Linear Power Supplies Data Sheet
Features
• Worldwide AC Input Capabilities:
100/120/220/230/240 VAC
• ±0.05% Output Regulation
• Low Output Ripple
• UL, CSA, and TÜV Approvals
• Mean Time Before Failure (MTBF) in Excess of
300,000 Hours
• CE marked to Low Voltage Directive
• 100% Burn-In
• 2 Year Warranty
• Overvoltage Protection (OVP) Standard on 5V
Single Outputs, Optional for other outputs under 48V
Description
Power-One produces the industry’s broadest selection of
Linear power supplies with output voltages from 5 volts
through 250 volts. Rugged technology and proven design
merge to create quiet, highly-regulated, dependable DC
power.
The Linear power supplies are approved to domestic and
international regulatory standards, and are CE Marked to
the Low Voltage Directive (LVD).
Overvoltage Protection Options
OVERVOLTAGE PROTECTION OPTIONS
These optional overvoltage protection modules are offered for use with
Power-One’s Linear power supplies. Each is user adjustable from 6.4V to 34V.
OVP SELECTION GUIDE
MODEL
CASE SIZE
OVP MODULES REQUIRED
SINGLE
OUTPUT
B,C,N,D
(1) OVP-12
E,F
(1) OVP-24
DUAL
OUTPUT
AA,B,BB,CC
(1) OVP-12 protects both outputs
E
(1) OVP-24 protects both outputs
OVP-12
TRIPLE
OUTPUT
AA,BAA,D
CBB, 131
(1) OVP-12 protects both 12V
through 15V outputs
DBB,DCC
PEAK
CURRENT
MODELS
NOTE:
N,BAA,CBB
131, CP340-A
CP510-A
(1) OVP-12 protects any output
not provided with built-in OVP
Outputs with factory built-in OVP are indicated in the Voltage/Current Rating
Chart for each model. OVP is not available for 48V through 250V models.
OVP-24
REV. FEB 11, 2005
Page 1 of 9
www.power-one.com
Linear Power Supplies Data Sheet
Single-Output Models
Unsigned output voltages are isolated and can be used as either + or - polarities.
Output
Voltage
(VDC)
Output
Current
(Amps)
Model
(Input Voltage
of 100 to 240VAC)
Case
Type
Additional
Features & Notes
Single Output Models- 5V to 48Vout
Case
Type
Dimensions
(Inches)
AA
6.50 x 4.00 x 2.10
B
4.87 x 4.00 x 2.10
BAA
10.25 x 4.00 x 2.95
BB
7.00 x 4.87 x 2.95
C
5.62 x 4.87 x 2.95
5
1.5
HA5-1.5/OVP-A
B
A
CBB
11.00 x 4.87 x 3.28
5
3
HB5-3/OVP-A
B
A, C
CC
9.38 x 4.87 x 3.28
5
6
HC5-6/OVP-A
C
A, C
CP131
11.00 x 4.87 x 3.28
5
9
HN5-9/OVP-A
N
A, C
CP510-A 8.25 x 4.87 x 3.28
5
12
HD5-12/OVP-A
D
A, C
D
9.00 x 4.87 x 3.28
5
18
HE5-18/OVP-A
E
A, C
DBB
14.25 x 4.87 x 3.38
5
25
F5-25/OVP-A
F
A, C, D, H
DCC
15.00 x 4.88 x 4.55
5
35
G5-35/OVP-A
F
A, C, D, H
E
14.00 x 4.87 x 3.53
5
50
CP197-A
F
A, C, D
F
16.75 x 4.88 x 5.00
12
1.7
HB12-1.7-A
B
C
N
7.00 x 4.87 x 3.28
12
3.4
HC12-3.4-A
C
C
12
5.1
HN12-5.1-A
N
C
12
6.8
HD12-6.8-A
D
C
Case
Type
Dimensions
(Millimeters)
12
10.2
HE12-10.2-A
E
C
12 to 15
0.9
HA15-0.9-A
B
12 to 15
16
F15-15-A
F
C, D, H
15
1.5
HB15-1.5-A
B
C
15
3
HC15-3-A
C
C
15
4.5
HN15-4.5-A
N
C
15
6
HD15-6-A
D
C
15
9
HE15-9-A
E
C
24
1.2
HB24-1.2-A
B
C
24
2.4
HC24-2.4-A
C
C
24
3.6
HN24-3.6-A
N
C
24
4.8
HD24-4.8-A
D
24
7.2
HE24-7.2-A
E
24 to 28
0.5
HA24-0.5-A
B
C
C
24 to 28
12
F24-12-A
F
C, D, H
28
1
HB28-1-A
B
C
28
2
HC28-2-A
C
C
28
3
HN28-3-A
N
C
28
4
HD28-4-A
D
C
28
6
HE28-6-A
E
C
48
0.5
HB48-0.5-A
B
48
1
HC48-1-A
C
48
3
HD48-3-A
D
C
48
4
HE48-4-A
E
C
REV. FEB 11, 2005
Page 2 of 9
AA
165.10 x 101.60 x 53.34
B
123.70 x 101.60 x 53.34
BAA
260.35 x 101.60 x 74.93
BB
177.80 x 123.70 x 74.93
C
142.75 x 123.70 x 74.93
CBB
279.40 x 123.70 x 83.31
CC
238.25 x 123.70 x 83.31
CP131
279.40 x 123.70 x 83.31
CP510-A 209.55 x 123.70 x 83.31
D
228.60 x 123.70 x 83.31
DBB
361.95 x 123.70 x 85.85
DCC
381.00 x 123.95 x 115.57
E
355.60 x 123.70 x 89.66
F
425.50 x 123.95 x 127.00
N
177.80 x 123.70 x 83.31
(See Additional Features Column)
A Overvoltage protection, set at 6.2 V ±0.4 V.
