Type RJS
Telecom - Power Cross Protection & Ballast Protection
mCatalog
Number
RJS Fuses are primarily intended for use in telecommunication circuit
applications requiring low current protection with high surge tolerance.
They are typically used to replace heat coil type devices. They are designed
to be placed between the line input and the surge arresting components
(mov. gas tube, zenor diode, air gaps, etc.)
These fuses will withstand transient surge currents generated by
lightning in accordance with the attached table.
RJS fuses guard protected circuitry against sustained overload or
short circuit conditions. Such sustained overloads may be generated by
accidental contact between utility cables and phone lines (power line
cross).
RJS Fuse are used in circuits to obtain compliance with the test
requirements specified in UL 1950/60950 and Bellcore GR 1089.
Electrical Characteristics
Testing Current
100%
135%
200%
500%
1000%
Minimum
4 Hrs.
N/A
3 sec
100 msec
30 msec
Blow Time
Maximum
N/A
1 Hr
20 sec
1.5 sec
300 msec
Safety Agency
Approvals
r
S
Recognized File no.
E20624
Acceptance File no.
LR39772
10,000A, AC@ 125V
0.7 - 0.8
General Purpose
200A, AC@ 250V
0.7 - 0.8
Primary Protection
100A, AC@ 350V
Resistive
Ballast Protection
60A, AC@ 600V
Resistive
Telecom Protection
17
2.5
0.09
0.11
6
0.41
11
2.1
0.13
0.17
8
0.43
RJS 160
160mA
600V
7
1.8
0.21
0.26
10
0.46
RJS 200
200mA
600V
4.8
1.5
0.33
0.41
13
0.49
RJS 250
250mA
600V
3.2
1.3
0.51
0.64
16
0.53
RJS 300
300mA
600V
2.1
1.1
0.80
1.00
20
0.56
RJS 350
350mA
600V
1.7
1.0
1.0
1.3
24
0.58
RJS 400
400mA
600V
1.4
0.9
1.2
1.6
29
0.60
RJS 500
500mA
600V
0.9
0.78
1.9
2.4
36
0.64
RJS 600
600mA
600V
0.6
0.66
3.0
3.8
46
0.68
RJS 700
700mA
600V
0.49
0.61
3.8
4.8
54
0.70
RJS 750
750mA
600V
0.44
0.58
4.3
5.5
58
0.71
1A
600V
0.26
0.47
RJS 1.25
1.25 A
600V
0.17
0.40
RJS 1.5
1.5 A
600V
0.13
0.35
17
21
120
0.86
2A
600V
0.08
0.29
28
36
155
0.93
Environmental Specification
9.3
15
0.77
0.82
600V
0.05
0.24
44
56
190
0.99
600V
0.033
0.20
69
87
230
1.06
RJS 4
4A
600V
0.022
0.17
108
136
300
1.13
RJS 5
5A
600V
0.015
0.15
169
212
370
1.20
Consult manufacturer for other ratings
600V
600V
600V
600V
600V
600V
Less
Less
Less
Less
Less
Less
than
than
than
than
than
than
Double - exponential
Impulse Waveform
Waveform Duration Of A/B Seconds
Current
A=Rise Time=T1-T0 (1.25(b-a)
B=Duration=T2-T0
(Peak Value) Ip
1 hour
20 seconds
10 minutes
1 seconds
50 msec
20 msec
0.9 Ip
0.5 Ip
0.1 Ip
a
b
Time
T1
T2
Mechanical Dimensions
Standard Lead
Short Lead
Shock
MIL-STD-202, Method 213, Test Condition I
(100 G’s peak for 6 milliseconds)
A
0.76"+/-0.01"
(19.3+/-0.2mm)
0.76"+/-0.01"
(19.3+/-0.2mm)
B
0.80"+/-0.05
(20.3+/-1.27mm)
0.80"+/-0.05
(20.3+/-1.27mm)
Vibration
MIL-STD-202, Method 201 (10-55 Hz, 0.06 inch, total
excursion)
C
0.4" Typical
(10.0mm)
0.11"+/-0.01"
(2.8+/-0.25mm)
D
0.18" max
(4.6mm)
0.18" max
(4.6mm)
Salt Spray
MIL-STD-202, Method 101, Test condition B (48 hrs)
80
100
3A
TO
Soldering Techniques & Compatibility
Wave Solder: 260°C, 10 sec max. (MIL-STD-202, Method 210)
A
D
RECOMMENDED
PCB HOLE SIZE AND SPACING
1.0mm DIA.
