VDC] [A] Output 2 Output 3 Vo nom Io nom [VDC] [A] V nom Io nom [VDC] [A] Operating input voltage range and efficiency Vi min – Vi max 28 – 140 VDC η min1 [%] Vi min – Vi max 44 – 220 VDC η min1 [%] Vi min – Vi max 88 – 372 VDC 85 – 264 VAC 2 η min1 [%] 74 81 82 LM1001-9RG LM1301-9RG LM1501-9RG LM1601-9RG LM1901-9RG 74 80 79 82 82 -7, E 4, P D0 – D9 V0 – V3 3 A, K, H non-G LM2001-9G LM2060-9G LM2320-9G LM2540-9G LM2660-9G 80 79 -7, E 4, P D0 – D9 A, K, H non-G LM3020-9G LM3040-9G LM3060-9G 74 73 - -7, E 4, P D0 – D9, A K, H, non-G 5.1 12 15 24 48 8.0 4.0 3.4 2.0 1.0 - - - - CM1001-9RG CM1301-9RG CM1501-9RG CM1601-9RG CM1901-9RG 74 80 82 82 82 DM1001-9RG DM1301-9RG DM1501-9RG DM1601-9RG DM1901-9R 5.1 5.1 12 15 24 4.0 4.0 2.0 1.7 1.0 5.1 24 12 15 24 4.0 1.0 2.0 1.7 1.0 - - CM2001-9G CM2060-9G CM2320-9G CM2540-9G CM2660-9G 79 80 - DM2001-9G DM2060-9G DM2320-9G DM2540-9G DM2660-9G 5.1 5.1 5.1 5.0 5.0 5.0 12 15 24 0.7 0.6 0.35 12 15 24 0.7 0.6 0.35 CM3020-9G CM3040-9G CM3060-9G 76 76 76 DM3020-9G DM3040-9G DM3060-9G 1 2 3 4 Options 83 80 80 77 76 76 Min. efficiency at Vi nom and I o nom. Typ. values are approx. 2% better. Operating frequency range: 47 – 440 Hz; see Safety and Installation Instructions for > 60 Hz ! Option V0, V2, V3 available only for output 1 = 5.1 V (excludes option D) Option E only available for CM and LM models (not for DM) NFND: Not for new designs. BCD20018-G Rev AE1, 16-Apr-2018 Preferred for new designs MELCHER The Power Partners. Page 2 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Table 1c: EM and battery charger models Output 1 3 4 Output 2 Vo Bat Io nom [VDC] [A] Vo safe [VDC] Vo max [VDC] Same Vo nom and I o nom as DM models - - 12.84 25.68 38.52 51.36 64.2 14.15 – 14.6 28.3 – 29.15 42.45 – 43.72 56.6 – 58.3 70.75 – 72.87 12 24 36 48 60 1 2 3 4 3.6 1.8 1.2 0.9 0.72 Vo nom [VDC] Output 3 Io nom [A] Vo nom [VDC] Operating input voltage range and efficiency Io nom [A] Vi min – Vi max η min 67 – 385 VDC [%] EM1xxx-9RG same as DM models EM2xxx-9RG same as DM models same as DM models EM3xxx-9RG - - - - - 1 Vi min – Vi max η min 88 – 372 VDC [%] 85 – 264 VAC 2 Options 1 - - - -7, E, D, A non-G - LM1781-9RD5G LM1782-9RD5G LM1783-9RD5G LM1784-9RD5G LM1785-9RD5G 79 81 82 81 81 -7, E, A non-G Min. efficiency at Vi nom and I o nom. Typ. values are approx. 2% better. Operating frequency range: 47 – 440 Hz; see Safety and Installation Instructions for > 60 Hz V o nom for EM models Setting voltage with open R-input (battery chargers) NFND: Not for new designs. BCD20018-G Rev AE1, 16-Apr-2018 Preferred for new designs MELCHER The Power Partners. Page 3 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Part Number Description C M 2 5 40 -9 E P D3 A H G Operating input range Vi : 8 – 35 VDC 14 – 70 VDC 20 – 100 VDC 28 – 140 VDC 44 – 220 VDC 67 – 385 VDC 85 – 264 VAC, 88 – 372 VDC ................... A ................... B ................... F ................... C ................... D ................... E ................... L Series ................................................................................... M Number of outputs 4 ......................................................................... 1, 2, 3 4 Output 1, Vo1 nom : 5.1 V 12 V 15 V 24 V other voltages 48 V ............ 0, 1, 2 .................... 3 ................ 4, 5 .................... 6 ................ 7, 8 .................... 9 Single-output models (different specs.) ...................... 01 – 99 5.1 V ....................... 01 – 19 Outputs 2, 3: Vo2 nom, Vo3 nom: 12 V ........................ 20 – 39 15 V ........................ 40 – 59 24 V ........................ 60 – 69 other voltages and specs. ............ 21 – 99 Ambient temperature range TA: –25 to 71 °C .................. -7 – 40 to 71 °C .................. -9 customer-specific ... -0, -5, -6, -8 Auxiliary functions and options: Inrush current limitation (CM, EM, LM) ........................ E Output voltage control input (single-output models) .... R 2 Potentiometers for adjustment of output voltages ....... P 2 Save data signal (D0 – D9, to be specified) ................ D 1 ACFAIL signal (V0, V2, V3, to be specified) ................ V 1 Output voltage test sockets .......................................... A Increased electric strength test voltage ....................... H Input fuse built-in (not accessible) ............................... F 3 Coding strip at the connector ....................................... K RoHS-compliant for all 6 substances ........................... G 1 2 3 4 Option D excludes option V and vice versa Feature R is fitted to single-output models only. Option P excludes option R (and vice versa). Only for FM1000 Models with 220 mm case length. Just add 6000 to the standard model number, e.g., DM3020-9AG → DM9020-9AG. Note: The sequence of options must follow the order above. This part number description is descriptive only; it is not inteded for creating part numbers. NFND: Not for new designs Preferred for new designs. Example: CM2540-9EPD3AHG: DC-DC converter, operating input voltage range 28 – 140 VDC, providing output 1 with 15 V/1.7 A and output 2 with 15 V /1.7 A; temperature range –40 to +71 °C, inrush current limitation, equipped with potentiometers, undervoltage monitor D3, test sockets, tested with higher voltage output to case, RoHS-compliant for all 6 substances. BCD20018-G Rev AE1, 16-Apr-2018 MELCHER The Power Partners. Page 4 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Functional Description The input voltage is fed via an input fuse, an input filter, a bridge rectifier, and an inrush current limiter to the input capacitor. This capacitor sources a single-transistor forward converter. Each output is powered by a separate secondary winding of the main transformer. The resultant voltages are rectified and their ripple smoothed by a power choke and an output filter. The main control circuit senses the main output voltage Vo1 and generates, with respect to the maximum admissible output currents, the control signal for the primary switching transistor. This signal is transferred to the primary side by a coupling transformer. The auxiliary output voltages Vo2 and Vo3 are individually regulated by means of secondary switching transistors. Each auxiliary output's current is sensed using a current transformer. If one of the outputs is driven into current limit, the other outputs will reduce their output voltages as well, because all output currents are controlled by the same main control circuit. 