B Non-adjustable 3-terminal regulator.
C Remote sense provided.
D With output inhibit and parallel
operation master/slave capability.
E With output inhibit.
F Adjustable 3-terminal regulator.
G Can be made into an isolated output by
removing jumper W1.
H Model requires 100 LFM forced-air
cooling above 75% of rated output
power at 50 degrees C.
www.power-one.com
Linear Power Supplies Data Sheet
Dual-Output Models
Unsigned output voltages are isolated and can be used as either + or - polarities.
Output
Voltage
(VDC)
Output
Current
(Amps)
Model
(Input Voltage
of 100 to 240VAC)
Case
Type
Additional
Features & Notes
Dual Output Models- 5V to 15Vout
+5, –5
1.5, 1.5
HAA5-1.5/OVP-A
AA
A
+5, –5
3, 3
HBB5-3/OVP-A
BB
A
+5, –5
6, 6
HCC5-6/OVP-A
CC
A, C
+5, +12
2, 4
CP323-A
N
A, E
+5, +12
6, 2.5
CP510-A
CP510-A
A
5, 12 to 15
2, 0.5
HAA512-A
AA
A, C
5, 12 to 15
3, 1.25
HBB512-A
BB
A, C
5, 12 to 15
6, 2.5
HCC512-A
CC
A, C
+12, –5
1, 0.4
HAA15-0.8-A
AA
C
+12, –5
1.7, 0.7
HBB15-1.5-A
BB
C
+12, –12
0.4, 0.4
HAD12-0.4-A
B
B
+12, –12
1, 1
HAA15-0.8-A
AA
C
+12, –12
1.7, 1.7
HBB15-1.5-A
BB
C
+12, –12
3.4, 3.4
HCC15-3-A
CC
+12, –12
5, 5
HDD15-5-A
E
Case
Type
Dimensions
(Inches)
AA
6.50 x 4.00 x 2.10
B
4.87 x 4.00 x 2.10
BAA
10.25 x 4.00 x 2.95
BB
7.00 x 4.87 x 2.95
C
5.62 x 4.87 x 2.95
CBB
11.00 x 4.87 x 3.28
CC
9.38 x 4.87 x 3.28
CP131
11.00 x 4.87 x 3.28
CP510-A 8.25 x 4.87 x 3.28
D
9.00 x 4.87 x 3.28
DBB
14.25 x 4.87 x 3.38
DCC
15.00 x 4.88 x 4.55
E
14.00 x 4.87 x 3.53
F
16.75 x 4.88 x 5.00
N
7.00 x 4.87 x 3.28
C
Case
Type
Dimensions
(Millimeters)
C
AA
165.10 x 101.60 x 53.34
123.70 x 101.60 x 53.34
+12, –15
1, 0.8
HAA15-0.8-A
AA
C
B
+12, –15
1.7, 1.5
HBB15-1.5-A
BB
C
BAA
260.35 x 101.60 x 74.93
177.80 x 123.70 x 74.93
142.75 x 123.70 x 74.93
+12, –15
3.4, 3
HCC15-3-A
CC
C
BB
+12, –15
5, 5
HDD15-5-A
E
C
C
C
CBB
279.40 x 123.70 x 83.31
238.25 x 123.70 x 83.31
279.40 x 123.70 x 83.31
+15, –5
0.8, 0.4
HAA15-0.8-A
AA
+15, –5
1.5, 0.7
HBB15-1.5-A
BB
C
CC
+15, –12
0.8, 1
HAA15-0.8-A
AA
C
CP131
+15, –12
1.5, 1.7
HBB15-1.5-A
BB
C
CP510-A 209.55 x 123.70 x 83.31
+15, –12
3, 3.4
HCC15-3-A
CC
C
D
228.60 x 123.70 x 83.31
C
DBB
361.95 x 123.70 x 85.85
15, –12
5, 5
HDD15-5-A
E
Dual Output Models- 15V to 24Vout
+15, –15
0.4, 0.4
HAD15-0.4-A
B
B
+15, –15
0.8, 0.8
HAA15-0.8-A
AA
C
+15, –15
1.5, 1.5
HBB15-1.5-A
BB
C
+15, –15
3, 3
HCC15-3-A
CC
C
+15, –15
5, 5
HDD15-5-A
E
C
+18 to +20, –18 to –20
0.4, 0.4
