FNP300-1012G

FNP300-1012G

  • 厂商:

    POWER-ONE

  • 封装:

    -

  • 描述:

    AC/DC CONVERTER 2X12V 300W

  • 数据手册
  • 价格&库存
FNP300-1012G 数据手册
The FNP300 Series provides highly-efficient AC-DC power supplies, each with one high current output and an additional standby output, which can be used in a wide range of applications. Passive current share along with internal ORing diodes allow the FNP300 to be used in redundant, hot-swap applications. All models meet international safety standards and display the CE Mark for the low Voltage Directive. Key Features & Benefits • • • • • • • • • • • RoHS lead free solder and lead solder exempted products are available Wide input voltage range 85-264 VAC Two outputs (one high current output) Low conducted and radiated EMI (EN 55022 class B) Safety approved to UL/CSA 62368-1, EN 62368-1 and IEC 62368-1 High density design 4” x 1.58” x 8.5” cassette Highly efficient topology I2C interface Overtemperature, output overvoltage, and output overcurrent protection Supervisory signaling Included ORing diode for true redundant operation Applications • Telecommunication Equipment FNP300 Series 2 1. MODEL SELECTION MODEL INPUT VOLTAGE VAC OUTPUT 1 OUTPUT 2 VO NOM VDC IO MAX ADC VO NOM VDC IO MAX ADC RATED POWER W FNP300-1012G FNP300-1012HG * 85-264 12 25 12 0.7 310 FNP300-1024G 85-264 24 12.5 12 0.7 310 FNP300-1048G 85-264 48 6.25 12 0.7 310 * H option indicates hiccup current limitation OPTIONS SUFFIXES TO ADD TO PART NUMBER RoHS lead solder exemption No RoHS character required. RoHS compliant for all 6 substances Add "G" as the last character of the part number. 2. ABSOLUTE MAXIMUM RATINGS Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long-term reliability, and cause permanent damage to the converter. PARAMETER CONDITIONS/DESCRIPTION Input Voltage Continuous Transient, 60 ms Operating Temperature Ambient; Vi min-Vi max, Io nom, cooling by internal fan Storage Temperature Non-operational MIN MAX UNITS 264 300 VAC VAC 0 55 °C -40 85 °C 3. INPUT SPECIFICATIONS All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. PARAMETER CONDITIONS/DESCRIPTION Input Voltage MIN NOM MAX UNITS 85 115/230 264 VAC Turn-On Input Voltage Ramping up 70 - 85 VAC Turn-Off Input Voltage Ramping down 70 - 85 VAC 47 50/60 63 Hz 15/20 A Input Frequency Inrush Current Limitation 115/230 VAC Power Factor Vi nom, Io nom Efficiency Vi = 230 VAC, Io nom 0.96 FNP300-1012G FNP300-1024G FNP300-1048G 83 86 88 % tech.support@psbel.com FNP300 Series 3 4. OUTPUT SPECIFICATIONS All specifications apply over specified input voltage, output load, and temperature range unless otherwise noted. PARAMETER Output Voltage Setpoint Accuracy FNP300-1012G Output Voltage Setpoint Accuracy FNP300-1024G Output Voltage Setpoint Accuracy FNP300-1048G Output Current V1 Output Current V2 Output Current V1 Output Current V2 Output Current V1 Output Current V2 CONDITIONS/DESCRIPTION MIN Vi = 230 VAC, Io1 @ 12.5 ADC, TC = 25 °C MAX UNITS -0.5 0.5. % Vo nom Vi = 230 VAC, Io1 @ 3.125 ADC, TC = 25 °C -0.5 0.5. % Vo nom Vi = 230 VAC, Io1 @ 12.5 ADC, TC = 25 °C -0.5 0.5. % Vo nom 25 0.7 12.75 0.7 6.4 0.7 ADC ADC ADC ADC ADC ADC FNP300-1012G FNP300-1012G FNP300-1024G FNP300-1024G FNP300-1048G FNP300-1048G 0 0 0 0 0 0 NOM 25 0.7 12.5 0.7 6.25 0.7 Static Line Regulation V1 Vi min-Vi max, Vi nom, 5-100% Io nom -0.5 0.5 % Vo nom Static Load Regulation V1 (Droop Characteristic) Vi min-Vi max, Vi nom, 5-100% Io nom -5 5 % Vo nom Hold-Up Time Starting at Vi = 230 VAC, Po nom 20 Dynamic Load Regulation Load change = 33%, dIo/dt = 2A/s voltage deviation recovery time -2 Start-Up Time Vi nom, Io nom Output Voltage Ripple and Noise Vi nom, Io nom, 20 MHz bandwidth 5. ms 2 400 % Vo nom s 1 s 120 mVpp PROTECTION All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. PARAMETER CONDITIONS/DESCRIPTION Input Fuse Not user accessible Input Transient Protection With varistor Output Overvoltage Protection Overtemperature Protection MIN NOM MAX UNITS 130 130 130 122 % Io nom % Io nom % Io nom % Vo nom % Vo no % Vo no 6.3AT No-load and short circuit proof short circuit proof overload (latch style) Latch style FNP300-1012G Latch style FNP300-1024G Latch style FNP300-1048G 110 115 115 115 Automatic power shutdown at TC = 95 °C Asia-Pacific +86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2020 Bel Power Solutions & Protection BCD20015-G_AE FNP300 Series 4 6. CONTROL All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. PARAMETER CONDITIONS/DESCRIPTION I2C Reports information and monitors alarm functions Digital Bus PS Seated Signal PS Remote Shutdown AC fail pre-warning (I2C & OC) * Contact closure to GND TTL compatible signal, open collector. Power supply enabled at Low or TTL "0" (e.g. by connecting of pin 