Accessories
Front Panels and DIN-Racks
Front Panels
Description
Front panels are available for 19" DIN-rack mounting of 3 U
cassette type power supplies in Schroff system version
(Intermas system on request) and may be attached to the
converter by means of countersunk screws.
An assembly kit, consisting of a front panel and a support
bracket, enables arrangement of two standard cassettes with
up to six output voltages in 6 U configuration.
All front panels are of colorless anodized aluminum and
delivered with one or 2 grey plastic handles of 3 TE for easy
pull-out and 2 or 4 hand-press insertable plastic retainers with
captive screws for fixing to the rack.
Note: Custom specific front panels are available on request.
Dimensions according to DIN 41494-1 (IEC 60297):
Width:
1 TE = 5.08 mm (0.20")
Height:
1 U = 44.45 mm (1.750")
Tolerances: ±0.2 mm, unless otherwise specified.
Note: In Europa often HE instead of U is used.
Schroff System for 3 U Rack
Q-, P- Series Front Panels in 4, 5, or 6 TE
2.5±0.1
6.4 ±0.1
9.5
12002a
These front panels available in three versions and fit to all
DC-DC converters of the Q- and P-Series; see fig. 1 for the
mechanical details.
Table 1: Front panel selection for P and Q Series
Designation
G04-Q01
HZZ00835
P
G04-Q04
HZZ00840
Q01
Q
G05-Q01
HZZ00836
Q04
P
G05-Q04
HZZ00841
Q
G06-Q01
HZZ00839
6
30.2
Q01
Q04
P
G06-Q04
HZZ00842
8
40.3
Q01
Q
G08-Q01
HZZ00846
Q04
P
G08-Q04
HZZ00850
104 ±0.1
Q
Q04
4 13
Note: For using several units next to each other, we advise to
pack them not too densely in order to assure good thermal
management (see also relevant data sheet).
X
9.2 ±0.1
Q01
50
Panel
type
20.6
20.0
25.1
Conv.
series
13
5
Case
0.2
4
X
mm
128.4
122.4
TE
Cut out for P Series only
Delivery contents:
Front panel, grey plastic handle, 3 countersunk screws, set of
2 plastic retainers with captive screws, and assembly
instruction.
Fig. 1
Front panel for P and Q Series converters
MELCHER
BCD.00495 Rev AB, 05-Mar-2015
The Power Partners.
Page 1 of 5
Accessories
Front Panels and DIN-Racks
M and LH Series Front Panels in 8 TE
18.4 ±0.1
2.5 ±0.1
7
12004a
This front panel fits to all 50 Watt DC-DC and AC-DC
converters of the M Series (case M02) and LH Series
(case H02).
Table 2: Front panel selection for M and LH Series
Panel type
Designation
M02
M
H02
LH
G08-M02
HZZ00802
12.2
26
100 ±0.1
Converter
series
85
40.3
Case
size
50.5
8
mm
128.4
122.4
TE
Delivery contents:
Front panel with grey plastic handle, 2 countersunk
screws, set of 2 plastic retainers with captive screws, and
assembly instruction.
0.2
12003a
9
40.3 (8 TE)
11.7 ±0.1
2.5 ±0.1
31.5 ±0.1
4.4 ±0.1
26
Fig. 3
Front panel for PSL Series
94.5 ±0.1
4
128.4
122.4
50
cut out for option D
Front Panels 12 TE for S, HR, HRL, ER, ERL, PSS
Front Panels 16 TE for K, HRP, ERP, PSK
0.2
18.2 ±0.1
These front panels fit to the converter series mentioned in the
table below
Table 4: Front panel selection for S, K, R, PSS, PSK Series
40.3 (8 TE)
Width x
TE
mm
Case
size
Converter
series
Panel type
Designation
12
S01
PSS
S02
S
G12-S
HZZ00845
60.6
Fig. 2
Front panel for M and LH Series
ERL, HRL
16
PSL Series Front Panel in 8 TE
This front panel fits to the Switching Regulators of the PSL
Series (case size L04).
Table 3: Front panel selection for PSL Series
TE
mm
Case
size
8
40.3
L04
Converter
series
Panel type
Designation
PSL
G08-L
HZZ00805
PSL with opt. D
G08-L04-D
HZZ00816
81.0
K01
PSK
K02
K
G16-K
HZZ00831
ERP, HRP
Delivery contents:
Front panel with grey plastic handle, two countersunk screws,
set of four plastic retainers with captive screws and assembly
instructions.
Delivery contents:
Front panel with grey plastic handle, 2 countersunk
screws, set of 2 plastic retainers with captive screws and
assembly instructions.
MELCHER
BCD.00495 Rev AB, 05-Mar-2015
The Power Partners.