HAA24-0.6-A
AA
+18 to +20, –18 to –20
0.9, 0.9
HBB24-1.2-A
BB
+18 to +20, –18 to –20
1.8, 1.8
HCC24-2.4-A
CC
+18 to +20, –24
0.4, 0.6
HAA24-0.6-A
AA
+18 to +20, –24
0.9, 1.2
HBB24-1.2-A
BB
+18 to +20, –24
1.8, 2.4
HCC24-2.4-A
CC
+24, –18 to –20
0.6, 0.4
HAA24-0.6-A
AA
+24, –18 to –20
1.2, 0.9
HBB24-1.2-A
BB
+24, –18 to –20
2.4, 1.8
HCC24-2.4-A
CC
+24, –24
0.6, 0.6
HAA24-0.6-A
AA
+24, –24
1.2, 1.2
HBB24-1.2-A
BB
+24, –24
2.4, 2.4
HCC24-2.4-A
CC
C
C
DCC
381.00 x 123.95 x 115.57
E
355.60 x 123.70 x 89.66
F
425.50 x 123.95 x 127.00
N
177.80 x 123.70 x 83.31
(See Additional Features Column)
A Overvoltage protection, set at 6.2 V ±0.4 V.
B Non-adjustable 3-terminal regulator.
C Remote sense provided.
D With output inhibit and parallel
operation master/slave capability.
E With output inhibit.
F Adjustable 3-terminal regulator.
G Can be made into an isolated output by
removing jumper W1.
H Model requires 100 LFM forced-air
cooling above 75% of rated output
power at 50 degrees C.
C
C
Model numbers highlighted in yellow or shaded are not recommended for new designs.
REV. FEB 11, 2005
Page 3 of 9
www.power-one.com
Linear Power Supplies Data Sheet
Triple and Quad Output Models
Unsigned output voltages are isolated and can be used as either + or - polarities.
Output
Voltage
(VDC)
Output
Current
(Amps)
Case
Type
Model (Input
Voltage of
100 to 240VAC)
Case
Type
Additional Features)
& Notes
Triple Output Models- 5V to 24Vout
Dimensions
(Inches)
AA
6.50 x 4.00 x 2.10
B
4.87 x 4.00 x 2.10
BAA
10.25 x 4.00 x 2.95
+5, –5, 24
6, 1.2, 3.5
CP379-A
CP131
A, C, F, G
BB
7.00 x 4.87 x 2.95
5, +12, –5
3, 1, 0.4
HBAA-40W-A
BAA
A, C
C
5.62 x 4.87 x 2.95
+5, +12 to +15, –5
6, 1, 0.4
HCAA-60W-A
D
A, C
CBB
11.00 x 4.87 x 3.28
+5, +12, 5
6, 5, 0.25
CP498-A
CP131
A, C, F
CC
9.38 x 4.87 x 3.28
11.00 x 4.87 x 3.28
5, +12, –5
8, 1.7, 0.7
CP131-A
CP131
A, C
CP131
5, +12, –5
12, 1.7, 0.7
HDBB-105W-A
DBB
A, C
CP510-A 8.25 x 4.87 x 3.28
5, +12 to +15, –5
2, 0.4, 0.4
HTAA-16W-A
AA
A
D
9.00 x 4.87 x 3.28
5, +12, –5
6, 1.7, 0.7
HCBB-75W-A
CBB
C
DBB
14.25 x 4.87 x 3.38
5, +12, –12
3, 1, 1
HBAA-40W-A
BAA
A, C
DCC
15.00 x 4.88 x 4.55
+5, +12 to +15, –12 to –15
6, 1, 1
HCAA-60W-A
D
A, C
E
14.00 x 4.87 x 3.53
+5, +12, 12
6, 5, 0.5
CP498-A
CP131
A, C, F
F
16.75 x 4.88 x 5.00
5, +12, –12
6, 1.7, 1.7
HCBB-75W-A
CBB
C
N
7.00 x 4.87 x 3.28
5, +12, –12
8, 1.7, 1.7
CP131-A
CP131
A, C
5, +12, –12
12, 1.7, 1.7
HDBB-105W-A
