The PFC500 products of the PerFormanCe Power Series combine high
performance midrange power with high power density (4.4 watts/in3)
and high reliability to meet the requirements of communications,
commercial, and industrial systems.
Providing tightly regulated DC power, the PFC500 delivers full output
performance with only 300 Linear Feet per Minute (LFM) forced-air
cooling (factory-installed fan optional). Main channel current sharing
is provided for redundant applications.
Units are available with SAE mountings or optional metric mountings.
The PFC500 product line is approved to the latest international
regulatory standards, and displays the CE Mark.
RoHS Compliant
Power Factor Correction meets EN61000-3-2 (AC input
versions)
Fully-regulated outputs
Remote sense
Logic level Inhibit
Current Share, Power Fail, and Power Good Signals
Overtemperature, overvoltage, and overcurrent protected
Available with metric or SAE mountings
Input transient & ESD compliance to EN61000-4-2/-3/-4/-5
Fan output voltage and optional fan
Optional isolation diodes for parallel or redundant operation
DC input versions (36-75 VDC)
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2015 Bel Power Solutions, Inc.
North America
+1 866 513 2839
BCD.00595_AB
2
MODEL5
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAX. OUTPUT
CURRENT2
LINE
REGULATION
LOAD
REGULATION3
RIPPLE & NOISE
% p-p4
INITIAL SETTING
ACCURACY
PFC500-1024G
24V
21.6V to 26.4V
21A
0.5%
0.2%
1%
23.88V to 24.12V
PFC500-1028G
1
28V
25.2V to 30.8V
17.9A
0.5%
0.2%
1%
27.86V to 28.14V
PFC500-1048G
1
48V
46.0V to 56.0V
10.4A
0.5%
0.5%
1%
47.52V to 48.48V
NOTES:
1
2
3
4
5
Consult factory for availability of 28V and 48V units with DC input.
Output currents ratings are expressed with 300 LFM forced air.
Remote sense connected. See Application Note #P1 for load regulation when using the D option for 24V units.
Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. For ripple/noise on “D” option models,
see options data.
Models without suffix G use the lead solder exemption
PARAMETER
CONDITIONS / DESCRIPTION
MAX
UNITS
Input Voltage - AC
Continuous input range.
MIN
85
264
VAC
Input Frequency
AC Input.
47
63
Hz
Brown Out Protection
Lowest AC input voltage that regulation is maintained with full rated
loads.
85
VAC
Hold-Up Time
Over full AC input voltage range at full rated load.
20
ms
Input Current
85 VAC at full rated load.
Input Protection
Non-user serviceable internally located AC input line fuse, F10A, 250 V.
Inrush Surge Current
Internally limited by thermistor, one cycle, 25°C.
Power Factor
Per EN61000-3-2.
Operating Frequency
Switching frequency of main transformer.
PARAMETER
CONDITIONS / DESCRIPTION
Efficiency
Full rated load, 110 VAC.
110 VAC
220 VAC
Output Power
300 LFM forced air cooling required for operation. See optional fan.
Continuous power, multiple output models.
Overshoot / Undershoot
Output voltage overshoot/undershoot at turn-on.
PFC500-1024G
Without connection of remote sense.
PFC500-1028G
PFC500-1048G
Recovery time, to within 1% of initial set point due to a 50-100% load
change, 3% max. deviation.
Turn-on Delay
Time required for initial output voltage stabilization.
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%.
35
65
APK
W/VA
MIN
Full load, 20 MHz bandwidth.
Transient Response
ARMS
100
Ripple and Noise
Regulation
7.8
0.98
PFC500-1024G
PFC500-1028G
PFC500-1048G
Minimum loads
NOM
NOM
kHz
MAX
UNITS
75
%
0.6
0.6
1.2
Amps
See Model Selection Charts
500
Watts
0
V
0.8
0.7
1.0
%
1
ms
1
10
Sec
ms
tech.support@psbel.com
3
PARAMETER
CONDITIONS / DESCRIPTION
MIN
PFC500-1024G
PFC500-1028G
PFC500-1048G
Overvoltage Protection
NOM
27.0
32.0
60.0
MAX
UNITS
30.7
35.0
70.0
V
Overload Protection
Fully protected against output overload and short circuit. Automatic
recovery upon removal of overload condition.
Overtemperature Protection
System shutdown due to excessive internal temperature, automatic reset.
Remote Sense
Total voltage compensation for cable losses with respect to the main
output.