03009a Option P Main control circuit CY 5 Vi+ 29 L 5 Vi– Input filter Fuse 1 2 3 32 Forward converter approx. 70 kHz N Output 1 filter 2 i 5 D, V 14 R4 17 G4 20 23 CZ Control circuit output 2 14 Output 2 filter 17 CZ 5 Control circuit output 3 Output 3 filter 8 11 26 CY 1 2 3 4 5 Transient suppressor diode in AM, BM, CM, FM models. Bridge rectifier in LM, series diode in EM models. Inrush current limiter (NTC) in CM, DM, EM, LM models (option E: refer to the description of option E). Single-output models with feature R. LM-models Fig. 1 Block diagram, triple-output models BCD20018-G Rev AE1, 16-Apr-2018 MELCHER The Power Partners. Page 5 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Electrical Input Data General conditions: – TA = 25 °C, unless TC is specified. – Connector pins 2 and 23 interconnected, R input not connected; with option P: Vo = Vo nom Table 2a: Input data Input AM Characteristics Vi Conditions min typ max min 35 14 FM typ max min 70 20 CM typ max min max 154 7 Vi nom Ii Input current Pi 0 No-load input power: V i nom – single-output models I o1,2,3 = 0 – double-output models – triple-output models 1 7 6 1.5 9 9 1 7 6 1.5 9 9 1 7 6 1.5 9 9 1 7 6 1.5 9 9 Idle input power inhibited, Vi nom 1 1.5 1 1.5 1 1.5 1 1.5 Peak inrush current Vi = Vi max RS = 0 Ω 3 TC = 25 °C Iinr p 6 tinr r Rise time tinr h Time to half-value Ri Input resistance Ci Input capacitance V i abs Input voltage limits without any damage Vi nom, Io nom 2 TC = 25 °C 100 typ Unit Operating input voltage Io = 0 – Io nom TC min – TC max Nominal input voltage Pi inh 8 BM 28 15 30 50 60 4.0 2.0 1.2 1.0 400 500 60 50 40 60 170 100 60 280 87.5 140 A W 170 4 400 A µs 824 4 250 VDC mΩ 2600 4000 670 1100 370 600 370 600 µF 0 40 0 80 0 120 0 160 VDC Table 2b: Input data Input DM Characteristics Conditions Vi Io = 0 – Io nom TC min – TC max Operating input voltage min typ EM max min 44 Vi nom Nominal input voltage Vi nom, Io nom 2 typ LM max 220 67 min typ 85 385 88 110 220 310 0.55 0.275 0.20 Unit max 264 VAC 1 372 VDC Ii Input current Pi 0 No-load input power: Vi nom – single-output models Io1,2,3 = 0 – double-output models – triple-output models 1 7 6 1.5 9 9 1 7 6 1.5 9 9 1 7 6 1.5 9 9 Idle input power 1 1.5 1 1.5 1 1.5 Pi inh Iinr p 6 Peak inrush current t inr r Rise time t inr h Time to half-value Ri Input resistance Ci Input capacitance Vi abs 1 2 3 4 5 6 7 inhibited, Vi nom 110 4 Vi = Vi max RS = 0 Ω 3 TC = 25 °C TC = 25 °C Input voltage limits without any damage 160 4 40 40 300 240 900 2400 4 W 60 4 250 2000 4 A A µs 6200 4 140 270 140 270 140 0 400 5 – 400 400 – – – – mΩ 270 µF – 400 400 VDC 0 284 VAC In AC powered mode (LM models): Nominal input voltage range: 100 – 240 VAC, operating input frequency range: 47 – 440 Hz With multiple-output models, the same condition for each output applies. RS = source resistance. Value for initial switch-on cycle. 1 s max., duty cycle 1% max. I inr p = V i / (Rs + Ri); see Inrush Current. 140 V continuously. CM models with version V106 or greater (or with suffix /131) withstand 154 V for 2 s. BCD20018-G Rev AE1, 16-Apr-2018 MELCHER The Power Partners. Page 6 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Input Fuse Input Under-/Overvoltage Lockout A fuse holder containing a slow-blow type fuse (size: 5 × 20 mm) is mounted in the back plate of the converter. The fuse protects the converter against severe defects. It may not fully protect it at input voltages exceeding 200 VDC. In applications, where the converters operate at DC source voltages above 200 VDC, an external fuse or a circuit breaker at system level should be installed. If the input voltage remains below 0.8 Vi min or exceeds approx. 1.1 Vi max, an internally generated inhibit signal disables the output(s). When checking this function the absolute maximum input voltage rating Vi abs must be carefully considered (see table Input data). The fuse and a VDR form together with the input filter an effective protection against high input transients. Note: For applications, where the fuse should not be accessible; see Option F. Table 3: Fuse types (slow-blow) Series Schurter type Part number AM1000 – 3000 SPT 10 A /250 V 0001.2514 BM1000 – 3000 SPT 8 A /250 V 0001.2513 FM1000 – 3000 SPT 5 A /250 V 0001.2511 CM1000 – 3000 SPT 3.15 A /250 V 0001.2509 DM1000 – 3000 EM1000 – 3000 LM1000 – 3000 SPT 2.5 A /250 V 0001.2508 Note: When Vi is between Vi min and the undervoltage lockout level, the output voltage may be below the value defined in table Output data. Reverse Polarity Reverse polarity at the input of AM, BM, CM, DM, and FM models will cause the fuse to blow. In EM and LM models a series diode will protect the converter. A series diode is not incorporated in AM, BM, CM, DM and FM types to avoid unwanted power losses. Inrush Current The CM, DM, EM, and LM (excluding FM) models incorporate an NTC resistor in the input line, which (during the initial switchon cycle) limits the peak inrush current in order to prevent the connectors and external switching devices from damage. Subsequent switch-on cycles within a short interval will cause an increase of the peak inrush current due to the warming-up of the NTC resistor. Refer to Option E (only available for CM, EM, and LM. Ii [A] 04014a 10 Ii [A] 04015a LM A-EM AM 80 400 70 350 60 300 50 250 40 200 BM AM BM 1.0 FM CM FM LM DM EM LM 0.1 1 2 3 4 5 6 Vi DC ________ Vi min DC 30 150 20 100 10 50 EM DM CM t [ms] 0 Fig. 2 Typical input current versus relative input voltage at nominal output load 0 0.2 0.5 0.4 1.0 0.6 1.5 0.8 2.0 1.0 2.5 1.2 3.0 1.4 3.5 1.6 A-EM 4.0 LM Fig. 3 Typical inrush current at initial switch-on. Vi max (DC) and nominal output load BCD20018-G Rev AE1, 16-Apr-2018 MELCHER The Power Partners. Page 7 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Electrical Output Data General conditions – TA = 25°C, unless TC is specified. – Connector pins 2 and 23 interconnected, R input not connected; with option P: Vo = Vo nom Table 4: Output data Output Vo nom 5.1 V 12 V 15 V 24 V Characteristics Conditions min typ max min typ max min typ max Vo Output voltage Vi nom, I o nom 1 5.07 Vo p Output overvoltage protection 5 Io nom Output current Io L Output current limitation vo Output voltage noise 5.13 11.93 7.5 Vi min – Vi max TC min – TC max Switch. freq. V i