The Bel Power Solutions produces the industry’s broadest selection
of Linear power supplies with output voltages from 5 to 48 Volts.
Rugged technology and proven design merge to create quiet, highlyregulated, dependable DC power.
The Linear power supplies are approved to domestic and
international regulatory standards, and are CE Marked to the Low
Voltage Directive (LVD).
•
RoHS compatible for all six substances
•
Worldwide AC Input Capabilities:
•
100/120/220/230/240 VAC
•
±0.05% Output Regulation
•
Low Output Ripple
•
Mean Time Before Failure (MTBF) 300,000 Hours
•
CE marked to Low Voltage Directive
•
100% Burn-In
•
2 Year Warranty
•
Overvoltage Protection (OVP) Standard on 5 V Single Outputs, Optional
for other outputs under 48 V
•
Used in industrial and medical applications needing low noise/ripple –
amplifiers, acoustic, broadcast, ATE and control equipment.
Linear Series
2
These optional overvoltage protection modules are offered for use with Linear Power Supplies. Each is user adjustable from 6.4 V to
34 V.
MODEL
SINGLE OUTPUT
DUAL OUTPUT
TRIPLE OUTPUT
PEAK CURRENT MODELS
CASE SIZE
OVP MODULES REQUIRED *
B, C, N, D
OVP-12G
E, F
OVP-24G
AA, B, BB, CC
OVP-12G protects both outputs
E
AA, BAA, D
CBB, 131
DBB, DCC
N, BAA, CBB
131
OVP-24G protects both outputs
OVP-12G protects both 12 V through 15 V outputs
OVP-12G protects any output not provided with built-in OVP
* Outputs with factory built-in OVP are indicated in the Voltage/Current Rating Chart for each model. OVP is not available for 48 V models.
tech.support@psbel.com
Linear Series
Model Input
100 to 264 VAC
3
Nominal
Vout*
Max
Amps
Case
Type
Additional
Features
Nominal
Vout*
Max
Amps
Case
Type
HA5-1.5/OVP-AG
5
1.5
B
A
HB5-3/OVP-AG
5
3
B
A, C
HA24-0.5-AG
24
0.5
B
HB24-1.2-AG
24
1.2
B
C
HC5-6/OVP-AG
5
6
C
HN5-9/OVP-AG
5
9
N
A, C
HC24-2.4-AG
24
2.4
C
C
A, C
HN24-3.6-AG
24
3.6
N
HD5-12/OVP-AG
5
12
D
C
A, C
HD24-4.8-AG
24
4.8
D
C
HE5-18/OVP-AG
5
18
F5-25/OVP-AG
5
25
E
A, C
HE24-7.2-AG
24
7.2
E
C
F
A, C, D, H
F24-12-AG
24
12
F
C, D, H
G5-35/OVP-AG
5
CP197-AG
5
35
F
A, C, D, H
HA24-0.5-AG
28*
0.5
B
50
F
A, C, D
HB28-1-AG
28
1
B
HA15-0.9-AG
HC28-2-AG
28
2
C
12
0.9
B
HN28-3-AG
28
3
N
C
HB12-1.7-AG
12
1.7
B
C
HD28-4-AG
28
4
D
C
HC12-3.4-AG
12
3.4
C
C
HE28-6-AG
28
6
E
C
HN12-5.1-AG
12
5.1
N
C
F24-12-AG
28*
10
F
C, D, H
HD12-6.8-AG
12
6.8
D
C
48 Vout
HE12-10.2-AG
12
10.2
E
C
HB48-0.5-AG
48
0.5
B
F15-15-AG
12
16
F
C, D, H
HC48-1-AG
48
1
C
HA15-0.9-AG
15*
0.9
B
HD48-3-AG
48
3
D
C
HB15-1.5-AG
15
1.5
B
C
HE48-4-AG
48
4
E
C
HC15-3-AG
15
3
C
C
HN15-4.5-AG
15
4.5
N
C
HD15-6-AG
15
6
D
C
HE15-9-AG
15
9
E
C
F15-15-AG
15*
15
F
C, D, H
5 Vout
Additional
Features
24 to 28 Vout
12 to 15 Vout
Case Type
Model Input
100 to 264 VAC
Dimensions
C
* May require jumpering or potentiometer adjustment.
