0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HD28-4-AG

HD28-4-AG

  • 厂商:

    POWER-ONE

  • 封装:

    -

  • 描述:

    AC/DC CONVERTER 28V 112W

  • 详情介绍
  • 数据手册
  • 价格&库存
HD28-4-AG 数据手册
The Bel Power Solutions produces the industry’s broadest selection of Linear power supplies with output voltages from 5 to 48 Volts. Rugged technology and proven design merge to create quiet, highlyregulated, dependable DC power. The Linear power supplies are approved to domestic and international regulatory standards, and are CE Marked to the Low Voltage Directive (LVD). • RoHS compatible for all six substances • Worldwide AC Input Capabilities: • 100/120/220/230/240 VAC • ±0.05% Output Regulation • Low Output Ripple • Mean Time Before Failure (MTBF) 300,000 Hours • CE marked to Low Voltage Directive • 100% Burn-In • 2 Year Warranty • Overvoltage Protection (OVP) Standard on 5 V Single Outputs, Optional for other outputs under 48 V • Used in industrial and medical applications needing low noise/ripple – amplifiers, acoustic, broadcast, ATE and control equipment. Linear Series 2 These optional overvoltage protection modules are offered for use with Linear Power Supplies. Each is user adjustable from 6.4 V to 34 V. MODEL SINGLE OUTPUT DUAL OUTPUT TRIPLE OUTPUT PEAK CURRENT MODELS CASE SIZE OVP MODULES REQUIRED * B, C, N, D OVP-12G E, F OVP-24G AA, B, BB, CC OVP-12G protects both outputs E AA, BAA, D CBB, 131 DBB, DCC N, BAA, CBB 131 OVP-24G protects both outputs OVP-12G protects both 12 V through 15 V outputs OVP-12G protects any output not provided with built-in OVP * Outputs with factory built-in OVP are indicated in the Voltage/Current Rating Chart for each model. OVP is not available for 48 V models. tech.support@psbel.com Linear Series Model Input 100 to 264 VAC 3 Nominal Vout* Max Amps Case Type Additional Features Nominal Vout* Max Amps Case Type HA5-1.5/OVP-AG 5 1.5 B A HB5-3/OVP-AG 5 3 B A, C HA24-0.5-AG 24 0.5 B HB24-1.2-AG 24 1.2 B C HC5-6/OVP-AG 5 6 C HN5-9/OVP-AG 5 9 N A, C HC24-2.4-AG 24 2.4 C C A, C HN24-3.6-AG 24 3.6 N HD5-12/OVP-AG 5 12 D C A, C HD24-4.8-AG 24 4.8 D C HE5-18/OVP-AG 5 18 F5-25/OVP-AG 5 25 E A, C HE24-7.2-AG 24 7.2 E C F A, C, D, H F24-12-AG 24 12 F C, D, H G5-35/OVP-AG 5 CP197-AG 5 35 F A, C, D, H HA24-0.5-AG 28* 0.5 B 50 F A, C, D HB28-1-AG 28 1 B HA15-0.9-AG HC28-2-AG 28 2 C 12 0.9 B HN28-3-AG 28 3 N C HB12-1.7-AG 12 1.7 B C HD28-4-AG 28 4 D C HC12-3.4-AG 12 3.4 C C HE28-6-AG 28 6 E C HN12-5.1-AG 12 5.1 N C F24-12-AG 28* 10 F C, D, H HD12-6.8-AG 12 6.8 D C 48 Vout HE12-10.2-AG 12 10.2 E C HB48-0.5-AG 48 0.5 B F15-15-AG 12 16 F C, D, H HC48-1-AG 48 1 C HA15-0.9-AG 15* 0.9 B HD48-3-AG 48 3 D C HB15-1.5-AG 15 1.5 B C HE48-4-AG 48 4 E C HC15-3-AG 15 3 C C HN15-4.5-AG 15 4.5 N C HD15-6-AG 15 6 D C HE15-9-AG 15 9 E C F15-15-AG 15* 15 F C, D, H 5 Vout Additional Features 24 to 28 Vout 12 to 15 Vout Case Type Model Input 100 to 264 VAC Dimensions C * May require jumpering or potentiometer adjustment. Model numbers highlighted in yellow are not recommended for new designs or reached End‐Of‐Life (EOL) status. Additional Features: inches millimeters AA 6.50 x 4.00 x 2.10 165.10 x 101.60 x 53.34 B 4.87 x 4.00 x 2.10 123.70 x 101.60 x 53.34 BAA 10.25 x 4.00 x 2.95 260.35 x 101.60 x 74.93 BB 7.00 x 4.87 x 2.95 177.80 x 123.70 x 74.93 C 5.62 x 4.87 x 2.95 142.75 x 123.70 x 74.93 CBB 11.00 x 4.87 x 3.28 279.40 x 123.70 x 83.31 CC 9.38 x 4.87 x 3.28 238.25 x 123.70 x 83.31 CP131 11.00 x 4.87 x 3.28 279.40 x 123.70 x 83.31 228.60 x 