nom, I o nom 1 IEC/EN 61204 Total BW = 20 MHz 30 25 50 35 70 40 80 120 40 80 40 80 40 80 Static load regulation Vi nom Io nom – 0 2 6 Vi nom Io nom – 0 3 0 td c α Vo 1 2 3 4 5 48.28 V 85 60 ∆Vo I vo d c 41 15 Vi min – Vi nom Vi nom – Vi max Io nom 1 td 25 min typ max 24.14 47.72 see table 1 Model Selection Static line regulation vo d 21 min typ max 15.09 23.86 Unit see fig. 4 Typical voltage Vo1 versus output currents Io ∆Vo V ∆Vo Ic Static cross load regulation 4 12.07 14.91 48 V ±10 ±30 50 100 mVpp - ±12 ±50 ±15 ±60 ±15 ±60 ±15 ±60 25 13 50 17 60 30 80 60 150 ±15 0 ±20 0 ±30 0 ±40 mV - Dynamic Voltage V i nom load deviation Io nom ↔ 1/3 Io nom 2 regulation Recovery IEC/EN 61204 time ±220 ±110 ±150 ±130 ±150 0.6 0.6 0.5 1 2 ms Dynamic Voltage Vi nom cross load deviation Io nom ↔ 1/3 Io nom 3 regulation 4 Recovery IEC/EN 61204 time +10 –100 +10 –75 +10 –140 +20 –200 - mV 0.05 0.5 0.2 0.3 0.5 0.7 1 2 - ms Temperature coefficient ∆Vo /∆TC ±0.02 ±0.02 ±0.02 ±0.02 ±0.02 %/K ±1.0 ±2.4 ±3.0 ±4.8 ±9.6 mV/K Vi min – Vi max 0 – I o nom With multiple-output models, all outputs are loaded with the nominal current. Condition for specified output. With multiple-output models, other output(s) loaded with constant current Io nom. See fig. 5 Dynamic load regulation. Condition for non-specified output, individually tested, other output(s) loaded with constant current Io nom. See fig. 5 Dynamic load regulation. Multiple-output models. By suppressor diode. BCD20018-G Rev AE1, 16-Apr-2018 MELCHER The Power Partners. Page 8 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Output Characteristic and Protection Each output is protected by a suppressor diode, which under worst case conditions may become a short circuit. The suppressor diodes are not designed to withstand externally applied overvoltages. Overload at any of the outputs will cause a shutdown of all outputs. A red LED indicates an overload condition at the respective output. Io nom IoL1 IoL2, IoL3 1.0 0.95 Notes: Sufficient forced cooling or an additional heat sink allow TA to pass over 71 °C, if TC max is not exceeded. A temperature sensor generates an internal inhibit signal disabling the outputs, when the case temperature exceeds TC max. The outputs automatically recover, when the temperature drops below this limit. Io1 Io2,Io3 0.5 Caution: The installer must ensure that under all operating conditions TC remains within the limits stated in the table Temperature specifications. For -7 or -9 models at an ambient temperature TA of 85 °C with only convection cooling, the maximum permissible current for each output is approx. 50% of its nominal value; see figure 6. Vo Vo nom temperature of surrounding components and surfaces. TA max is therefore, contrary to TC max, an indicative value only. Io /Io nom Forced cooling 1.0 0.5 05022a 1.0 1.2 05031a 0 0.8 Io Io nom Convection cooling 0.6 TC max 0.4 Fig. 4 Typical voltage Vo versus output currents Io. 0.2 Vo 0 ∆Vo I Vod ∆Vo I 50 60 70 80 90 100 TA [°C] Fig. 6 td Vod Output current derating versus temperature td t Io/Io nom 1 0.3 0 ≥10 µs ≥10 µs 05010a t Main outputs of equal nominal voltage can be connected in parallel. It is important to assure that the main output of a multiple-output converter is forced to supply a minimum current of 0.1 A to enable correct operation of its own auxiliary outputs. In parallel operation, one or more of the main outputs may operate continuously in current limitation, causing an increase of the case temperature TC. Consequently, a reduction of the max. ambient temperature by 10 K is recommended. Fig. 5 Dynamic load regulation Vo d versus load change. Thermal Considerations and Protection If a converter is located in free, quasi-stationary air (convection cooling) at the indicated maximum ambient temperature TA max (see table Temperature specifications) and is operated at its nominal input voltage and output power, the temperature measured at the measuring point of case temperature TC (see Mechanical Data) will approach the indicated value TC max after the warm-up phase. However, the relationship between TA and TC depends heavily on the conditions of operation and integration into a system. The thermal conditions are influenced by input voltage, output current, airflow, and BCD20018-G Rev AE1, 16-Apr-2018 Parallel and Series Connection Main or auxiliary outputs can be connected in series with any other output of the same or another converter. In series connection, the maximum output current is limited by the lowest current limit. Output ripple and regulation values are added. Connection wiring should be kept as short as possible. If output terminals are connected together in order to establish multi-voltage configurations, e.g., +5.1 V, ±12 V etc., the common-ground connecting point should be as close as possible to the connectors of the converter in order to avoid excessive output ripple voltages. Note: Auxiliary outputs should never be connected in parallel! MELCHER The Power Partners. Page 9 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Output Current Allocation for Special Models Output currents differing from those given for standard models (see Model Selection) can be provided on request. A maximum output power of 50 W should be considered, if an ambient temperature range of – 40 to 71 °C is required. The maximum permissible output currents are indicated in the table below. If the output voltages are different from standard values, the relevant output currents have to be adapted accordingly. With reduced maximum ambient temperature or with forced cooling, the total output power may exceed 50 W. Customized configurations always need to be checked by a feasibility study first. Please ask the Company for more information. Table 5: Current allocation with special models Output voltage all types Vo1/2/3 nom [V] Output 1 all types I o1 max [A] Output 2 AM – LM2000 I o2 max [A] Output 2 AM – LM3000 I o2 max [A] Output 3 AM – LM3000 I o3 max [A] TA [°C ] TC [°C ] 5.1 12 15 24 8.0 4.0 3.4 2.0 4.0 2.0 1.7 1.0 1.8 (2.5 1) 1.5 1.2 0.7 1.5 1.2 1.0 0.5 – 40 to 71 –25 to 95 5.1 12 15 24 10.0 5.0 4.0 2.5 4.5 2.5 2.0 1.3 2.1 (2.8 1) 1.7 1.5 0.9 1.8 1.5 1.3 0.7 –25 to 60 –25 to 90 5.1 12 15 24 11.0 6.0 4.6 3.0 5.0 3.0 2.3 1.5 2.4 (3.0 1) 2.0 1.7 1.0 2.0 1.7 1.5 0.8 –25 to 50 –25 to 85 2 1 Special high-current components required. 