Model numbers highlighted in yellow are not recommended
for new designs or reached End‐Of‐Life (EOL) status.
Additional Features:
inches
millimeters
AA
6.50 x 4.00 x 2.10
165.10 x 101.60 x 53.34
B
4.87 x 4.00 x 2.10
123.70 x 101.60 x 53.34
BAA
10.25 x 4.00 x 2.95
260.35 x 101.60 x 74.93
BB
7.00 x 4.87 x 2.95
177.80 x 123.70 x 74.93
C
5.62 x 4.87 x 2.95
142.75 x 123.70 x 74.93
CBB
11.00 x 4.87 x 3.28
279.40 x 123.70 x 83.31
CC
9.38 x 4.87 x 3.28
238.25 x 123.70 x 83.31
CP131
11.00 x 4.87 x 3.28
279.40 x 123.70 x 83.31
228.60 x 123.70 x 83.31
D
9.00 x 4.87 x 3.28
DBB
14.25 x 4.87 x 3.38
361.95 x 123.70 x 85.85
DCC
15.00 x 4.88 x 4.55
381.00 x 123.95 x 115.57
E
14.00 x 4.87 x 3.53
355.60 x 123.70 x 89.66
F
16.75 x 4.88 x 5.00
425.50 x 123.95 x 127.00
N
7.00 x 4.87 x 3.28
177.80 x 123.70 x 83.31
A
B
C
D
E
F
G
H
Overvoltage protection, set at 6.2 V ±0.4 V.
Non-adjustable 3-terminal regulator.
Remote sense provided.
With output inhibit & parallel operation master/slave capability.
With output inhibit.
Adjustable 3-terminal regulator.
Can be made into an isolated output by removing jumper W1.
Model requires 100 LFM forced-air cooling above 75% of rated
output power at 50°C.
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00650_AE
Linear Series
4
Model Input
100 to 264 VAC
Nominal
Vout*
Max
Amps
Case
Type
Additional
Features
+5, –5
1.5, 1.5
AA
A
inches
millimeters
AA
6.50 x 4.00 x 2.10
165.10 x 101.60 x 53.34
B
4.87 x 4.00 x 2.10
123.70 x 101.60 x 53.34
BAA
10.25 x 4.00 x 2.95
260.35 x 101.60 x 74.93
A
BB
7.00 x 4.87 x 2.95
177.80 x 123.70 x 74.93
5.62 x 4.87 x 2.95
142.75 x 123.70 x 74.93
5 to 15 Vout
HAA5-1.5/OVP-AG
HBB5-3/OVP-AG
+5, –5
3, 3
BB
A
HCC5-6/OVP-AG
+5, –5
6, 6
CC
A, C
HAA512-AG
5, 12 to 15
2, 0.5
AA
Dimensions
Case
Type
HBB512-AG
5, 12 to 15
3, 1.25
BB
A, C
C
HCC512-AG
5, 12 to 15
6, 2.5
CC
A, C
CBB
11.00 x 4.87 x 3.28
279.40 x 123.70 x 83.31
9.38 x 4.87 x 3.28
238.25 x 123.70 x 83.31
+12, –5*
1, 0.4
AA
C
CC
HBB15-1.5-AG
+12, –5*
1.7, 0.7
BB
C
CP131
11.00 x 4.87 x 3.28
279.40 x 123.70 x 83.31
HAD12-0.4-AG
+12, –12
0.4, 0.4
B
B
D
9.00 x 4.87 x 3.28
228.60 x 123.70 x 83.31
HAA15-0.8-AG
+12, –12
1, 1
AA
C
DBB
14.25 x 4.87 x 3.38
361.95 x 123.70 x 85.85
+12, –12
1.7, 1.7
BB
C
DCC
15.00 x 4.88 x 4.55
381.00 x 123.95 x 115.57
HCC15-3-AG
+12, –12
3.4, 3.4
CC
C
E
14.00 x 4.87 x 3.53
355.60 x 123.70 x 89.66
HDD15-5-AG
+12, –12*
5, 5
E
C
F
16.75 x 4.88 x 5.00
425.50 x 123.95 x 127.00
