K78XX-2000R3 Series–2A
Non-isolated
Features
4.75~36Vin(3.3Vout).6.5-36Vin(5.0Vout)
Fixed Output: 3.3 or 5V @ 2A
Vertical SIP, small footprint package
Description
“No heat sink” direct replacement for
The K78XX-2000R3 Series are non-isolated DC/DC
converters suited to replace 2Amp LM78xx linear
regulators. Designed with highly efficiency, allow the
operating temperature range of these units to be -40°C
to +85°C in a 11.6*8.5*17.5mm. Further features include
wide 4.75~36VDC input voltage range, short-circuits
protection and over temperature protection.
3-terminal78xx-series linear regulators
High efficiency with no external components
Short circuit protection
Outstanding thermal derating performance
UL/EN/IEC 60950-1, 2nd Edition safety meets
Technical Specification All specifications are typical at nominal input, full load and 25°C unless otherwise stated.
Model
Number
Input Voltage
Range
Output
Voltage
(V)
Min. Load (1)
Full. Load
Vin_min
Vin_max.
Capacitive Load,
max. (3) (uF)
K7803-2000R3
4.75-36V
Nominal:12V
3.3
0
2000
90
86
1800
K7805-2000R3
6.5-36V
Nominal:12V
5
0
2000
93
90
1000
Eff .(2) (%)
Output Current (mA)
Input Specifications
Input voltage
K7803-2000R3
12V nominal input
4.75-36V
K7805-2000R3
12V nominal input
6.5-36V
Input filter
Input Reverse Polarity
Capacitor type
None, install external fuse(2A Fast blow)
No Load Input Current
10mA Typ.
Hot swap is not supported
Environmental Specifications
Operating ambient temperature
-40°C to +85°C (with derating)
Storage temperature range
-55°C to +125°C
Relative humidity
5% TO 95% RH max.
Temperature coefficient
±0.02% / °C Typ.
RoHS Compliant
RoHS 2.0
Output Specifications
2A max.
Output current
Voltage accuracy
At 50% load
-4% Min.
+4% Max.
Minimum load
(No minimum load)
Line regulation
Vin=min. to max. Vout=nom.
E-mail: bothhand_sales@bothhandww.com
https://www.bothhandww.com
0mA
±0.4% Typ
±0.8% max.
Rev: A0
Page 1 of 5
Load Regulation
±0.5% Typ
±1.5% max
10 -100% load
Ripple and Noise (20MHz Bandwidth)
75mVp-p max.
Capacitive load
2200uS max
200% Typ
250% max
Over Current Protection(OCP)
100%=1A
Short Circuit Protection(SCP)
Continuous, autorecovery
General Specifications
Efficiency
See table
Switching frequency (Fixed)
Pulse width modulation (PWM)
410kHz Typ
Dynamic load response
75-100-75% 25%load step
100uS Typ
Reliability, calculated MTBF
K7803-2000R3/ K7805-2000R3
2.0×106Hrs
Safety(5)
UL-60950-1,IEC/EN60950-1,2nd Edition
meet
Physical Specifications
Dimensions
0.45 × 0.33 × 0.68 Inch
(11.6 × 8.5 × 17.5 mm)
Weight
4g (0.142oz) typ.
Efficiency Curve
K7803-2000R3
K7805-2000R3
Efficiency vs Line Voltage and Load Current@+25°C(Vout=Vnom.)
0
0.2
0.4
0.6
0.8
1.0
1.2
1.6
Efficiency vs Line Voltage and Load Current@+25°C(Vout=Vnom.)
2.0
0
0.2
0.4
Load Current (Amp)
0.6
0.8
1.0
1.2
1.6 2.0
Load Current (Amp)
Power Derating Curve
Maximum Current Temperature Derating at sea level(Vin=6.5V to 36V)
Output Current (Amps)
3.00
2.00
1.00
0.00
20
25
30
35 40
45
50
55
60 65
70
75
80 85
Ambient Temperature (°C)
E-mail: bothhand_sales@bothhandww.com
https://www.bothhandww.com
Rev: A0
Page 2 of 5
Note
1. Io below this value will not damage these converters, however, they may not meet all listed specifications.
2. Typical value, tested at nominal input and full load.
3. Specifications subject to change without notice.
4. This power module is not internally fused. The input line fuse must always be used.
5. Input Back Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth.
Input filtering is Cin=2x 100 uF, Cbus=1000 uF, Lbus=1 uH. All caps are low ESR types.
Mechanical Dimensions
SIDE
VIEW
FRONT
VIEW
Pin Assignment
Pin
Define
1
2
3
Positive Input
Common(Ground)
Positive Output
BOTTOM
VIEW
Unit: mm
Tolerance: XX.X=±0.5, XX.XX=±0.25
Package Information
27.84±0.30
6.81±0.30
11.73±0.30
20.6±0.30
0.6±0.30
PS:
Unit: mm [inch]
L= 220 mm[8.66 inch] ; ONE TUBE = 16 PCS
E-mail: bothhand_sales@bothhandww.com
https://www.bothhandww.com
Rev: A0
Page 3 of 5
Test Configurations
All specifications are typical at nominal input, full load and 25°C unless otherwise stated.
A
DC
Power Supply
A
DC/DC
converter
V
V
Load
◎DC Power Supply: It offers a wide voltage and current range precisely.
◎Current meter (A): Accuracy200μA ~ 200mA 4 ranges+(0.2% rdg + 2 digits)
2000mA ~ 20A 2 ranges+(0.3% rdg + 2 digits).
◎Voltage meter (V): Accuracy+(0.03% rdg + 4 digits).
◎Load: At full load.
◎Wires: The resistance of the wires must be small.
1. Ripple and Noise: as shown below. The bandwidth is 0-20MHz.
Noise
Ripple&Noise
Ripple
Output Ripple&Noise measurement test circuit: as shown below.
Copper strip
DC/DC
converter
Co
Oscilloscope
Load
Copper strip
Co: usually 10uF to 47uF use low-ESR ceramic.
2. Temperature derating curve: The DC-DC converter will operate over a wider temperature range if less power
is drawn from the output and the device is already running. The temperature derating curve shows the operating
power-temperature range. As shown below.
E-mail: bothhand_sales@bothhandww.com
https://www.bothhandww.com
Rev: A0
Page 4 of 5
Maximum Current Temperature Derating at sea level(Vin=6.5V to 36V)
Output Current (Amps)
2.00
1.00
0.00
20
25
30
35 40
45
50
55
60 65
70
75
80 85
Ambient Temperature (°C)
3. Application circuit: as shown below. C1=10uF/50V MLCC, C2 =47uF/16V MLCC.
+Vin
1
C1
DC-DC
converter
2
3
+Vout
C2
Load
GND
E-mail: bothhand_sales@bothhandww.com
https://www.bothhandww.com
Rev: A0
Page 5 of 5
很抱歉,暂时无法提供与“K7803-2000R3”相匹配的价格&库存,您可以联系我们找货
免费人工找货