2 Temperature Vi min has to be increased. Hold-up Time and Output Response When the input voltage is switched off, the output voltage will remain high for a certain hold-up time t h (see fig. 7) before the output voltage falls below 0.95 Vo nom. To achieve the hold-up times indicated in fig. 8, AM, BM, CM, DM, and FM models require an external series diode in the input line. This is necessary to prevent the discharge of the input capacitor through the source impedance or other circuits connected to the same source. EM and LM models have a built-in series diode. In AM, BM, CM, DM, and FM models, no series diode is built-in, since it would generate additional power losses inside the converter. Note: For hold-up time with option V, refer to Option V. The behavior of the outputs is similar with either the input voltage applied or the inhibit switched low. No output voltage overshoot occurs, when the converter is turned on or off. th [ms] 05024a 1000 LM EM 100 CM/DM AM/BM/FM Vo/Vo nom 05025a 0.95 10 0.1 0 tr Vi tf t th 1 0 1 t Inhibit 1 0 t 0.1 1 2 3 4 5 Vi DC ______ Vi min DC 6 Fig. 7 Fig. 8 Output response times versus Vi or inhibit control Typical hold-up time t h versus input voltage at Io nom BCD20018-G Rev AE1, 16-Apr-2018 MELCHER The Power Partners. Page 10 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Table 6: Output response time t r and t f (see fig. 7). Values not applicable for models equipped with option E. Type of converter tr at Po = 0 and t f at Po = Po nom typ max t r and t f at Po = 3/4 Po nom typ max t r at Po = Po nom typ max Unit ms AM – LM1001-9R AM – LM1301-9R AM – LM1501-9R AM – LM1601-9R AM – LM1901-9R 5 10 5 15 65 10 20 10 30 130 5 15 10 25 100 10 30 20 50 200 10 20 30 40 165 20 40 60 80 330 AM – LM2320-9 AM – LM2540-9 20 15 40 30 30 20 60 40 50 35 100 70 AM – LM3020-9 AM – LM3040-9 55 40 110 80 85 60 170 120 145 100 290 200 Conditions: R input not connected. For multiple-output models the figures indicated in the table relate to the output, which reacts slowest. All outputs are resistively loaded. Variation of the input voltage within Vi min – Vi max does not influence the values considerably. Auxiliary Functions Inhibit Iinh [mA] The outputs of the converters may be enabled or disabled by means of a logic signal (TTL, CMOS, etc.) applied between the inhibit input i and the negative pin of output 1 (Vo1–). In systems with several converters, this feature can be used, for example, to control the activation sequence of the converters. If the inhibit function is not required, connect the inhibit pin 2 to pin 23 to enable the outputs (active low logic, fail safe). The response times are specified in table 6. 2.0 Vinh = 2.4 V Vinh = 0.8 V 06032a 1.6 1.2 0.8 0.4 Vo = on Vo = off 0 –0.4 06031a Vi+ Vo+ i –0.8 –50 –10 0 10 30 50 Vinh [V] Iinh Vinh Vi– –30 Fig. 10 Typical inhibit current I inh versus inhibit voltage Vinh Vo– Fig. 9 Definition of Vinh and Iinh. Table 7: Inhibit data Characteristics Vinh Inhibit input voltage to keep output voltage I inh Inhibit current BCD20018-G Rev AE1, 16-Apr-2018 Vo = on Vo = off Conditions min V i min – V i max TC min – TC max –50 Vinh = 0 – 60 MELCHER The Power Partners. typ 2.4 max Unit 0.8 V 50 –100 –220 µA Page 11 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters R-Control for Output Voltage Adjustment As a standard feature, single-output models without option P offer an adjustable output voltage identified by letter R in the type designation. Note: With open R input, Vo = Vo nom. The output voltage Vo can either be adjusted by an external voltage (Vext) or by an external resistor (Rext1 or Rext2). The adjustment range is approximative 0 – 110% of Vo nom. For output voltages Vo > Vo nom, the minimum input voltage Vi min specified in Electrical Input Data increases proportionally to Vo/Vo nom. JM075 L Rext 2 4 kΩ R + Control logic + Vext Rext1 (Vo – 2.5 V) Rext2 ≈ 4 kΩ • –––––––––––––––––– 2.5 V • (Vo/Vo nom – 1) Caution: To prevent damage, Rext2 should never be less than 47 kΩ. b) Adjustment by means of an external control voltage Vext between G and R pin. The control voltage range is 0 to 2.75 V and allows for adjustment in the range of Vo ≈ 0 to 110% of Vo nom. – G N or: Between the R pin and Vo+ to achieve an output voltage range of Vo ≈ 100 to 110% of Vo nom. Note: R inputs of n converters with paralleled outputs may be paralleled too, but if only one external resistor is used, its value should be Rext1/n or Rext2 / n respectively. Vo+ Vref = 2.5 V a) Adjustment by means of an external resistor Rext. Depending upon the value of the required output voltage, the resistor shall be connected: either: Between the R and G pin to achieve an output voltage adjustment range of Vo ≈ 0 to 100 % of Vo nom. Vo Rext1 ≈ 4 kΩ • ––––––––– Vo nom – Vo Vo • 2.5 V Vext ≈ –––––––– Vo nom Vo– Caution: The external control voltage should be in the range 0 to +3 V to prevent the converter from damage. Fig. 11 Output voltage adjustment Table 8a: Rext1 for Vo < Vo nom (conditions: Vi nom, Io nom, rounded up to resistor values E 96, Rext2 is not fitted.) Vo nom = 5.1 V Vo [V] Rext1 [kΩ] 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 0.432 0.976 1.65 2.61 3.83 5.76 8.66 14.7 30.1 200.0 Vo nom = 12 V Vo [V] Rext1 [kΩ] Vo nom = 15 V Vo [V] Rext1 [kΩ] Vo nom = 24 V Vo [V] Rext1 [kΩ] Vo nom = 48 V Vo [V] Rext1 [kΩ] 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 2.0 4.0 6.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 8.0 12.0 16.0 20.0 24.0 28.0 32.0 36.0 40.0 44.0 0.806 1.33 2.0 2.87 4.02 5.62 8.06 12.1 20.0 44.2 0.619 1.47 2.67 4.53 6.04 8.06 11.0 16.2 26.1 56.2 0.806 1.33 2.0 2.87 4.02 5.62 8.06 12.1 20.0 44.2 0.806 1.33 2.0 2.87 4.02 5.62 8.06 12.1 20.0 44.2 Table 8b: R2 for Vo > Vo nom (conditions: Vi nom, Io nom, rounded up to resistor values E 96, Rext1 is not fitted.) Vo nom = 5.1 V Vo [V] Rext2 [kΩ] 5.15 5.20 5.25 5.30 5.35 5.40 5.45 5.50 464 215 147 110 90.9 78.7 68.1 61.9 Vo nom = 12 V Vo [V] Rext2 [kΩ] 12.1 12.2 12.3 12.4 12.5 12.6 12.7 12.8 13.0 13.2 BCD20018-G Rev AE1, 16-Apr-2018 1780 909 619 464 383 316 274 249 200 169 Vo nom = 15 V Vo [V] Rext2 [kΩ] 15.2 15.4 15.6 15.8 16.0 16.2 16.4 16.5 1470 750 511 383 332 274 237 226 MELCHER The Power Partners. Vo nom = 24 V Vo [V] Rext2 [kΩ] 24.25 24.50 24.75 25.00 25.25 25.50 25.75 26.00 26.25 26.40 3160 1620 1100 825 715 590 511 453 402 383 Vo nom = 48 V Vo [V] Rext2 [kΩ] 48.5 49.0 49.5 50.0 50.5 51.0 51.5 52.0 52.5 52.8 6810 3480 2370 