123.70 x 83.31 D 9.00 x 4.87 x 3.28 DBB 14.25 x 4.87 x 3.38 361.95 x 123.70 x 85.85 DCC 15.00 x 4.88 x 4.55 381.00 x 123.95 x 115.57 E 14.00 x 4.87 x 3.53 355.60 x 123.70 x 89.66 F 16.75 x 4.88 x 5.00 425.50 x 123.95 x 127.00 N 7.00 x 4.87 x 3.28 177.80 x 123.70 x 83.31 A B C D E F G H Overvoltage protection, set at 6.2 V ±0.4 V. Non-adjustable 3-terminal regulator. Remote sense provided. With output inhibit & parallel operation master/slave capability. With output inhibit. Adjustable 3-terminal regulator. Can be made into an isolated output by removing jumper W1. Model requires 100 LFM forced-air cooling above 75% of rated output power at 50°C. Asia-Pacific +86 755 298 85888 Europe, Middle East +353 61 49 8941 North America +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00650_AE Linear Series 4 Model Input 100 to 264 VAC Nominal Vout* Max Amps Case Type Additional Features +5, –5 1.5, 1.5 AA A inches millimeters AA 6.50 x 4.00 x 2.10 165.10 x 101.60 x 53.34 B 4.87 x 4.00 x 2.10 123.70 x 101.60 x 53.34 BAA 10.25 x 4.00 x 2.95 260.35 x 101.60 x 74.93 A BB 7.00 x 4.87 x 2.95 177.80 x 123.70 x 74.93 5.62 x 4.87 x 2.95 142.75 x 123.70 x 74.93 5 to 15 Vout HAA5-1.5/OVP-AG HBB5-3/OVP-AG +5, –5 3, 3 BB A HCC5-6/OVP-AG +5, –5 6, 6 CC A, C HAA512-AG 5, 12 to 15 2, 0.5 AA Dimensions Case Type HBB512-AG 5, 12 to 15 3, 1.25 BB A, C C HCC512-AG 5, 12 to 15 6, 2.5 CC A, C CBB 11.00 x 4.87 x 3.28 279.40 x 123.70 x 83.31 9.38 x 4.87 x 3.28 238.25 x 123.70 x 83.31 +12, –5* 1, 0.4 AA C CC HBB15-1.5-AG +12, –5* 1.7, 0.7 BB C CP131 11.00 x 4.87 x 3.28 279.40 x 123.70 x 83.31 HAD12-0.4-AG +12, –12 0.4, 0.4 B B D 9.00 x 4.87 x 3.28 228.60 x 123.70 x 83.31 HAA15-0.8-AG +12, –12 1, 1 AA C DBB 14.25 x 4.87 x 3.38 361.95 x 123.70 x 85.85 +12, –12 1.7, 1.7 BB C DCC 15.00 x 4.88 x 4.55 381.00 x 123.95 x 115.57 HCC15-3-AG +12, –12 3.4, 3.4 CC C E 14.00 x 4.87 x 3.53 355.60 x 123.70 x 89.66 HDD15-5-AG +12, –12* 5, 5 E C F 16.75 x 4.88 x 5.00 425.50 x 123.95 x 127.00 HAA15-0.8-AG +12, –15* 1, 0.8 AA C N 7.00 x 4.87 x 3.28 177.80 x 123.70 x 83.31 HBB15-1.5-AG +12, –15* 1.7, 1.5 BB C HCC15-3-AG +12, –15* 3.4, 3 CC C HDD15-5-AG +12, –15* 5, 5 E C HAA15-0.8-AG +15, –5* 0.8, 0.4 AA C HBB15-1.5-AG +15, –5* 1.5, 0.7 BB C HAA15-0.8-AG +15, –12* 0.8, 1 AA C HBB15-1.5-AG +15, –12* 1.5, 1.7 BB C HCC15-3-AG +15, –12* 3, 3.4 CC C HDD15-5-AG 15, –12* 5, 5 E C HAD15-0.4-AG +15, –15 0.4, 0.4 B B HAA15-0.8-AG +15, –15 0.8, 0.8 AA C HBB15-1.5-AG +15, –15* 1.5, 1.5 BB C HCC15-3-AG +15, –15* 3, 3 CC C HDD15-5-AG +15, –15 5, 5 E C HAA24-0.6-AG +24, –24 0.6, 0.6 AA HBB24-1.2-AG +24, –24 1.2, 1.2 BB HCC24-2.4-AG +24, –24 2.4, 2.4 CC HAA15-0.8-AG HBB15-1.5-AG 15 to 24 Vout Additional Features: A B C D E F G H Overvoltage protection, set at 6.2 V ±0.4 V. Non-adjustable 3-terminal regulator. Remote sense provided. With output inhibit and parallel operation master/slave capability. With output inhibit. Adjustable 3-terminal regulator. Can be made into an isolated output by removing jumper W1. Model requires 100 LFM forced-air cooling above 75% of rated output power at 50°C. C * May require jumpering or potentiometer adjustment. Model numbers highlighted in yellow are not recommended for new designs or reached End‐Of‐Life (EOL) status. tech.support@psbel.com Linear Series 5 Unsigned output voltages are isolated and can be used as either + or - polarities. Model Input 100 to 264 VAC Nominal Vout* Max Amps Case Type Additional Features Dimensions Case Type inches millimeters AA 6.50 x 4.00 x 2.10 