HAA15-0.8-AG
+12, –15*
1, 0.8
AA
C
N
7.00 x 4.87 x 3.28
177.80 x 123.70 x 83.31
HBB15-1.5-AG
+12, –15*
1.7, 1.5
BB
C
HCC15-3-AG
+12, –15*
3.4, 3
CC
C
HDD15-5-AG
+12, –15*
5, 5
E
C
HAA15-0.8-AG
+15, –5*
0.8, 0.4
AA
C
HBB15-1.5-AG
+15, –5*
1.5, 0.7
BB
C
HAA15-0.8-AG
+15, –12*
0.8, 1
AA
C
HBB15-1.5-AG
+15, –12*
1.5, 1.7
BB
C
HCC15-3-AG
+15, –12*
3, 3.4
CC
C
HDD15-5-AG
15, –12*
5, 5
E
C
HAD15-0.4-AG
+15, –15
0.4, 0.4
B
B
HAA15-0.8-AG
+15, –15
0.8, 0.8
AA
C
HBB15-1.5-AG
+15, –15*
1.5, 1.5
BB
C
HCC15-3-AG
+15, –15*
3, 3
CC
C
HDD15-5-AG
+15, –15
5, 5
E
C
HAA24-0.6-AG
+24, –24
0.6, 0.6
AA
HBB24-1.2-AG
+24, –24
1.2, 1.2
BB
HCC24-2.4-AG
+24, –24
2.4, 2.4
CC
HAA15-0.8-AG
HBB15-1.5-AG
15 to 24 Vout
Additional Features:
A
B
C
D
E
F
G
H
Overvoltage protection, set at 6.2 V ±0.4 V.
Non-adjustable 3-terminal regulator.
Remote sense provided.
With output inhibit and parallel operation master/slave
capability.
With output inhibit.
Adjustable 3-terminal regulator.
Can be made into an isolated output by removing jumper W1.
Model requires 100 LFM forced-air cooling above 75% of rated
output power at 50°C.
C
* May require jumpering or potentiometer adjustment.
Model numbers highlighted in yellow are not recommended
for new designs or reached End‐Of‐Life (EOL) status.
tech.support@psbel.com
Linear Series
5
Unsigned output voltages are isolated and can be used as either + or - polarities.
Model Input
100 to 264 VAC
Nominal
Vout*
Max
Amps
Case Type
Additional
Features
Dimensions
Case
Type
inches
millimeters
AA
6.50 x 4.00 x 2.10
165.10 x 101.60 x 53.34
B
4.87 x 4.00 x 2.10
123.70 x 101.60 x 53.34
BAA
10.25 x 4.00 x 2.95
260.35 x 101.60 x 74.93
BB
7.00 x 4.87 x 2.95
177.80 x 123.70 x 74.93
5 to 24 Vout
HTAA-16W-AG
+5, +12, –5*
2, 0.4, 0.4
AA
A
HBAA-40W-AG
5, +12, –5*
3, 1, 0.4
BAA
A, C
HCAA-60W-AG
+5, +12, –5*
6, 1, 0.4
D
A, C
HCBB-75W-AG
5, +12, –5*
6, 1.7, 0.7
CBB
C
CP131-AG
5, +12, –5*
8, 1.7, 0.7
CP131
A, C
C
5.62 x 4.87 x 2.95
142.75 x 123.70 x 74.93
A, C
CBB
11.00 x 4.87 x 3.28
279.40 x 123.70 x 83.31
9.38 x 4.87 x 3.28
238.25 x 123.70 x 83.31
HDBB-105W-AG
5, +12, –5*
12, 1.7, 0.7
DBB
5, +12, –12
2, 0.4, 0.4
AA
A
CC
HBAA-40W-AG
5, +12, –12
3, 1, 1
BAA
A, C
CP131
11.00 x 4.87 x 3.28
279.40 x 123.70 x 83.31
HCAA-60W-AG
+5, +12, –12
6, 1, 1
D
A, C
D
9.00 x 4.87 x 3.28
228.60 x 123.70 x 83.31
HCBB-75W-AG
5, +12, –12
6, 1.7, 1.7
CBB
C
DBB
14.25 x 4.87 x 3.38
361.95 x 123.70 x 85.85
CP131-AG
5, +12, –12