DBB
C
5, +12 to +15, –12 to –15
2, 0.4, 0.4
HTAA-16W-A
AA
A
Case
Type
Dimensions
(Millimeters)
5, +12, –12
12, 3.4, 3.4
HDCC-150W-A
DCC
A, C
AA
165.10 x 101.60 x 53.34
123.70 x 101.60 x 53.34
5, +12, –15
3, 1, 0.8
HBAA-40W-A
BAA
A, C
B
5, +12, –15
6, 1.7, 1.5
HCBB-75W-A
CBB
C
BAA
260.35 x 101.60 x 74.93
177.80 x 123.70 x 74.93
142.75 x 123.70 x 74.93
5, +12, –15
8, 1.7, 1.5
CP131-A
CP131
A, C
BB
5, +12, –15
12, 1.7, 1.5
HDBB-105W-A
DBB
C
C
5, +12, –15
12, 3.4, 3
HDCC-150W-A
DCC
A, C
CBB
279.40 x 123.70 x 83.31
+5, –12, 24
6, 1.2, 3.5
CP379-A
CP131
A, C, F, G
CC
238.25 x 123.70 x 83.31
5, +15, –5
3, 0.8, 0.4
HBAA-40W-A
BAA
A, C
CP131
279.40 x 123.70 x 83.31
5, +15, –5
6, 1.5, 0.7
HCBB-75W-A
CBB
C
CP510-A 209.55 x 123.70 x 83.31
5, +15, –5
8, 1.5, 0.7
CP131-A
CP131
A,
D
228.60 x 123.70 x 83.31
C
DBB
361.95 x 123.70 x 85.85
A, C
DCC
381.00 x 123.95 x 115.57
355.60 x 123.70 x 89.66
5, +15, –5
5, +15, –12
12, 1.5, 0.7
3, 0.8, 1
HDBB-105W-A
HBAA-40W-A
DBB
BAA
5, +15, –12
6, 1.5, 1.7
HCBB-75W-A
CBB
C
E
5, +15, –12
8, 1.5, 1.7
CP131-A
CP131
A, C
F
425.50 x 123.95 x 127.00
N
177.80 x 123.70 x 83.31
5, +15, –12
12, 1.5, 1.7
HDBB-105W-A
DBB
C
5, +15, –12
5, +15, –15
12, 3, 3.4
HDCC-150W-A
DCC
A, C
3, 0.8, 0.8
HBAA-40W-A
BAA
A, C
5, +15, –15
6, 1.5, 1.5
HCBB-75W-A
CBB
C
5, +15, –15
8, 1.5, 1.5
CP131-A
CP131
A, C
5, +15, –15
12, 1.5, 1.5
HDBB-105W-A
DBB
C
5, +15, –15
12, 3, 3
HDCC-150W-A
DCC
A, C
Quad Output Models- 5V to 24Vout Models
+5, +12, –5, +24
6, 1, 0.5, 2.4
CP503-A
CP131
A, H
+5, +12, –12, +24
6, 1, 1, 2.4
CP503-A
CP131
A, H
(See Additional Features Column)
A Overvoltage protection, set at 6.2 V ±0.4 V.
B Non-adjustable 3-terminal regulator.
C Remote sense provided.
D With output inhibit and parallel
operation master/slave capability.
E With output inhibit.
F Adjustable 3-terminal regulator.
G Can be made into an isolated output by
removing jumper W1.
H Model requires 100 LFM forced-air
cooling above 75% of rated output
power at 50 degrees C.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
REV. FEB 11, 2005
Page 4 of 9
www.power-one.com
Linear Power Supplies Data Sheet
Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
Input Voltage - AC
(Note 1, 2)
Jumper selectable, shipped factory configured for
120VAC operation. All models must be externally
fused for proper operation. Fuse ratings are marked
on each unit. Consult factory for each unit’s fuse
requirements.