165.10 x 101.60 x 53.34 B 4.87 x 4.00 x 2.10 123.70 x 101.60 x 53.34 BAA 10.25 x 4.00 x 2.95 260.35 x 101.60 x 74.93 BB 7.00 x 4.87 x 2.95 177.80 x 123.70 x 74.93 5 to 24 Vout HTAA-16W-AG +5, +12, –5* 2, 0.4, 0.4 AA A HBAA-40W-AG 5, +12, –5* 3, 1, 0.4 BAA A, C HCAA-60W-AG +5, +12, –5* 6, 1, 0.4 D A, C HCBB-75W-AG 5, +12, –5* 6, 1.7, 0.7 CBB C CP131-AG 5, +12, –5* 8, 1.7, 0.7 CP131 A, C C 5.62 x 4.87 x 2.95 142.75 x 123.70 x 74.93 A, C CBB 11.00 x 4.87 x 3.28 279.40 x 123.70 x 83.31 9.38 x 4.87 x 3.28 238.25 x 123.70 x 83.31 HDBB-105W-AG 5, +12, –5* 12, 1.7, 0.7 DBB 5, +12, –12 2, 0.4, 0.4 AA A CC HBAA-40W-AG 5, +12, –12 3, 1, 1 BAA A, C CP131 11.00 x 4.87 x 3.28 279.40 x 123.70 x 83.31 HCAA-60W-AG +5, +12, –12 6, 1, 1 D A, C D 9.00 x 4.87 x 3.28 228.60 x 123.70 x 83.31 HCBB-75W-AG 5, +12, –12 6, 1.7, 1.7 CBB C DBB 14.25 x 4.87 x 3.38 361.95 x 123.70 x 85.85 CP131-AG 5, +12, –12 8, 1.7, 1.7 CP131 A, C DCC 15.00 x 4.88 x 4.55 381.00 x 123.95 x 115.57 HDBB-105W-AG 5, +12, –12 12, 1.7, 1.7 DBB C E 14.00 x 4.87 x 3.53 355.60 x 123.70 x 89.66 HDCC-150W-AG 5, +12, –12 12, 3.4, 3.4 DCC A, C F 16.75 x 4.88 x 5.00 425.50 x 123.95 x 127.00 HTAA-16W-AG 5, +12, –15* 2, 0.4, 0.4 AA A N 7.00 x 4.87 x 3.28 177.80 x 123.70 x 83.31 HBAA-40W-AG 5, +12, –15* 3, 1, 0.8 BAA A, C HCAA-60W-AG +5, +12, –15* 6, 1, 1 D A, C HCBB-75W-AG 5, +12, –15* 6, 1.7, 1.5 CBB C HTAA-16W-AG CP131-AG 5, +12, –15 8, 1.7, 1.5 CP131 A, C HDBB-105W-AG 5, +12, –15* 12, 1.7, 1.5 DBB C HDCC-150W-AG 5, +12, –15 12, 3.4, 3 DCC A, C HTAA-16W-AG 5, +15, –5* 2, 0.4, 0.4 AA A HBAA-40W-AG 5, +15, –5* 3, 0.8, 0.4 BAA A, C HCAA-60W-AG +5, +15, –5* 6, 1, 0.4 D A, C HCBB-75W-AG 5, +15, –5* 6, 1.5, 0.7 CBB C CP131-AG 5, +15, –5* 8, 1.5, 0.7 CP131 A, HDBB-105W-AG 5, +15, –5* 12, 1.5, 0.7 DBB C HTAA-16W-AG 5, +15, –12* 2, 0.4, 0.4 AA A HBAA-40W-AG 5, +15, –12* 3, 0.8, 1 BAA A, C HCAA-60W-AG +5, +15, –12* 6, 1, 1 D A, C HCBB-75W-AG 5, +15, –12* 6, 1.5, 1.7 CBB C CP131-AG 5, +15, –12 8, 1.5, 1.7 CP131 A, C HDBB-105W-AG 5, +15, –12* 12, 1.5, 1.7 DBB C A, C Additional Features: A B C D E F G H HDCC-150W-AG 5, +15, –12 12, 3, 3.4 DCC HTAA-16W-AG 5, +15, –15* 2, 0.4, 0.4 AA A HBAA-40W-AG 5, +15, –15* 3, 0.8, 0.8 BAA A, C HCAA-60W-AG +5, +15, –15* 6, 1, 1 D A, C HCBB-75W-AG 5, +15, –15* 6, 1.5, 1.5 CBB C CP131-AG 5, +15, –15 8, 1.5, 1.5 CP131 A, C HDBB-105W-AG 5, +15, –15* 12, 1.5, 1.5 DBB C HDCC-150W-AG 5, +15, –15 12, 3, 3 DCC A, C Overvoltage protection, set at 6.2 V ±0.4 V. Non-adjustable 3-terminal regulator. Remote sense provided. With output inhibit and parallel operation master/slave capability. With output inhibit. Adjustable 3-terminal regulator. Can be made into an isolated output by removing jumper W1. Model requires 100 LFM forced-air cooling above 75% of rated output power at 50°C. * May require jumpering or potentiometer adjustment. Model numbers highlighted in yellow are not recommended for new designs or reached End‐Of‐Life (EOL) status. Asia-Pacific +86 755 298 85888 Europe, Middle East +353 61 49 8941 North America +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00650_AE Linear Series 6 PARAMETER AC Input Voltage 1, 2 Input Frequency CONDITIONS / DESCRIPTION Jumper selectable, shipped factory configured for 120 VAC operation. All models must be externally fused for proper operation. Fuse ratings are marked on each unit. Consult factory for each unit’s fuse requirements. MIN NOM MAX 100 VAC Tap 87 100 110 120 VAC Tap 220 VAC Tap 104 191 120 220 132 242 240 VAC Tap 209 240 264 AC input. 