1780 1470 1270 1100 953 845 806 Page 12 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Display Status of LEDs Vo1 > 0.95 to 0.98 Vo1 adj 06002a LEDs "OK" and "i" status versus input voltage Vi OK i Io L Conditions: Io ≤ Io nom , TC ≤ TC max , Vinh ≤ 0.8 V Vi Vi uv Vi min Vi max Vi ov Vo1 > 0.95 to 0.98 Vo1 adj Vi uv = undervoltage lockout, Vi ov = overvoltage lockout Vi abs Vo1 < 0.95 to 0.98 Vo1 adj OK Io L LEDs "OK" and "Io L" status versus output current I o Io Io nom Conditions: Vi min – Vi max , TC ≤ TC max , Vinh ≤ 0.8 V IoL i LED "i" versus case temperature TC TC max Conditions: Vi min – Vi max , I o ≤ I o nom , Vinh ≤ 0.8 V TPTC threshold Vinh threshold i Vinh +0.8 V -50 V LED off +2.4 V LED status undefined +50 V LED "i" versus Vinh Conditions: Vi min – Vi max , I o ≤ I o nom , TC ≤ TC max LED on Fig. 12 Status of LEDs. BCD20018-G Rev AE1, 16-Apr-2018 MELCHER The Power Partners. Page 13 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Electromagnetic Compatibility (EMC) A suppressor diode or a metal oxide VDR (depending upon converter model) together with an input fuse and an input filter form an effective protection against high input transient voltages, which typically occur in most installations, but especially in battery-driven mobile applications. The M Series has been successfully tested to the following specifications: Electromagnetic Immunity Table 9: Immunity type tests Phenomenon Standard Supply related surges RIA 12 3 Level Coupling mode 1 Value applied A4 +i/–i B Direct transients C Indirect coupled transients Source imped. Test procedure In oper. Perf. crit. 2 3.5 • Vbatt 2/20/2 ms 0.2 Ω A 0.1/1/0.1 s 1 positive surge yes 1.5 • Vbatt 5Ω 5 pos. and 5 neg. impulses yes A 960 Vp 10/100 µs D3 1800 Vp 5/50 µs E 3600 Vp 0.5/5 µs F 4800 Vp 0.1/1 µs G 8400 Vp 0.05/0.1 µs H –i/c, +i/–i Waveform 1800 Vp 5/50 µs J 3600 Vp 0.5/5 µs K 4800 Vp 0.1/1 µs L 8400 Vp 0.05/0.1 µs contact discharge ± 8000 Vp 1/50 ns 10 positive and 10 negative discharges A ±15000 Vp 330 Ω 150 pF yes air discharge antenna 20 V/m AM 80% 1 kHz n.a. 80 to 1000 MHz yes A 11 10 V/ m 50% duty cycle, 200 Hz repetition frequency 900 ±5 MHz yes A 50 Ω 60 s positive 60 s negative transients per coupling mode yes A 11 5 pos. and 5 neg. surges per yes A 0.15 to 80 MHz yes A 60 s in all 3 axis yes A 5 Electrostatic discharge (to case) IEC/EN 61000-4-2 4 Electromagnetic field IEC/EN 61000-4-3 x6 –o/c, +o/–o, –o/–i 100 Ω A 11 Electromagnetic ENV 50204 field, pulse modulated 47 Electrical fast transient/burst IEC/EN 61000-4-4 38 capacitive, o/c ± 2000 Vp 8 direct, i/c, +i/–i ± 2000 Vp ± 4000 Vp bursts of 5/50 ns 2.5/5 kHz over 15 ms; burst period: 300 ms Surge IEC/EN 61000-4-5 39 i/c 2000 Vp 1.2/50 µs 12 Ω +i/–i 1000 Vp Conducted disturbances IEC/EN 61000-4- 6 3 10 i, o, signal wires 10 VAC (140 dBµV) AM 80% 1 k Hz 150 Ω Power frequency magnetic field IEC / EN 61000-4-8 3 12 -- 3 4 1 2 3 4 5 6 7 8 9 10 11 12 2Ω 100 A/m A 11 B i = input, o = output, c = case A = normal operation, no deviation from specs.; B = normal operation, temporary loss of function or deviation from specs possible RIA 12 covers or exceeds IEC 60571-1 and EN 50155:1995. Surge D corresponds to EN 50155:2001, waveform A; surge G corresponds to EN 50155:2001, waveform B. Only met with EM (110 V battery) and extended input range models (customer-specific) of BM (24 V battery) and CM (48 V battery). Standard DK models (72 V battery) are not damaged, but overvoltage lockout will occur during the surge. Exceeds EN 50121-3-2:2015 table 6.3 and EN 50121-4:2006 table 1.4. Corresponds to EN 50121-3-2:2015 table 6.1 and exceeds EN 50121-4:2006 table 1.1. Valid for version V104 or higher. Compliance with digital mobile phones. Corresponds to EN 50121-3-2:2015 table 5.2 and EN 50121-4:2006 table 2.2. Covers or exceeds EN 50121-3-2:2015 table 4.3 and EN 50121-4:2006 table 2.3. Corresponds to EN 50121-3-2:2015 table 5.1 and EN 50121-4:2006 table 3.1 (radio frequency common mode). Perf. criterion B for triple-output models. Corresponds to EN 50121-4:2006 table 1.3 for AC systems BCD20018-G Rev AE1, 16-Apr-2018 MELCHER The Power Partners. Page 14 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Electromagnetic Emissions dBµV dBµV/m PMM 8000 PLUS: Peak, conducted Vi+, QP + AV, 2011-08-02, 10:48 h CM1601-9ER, Ui=60 V, Uo=24 V Io= 2 A EN 55022 A (qp) JM131 80 TÜV-Divina, ESVS 30:R&S, BBA 9106/UHALP 9107:Schwarzb., QP, 2011-08-03 Testdistance 10 m, CM1601-9ER, Ui= 60 VDC, Uo=24 V Io= 2 A 50 EN 55011 A 40 JM130 EN 55022 A (av) 60 30 300 >300 >300 >100 2 MΩ Creepage distances ≥ 3.2 3 -- -- -- mm Electric strength test 1 2 3 • • • • • According to IEC/EN 60950, subassemblies connecting input to output are pre-tested with 5.6 kVDC or 4 kVAC. Tested at 300 VDC Input to outputs: ≥ 6.4 mm the input voltage of 250 VAC or 400 VDC Functional insulation between output(s) and case Functional insulation between the outputs Pollution degree 2 environment Overvoltage category II Altitude up to 2000 m insulation is needed between the AC mains and the input of the converter. Only voltage adaption and rectification to the specified input voltage range of a DC/DC converter is needed. The converters are subject to manufacturing surveillance in accordance with the above mentioned standards and with ISO 9001:2008. Isolation Table 15 shows a possible installation configuration, compliance with which causes the output circuit of the DC-DC converter to be an SELV circuit according to IEC/EN 60950 up to a configured output voltage (sum of nominal voltages if in series or +/– configuration) of 48 V. However, it is the sole responsibility of the installer to assure the compliance with the relevant and applicable safety regulations. Max. 250 VAC or 400 VDC The electric strength test is performed in the factory as routine test in accordance with EN 50514 and IEC/EN 60950. The company will not honor any warranty claims resulting from incorrectly executed electric strength field tests. ~ + Mains ~ Safety of Operator-Accessible Output Circuits If the output circuit of a DC-DC converter is operatoraccessible, it shall be an SELV circuit according to the IEC/EN 60950 safety standards. Since the M Series converters provide double or reinforced insulation between input and output based upon a rated primary input voltage of 250 VAC or 400 VDC, only functional 10018a AC-DC front end + Battery Fuse Fuse Max. 250 