AC input.
Output voltage charge for a 10% line change: F case models.
HAD12, HAD15.
Outputs with adjustable three terminal regulators.
All other models.
Input Frequency
Line Regulation
NOTES:
100 VAC Tap
120 VAC Tap
220 VAC Tap
240 VAC Tap
MIN
NOM
MAX
UNITS
87
104
191
209
100
120
220
240
110
132
242
264
VAC
47
-0.01
-1.0
-0.5
-0.05
63
+0.01
+1.0
+0.5
+0.05
Hz
MAX
UNITS
%
1) Derate output current 10% for 50Hz operation.
2) Input voltage tolerance for 230VAC operation is +15%, -10%.
Output Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
Output Adjustment
Efficiency
Minimum output adjustment range (Note 1).
-5
+5
%
5 volt outputs.
45
12 volt and 15 volt outputs.
55
%
24 volt and higher outputs.
60
F case models.
3.0
mVPK-PK
Ripple and Noise
5 volt, 12 volt, and 15 volt models.
5.0
mVPK-PK
(Note 2)
All three terminal regulator outputs.
0.2
%PK-PK
24 volt through 250 volt models.
3.0mVPK-PK plus 0.02% of output voltage, max
Load Regulation
Output change for a 50% load change: F case models.
-0.02
+0.02
HAD12, HAD15.
-1
+1
%
Outputs with adjustable three terminal regulators.
-0.5
+0.5
All other models.
-0.05
+0.05
Transient Response
Recovery time, to within 1% of initial set point due to a 50% load change.
50
µs
NOTES: 1) OUTPUT VOLTAGE ADJUSTMENTS: Output voltage adjustments can be made to within ±5% of nominal voltage. Locate the “Vadj” potentiometer on the power
supply PCB and use a screwdriver to adjust the output pot. The HAD12 and HAD15 3-terminal regulator outputs are not adjustable.
2) Full load, 20MHz bandwidth.
Safety, Regulatory, and EMI Specifications
PARAMETER
CONDITIONS/DESCRIPTION
Agency Approvals
UL1950.
CSA 1402 or CSA 22.2 No. 234/950.
EN60950 (TÜV).
Input to output.
Input to ground.
FCC CFR title 47 Part 15 Sub-Part B - conducted.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
Per EN60950
Dielectric Withstand
Voltage
Electromagnetic
Interference
Leakage Current
MIN
NOM
MAX
UNITS
Approved
3750
3750
VRMS
Compatible with system compliance to Level B.
(264VAC)
23
50
µA
NOM
MAX
UNITS
6.6
V
250
mV
140
%
Interface Signals and Internal Protection
PARAMETER
CONDITIONS/DESCRIPTION
MIN
Overvoltage Protection
Provided on 5 volt output units where indicated.
Other outputs may use optional overvoltage protectors OVP-12 and OVP-24.
Total voltage compensation for cable losses with respect to the main output.
Provided on models where indicated.
5.8
Automatic current limit/foldback. Rated as a percentage of output power.
115
Remote Sense
Overcurrent/Short Circuit
Protection
Master/Slave Operation
REV. FEB 11, 2005
120
For parallel operation of up to 6 units. Master/slave pin provided on F case models only. Contact factory for application notes.
Page 5 of 9
www.power-one.com
Linear Power Supplies Data Sheet
Environmental Specifications
PARAMETER
CONDITIONS/DESCRIPTION
Operating Temperature
Derate output power linearly above 50°C by 3% per °C.
Storage Temperature
Temperature Coefficient
Shock
Vibration
REV. FEB 11, 2005
MIN
At 100% load
At 40% load
NOM
MAX
UNITS
0.1
50
70
85
0.3
+0.3
20
6.15
°C
°C
°C
%/°C
%
GPK
GRMS
0
-40
0°C to 50°C (after 15 minute warm-up).
24 hours after warm-up.
Operating.
Random vibration from 10 Hz to 2 kHz, 3 axis.
Page 6 of 9
-0.3
www.power-one.com
Linear Power Supplies Data Sheet
REV. FEB 11, 2005
Page 7 of 9
www.power-one.com
Linear Power Supplies Data Sheet
REV. FEB 11, 2005
Page 8 of 9
www.power-one.com
Linear Power Supplies Data Sheet
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
REV. FEB 11, 2005
Page 9 of 9
www.power-one.com