47 Output voltage charge for a 10% line change: F case models. Line Regulation HAD12, HAD15. Outputs with adjustable three terminal regulators. All other models. PARAMETER Output Adjustment Efficiency Ripple and Noise 4 CONDITIONS / DESCRIPTION Minimum output adjustment range -0.01 +0.01 -1.0 -0.5 +1.0 +0.5 -0.05 +0.05 MIN 3 Transient Response NOM -5 MAX +5 5 volt outputs. 45 12 volt and 15 volt outputs. 55 24 volt and higher outputs. 60 VAC Hz % UNITS % % F case models. 3.0 mVPK-PK 5 volt, 12 volt, and 15 volt models. 5.0 mVPK-PK All three terminal regulator outputs. 0.2 %PK-PK 3.0 mVPK-PK plus 0.02% of output voltage, max 24 volt through 48 volt models. Load Regulation 63 UNITS Output change for a 50% load change: F case models. -0.02 +0.02 HAD12, HAD15. Outputs with adjustable three terminal regulators. -1 -0.5 +1 +0.5 All other models. -0.05 +0.05 Recovery time, to within 1% of initial set point due to a 50% load change. 50 % μs 1 Derate output current 10% for 50Hz operation. Input voltage tolerance for 230 VAC operation is +15%, -10%. 3 Output voltage adjustments can be made to within ±5% of factory setting of nominal output voltage. Locate the “Vadj” potentiometer on the power supply PCB and use a screwdriver to adjust the output pot. The HAD12 and HAD15 3 terminal regulator outputs are not adjustable. 4 Full load, 20 MHz bandwidth. 2 tech.support@psbel.com Linear Series PARAMETER 7 CONDITIONS / DESCRIPTION MIN Dielectric Withstand Voltage Approved to the latest edition of the following standards; UL/CSA 60950-1 and IEC/EN 62368-1 Input to case Input to output (tested by manufacturer only) 2121 4242 Electromagnetic FCC CFR title 47 Part 15 Sub-Part B - conducted. Interference EN 55022 / CISPR 22 conducted. EN 55022 / CISPR 22 radiated. Leakage Current Per EN 62368-1 (264 VAC) PARAMETER CONDITIONS / DESCRIPTION Agency Approvals Overvoltage Protection Remote Sense Overcurrent/Short Circuit Protection Master/Slave Operation NOM UNITS VDC Compatible with system compliance to Level B. MIN Provided on 5 V output units where indicated. Other outputs may use optional overvoltage protectors OVP-12 and OVP-24. Total voltage compensation for cable losses with respect to the main output. Provided on models where indicated. Automatic current limit/foldback. Rated as a percentage of output power. For parallel operation of up to 6 units. Master/slave pin provided on F case models only. Contact factory for application notes. PARAMETER CONDITIONS/DESCRIPTION Operating Temperature Derate output power linearly above 50°C by 3% per °C. @ 100% load Storage Temperature 50 NOM MAX UNITS 6.6 V 250 mV 5.8 115 120 140 % MIN NOM MAX UNITS 50 °C 70 °C 85 °C 0.3 %/°C 0 -40 0°C to 50°C (after 15-minute warm-up). 0.1 24 hours after warm-up. -0.3 Shock Operating. Vibration Random vibration from 10 Hz to 2 kHz, 3 axis. Relative Humidity Non-Condensing. 5 Asia-Pacific +86 755 298 85888 μA 23 @ 40% load Temperature Coefficient MAX +0.3 % 20 GPK 6.15 GRMS 95 %RH Europe, Middle East +353 61 49 8941 North America +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00650_AE 8 Linear Series tech.support@psbel.com Linear Series 9 Asia-Pacific +86 755 298 85888 Europe, Middle East +353 61 49 8941 North America +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00650_AE Linear Series 10 Mechanical Dimensions of Case Types NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. tech.support@psbel.com
HD28-4-AG
物料型号:文档中列出了多种型号的线性电源,例如HA5-1.5/OVP-AG、HB5-3/OVP-AG等,具体型号取决于输出电压和最大电流等参数。