VAC or 400 VDC DC-DC converter SELV – Earth connection Fig. 17 Schematic safety concept Table 15: Safety concept leading to an SELV output circuit Conditions Front end DC-DC converter Nominal supply voltage Minimum required grade of insulation, to be provided by the AC-DC front end, including mains supplied battery charger Maximum rated DC output voltage from the front end Mains 250 VAC Operational (i.e. there is no need for electrical isolation between the mains supply voltage and theDC-DC converter input voltage) 400 VDC 1 (The Primary circuit rated voltage between any input pin and earth can be up to 250 VAC or 400 VDC.) 1 2 Minimum required Equipsafety status of the ment front end output circuit A – LM Result Measures to achieve the specified safety status of the output circuit Safety status of the DC-DC converter output circuit Double or reinforced insulation, based on 250 VAC and 400 VDC (provided by the DC-DC converter) and earthed case 2 SELV circuit The front end output voltage should match the specified operating input voltage range of the DC-DC converter. The earth connection has to be provided by the installer according to the safety standard IEC/EN 60950. BCD20018-G Rev AE1, 16-Apr-2018 MELCHER The Power Partners. Page 19 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Description of Options Table 16: Survey of options Option 1 2 3 Function of option Characteristic -7 Former standard operational ambient temperature range TA = – 25 to 71°C A Test sockets at front panel for check of output voltage Vo internally measured at the connector terminals E Electronic inrush current limitation circuitry Active inrush current limitation, only for CM, EM, LM models P1 Potentiometer for fine adjustment of output voltage Adjustment range ±5% of Vo nom, excludes R input F Input fuse built-in Fuse not externally accessible, only for FM1000 H Enhanced output to case electric strength test voltage See table Isolation D2 Input and/or output undervoltage monitoring circuitry Safe data signal output (D0 – D9) V23 Input and/or output undervoltage monitoring circuitry ACFAIL signal according to VME specifications (V0, V2, V3) K Coding strip at the connector Ensuring correct population of DIN-racks G RoHS RoHS-compatible for all six substances Models equipped with option P do not provide the R function; pins 14 and 17 are not connected. Option D excludes option V and vice versa. Only available if main output voltage Vo1 = 5.1 V Table 17: Configuration of option A and option P AM – LM1000 Output 1 Type of option AM – LM2000 Output 1 Output 2 Output 1 AM – LM3000 Output 2 Output 3 Potentiometer 1 yes yes yes yes no no Test sockets yes yes yes yes no no Models equipped with option P do not provide the R function; pins 14 and 17 are not connected. Option -7 stays for the operational ambient temperature range from –25 to 71 °C, which may be preferred by some customers for reasons of documentation or approvals. A Test Sockets Test sockets (pin Ø = 2 mm, distance d = 5.08 mm) are located at the front of the converter. The output voltage is sensed at the connector pins inside of the converter. Outputs 2 and 3 of tripleoutput models are not sensed. P Potentiometer Built-in multi-turn potentiometers provide an output voltage adjustment range of minimum ± 5% of Vo nom and are accessible through holes in the front cover. Compensation of voltage drop across connector and wiring becomes easily achievable. For output voltages Vo > Vo nom , the minimum input voltage according to Electrical Input Data increases proportionally to Vo /Vo nom . Triple-output models allow only the adjustment of Vo1. Note: Potentiometers applications. are not recommended for For applications requiring an improved inrush current limitation, an active electronic circuit as shown in fig.18 has been developed. Typical inrush current waveforms of units equipped with this option are shown below. CM models meet the CEPT/ETSI standards for 48 V supply voltage according to ETS 300132-2, if fitted with option E combined with option D6 (input voltage monitoring). Option D6, externally adjustable via potentiometer, is necessary to disable the converter at input voltages below the actual service ranges, avoiding an excessive input current when the input voltage is raised slowly according to ETS 300132-2. Option D6 threshold level Vt i + Vh i (refer to description of option D) should be adjusted to 36 – 40.5 V for 48 V nominal supply voltage (for 60 V systems, threshold should be set to 44 – 50 V). The D output (pin 5) should be connected to the inhibit (pin 2). For applications, where potentiometers are not allowed, refer to option D9. 11018a mobile Control logic FET Rectifier (LM models) E Electronic Inrush Current Limitation Available for CM, EM and LM models. The standard version of the models CM, DM, EM and LM include a passive inrush current limitation with an NTC resistor. BCD20018-G Rev AE1, 16-Apr-2018 Converter - 7 Former Standard Temperature Range Input filter 1 RS RI Ci Fig. 18 Option E block diagram MELCHER The Power Partners. Page 20 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Table 18: Inrush current characteristics with option E Characteristic CM at Vi = 110 VDC typ max EM, LM at Vi = 110 VDC typ max EM, LM at Vi = 372 VDC typ max Unit Iinr p Peak inrush current 6.5 8 2.2 4 7.3 10 A tinr Inrush current duration 22 30 10 20 20 40 ms by DC input voltages do not need to be derated within the full specified input voltage range. Ii [A] 10 F Fuse Not Accessible 11019a 8 Standard M converters have a fuseholder containing a 5 × 20 mm fuse, which is externally accessible and located in the back plate near to the connector. Some applications require an inaccessible fuse. Option F provides a fuse mounted directly onto the main PCB inside the case (only FM1000). CM at 110 VDC EM, LM at 372 VDC 6 EM, LM at 110 VDC tinr 4 tinr Ii = Po /(Vi • η) 2 Normal operation: FET fully conducting t [ms] 0 0 10 20 30 40 The full self-protecting functions of the converter do normally not lead to a broken fuse, except as a result of inverse polarity at the input of an AM, BM, CM, DM, or FM models, or if a power component inside fails. In such cases the defective converter must be returned to the Company for repair. H Enhanced Electric Strenght Test Electric strength test output to case; see table Isolation. Fig. 19 D Undervoltage Monitor Typical inrush current