8, 1.7, 1.7
CP131
A, C
DCC
15.00 x 4.88 x 4.55
381.00 x 123.95 x 115.57
HDBB-105W-AG
5, +12, –12
12, 1.7, 1.7
DBB
C
E
14.00 x 4.87 x 3.53
355.60 x 123.70 x 89.66
HDCC-150W-AG
5, +12, –12
12, 3.4, 3.4
DCC
A, C
F
16.75 x 4.88 x 5.00
425.50 x 123.95 x 127.00
HTAA-16W-AG
5, +12, –15*
2, 0.4, 0.4
AA
A
N
7.00 x 4.87 x 3.28
177.80 x 123.70 x 83.31
HBAA-40W-AG
5, +12, –15*
3, 1, 0.8
BAA
A, C
HCAA-60W-AG
+5, +12, –15*
6, 1, 1
D
A, C
HCBB-75W-AG
5, +12, –15*
6, 1.7, 1.5
CBB
C
HTAA-16W-AG
CP131-AG
5, +12, –15
8, 1.7, 1.5
CP131
A, C
HDBB-105W-AG
5, +12, –15*
12, 1.7, 1.5
DBB
C
HDCC-150W-AG
5, +12, –15
12, 3.4, 3
DCC
A, C
HTAA-16W-AG
5, +15, –5*
2, 0.4, 0.4
AA
A
HBAA-40W-AG
5, +15, –5*
3, 0.8, 0.4
BAA
A, C
HCAA-60W-AG
+5, +15, –5*
6, 1, 0.4
D
A, C
HCBB-75W-AG
5, +15, –5*
6, 1.5, 0.7
CBB
C
CP131-AG
5, +15, –5*
8, 1.5, 0.7
CP131
A,
HDBB-105W-AG
5, +15, –5*
12, 1.5, 0.7
DBB
C
HTAA-16W-AG
5, +15, –12*
2, 0.4, 0.4
AA
A
HBAA-40W-AG
5, +15, –12*
3, 0.8, 1
BAA
A, C
HCAA-60W-AG
+5, +15, –12*
6, 1, 1
D
A, C
HCBB-75W-AG
5, +15, –12*
6, 1.5, 1.7
CBB
C
CP131-AG
5, +15, –12
8, 1.5, 1.7
CP131
A, C
HDBB-105W-AG
5, +15, –12*
12, 1.5, 1.7
DBB
C
A, C
Additional Features:
A
B
C
D
E
F
G
H
HDCC-150W-AG
5, +15, –12
12, 3, 3.4
DCC
HTAA-16W-AG
5, +15, –15*
2, 0.4, 0.4
AA
A
HBAA-40W-AG
5, +15, –15*
3, 0.8, 0.8
BAA
A, C
HCAA-60W-AG
+5, +15, –15*
6, 1, 1
D
A, C
HCBB-75W-AG
5, +15, –15*
6, 1.5, 1.5
CBB
C
CP131-AG
5, +15, –15
8, 1.5, 1.5
CP131
A, C
HDBB-105W-AG
5, +15, –15*
12, 1.5, 1.5
DBB
C
HDCC-150W-AG
5, +15, –15
12, 3, 3
DCC
A, C
Overvoltage protection, set at 6.2 V ±0.4 V.
Non-adjustable 3-terminal regulator.
Remote sense provided.
With output inhibit and parallel operation master/slave
capability.
With output inhibit.
Adjustable 3-terminal regulator.
Can be made into an isolated output by removing
jumper W1.
Model requires 100 LFM forced-air cooling above 75%
of rated output power at 50°C.
* May require jumpering or potentiometer adjustment.
Model numbers highlighted in yellow are not
recommended for new designs or reached End‐Of‐Life (EOL)
status.
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00650_AE
Linear Series
6
PARAMETER
AC Input Voltage 1, 2
Input Frequency
CONDITIONS / DESCRIPTION
Jumper selectable, shipped factory configured for
120 VAC operation. All models must be externally
fused for proper operation.
Fuse ratings are marked on each unit.
Consult factory for each unit’s fuse requirements.