器件简介:Bel Power Solutions生产的线性电源具有5至48伏的广泛输出电压选择,采用坚固的技术和经过验证的设计,创造出安静、高度调节、可靠的直流电源。

引脚分配:文档中提供了一些型号的引脚分配图,例如OVP-12G和OVP-24G,但未提供所有型号的详细引脚分配

参数特性:线性电源具备如下特性: - 符合RoHS标准,兼容六种物质 - 全球AC输入能力:100/120/220/230/240 VAC - ±0.05%的输出调节 - 低输出纹波 - 平均故障间隔时间(MTBF)300,000小时 - 符合低压指令的CE标志 - 100%老化测试 - 2年保修 - 过压保护(OVP)在5V单输出上为标准配置,48V以下其他输出为可选配置

功能详解:文档详细描述了线性电源的多种功能,包括过压保护选项、远程感应、输出抑制和并联操作能力等。

应用信息:线性电源被用于需要低噪声/低纹波的工业和医疗应用,如放大器、声学、广播、自动测试设备和控制设备。

封装信息:文档提供了不同型号的封装尺寸,包括英寸和毫米两种单位,以及一些型号的机械尺寸图。
HD28-4-AG 价格&库存

很抱歉,暂时无法提供与“HD28-4-AG”相匹配的价格&库存,您可以联系我们找货

免费人工找货