waveforms of CM, EM, and LM converters with option E Precautions: In order to avoid overload of the series resistor RI, the on/off switching cycle should be limited to 12 s, if switched on/off continuously. There should not be more than 10 start-up cycles within 20 s at a case temperature of 25 °C. If CM models are driven by input voltages below 35 VDC or LM models below 100 VAC, the maximum case temperature should be derated by 10 °C, or the total output power should be derated by 20%. EM and LM models driven The input and/or output undervoltage monitor operates independently of the built-in input undervoltage lock-out circuit. A logic "low" (JFET output) or "high" signal (NPN output) is generated at pin 5, when one of the monitored voltages drops below the preselected threshold level Vt. The return for this signal is Vo1– (pin 23). The D output recovers, when the monitored voltage(s) exceed(s) Vt + V h. The threshold level Vt is either adjustable by a potentiometer accessible through a hole in the front cover, or adjusted in the factory to a fixed value specified by the customer. Option D exists in various versions D0 – D9, as shown in the table below: Table 19: Undervoltage monitor functions Output type JFET NPN 2 3 4 Minimum adjustment range of threshold level Vt Vti Vto Typical hysteresis Vh [% of Vt ] for Vt min – Vt max Vhi Vho D1 D5 no yes – 3.5 V – 48 V 1 – 2.3 – 1 D2 D6 yes no Vi min – Vi max 1 – 3.0 – 0.5 – 0.95 – 0.98 Vo1 2 3.0 – 0.5 "0" 2 D3 1 Monitoring Vi Vo1 D7 yes yes Vi min – Vi max 1 D4 D8 no yes – 0.95 – 0.98 Vo1 – "0" D0 D9 no yes – 3.5 V – 48 V 3 – 1.8 – 1 yes no Vi min – Vi max 3 4 – 2.2 – 0.4 – yes yes Vi min – Vi max 3 4 0.95 – 0.98 Vo1 2 2.2 – 0.4  Threshold level adjustable by potentiometer (not recommended for mobile applications) Fixed value between 95% and 98% of Vo1 (tracking) Fixed value, resistor-adjusted according to customer's specification ±2% at 25 °C; individual type number is determined by the company. Adjusted at Io nom BCD20018-G Rev AE1, 16-Apr-2018 MELCHER The Power Partners. Page 21 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters JFET output (D0 – D4): Threshold tolerances and hysteresis: Connector pin D is internally connected via the drain-source path of a JFET (self-conducting type) to the negative potential of output 1. VD ≤ 0.4 V (logic low) corresponds to a monitored voltage level (Vi and/or Vo1) < Vt. The current I D through the JFET should not exceed 2.5 mA. The JFET is protected by a 0.5 W Zener diode of 8.2 V against external overvoltages. If V i is monitored, the internal input voltage after the input filter and rectifier (EM and LM types) is measured. Consequently, this voltage differs from the voltage at the connector pins by the voltage drop ∆V ti across input filter and rectifier. The threshold level of the D0 and D9 options is adjusted in the factory at nominal output current Io nom and TA = 25 °C. The value of ∆V ti depends upon input voltage range (AM, BM, etc.), threshold level Vt , temperature, and input current. Vi , Vo1 status D output, V D Vi or Vo1 < Vt low, L, V D ≤ 0.4 V at I D = 2.5 mA Vi and Vo1 > Vt + Vh high, H, I D ≤ 25 µ A at V D = 5.25 V VD ∆Vti Vhi 11021a Po = Po nom Po = 0 Po = 0 Connector pin D is internally connected via the collectoremitter path of a NPN transistor to the negative potential of output 1. VD ≤ 0.4 V (logic low) corresponds to a monitored voltage level (Vi and/or Vo1) > Vt + Vh. The current ID through the open collector should not exceed 20 mA. The NPN output is not protected against external overvoltages. VD should not exceed 40 V. Po = Po nom VD high NPN output (D5 – D9): VD low Vti Vi Fig. 22 Vi , Vo1 status D output, VD Vi or Vo1 < Vt high, H, I D ≤ 25 µA at VD = 40 V Vi and Vo1 > Vt + Vh low, L, VD ≤ 0.4 V at I D = 20 mA Definition of Vti, ∆V ti , and V hi (JFET output) 11006 Vo1+ Rp Input ID D VD Vo1– Fig. 20 Options D0 – D4, JFET output 11007a Vo1+ Input Rp ID D VD Vo1– Fig. 21 Options D5 – D9, NPN output BCD20018-G Rev AE1, 16-Apr-2018 MELCHER The Power Partners. Page 22 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Input voltage monitoring NPN VD VD high 11008a 3 VD low 3 3 3 t 0 ID ID high ID low 0 t JFET VD VD high VD low 0 t th1 Vo1 Vo1 nom 1 0.95 tlow min4 tlow min4 tlow min4 thigh min th1 t 0 Vi [V DC] Vti + Vhi Vti t 0 Input voltage failure Input voltage sag Switch-on cycle Output voltage monitoring NPN VD VD high Switch-on cycle and subsequent input voltage failure 2 3 3 VD low t 0 ID ID high ID low 0 t Fig. 23 JFET VD VD high Relationship between Vi, Vo1, VD, ID, and Vo1/Vo nom versus time. VD low 0 t tlow min4 Vo1 Vo1 nom Vto +Vho Vto 1 2 3 t 0 4 See Electrical Output Data for hold-up time. With output voltage monitoring the hold-up time th = 0 The D signal remains high, if the D output is connected to an external source. t low min = 40 – 200 ms, typically 80 ms Output voltage failure V ACFAIL Signal (VME) Available for converters with Vo1 = 5.1 V. This option defines an undervoltage monitoring circuit for the input or the input and main output voltage equivalent to option D and generates the ACFAIL signal (V signal), which conforms to the VME standard. The low state level of the ACFAIL signal is specified at a sink current of IV = 48 mA to VV ≤ 0.6 V (open-collector output). The BCD20018-G Rev AE1, 16-Apr-2018 pull-up resistor feeding the open-collector output should be placed on the VME backplane. After the ACFAIL signal has gone low, the VME standard requires a hold-up time t h of at least 4 ms before the 5.1 V output drops to 4.875 V, when the 5.1 V output is fully loaded. This hold-up time t h is provided by the internal input capacitance. Consequently the working input voltage and the MELCHER The Power Partners. Page 23 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters threshold level Vti should be adequately above the minimum input voltage Vi min of the converter, so that enough energy is remaining in the input capacitance. If the input voltage is below the required level, an external hold-up capacitor (Ci ext) should be added. Formula for threshold level for desired value of t h : 2 • Po • (t h + 0.3 ms) • 100 ––––––––––––––––––––– + Vi min2 C i min • η Vti = whereas: Ci min = minimum internal input capacitance [mF], according to the table below Ci ext = external input capacitance [mF] Po = output power [W] η = efficiency [%] = hold-up time [ms] th Vi min = minimum input voltage [V] Vt i = threshold level [V] Notes: The threshold level V ti of option V2 and V3 is adjusted in the factory to a value according to the table below. A decoupling diode should be connected in series with the input of AM, BM, CM, DM, and FM converters to avoid the input capacitance discharging through other loads connected to the same source voltage. If LM models are powered by AC, an external input capacitor cannot be applied unless an additional rectifier is provided. Formula for additional external input capacitor 2 • Po • (t h + 0.3 ms) • 100 – C i min C i ext = ––––––––––––––––––––– η • (Vti 2 – Vi min2) Table 20: Available internal input capacitance and factory potentiometer setting of Ut i with resulting hold-up time Types AM BM CM DM EM FM LM Ci min Vt i th 2.6 0.67 0.37 0.14 0.14 0.37 0.14 mF 9.5 19.5 39 61 104 39 120 VDC 0.34 0.69 1.92 1.73 6.69 2.92 8.18 ms Option V operates independently of the built-in input undervoltage lockout circuit. A logic "low" signal is generated at pin 5 as soon as one of the monitored voltages drops below the preselected threshold level V t. The return for this signal is Vo1– (pin 23). The V output recovers, when the monitored voltage Unit exceeds Vt + Vh. The threshold level Vt is either adjustable by a potentiometer, accessible through a hole in the front cover, or adjusted in the factory to a determined customer-specific value. Versions V0, V2 and V3 are available as shown below. Table 21: Undervoltage monitor functions V output (VME compatible) V2 V3 V0 1 2 3 4 Monitoring Vi V o1 Minimum adjustment range of threshold level Vt V ti V to yes no V i min – V i max 1 yes yes V i min – V i max 1 – 3.0 – 0.5 - 2 3.0 – 0.5 "0" - 2.2 – 0.4 - 0.95 – 0.98 V o1 2 2.2 – 0.4 "0" 0.95 – 0.98 V o1 34 yes no V i min – V i max yes yes V i min – V i max 3 4 Typical hysteresis U h [% of Vt ] for Vt min – Vt max V hi V ho Threshold level adjustable by potentiometer (not recommended for mobile applications). Fixed value between 95% and 98% of Vo1 (tracking), output undervoltage monitoring is not a requirement of VME standard. Adjusted at Io nom. Fixed value, resistor-adjusted (±2%) acc. to customer's specifications; individual type designation is determined by the company. 11009a V output (V0, V2, V3): Vo1+ Connector pin V is internally connected to the open collector of a NPN transistor. The emitter is connected to the negative potential of output 1. VV - 0.6 V (logic low) corresponds to a monitored voltage level (Vi and/or Vo1) < U t. The current I V through the open collector should not exceed 50 mA. The NPN output is not protected against external overvoltages. VV should not exceed 80 V. Vi, Vo1 status Input Rp IV V VV Vo1– V output, VV V i or V o1 < V t low, L, V V ≤ 0.6 V at I V = 50 mA Fig. 24 V i and V o1 > V t + V h high, H, I V ≤ 25 µA at V V = 5.1 V Output configuration of options V0, V2, V3 BCD20018-G Rev AE1, 16-Apr-2018 MELCHER The Power Partners. Page 24 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters VV Threshold tolerances and hysteresis: Vi is monitored after the input filter and rectifier (EM and LM models). Consequently, this voltage differs from the voltage at the connector pins by the voltage drop ∆Vt i across input filter and rectifier. The threshold level of option V0 is factoryadjusted at Io nom and TA = 25 °C. ∆Vt i depends upon the input voltage range (AM, BM, ...), threshold level Vt i, temperature, and input current. ∆Vti Vhi 11023a Po = Po nom Po = 0 Po = 0 Po = Po nom VV high VV low Vi Vti Fig. 25 Definition of Vti, ∆Vti and Vhi Input voltage monitoring 3 tlow min 2 tlow min 2 tlow min 2 V2 VV UV high 3 3 11010a 4 4 tlow min 2 tlow min 2 VV low t 0 V3 VV VV high 3 3 3 VV low t 0 th th 1 Vo1 5.1 V 4.875 V 1 2.0 V 0 t Vi [VDC] Vti + Vhi Vi t 0 Input voltage failure Input voltage sag Switch-on cycle Switch-on cycle and subsequent input voltage failure Output voltage monitoring V2 VV VV high Fig. 26 4 VV low Relationship between Vi, Vo1, VV, I V, and Vo1 /Vo nom versus time. 4 t 0 V3 VV VV high tlow min 3 2 1 2 3 3 4 4 VV low 0 t Vo1 5.1 V 4.875 V VME request: minimum 4 ms t low min = 40 – 200 ms, typically 80 ms VV level not defined at Vo1 < 2.0 V The V signal drops simultaneously with the output voltage, if the pull-up resistor R P is connected to Vo1+. The V signal remains high, if R P is connected to an external source. K Coding Strip 2.0 V 0 t Vi A plastic part across the connector ensures correct population of the DIN-rack. G RoHS Vti + Vhi Vti RoHS-compatible for all six substances. t 0 Output voltage failure BCD20018-G Rev AE1, 16-Apr-2018 MELCHER The Power Partners. Page 25 of 26 M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Accessories A great variety of electrical and mechanical accessories are available including: European Projection 30 09125 15 – Various mating H11 connectors including solder, fast-on, or press-fit terminals – Pair of connector retention clips HZ Z 01209-G – Code key system: 5 coding wedges HZZ00202-G – Various front panels for 19" rack mounting – Flexible H11 PCB board HZ Z 01208-G for connecting with a mother board – Universal mounting bracket UMB-LHMQ (HZZ00610-G) for chassis or DIN-rail mounting in upright position. – DIN-rail mounting brackets DMB-MHQ (HZZ00619-G) – Mounting plate M (HZ Z 01208) for chassis or a wall mounting, where only frontal access is given – Battery sensor [S-KSMH...] for using the converter as battery charger (different cell characteristics). l 65 l: 2 m standard length other cable lengths on request adhesive tape Battery temperature sensor S-KSMH... For additional accessory product information, see the accessory data sheets listed with each product series or individual model at our web site. Flexible H11 PCB HZ Z 01208-G Pair of connector retention clips HZ Z 01209-G Mounting plate M (HZ Z 01210), connector with fast-on terminals (HZ Z 00101-G), secured with retention clips (HZ Z 01209-G) DIN-rail mounting brackets DMB-MHQ (HZZ00619-G) Universal mounting bracket for DIN-rail mounting (HZ Z 00610-G) Different front panels NUCLEAR AND MEDICAL APPLICATIONS - These products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. Copyright © 2018, Bel Power Solutions Inc. All rights reserved. BCD20018-G Rev AE1, 16-Apr-2018 MELCHER The Power Partners. belfuse.com/power-solutions Page 26 of 26
BM1501-9R 价格&库存

很抱歉,暂时无法提供与“BM1501-9R”相匹配的价格&库存,您可以联系我们找货

免费人工找货