250
mV
Current Share
Accuracy of shared current with up to 6 parallel units.
10
%
Inhibit
Input Power
Fail Warning
Power Good
Fan Voltage
TTL compatible logic signal will inhibit outputs by the application of a logic
low signal. An open circuit or external TTL high signal allows normal
operation.
TTL compatible logic signal. Time before regulation dropout due to loss of
input power at 110 VAC.
TTL compatible signal. Signal is low if main output is
greater or less than 10% of nominal. For models without PFC500-1024G
the “D” option, internal pull-up resistor is 1k> For “D”
PFC500-1028G
option, pull-up resistor is 475. See Apps Note #P1 for
PFC500-1048G
details.
4
ms
22.08
25.20
44.20
27.36
30.80
54.72
Provides 170 mA current to user supplied fan if fan option is not
selected.
12
CONDITIONS / DESCRIPTION
Agency Approvals
Approved to the latest edition of the following standards.
UL/CSA60950-1, EN60950-1 and IEC60950-1
Dielectric Withstand
Meets reinforced insulation of IEC60950.
Electromagnetic Interference
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
B
B
Class
ESD Susceptibility
Per EN61000-4-2, level 4.
8
kV
Radiated Susceptibility
Per EN61000-4-3, level 3.
10
V/M
EFT/Burst
Per EN61000-4-4, level 4.
±4
kV
1
2
kV
Per EN61000-4-5 class 3.
Insulation Resistance
Input to output.
Leakage Current
Per EN60950, 264 VAC.
Line to Line
Line to Ground
NOM
V
PARAMETER
Input Transient Protection
MIN
V
MAX
UNITS
Approved
10
M
2.0
mA
tech.support@psbel.com
4
PARAMETER
CONDITIONS / DESCRIPTION
Altitude
Operating.
Non-Operating.
Operating Temperature
Derate linearly above 50°C by 2.5% per °C.
MIN
At 100% load
At 50% load
Storage Temperature
Forced Air Cooling
Forced air cooling of 300 LFM is required if the
internal fan is not specified. Cooling air velocity is
measured at the output exiting window (2.5” x 5”).
Airflow direction is from the input section to the
output section.
Temperature Coefficient
0°C to 70°C (after 15 minute warm-up).
Relative Humidity
Non-Condensing.
Shock
Vibration
PARAMETER
CONDITIONS / DESCRIPTION
Dimensions
Overall Length With Fan
Weight
Isolation Diodes
Fan
Metric Mounting
CONDITIONS / DESCRIPTION
Add “D” as a suffix to the model number to order factory installed
isolation diodes for parallel or redundant operation. For 24V models
with the “D” option, external caps are required to meet the 1%
noise/ripple spec. Power Good has a pull-up resistor of 475 on the
24V models. See Application Note #P1 for details.
Add “F” as a suffix to the model number to order integral fan.
Fan provides the required 300 LFM of forced air cooling, or
otherwise provided by the end user.
Add “M” as a suffix to the model number to order chassis with M4 x
0.7 mounting inserts.
MAX
UNITS
0
0
10k
40k
50
70
-55
85
°C
±0.05
%/°C
95
%RH
±0.02
5
Operating: 10±3mSec, 3 axis, Half Sine.
Non-operating: 10±3mSec, 3 axis, Half Sine.
Operating: 5-32 Hz
32-2000 Hz Sinusoidal
Non-operating:
Overall Size
PARAMETER
NOM
MIN
NOM
NOM
°C
20
40
0.02
1
6.15
in (DA)
GPK
GRMS
MAX
UNITS
228.6 x 127.0 x 63.5
9.00 x 5.00 x 2.50
266.7
10.50
1.95
4.3
MIN
ASL Ft.
MAX
G
mm
in
mm
in
kg
lb
UNITS
N/A
266.7 x 127.0 x 63.5
10.50 x 5.00 x 2.50
mm
in
N/A
tech.support@psbel.com
5
NOTES:
Chassis: 0.090" (2.3mm) Aluminum Alloy, With Clear Finish
*Airflow should be measured at the exiting window (5” x 2.5”).
Figure 1. Mechanical Drawing PFC500
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
tech.support@psbel.com
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Bel Power Solutions:
PFC500-1024F PFC500-1048F PFC500-1048G PFC500-1028FG PFC500-1024G
很抱歉,暂时无法提供与“PFC500-1048F”相匹配的价格&库存,您可以联系我们找货
免费人工找货