Page 2 of 5
Accessories
Front Panels and DIN-Racks
16.5
9
12007a
2 ±0.1
2.5 ±0.1
27.4 ±0.1
12005a
4.4 ±0.1
4
29
width x
9.7 ±0.1
0.2
16.5
128.4
122.4
103 ±0.1
50
0.6
width x
cut out for option D
Fig. 4
Front panel for S, K, R, PSS, PSK Series; see table 4
Fig. 5
Intermas system front panels (various case sizes)
Intermas System for 3 U Rack
The major differences between the Intermas and the Schroff
system front panels are the thickness (2 mm instead of 2.5
mm), the hole size for the plastic retainers, and a small cutout on each side; see figure 5. All other dimensions are
specified in the relevant Schroff front panel drawings.
The following Intermas front panels are available on request:
Table 6: Intermas front panel selection
Width x
TE
mm
Case
size
Converter
series
Panel type
Designation
LH
F08-M02
HZZ00702
8
40.3
H02
M02
M
8
40.3
L04
PSL
F08-L
HZZ00705
PSL with opt. D
F08-L04-D
HZZ00716
S01
PSS
S02
S, HR, HRL, ER, ERL
F12-S
HZZ00732
12
16
60.6
81.0
K01
PSK
K02
K, HRP, ERP
F16-K
HZZ00731
Delivery contents:
Front panel with grey plastic handle, 2 countersunk screws
and assembly instructions.
MELCHER
BCD.00495 Rev AB, 05-Mar-2015
The Power Partners.
Page 3 of 5
Accessories
Front Panels and DIN-Racks
Schroff System Kit for 6 U Rack
2.5 ±0.1
12008b
To configure Power-One converters for use in 6 U racks, a
special assembly kit has been created consisting of a doubleheight front panel together with a support bracket for 2
converters as shown in figure 6.
All other dimensions are given in the relevant 3 U front panel
drawings according to their case size. The assembly kit is
available with the type designation according to the following
table:
Table 7: 6 U assembly kit selection
5
25.1
8
40.3
12
60.6
16
81.0
Case Converter
size series
Type
Designation
Q01
Q
Kit G05-6HE-Q01
HZZ00838
Q04
P
Kit G05-6HE-Q04
HZZ00844
H02
LH
Kit G08-6HE-M02
HZZ00804
M02 M
S01
PSS
S02
S, HR, HRL, ER, ERL
K01
PSK
K02
K, HRP, ERP
P Series
only
261.8
255.8
Width x
TE
mm
Support
angel P/Q
XMS052
Kit G12-6HE-S
HZZ00833
Kit G16-6HE-K
HZZ00832
Delivery contents:
Double-height front panel with 2 grey plastic handles, 4
countersunk screws, set of 2 plastic retainers with captive
screws, a support bracket, and assembly instruction.
Supporting Angle P/Q HZZ1302-G
P Series
only
0.2
The kit contains the support angel XMS052-G and 2 counter
sunk screws in a bag.
width x
Fig. 6
Front panel for 6 U configuration (various case sizes).
Different additional holes depending on the model are not
shown in the drawing.
MELCHER
BCD.00495 Rev AB, 05-Mar-2015
The Power Partners.
Page 4 of 5
Accessories
Front Panels and DIN-Racks
DIN-Rack Systems
Complete 19" rack with side walls, transversal rails, and
mounting flanges. 6 guiding rails are included for set up of a
system. The rails shall be fixed to the rack by the included
screws (12 screws M2.5 x 12 and 12 nuts).
The rack can be used for 19" cassette style converters such
as Q, P, M, K, S, R, etc. (additional guiding rails XKR001-G
may be necessary).
Part no.:
Size:
Guiding rails:
MQB02002G (system Rittal)
19" × 3 U / 84 HP (483 × 132 × 235 mm)
HZZ01228-G (10 pcs XKR001-G in a bag)
Enhanced version for Railway application (system Schroff):
Part no.:
Guiding rails:
MQB02020G
XAD.00056
485 mm (for 19")
465.1 mm (for 19")
450 mm (for 19")
19" = 482.6 mm
23" = 584.2 mm
n • U, U = 1.75" = 44.45 mm
1U
6.35 mm
1U
6.35 mm
12056a
1 HP
1 HP = 0.2 " = 5.08 mm
Fig. 7
19" DIN-Rack systems
Dimensions in according to DIN 41494-1 (IEC 60297):
Width: 1 HP (or TE) = 5.08 mm (0.20"); height: 1 U (or HE) = 44.45 mm (1.750")
Tolerances ±0.2 mm, unless otherwise specified.
NUCLEAR AND MEDICAL APPLICATIONS - These products are not designed or intended for use as critical components in life support
systems, equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
www.belpowersolutions.com/power
MELCHER
BCD.00495 Rev AB, 05-Mar-2015
The Power Partners.
Page 5 of 5
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Bel Power Solutions:
G08-M02 G12-S