22 to 0V or GND) and inhibited to latching mode** at High or TTL "1", or leave it open. Supervisory AC input voltage; Pre-warning time >6 ms DC fail (I2C & OC) * Supervisory under- and overvoltage pre-ORing diode of V1 Temperature Warning (I2C & OC) * Indicates if unit is operating normally or in overtemperature, Pre-warning time >10 ms Fan OK (I2C & OC) * Indicates if fan is operating or has failed Current Share Droop load characteristic for V1 and V2 Status Indication LEDs: DC OK (green), AC OK (green) NOTE: * Signal provided by I2C interface or by open collector (OC) ** (1) Standard FNP300 models (without "H" at the end of part number) have latching inhibit function, i.e., once PSU is inhibited, it needs input power re-cycle to allow using enable state again. (2) FNP300 variants marked with "H" character do have non-latching inhibit function so there's no need to re-cycle input power when enabling unit after inhibit state. 7. FEATURES All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. PARAMETER Fan speed control µC supply voltage in-/output (Pin 10) CONDITIONS/DESCRIPTION 4 fan speed levels depending on inlet temperature Fan speed level and temperature information available on I2C digital bus If unit is operating: 5 to 7V is provided at pin 10. If unit is NOT operating, pin 10 is input from a parallel connected unit for µC supply. 8. CHARACTERISTIC CURVES Figure 1. Efficiency vs. Output Load tech.support@psbel.com FNP300 Series 5 Figure 2. Efficiency vs. Input Voltage and Ambient Temperature, Io = Io nom 9. SAFETY AND ISOLATION SPECIFICATIONS The electric strength test is performed in the factory as routine test in accordance with EN 550116, IEC/EN 62368-1, and UL 1950 and should not be repeated in the field. Bel Power Solutions will not honor any warranty claims resulting from electric strength field tests. PARAMETER Safety Standards Insulation Safety Rating Electric Strength Test Voltage CONDITIONS/DESCRIPTION MIN UL/CSA 62368-1 EN 62368-1 IEC 62368-1 Input/Case Input/Output Output/Case Input/Case Input/Output Output/Case NOM MAX UNITS Certified Basic Reinforced Functional 2121 4242 500 VDC 10. EMC SPECIFICATIONS All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. PARAMETER DESCRIPTION Electrostatic Discharge IEC/EN 61000-4-2, level 4 (contact/air) 8/15 kV, criterion B CRITERION Electromagnetic Field IEC/EN 61000-4-3, level 3 10 V/m, criterion A Electrical Fast Transients / Burst IEC/EN 61000-4-4, level 4 (direct/capacitive) 2/1 kV, criterion B Surge IEC/EN 61000-4-5, level 3 (L/L, L/C) 1/2 kV, criterion B Voltage Dips and Interruptions IEC/EN 61000-4-11 Criterion B RF Conducted Immunity IEC/EN 61000-4-6 10 VAC, AM 80%, 1 kHz, criterion A Emissions Radiated/Conducted CISPR 22/EN 55022/EN 61204 Class B Harmonics IEC/EN 61000-3-2 Class B Voltage Fluctuation and Flicker IEC/EN 61000-3-3 Pass Asia-Pacific +86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2020 Bel Power Solutions & Protection BCD20015-G_AE FNP300 Series 6 11. ENVIRONMENTAL & RELIABILITY SPECIFICATIONS All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. PARAMETER CONDITIONS/DESCRIPTION MAX UNITS Operating Humidity Relative humidity, non-condensing MIN 10 NOM 90 % Storage Humidity Relative humidity, non-condensing 5 95 % Shock IEC/EN 60068-2-27, 11 ms 30 gn Sinusoidal Vibration IEC/EN 60068-2-6 2-8 Hz 8-200 Hz 200-500 Hz MTBF MIL-HDBK-217F Notice 2, GB, 25 °C 7.5 2 4 mil gn gn 200 kh 12. MECHANICAL SPECIFICATIONS All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX 101.6 x 40.1 x 215.9 4.00 x 1.58 x 8.50 1.00 2.205 Mechanical Dimensions (W x H x D) Weight UNITS mm in kg lb Figure 3. Mechanical Dimensions tech.support@psbel.com FNP300 Series 7 AI RF LO W 13. CONNECTORS Rear View Connector: Molex (15-06-0241) Figure 4. Output Connector Descriptions OUTPUT CONNECTOR DESCRIPTION PIN LOCATION REFERENCE NAME 12V Output 24V Output 48V Output 12V Output RTN 24V Output RTN 48V Output RTN 4,5,6,16,17,18 4,5,6,16,17,18 4,5,6,16,17,18 1,2,3,13,14,15 1,2,3,13,14,15 1,2,3,13,14,15 Vo1 Vo1 Vo1 Vo1 RTN Vo1 RTN Vo1 RTN AC-fail, DC-fail, Temp.-fail 9 PS_FAIL Power Supply Present Signal 23 PS_PRSNT_L Serial Data Line 11 SDA Serial Clock Line 12 SCL Address Input Line A0 21 AO Address Input Line A1 20 A1 5 to 7V 10 µC supply voltage bus FAN OK 24 FAN_FAIL PS Remote Shut Down 22 PS_RSD_H 12V Standby RTN 7 Vo2 RTN / Logic Ground / 5 to 7V RTN 12V Standby 19 Vo2 Address Input Line A2 8 A2 NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. Asia-Pacific +86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2020 Bel Power Solutions & Protection BCD20015-G_AE
FNP300-1012G 价格&库存

很抱歉,暂时无法提供与“FNP300-1012G”相匹配的价格&库存,您可以联系我们找货

免费人工找货
FNP300-1012G
  •  国内价格 香港价格
  • 1+2235.160531+267.21467

库存:26