MIN
NOM
MAX
100 VAC Tap
87
100
110
120 VAC Tap
220 VAC Tap
104
191
120
220
132
242
240 VAC Tap
209
240
264
AC input.
47
Output voltage charge for a 10% line change: F case models.
Line Regulation
HAD12, HAD15.
Outputs with adjustable three terminal regulators.
All other models.
PARAMETER
Output Adjustment
Efficiency
Ripple and Noise 4
CONDITIONS / DESCRIPTION
Minimum output adjustment range
-0.01
+0.01
-1.0
-0.5
+1.0
+0.5
-0.05
+0.05
MIN
3
Transient Response
NOM
-5
MAX
+5
5 volt outputs.
45
12 volt and 15 volt outputs.
55
24 volt and higher outputs.
60
VAC
Hz
%
UNITS
%
%
F case models.
3.0
mVPK-PK
5 volt, 12 volt, and 15 volt models.
5.0
mVPK-PK
All three terminal regulator outputs.
0.2
%PK-PK
3.0 mVPK-PK plus 0.02%
of output voltage, max
24 volt through 48 volt models.
Load Regulation
63
UNITS
Output change for a 50% load change: F case models.
-0.02
+0.02
HAD12, HAD15.
Outputs with adjustable three terminal regulators.
-1
-0.5
+1
+0.5
All other models.
-0.05
+0.05
Recovery time, to within 1% of initial set point due to a 50% load
change.
50
%
μs
1
Derate output current 10% for 50Hz operation.
Input voltage tolerance for 230 VAC operation is +15%, -10%.
3
Output voltage adjustments can be made to within ±5% of factory setting of nominal output voltage.
Locate the “Vadj” potentiometer on the power supply PCB and use a screwdriver to adjust the output pot.
The HAD12 and HAD15 3 terminal regulator outputs are not adjustable.
4
Full load, 20 MHz bandwidth.
2
tech.support@psbel.com
Linear Series
PARAMETER
7
CONDITIONS / DESCRIPTION
MIN
Dielectric Withstand
Voltage
Approved to the latest edition of the following standards;
UL/CSA 60950-1 and IEC/EN 62368-1
Input to case
Input to output (tested by manufacturer only)
2121
4242
Electromagnetic
FCC CFR title 47 Part 15 Sub-Part B - conducted.
Interference
EN 55022 / CISPR 22 conducted.
EN 55022 / CISPR 22 radiated.
Leakage Current
Per EN 62368-1 (264 VAC)
PARAMETER
CONDITIONS / DESCRIPTION
Agency Approvals
Overvoltage Protection
Remote Sense
Overcurrent/Short Circuit
Protection
Master/Slave Operation
NOM
UNITS
VDC
Compatible with system compliance to
Level B.
MIN
Provided on 5 V output units where indicated.
Other outputs may use optional overvoltage protectors OVP-12
and OVP-24.
Total voltage compensation for cable losses with respect to
the main output. Provided on models where indicated.
Automatic current limit/foldback. Rated as a percentage of
output power.
For parallel operation of up to 6 units. Master/slave pin provided
on F case models only. Contact factory for application notes.
PARAMETER
CONDITIONS/DESCRIPTION
Operating Temperature
Derate output power linearly above 50°C
by 3% per °C.
@ 100% load
Storage Temperature
50
NOM
MAX
UNITS
6.6
V
250
mV
5.8
115
120
140
%
MIN
NOM
MAX
UNITS
50
°C
70
°C
85
°C
0.3
%/°C
0
-40
0°C to 50°C (after 15-minute warm-up).
0.1
24 hours after warm-up.
-0.3
Shock
Operating.
Vibration
Random vibration from 10 Hz to 2 kHz, 3 axis.
Relative Humidity
Non-Condensing.
5
Asia-Pacific
+86 755 298 85888
μA
23
@ 40% load
Temperature Coefficient
MAX
+0.3
%
20
GPK
6.15
GRMS
95
%RH
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00650_AE
8
Linear Series
tech.support@psbel.com
Linear Series
9
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 49 8941
North America
+1 866 513 2839
© 2022 Bel Power Solutions & Protection
BCD.00650_AE
Linear Series
10
Mechanical Dimensions of Case Types
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the