C
0.80” ( 20.3mm)
B
Physical Specification
Materials
Body: Glass;
Lead Wire: Tin-lead plated Copper, Diameter 0.032"
Insulation Resistance
MIL-STD-202, Method 302, Test Condition A
(After Opening) 10,000 ohms minimum
Marking
On fuse: “bel”, “Type”“Current Rating” “Voltage Rating” “Appropriate
Safety Logos”
On label: Above info; Interrupting Rating plus “c”
Solderability
MIL-STD-202, Method 208
Resistance to solder Heat
MIL-STD-202, Method 210, Test Condition C (260°C, 20 sec)
Thermal Shock
MIL-STD-202, Method 107, Test Condition B (-65°C to+125°C)
Operating Temperature
-55°C to +125°C
7.4
12
2.5 A
135% Fuse rating
200% Fuse Rating
2.2A
7A
40A
60A
-55°C to +125°C
50 Pulses 1,000V
10 uS x 1000 u S
Maximum
Power
Dissipation
(W)
600V
Overload Current Voltage Clearing Time Limit
Operating Temperature
Peak Surge Current
(Amp)
600V
Power Cross (Telecom) Rating
(Fuse Rated 0.1 - 1.5A)
Intended
Application
Melting
I2T @10
In
(A2 Sec)
Melting
I2T< 10
mSec
(A2 Sec)
100mA
RJS 2.5
Power
Factor
Volt-drop
@100% In
(Vol)
max.
125mA
RJS 3
Interrupting Rating
Typical
Cold
Resistance
(ohm)
RJS 100
RJS 2
rSc
Voltage
Rating
RJS 125
RJS 1
(UL/CSA STD. 248-14)
Approvals
Ampere
Rating
Packaging
In bulk : 2,000 pcs per box. (standard Lead) 500 pcs per box. (short Lead)
Specifications subject to change without notice
RJSD0303
ORDERING INFORMATION SEE PAGES 67 & 68
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel: 201-432-0463 • Fax: 201-432-9542 • E-Mail: belfuse@belfuse.com
Website: www.belfuse.com
35
Type RJS
Telecom - Power Cross Protection & Ballast Protection
RJSC0303
- 100mA
- 125mA
- 160mA
- 200mA
- 250mA
- 300mA
- 350mA
- 400mA
- 500mA
- 600mA
- 750mA
- 1A
- 1.25A
- 1.5A
- 2A
- 2.5A
- 3A
- 4A
- 5A
RJS - TIME CURRENT CHARACTERISTIC CURVE
10000
1000
TIME IN SECONDS
100
10
0.1
0.01
0.01
0.1
1
10
100
1000
CURRENT IN AMPERES
Specifications subject to change without notice
1
NOTE - see important information under “User Guide”on P.08
Corporate Office
Bel Fuse Inc.
206 Van Vorst Street, Jersey City, NJ 07302
Tel: 201-432-0463
Fax: 201-432-9542
E-Mail: belfuse@belfuse.com
Website: www.belfuse.com
Far East Office
Bel Fuse Ltd.
8F/8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel: 852-2328-5515
Fax: 852-2352-3706
European Office
Bel Fuse Europe Ltd.
Preston Technology Management Centre
Marsh Lane, Preston PR1 8UD
Lancashire, U.K
Tel: 44-1772-556601
Fax: 44-1772-888366
36
很抱歉,暂时无法提供与“RJS600”相匹配的价格&库存,您可以联系我们找货
免费人工找货