0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LDT960-72

LDT960-72

  • 厂商:

    BEL

  • 封装:

    -

  • 描述:

    AC/DCCONVERTER72V960W

  • 数据手册
  • 价格&库存
LDT960-72 数据手册
LDT Series are high power switching mode power supplies with 3 phase input 340 – 550 VAC, for powers from 480 to 2400 W, covering from 12 to 170 V (model dependent). Their compact size, high efficiency and excellent reliability together with easy installation due to pluggable connectors make them fit demanding applications where compactness and high power are needed. LDT Series are Class I isolation devices suitable for SELV and PELV circuitry and are designed to be mounted on DIN rail and installed inside a protective enclosure.  3 phase AC input: 3x 340 – 550 VAC  150% overload capability  High efficiency up to 92%  Up to 45°C operating temperature with no dating  Compactness  Continuity of operation if one phase is lost (model dependent)  User settable current limitation algorithm (Hiccup or Constant Current)  Easy parallelable for power increase  Multiple protections  Low noise thermal regulated 60 mm fan  Automation  Process Control  Communication  Instrumentation Equipment LDT960 Series 2 LDT960-24 400 - 500 VAC / 520 - 725 VDC 3 23 - 28 VDC 40 A LDT960-48 400 - 500 VAC / 520 - 725 VDC 3 45 - 55 VDC 20 A LDT960-72 400 - 500 VAC / 520 - 725 VDC 3 72 – 85 VDC 13.3 A Specifications are measured at 25°C, at 400 VAC, typical unless otherwise stated. Input AC Voltage 3 phases (UL certified) 400 – 500 VAC (Range 340- 550 VAC) Input DC Voltage 500 – 725 VDC Input Frequency 47 - 63 Hz Vin = 400 VAC Vin = 500 VAC Vin = 520 VAC Vin = 725 VAC Input AC Current Input DC Current Inrush Peak Current < 50 A Internal Protection Fuse None, external fuse must be provided External Protection on AC Line It is strongly recommended to provide external surge arresters (SPD) according to local regulations Output Power Rated Voltage (Adjustable Voltage Range) Continuous Current Overload Limit Short Circuit Peak Current Load Regulation 2.4 A 2.1 A 2.2 A 1.7 A Fuse AT 10A or MCB 10A C curve 960 W LDT960-24 LDT960-48 LDT960-72 LDT960-24 LDT960-48 LDT960-72 LDT960-24 LDT960-48 LDT960-72 LDT960-24 LDT960-48 LDT960-72 LDT960-24 LDT960-48 LDT960-72 24 VDC (23 – 28 VDC) 48 VDC (45 – 55 VDC) 72 VDC (72 – 85 VDC) 40 A 20 A 13.3 A 44 A 22 A 15 A 60 A 30 A 20 A ≤ 1.0% ≤ 0.5% ≤ 0.5% Ripple & Noise ≤ 100 mVpp Hold up Time > 15 ms User Interface Efficiency Green LED Red LED Current limitation mode jumper Dry contact LDT960-24 LDT960-48 LDT960-72 DC OK Overload 1 A / 30 V > 90.5% > 92.5% > 93% tech.support@psbel.com LDT960 Series Dissipated Power Output Over Voltage Protection Protections 3 LDT960-24 LDT960-48 LDT960-72 LDT960-24 LDT960-48 LDT960-72 Overload, short circuit, with constant current or hiccup mode (user settable) Thermal protection < 101 W < 78 W < 73 W > 33 VDC > 68 VDC > 100 VDC Parallel Connection Up to 4 units for increased power Redundancy With external ORing module Note: Power rating, losses, efficiency, ripple, thermal behavior may change outside of the nominal rated input range. Contact factory for details. Operating Temperature Over temperature protection, UL certified up to 45°C (Start-up type tested: - 40°C) Storage Temperature - 40 to + 80°C Derating - 15.0W/°C over 45°C Humidity Non-condensing 5 - 95% RH Overvoltage Category Pollution Degree EMC Emission EMC Standards EMC Immunity Standards & Approvals Isolation Voltage III 2 (IEC 664-1) Class A Class A Level 3 Level 3 Level 3 Level 4 Level 2 EN55022:2010 (CISPR22) EN55011:2009 /A1:2010 EN61000-4-2:2008 EN61000-4-3:2006 /A2:2010 EN61000-4-4:2012 EN61000-4-5:2014 EN61000-4-11:2004 /A1:2010 UL508 (certified) EN60950 (reference) Input to Output Input to Ground Output to Ground Protection Degree According to EN60529 Vibration sinusoidal IEC 60068-2-6:2007 Shock - 40 to + 70°C 4.2 kVDC 2.2 kVDC 0.75 kVDC IP20 5-17.8 Hz: ±1.6 mm; 17.8-500 Hz: 2g 2Hours / axis (X,Y,Z) 30 g 6 ms, 20 g 11 ms; 3 bumps / direction, 18 bumps total) IEC 60068-2-27:2008 INPUT CONNECTION 3 phase: L1 = Phase 1 L2 = Phase 2 L3 = Phase 3 I = Earth ground DC: L1 = +/L2 = -/+ L3 = do not connect I = Earth ground OUTPUT CONNECTION + = Positive DC - = Negative DC Dry contact = NC 1 AC/DC input 2 4 DC output (load) Status Output (dry contact, NC output OK) Green LED: Output OK 5 Red LED: Overload 6 Output voltage adjustment 7 Selectable limitation mode 3 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection BCD.00XXX_AA Asia-Pacific +86 755 298 85888 LDT960 Series 4 Weight 1.3 kg Dimensions 80.0 x 127.0 x 137.5 mm Mounting Rail IEC 60715/H15/TH35-7.5(-15) Connection Terminals Screw type (16 – 10 AWG) Screw type (10 – 6 AWG) ) for output on 24V model Case Material Aluminum 1.5 – 6 mm2 6 - 16 mm2 Figure 1. Mechanical Drawing NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. tech.support@psbel.com
LDT960-72 价格&库存

很抱歉,暂时无法提供与“LDT960-72”相匹配的价格&库存,您可以联系我们找货

免费人工找货